Tender For Annual Maintenance And Operation Contract Of Fire Alarm System, Fire Detection System And Fire Fighting System Installed In New High Court Of Jharkhand At Dhurwa, Ranchi.
Tender Value
99.59 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
4 days left
EMD
1.99 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance And Operation Contract Of Fire Alarm System, Fire Detection System And Fire Fighting System Installed In New High Court Of Jharkhand At Dhurwa, Ranchi.
BOQ
| Sl. No. | Item Description |
| 1 | Providing Fire fighting fitter highly skilled professionally expert with proper dressup required tools all complete job. |
| 2 | Providing Wireman/line man cum fire Alarm Panel Operator highly skilled Professionally expert with proper dressup required tools all complete job. |
| 3 | Providing Electrician Grade-1 Fire Alarm Electrician Cum Supervisor highly skilled Professionally expert with proper dressup required tools all complete job. |
| 4 | Servicing, Re-Commissioning and overhauling of Electrical Motor Driven, Centrifugal Pump Set for Hydrants and Sprinkler System consisting of Horizontal Split Case, Centrifugal Pump with Accessories Capacity of 2850 LPM at 70 Mtr Head with CI casing, Standard Fittings, CS Diffusers Bronze Impellar Shaft with Mechanical Seal. The installation shall be complete with flexible coupling and coupling guard, 150mm Dia pressure guage of 0-16kg/cm2 range with gun metal shut off cock on delivery side as required. |
| 5 | Servicing, Re-Commissioning and overhauling of Diesel Engine Driven, Pump Set for Hydrants and Sprinkler System consisting of Horizontal Split Case, Centrifugal Pump with Accessories Capacity of 2850 LPM at 70 Mtr Head with CI casing, Standard Fittings, CS Diffusers Bronze Impellar Shaft with Mechanical Seal. The installation shall be completed with flexible coupling and coupling guard, 150mm Dia pressure guage of 0-16kg/cm2 range with gun metal shut off cock on delivery side as required. |
| 6 | Servicing, Re-Commissioning and overhauling of Jockey Pump Set Capacity 180 LPM at 70 Mtr consisting of Horizontal Split Case, Centrifugal Pump with Accessories with CI casing, Standard Fittings, CS Diffusers Bronze Impellar Shaft with Mechanical Seal. The installation shall be completed with flexible coupling and coupling guard, 150mm Dia pressure guage of 0-16kg/cm2 range with gun metal shut off cock on delivery side as required. |
| 7 | Servicing, overhauling, and Re-commissioning of Control Panel on common cubical with all the parts required as Delta Starter and MCCB and Bus Bars for Motor Driven and Engine Driven or as per requirement of the drivers and with logic of Operation sequence as per specification with all material accessories, instruments etc. complete. |
| 8 | Servicing, Re-Commissioning and overhauling of Chromium plated brass quartzoid Pendant sprinkler (68 Degree Celsius) of 20mm Dia size suitable the 175psi pressure on the seat and water hammer effect. (Pendant Sprinkler) |
| 9 | Servicing, Re-Commissioning and overhauling of oblique more pattern single outlet SS hydrant Landing Valve 80mm Flanged inlet 63mm Dia instantaneous type SS female outlet conforming to IS-5290 with MS Hand Wheel SS blank cap & chain twist release type plate including nuts and bolts, washers, gaskets with necessary fitting like tees, elbow etc. |
| 10 | Servicing and Re-Commissioning and Overhauling of Swinging Type First Aid Hose Reel Drum in red Color with 36 Mtr Long and 19mm Dia Heavy Duty Rubber Water Hose pipe, 199mm Dia Globe Valve Stop Cock, with Nozzle of 6mm Dia Outlet with Shut off Nozzle confirming to IS 8090-1976 Complete set. |
| 11 | Service Cleaning, testing and Re wind of Non Percolating Rubber Reinforced Lined Fire Hose Pipe(as Per IS:636) of 63MM Dia and length 15 mm long. The Hose shall be rated for burst pressure of 37.5Kg/sqcm. Hose Shall be completed with ISI marked SS make male and female coupling (IS 903) and riverted to hose pipe with copper rivets and 1.5mm copper wire. (For Internal hydrants) |
| 12 | Servicing and re-Commissioning and Overhauling of Fire Brigade Inlet Connection Consisting of 3 Nos 63mm Dia Instantaneous Type Male Coupling with built in check valve 1 Nos. 150mm Dia SS Sluice Valve, 1 No CS Non-Return Valve and 150mm Dia Flanged outlet complete as required. (For Wet Risers) |
| 13 | 2 Way |
| 14 | 4 Way |
| 15 | Servicing, Re-commissioning and Overhauling of of Control Valve with turbine Type Automatic Alarm(Water Gong Bell) to be connected with control valve, drain test valve. 150mm Dia |
| 16 | Providing and Fixing of Stainless Steel Corrugated flexible Pipe for Dropping Sprinklers below false ceiling, pipe shall be UL listed 16 bar rating 1000mm, 25mm Dia with union/reducer as required. |
| 17 | Servicing, Re-commissioning and Overhauling of Butterfly Valve Conforming to IS-13095(PN 1.6) Body Cast Steel, Shaft steel, SS Disc, SG Iron (Rilson Coated) Tested to a pressure not less than 15 Kg/Sq. Cm including Rubber gasket, Flanges, Nut and bolt washers. |
| 18 | 100MM Dia |
| 19 | 150MM Dia |
| 20 | Servicing, Re-commissioning and Overhauling of CG Sluice Valve Full way standard pattern confirming to IS:10611with all fittings |
| 21 | 200MM Dia |
| 22 | Servicing, Re-commissioning and Overhauling of CS Non Return Valve IS:10989swing type with natural rubber flap with flanges, nut and bolt washers stc as required |
| 23 | 100MM Dia |
| 24 | 150MM Dia |
| 25 | Servicing, Re-commissioning and Overhauling of Brass Ball Valve(Suitable for pressure less than 16Kg/Sq.cm) |
| 26 | 25MM Dia |
| 27 | Painting with two coats of Firie Synthetic enamel paint of approved shade and brand over a coat of Red oxide zinc chromate primer. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends and direction completed as per the requirement. (Yard hydrant line). |
| 28 | Painting with two coats of Fire Synthetic enamel paint of approved shade and brand over a coat of Red oxide zinc chromate primer. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends and direction completed as per the requirement. (Wet Riser Line). |
| 29 | Refilling, testing and servicing of ABC Type 4Kg Fire Extinguishers in HP Mild Steel Cylinder fitted with pressure indicating gauge, internal tube, squeeze lever type valve gully charged with ABC powder mono ammonium phosphate pressured by nitrogen complete in all respects |
| 30 | Refilling of Water Type Fire Extinguishers Flat base including Valve, discharge hose, 1 M Long and complete in all respects including initial fill with Co2 gas confirming to IS:15222-1999) filled to a filling rate of not more than 0.667. (4.5 Kg) |
| 31 | Service & Re-Commissioning of addressable manual call point complete as required. |
| 32 | Servicing and Re-Commissioning of addressable Horn cum strobe complete as required. |
| 33 | Servicing testing and Re-commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . |
| 34 | Servicing, cleaning, Re-installation testing & Re-Commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 35 | Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 36 | Supplying laying re conecting with existing netwok cables of Fire retardant PVC insulated copper conductor cable in the existing surface/recessed steel conduit of 2x1.5Sqmm including connections and inter connections etx as required. |
| 37 | Supplying laying and replacing of 25mm Dia MS flexible pipe with existing line with all accessories like coupler gitti screw etc as required. |
| 38 | Supply and fixing of Fire Exit Sign of Different sizes and shapes as applicable at site or as per E/I |
| 39 | Providing ,fixing and Commissioning of fire bucket of Mild Steel Powder coated with P.O Red colour as approved of six Bucket's with Canopy and stands etc as required at site. |
| 40 | Supply and fixing of Double door with locking arrangement fire hose cabinet which can have a capacity of occupy 2 hose Pipe 15 mtrs long along with short branch nozzle for fire fighting system duly mounted on wall with PO red color paint as required. |
| 41 | Add 18 % GST (in Basic Rate must fill 12) |
| 42 | Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysAug 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender