Tender For Repair/ Replacement/ Main Of Summer/ Winter Appliances At Mh, Hq Signal Regt, Ub Area Sig Coy And Ge (U) Meerut Cantt, Dabathwa And Cmvl Area Under Age E/M (Es) At Ge (U) Meerut Cantt.
Tender Overview
Project Description
Tender for Repair/ Replacement/ Main Of Summer/ Winter Appliances At Mh, Hq Signal Regt, Ub Area Sig Coy And Ge (U) Meerut Cantt, Dabathwa And Cmvl Area Under Age E/M (Es) At Ge (U) Meerut Cantt.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 15-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M&L for dismantling of split AC complete inner and outer unit upto 2 TR after removing all connection like refrigerant pipe/voltage stabiliser safely and refixing the same at the other location including making all connection and testing in on position all as specified and directed. (Rate quoted by contractor shall deemed to include for core cutting/wall cutting including making hole for refrigerant pipe etc . No extra items except refrigerant gas if reqd shall be paid) |
| 2 | Supply and fix in replacement of unserviceable micro processor PC board with new microprocessor PC board with remote by dismantling /disconnecting the same carefully without disturbing other components up to 2 TR capacity AC including making necessary fixing arrangement etc., complete all as specified & directed. |
| 3 | M &L for dismanling of window type AC from its own position and refixing the same in other location safely including making connection and testing complete all as specified and directed. |
| 4 | Taking down perished Unserviceable insulation cover of refrigerent piping and Supplying & Fixing brutile rubber insulation for refrigerent pipings of suitable size. |
| 5 | Supplying and Fixing in repairs Copper refrigerant pipe Copper tube 5/8 \\" x 3/8\\". |
| 6 | Supplying and Fixing in repairs Copper refrigerant pipe Copper tube 1/2 \\" x 1/4\\". |
| 7 | Supplying and Fixing in repairs Copper refrigerant pipe Copper tube 5/8 \\" x 1/4\\". |
| 8 | Material and Labour for removing the Split type Air conditioner outdoor unit/indoor unit from its position for pressure/ leak testing & arresting the leakages in condenser coil /cooling coil by brazing etc and gas charging as per reqd basis complete for Split type AC 1.5 ton / 2.0 ton / 3 TR. (Notes : Rates quoted by the contractor shall includes for refrigerant gas charging as per required basis |
| 9 | Supply and fix in replacement of rotary type compressor for window/split air conditioner of cap 1.5 TR Air conditioning including making all connection , testing all as specified and directed. |
| 10 | All as per item No-9 above but of capacity 2 TR Split AC |
| 11 | Material and Labour for complete servicing after pumping down Indoor/outdoor units of split AC complete by cleaning condenser/ Evaporator coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, cleaning the air filter for split air conditioner upto 2 TR all as specified and directed. Notes :- (i) The rate deemed includes for minor spares (ii) Gas shall be measured and paid separately under relevant item. |
| 12 | All as per item No.11 here in before but for Window Type Air conditioiner upto 2 TR cap |
| 13 | Supply and fix in replacement of UNSV starting capacitor of 80/100 mfd suitable for split/window type Air conditioner upto 2 tr complete all as specified & directed. |
| 14 | Supply and fix in replacement of running capacitor 25/36/45/50 mfd suitable for window/split type air conditioners up to 2 TR capacity. |
| 15 | Disconnecting and taking down unserviceable internal wiring of window/split type air conditioner up to 3 TR capacity and supply and rewiring complete with copper conductors complete including testing and commissioning all as specified and as directed. |
| 16 | Supply and fix plastic /coir filter suitable for window/split type air conditioner up to 3 TR capacity including taking down old unserviceable plastic filters etc complete all as specified and as directed. |
| 17 | Removing defective unserviceable fan blades from window/split type air-conditioners up to 2 TR capacity and supply and fix new blade suitable for air-conditioners of existing AC make of LG/Blue star/Voltas/Carrierall as specified and as directed. |
| 18 | Time delay timer cum single phase preventer suitable for 2 TR / 3 TR capacity any make and any model of split type AC including taking down unserviceable timer etc., complete all as specified and as directed. |
| 19 | Supply and fixing in repair blower motor double shaft, single/double speed, single phase, AC 230 V as per existing size (in hp ) capacity to suit the existing window type AC of upto 2 TR all as directed. [Make: As per OEM] complete as specified and directed. |
| 20 | Supply and fixing in repair blower motor single shaft, single/double speed, single phase, AC, as per existing size (in hp ) capacity to suit the out door unit of split type AC of upto 2 TR all as directed. [Make: As per OEM] complete as specified and directed. |
| 21 | Supply and fixing in repair blower motor single shaft, single/double speed, single phase, AC, 230 V suitable for indoor unit of split type AC of 1.5/ 2.0 TR capacity all as directed. [Make: As per OEM] complete as specified and directed. |
| 22 | Supply and fixing in replacement of front grill of existing window type AC upto 1.5 TR as per existing all as specified and directed. |
| 23 | Disconnecting and taking down unserviceable thermostat from window /split type air-conditioner up to 2 TR capacity, supply and fix new thermostat, testing and commissioning the same for satisfactory performance complete all as specified and directed. |
| 24 | Supply and lay PVC insulated cable flexible type with copper conductor 4 sq mm 3 core suitable for window/split type air-conditioner up to 3 TR capacity of length 3 mtr all as specified and as directed. |
| 25 | Opening dismantling and removing the indoor unit of split air conditioner ofcap 1.5 /2 TR and supply & fix new indoor unit of split air conditioner of 1.5 complete with making all connection including taking out old unsv indoor unit of 1.5/ 2.0 TR complete all as specified and directed. |
| 26 | Opening dismantling and removing the indoor unit of split air conditioner of cap 2 TR and supply & fix new indoor unit of split air conditioner of 2 TR complete with making all connection including taking out old unsv indoor 2 TR complete all as specified and directed. |
| 27 | Supply & Charging refrigerant gas R-32 /407A/134a. |
| 28 | Supply & fix in replacement of compressor oil servo friz F-68 of Indian oil or equivalent in BPCL/HPCL,complete all as specified |
| 29 | Supply and fix in repair with new complete outdoor unit of capacity 1.5 ton Hot/Cold with condensor coil, blower motor single phase, compressor including connection with connection of copper tubing suction / discharge complete all as specified and directed. Note:-Rate of refrigerant Gas charge and paid separately in relevent item. |
| 30 | Supply and fix in repair with new complete outdoor unit of capacity 2 ton Hot/Cold with condensor coil, blower motor single phase, compressor including connection with connection of copper tubing suction / discharge complete all as specified and directed. Note:-Rate of refrigerant Gas charge and paid separately in relevent item. |
| 31 | Supply & fixing in repair PVC Pipe of 65 mm dia of density 6kg/mtr for fixing between indoor and out door units inside the walls of appropriate lengths and closing the balance holes with PCC/Birla white/Glass putty and making the surface finishes even as directed by the engineer in charge. |
| 32 | Supply and fix in repair of Outdoor unit body cover suitable for existing model of Split AC of capacity 1.5/ 2.0 TR including removing of old rusted/ unserviceable body cover and taken as credit complete with all necessary requisite spares as required all as specified and as directed |
| 33 | M & L for Removing old rusted outdoor unit split air conditioner stand upto 2 TR from the existing site and supply and fix new stand made of mild steel as per existing without disturbing/damage the copper piping etc all as specified and directed. |
| 34 | Supply and Gas charging Nitrogen gas in manufacturer's sealed cylinder for leak testing. [Note:- (i) Empty cylinder will be returned to contractor on completion of work. (ii) Net weight of refrigerant gas shall be measured and paid.] |
| 35 | Supply and fix in repair renewal of sealed unit Compressor of water cooler suitable for 40/80 to 120/180 ltr capacity complete as specified and directed. Note:-Rate of refrigerant Gas charge mesured and paid separately in relevent item. |
| 36 | Servicing the Voltage Stabilizer upto 5 KVA single phase of make - Soft line or equivalent after strip opening covers, taking out the burnt out winding from the transformer rewind with super enamelled copper winding wire, insulate properly, setting/testing of buck/boost relay, replacement of U/S electronic parts, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed. |
| 37 | Supply and fixing in replacement of relay for automatic voltage corrector capacity upto 5 KVA, 230V AC suitable for existning make at site. |
| 38 | Supply and fixing in replacement of Electronic PCB for voltage stabilizer upto 5 KVA, 230V AC as per existig make at site. |
| 39 | Supply and fixing in replacement of trigger transformer of voltage stabliser of cap upto 5 KVA including making all connection suitable for existing make at site. |
| 40 | S&F in repair of High/ low cut off with time delay circuit suitable for upto 5 KVA capacity Voltage stabilizer complete all as specified and directed. |
| 41 | S&F 4 kVA automatic line Voltage stabilizer, single phase, naturally air cooled, wall mounted, indoor type, designed to give output voltage 225V +1.1% at input range between 140 to 280 Volts, with digitally displayed features, high and low cut of range voltage and time relay of 2 to 3 minutes on initial startcomplete all as specified and directed.Note :- Old U/S Voltage stabilizer taking down and Deposite to MES yard/store. |
| 42 | S&F for Replacementof 5 KVA automatic line Voltage stabilizer, single phase, naturally air cooled, wall mounted, indoor type, designed to give output voltage 225V +1.1% at input range between 140 to 280 Volts, with digitally displayed features, high and low cut of range voltage and time relay of 2 to 3 minutes on initial startcomplete all as specified and directed. Note :-Old U/S Voltage stabilizer taking down and Deposite to MES yard/store. |
| 43 | Supply and fix MCB SP 32 Amps 16 KA including taking out unserviceable MCB etc all as directed. |
| 44 | Supply & fixing in repair metal plug top 15 Amps complete All as specified and directed. |
| 45 | Supply and fixing in repair remote control complete suitable for existing model of split type AC of any capacity. [Make: As per OEM] complete all as specified and directed. |
| 46 | Walk-in-Cooler :- Supply and fixing in repair of compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection making all existing connection complete all as directed for 5 Ton indoor type Walk-in-cooler including taking out old us compressor complete all as specified and directed. (Note: Refrigerant gas supplied and charged shall be measured and paid separately). |
| 47 | M&L for Taking down of walkin-cooler 5 Ton capacity ton capacity and cleaning / servicing of walkin-cooler, overhauling of blower motor replacement of worn out parts, preparation of body for painting one coat of black paint inner side and one coat synthatic enameled paint on the outer cover of walkin-cooler and writing of SM/MES No and testing of full load of under relevent item of schedule 'A' and reinstallation at site.Note : Worn out parts shall be measured & paid seperately. |
| 48 | S&F in repair Blower motor working on single phase 230 V AC supply with base / rubber bush suitable for for walk-in - cooler of capacity 5 TR, all as complete specified and directed. |
| 49 | S & F in repair Controller/PCB Card Any make / any model for walk-in - cooler any capacity all as complete specified and directed. |
| 50 | S & F in repair Inlet sensor for indoor of walkin-cooler all as complete specified and directed. |
| 51 | S & F in repair Sensor for room/outlet/midlet of walkin-cooler all as complete specified and directed. |
| 52 | S & F in repair of Bimetal over load relay suitable for , Direct Mounting on ML Contactors, (Directly Operated) range up to 32 Amps to match with the existing for walk-in - cooler all as complete specified and directed. |
| 53 | S & F in repair High pressure and low pressure control (HP&LP) switch for F-22 for walk-in - cooler all as complete specified and directed. |
| 54 | Taking down existing U/S ceiling fan of 1200/1400 mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled copper winding wire, insulation, varnishing, greasing and assemling the fan with 2.5MFD capcacitor including replacement of ball bearing and connection wire upto ceiling rose 1.5 metre, cleaning, painting and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose and replacement of mild steel clamps and S hook including taking out old unsv fan complete all as specified & directed. |
| 55 | Taking down existing serviceable ceiling fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, checknuts, pin etc. and re-assembling and refixing in position , connecting and testing complete all as specified. |
| 56 | Taking down existing unserviceable exhaust fan of 450mm/380mm/300mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled copper winding wire, insulation, varnishing, greasing and assemling the fan with 2.5MFD capcacitor including replacement of ball bearing gun metal bush and connection upto 1.5 metre , cleaning, painting and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose including taking out old unsv exhaust fan complete all as specified & directed. |
| 57 | Taking down existing serviceable Exhaust fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, check nuts, pin etc. and re-assembling and refixing in position, connecting and testing complete all as specified. |
| 58 | Taking down of existing U/s exhaust fan plastic body 250mm and S&F exhaust fan plastic body 250mm sweep in replacement including making connections with suitable size of copper wire and making good surfaces complete all as specified. |
| 59 | Taking down of existing unserviceable ceiling fan and Supply and fixing BLDC ceiling fans with remote complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) Complele all as specified and directed. Old ceiling fan shall be deposit to MES store yard |
| 60 | Taking down of existing U/s wall fans and S&F 400 mm sweep BLDC wall mounting fan 400 mm sweep BLDC in replacement including making connections with suitable size of copper wire and making good surfaces complete all as specified and directed. Old wall fan shall be deposited to MES store yard |
| 61 | S&F,in repair Condensor / Capacitor, 240V, AC, suitable for fans and exhaust fan of 2.5 Mfd to 4 Mfd complete all as specified & directed. |
| 62 | S&F,in repair Fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fans any type, any make, any size complete all as specified & directed |
| 63 | S&F, in repair Down rod, suitably threaded and holed, made out of 15mmdia GI tubes, duly painted, suitable for ceiling fans of size 300 mm to 600 mm long any type, any make, any size all as directed. |
| 64 | All as per above item no. 63 but 900mm long |
| 65 | All as per above item no. 63 but 1800mm long |
| 66 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300MM sweep with, blades, and frame and louvers all as specified and directed. |
| 67 | S & F in replacement of PVC desert cooler operating on single phase 230V , 50 Hz with a high-torque, 100% copper-wound high efficient motor featuring Thermal Overload Protection (TOP), driving an aerodynamically designed fan capable of delivering a minimum air displacement of 5500CUM per hour suitable for air through upto 650 SQft with 100 ltr tank capacity with High-Density Honeycomb Pads: Equipped with an wide ice chamber and high-density honeycomb pads , the cooler ensures to throw cool air with a boost of ice like cooling and superior comfort for a longer period with stand free on roller mounting with min dimensions of cooler: 47D x 70.5W x 123.5H Centimeter setc all as specified and directed. |
| 68 | DESERT COOLER:- M&L for Replacement of defective burnt exhaust kit fan motor of 1/1.5 HP, any sweep and of any make and transporting to contactor's workshop, opening of motor taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled aluminium winding wire including insulation varnishing, greasing, reassembling testing and fixing in position all as directed. |
| 69 | S&F for Replacement of kit fan motor, single phase, 230 volt AC, 1/5 HP, complete with blade arm 20\\" sweep size, fixing lungs, nuts, bolts and washers suitable for desert cooler complete all as specified and directed. |
| 70 | S&F for Replacement of submersible mini water lifting pump, single phase, 230 volt AC, 50 HZ, 1/40 HP ( 18 watts approx), of 5 meter head complete all as specified and directed. |
| 71 | M&L for Spray painting of desert cooler body of any size internally and externally after scrapping out the existing paint with one coat of synthetic enamel paint on outer surfaces and one coat of anticorrosive paint on inner surfaces complete all as specified and directed. |
| 72 | M&L for Replacement of Front grill of Desert cooler of any size of suitable guage complete as directed |
| 73 | M&L for Replacement of control/ selector switch, 3 speed with knob suitable for desert cooler all as directed |
| 74 | M&L for Renewal of wood wool pad suitable for desert cooler complete all as specified and directed. |
| 75 | S&F for Replacement of PVC pipe 15mm dia, medium quality for desert cooler complete all as specified and directed. |
| 76 | M&L for Renewal of desert cooler body of size 1Mx1Mx1.2M, suitable for 450 mm/500 mm sweep exhaust fan /kit, made out of 18gauge PGI sheet and side panels duly filled with Khas khas including painting the inner surafces with one coat of anticorrosive paint and outer surfaces with two coats of synthetic enamel paint over a coat of primer, deassembling the fan, pump and its connected fittings, grills, regulator and cable etc.from wornout body and fixing the same in renewed Cooler Body complete all as specified and directe. |
| 77 | M&L for Renewal of desert cooler side panels of desert cooler, made out of 22 gauge PGI sheet and side panels duly filled with Ghas including painting the inner surafces with one coat of anticorrosive paint and outer surfaces with two coats of synthetic enamel paint over a coat of primer to match with the Body of desert cooler complete all as specified and directe. |
| 78 | DEEP FREEZER:-M&L for Replacement of harmertically sealed unit Compressor suitable for 320/500 litres capacity DEEP FREEZER of duly including necessary brazing work to make the system leak proof including taking out old U/S compresssor complete all as specified and directed. Note:-Rate of refrigerant Gas charge mesured and paid separately in relevent item. |
| 79 | M&L for Servicing /Cleaning of Deep freezer with Potassium permanganet solution after removing all dust, mud particles complete all as specified. |
| 80 | REFRIGERATOR:-M&L for Replacement of hermertically sealed unit Compressor suitable for 315/320 litres capacity Refrigerator duly including necessary brazing work to make the system leak proof including taking old U/S compresssor complete all as specified and directed.(Note: Rate of refrigerant Gas charge mesured and paid separately in relevent item. |
| 81 | M&L for Replacement of hermertically sealed unit Compressor suitable for 165/185 litres capacity Refrigerator duly including necessary brazing work to make the system leak proof, including taking old U/S compresssor complete all as specified and directed. (Note: Rate of refrigerant Gas charge mesured and paid separately in relevent item.). |
| 82 | M&L in repair of Liquid line filter for refrigerator of any capacity any make/model complete all as specified and directed. |
| 83 | S&F in repair PVC bottle guard suitable for 165 to 320 Ltr complete all as specified and directed. |
| 84 | S&F in repair chilled tray plastic for suitable for any make/ any model/ any capacity refrigerator complete all as specified and directed. |
| 85 | S&F in repair of freezer cabinet with door comprising spring suitable for any make/modle/capacity refrigerator complete all as specified and directed. |
| 86 | S&F in repair of condensing coil made of copper of any capacity refrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as specified and directed.Note: Rate of refrigerant Gas charge mesured and paid separately in relevent item). |
| 87 | M& L for Opening and dismantling of the geyser 25/35/50 ltr capacity and taking out inner tank and glass wool from inside the geyser for descaling and washing with acid to remove the scale, dirt etc if any and re-fixing the same after re-assemble into the geyser and proper filling of glass wool around inner tank complete all as specified and directed. Note :-Glass wool will be paid separately under respective item of Sch 'A' as 'supply only'. |
| 88 | Supply in replacement heating element 2 KW of storage type water heater of compatible type (Triangular /round) or as per existing including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements all as directed by Engineer-in-Charge of capacity ISI Marked : Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender