Science and Technology Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57065834

Tender For Renovation Of Birac-Bionest Incubation Centre (Phase-Ii) At Csir-Cftri, Mysuru

Issued by Statutory Bodies & Commissions/Committees · Mysuru, Karnataka
Tender Value
10.89 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
5 days left
EMD
21800
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mysuru → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Birac-Bionest Incubation Centre (Phase-Ii) At Csir-Cftri, Mysuru

BOQ

Name of Work:- Renovation of BIRAC-BioNEST Incubation centre (Phase-II) at CSIR-CFTRI, Mysuru
Sl. No. Item Description
1Part A: Civil Works
2Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
4Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
6Coursed rubble masonry (second sort) with hard stone in foundation & plinth with :Cement mortar 1:6 (1 cement : 6 M sand)
715 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 M sand)
8Extra for addition of synthetic Polyester triangular fibre of length 6 mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement plaster/mortar by using 125 gms. of synthetic Polyester triangular fibre for 50 Kgs. cement used in cement mortar as per directions of Engineer-in-Charge.MAKE: RECRON 3S (RELIANCE)
9Cement concrete flooring 1:2:4 (1 cement : 2 M sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 M sand: 8 graded stone aggregate 40 mm nominal size derived from natural sources)
11Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:1½:3 (1 cement : 1½ M sand: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
12Providing and fixing precast cement concrete solid block of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) -2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
13Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubesMAKE: TATA/ APOLLO/ SAIL
14Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.MAKE: JSW/ TAT A
15Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.MAKE: TATA/ APOLLO/ SAIL
16Providing and fixing below counter wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar tapsMake : Cera or Hindwdare or Parryware
17Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 M sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby redArea of slab over 0.50 sqm
18Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe32 mm dia
19Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall20 mm nominal dia PipesMAKE: SUPREME/ ASHIRWAD/ ASTRAL
20Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
21Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore
22Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal boreMAKE: ONIDA
23Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal boreMAKE: ONIDA
24Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
25Extra for depth beyond 45 cm of brick masonry chamber :For 455x610 mm sizeWith common burnt clay F.P.S. (non modular) bricks of class designation 5.00
26Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 M sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 M sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 M sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 M sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 5.00
27Providing, laying and jointing PVC pipes of 4 kgf/ sq.cm pressure capacity including testing of joints etc., complete63 mm diameter Make: ASHIRWAD/ FINOLEX/ SUPREME
28Providing, laying and jointing PVC pipes of 6 kgf/ sq.cm pressure capacity including testing of joints etc., complete110 mm diameter Make: ASHIRWAD/ FINOLEX/ SUPREME
29Providing and fixing of SWR nahani trap 110 mm dia including adhesive completeMAKE: SUPREME/ ASTRAL/ ASHIRWAD
30Providing and fixing 110 mm SS grating with holeMake: ASHIRWAD/ FINOLEX/ SUPREME
31Providing and fixing factory made uPVC glazed/ wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles having minimum wall thickness of 1.70mm for series R1 & R2 profiles and 2.10 mm for series R3 and R4 profiles conforming to EN: 12608 in any shape colour and design duly reinforced with galvanized mild steel section made of required shape and size as per CPWD specification, uPVC extruded glazing beads, interlocks and inline sas adaptor (where ever required) of appropriage dimension, EPDM gasket, hardware SS 304 grade fasteners of Minimum 8mm dia with counter sunk head, comprixing of matching polyamide PA6 grade sleeve for fixing frame to finished wall as pr IS1367: PART 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/ mechanically jointed duty sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc., After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specificaton and direction of Engineer-in-charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-charge.Wire mesh/ Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS:3548 & IS:16231 shall be paid separately.Note: Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for:(i) Sites with basic wind speed >45 m/ sec as per IS875 - part3(ii) sits with structure height morethan 20m for all wind speedstwo track two panels sliding window with aluminium channel for roller track, wool pile, nylon rollers with SS304 body.Using R2 series with frame (40mm and above) x (40mm and above) and sash (25mm x above) x (50mm & above) with zinc alloy (Zamak) powder coated touch locks with hook (Height upto 1.2 metre)Make: LG / NCL VEKA/ Komarling
32Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new workMAKE: asian - apcolite gloss enamel OR Nerolac – synthetic enamel OR Dulux - Gloss enamel
33Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead for all lead upto 10 kms including all lifts involved.
34Part B: Electrical Works
35Supplying, Installation, Testing & Successful Commissioning of 5 Watts, LED Batten Light (light colour as per choice of Engineer-Incharge), ready to use, complete with internal wiring, to fix with required length of any standard make rated 3 core copper wire, with suitable hardwares etc., to fix on wall surface / ceiling / cubical as per site requirement; to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting to be terminated to a 5 Amps Modular Switch. Make for All : Please refer Special Electrical Conditions under Tender Document File.
36Supplying, Laying and Termination of 3.5 Core X 25 Sq. Mm Armoured Copper Conductor LT Cable in Surface / Recess with medium class suitable size PVC conduit as required. Make for Cable & Pipe: Please refer Special Electrical Conditions under Tender Document File.. Note: All start & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size.
37Supplying, Installation, Testing & Successful Commissioning of 16 Modular GI Box along with Modular Base & Cover Plate for Modular Switches and Sockets in recess / wall using suitable hardwares etc. as required and as per directions of Engineer In-Charge and consisting of following Modular items a) 5/6 Amp Switch - 2 Nos; b) 6 Pin 5/6 Amp Socket Outlet - 2 Nos; c) 15/16 Amp Switch - 2 Nos; d) 6 pin 15/16 Amp Socket Outlet - 2 Nos and e) 32 Amps, 2 Pole, \\"C\\" Curve, 10kA, 230V Mini MCB - 1 No. Internal wiring for 5 Amps Switch & Socket with 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire; for 15 Amps Switch & Socket with 6.0 sq.mm FRLS Multistrand, Single Core Copper Wire. Red and Black Colour for Phase and Neutral and 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire, Green Colour for Earthing Loop and terminate all the wires using suitable size Copper Lugs as required. Make: Please refer Special Electrical Conditions under Tender Document File.
38Supply, Installation, Testing and Successful Commissioning of 25KVAR Capacitor Bank in the Mains Output using 6.0 sq.mm PVC Insulated Flexible FRLS / HFFR Copper Wire. Make: Please refer Special Electrical Conditions under Tender Document File.
39Supply, Installation, Testing and Successful Commissioning of 9 Inch Dia, 225mm / 230mm sweep, industrial type ready to use Exhaust Fan having Bird Cage with 1.5 FRLS PVC insulated, copper conductor, single core cable and to fix with required size of MS frame duly painted with one coat of primer and 2 coats of paint, suitable hardwares etc., and provide one no. of 3 Pin 5/6 Amps ISI make Socket along with Gangbox and 3 Pin 5/6A Amps ISI make Plugtop as required. Make: Please refer Special Electrical Conditions under Tender Document File.
40Single Door IP55 Indoor MCCB Box of size 15\\" (W) x 15\\" (H) x 15\\" (D), apprx 2 cuf, made out of 1.6mm thick CRCA sheet steel enclosure, painted with two coats of red oxide & two coats of enamel paint siemens grey colour and consisting of 1 No of 200A, 36KA Range 4P MCCB The Box should have provision for mounting on the wall with required hardware arrangements, locking arrangements for door, 2 Sets of RYB LED Indicating Lamps for Input & Output, 2 nos of earth bolts on either side of the box, 2 numbers of removable plate at the bottom of the box for Cable/Wire entry, water proof vents on both the sides covered with wire mesh from inside to avoid entry of any insects entering inside the box. To connect S.No.2.02 as input to the MCCB and the Input Wires of 2 x UPS in the Output Side respectively . Make: Please refer Special Electrical Conditions under Tender Document File. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker.
41Group A Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS / HFFR PVC insulated copper conductor single core cable etc., as required. Make: Please refer Special Electrical Conditions under Tender Document File.
42Group C Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS / HFFR PVC insulated copper conductor single core cable etc., as required. Make for all: Same as Item No: 2.07
43Supplying & drawing 2 x 1.5 sq.mm size of FRLS / HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. Make for all: Same as Item No: 2.07. Note: All start, loop & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size and individual pipes for wiring.
44Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make: Same as Item No: 2.07. Note: All start & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
45Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make: Same as Item No: 2.07. Note: All start & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
46Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make: Same as Item No: 2.07. Note: All start & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size.4 X 6 sq. mm + 2 X 6 sq. mm earth wire
47Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make: Same as Item No: 2.07. Note: All start & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size.4 X 10 sq. mm + 2 X 6 sq. mm earth wire
48Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Make: Same as Item No:2.03
49Supplying & Fixing DP sheet steel enclosure on surface / recess along with 32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. Make: Same as Item No:2.06
50Supplying and fixing TP sheet steel enclosure on surface / recess along with 32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. Make:Same as Item No:2.06
51Supplying and fixing 30A, 415V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioing etc. as required. Make:Same as Item No:2.06
52Supplying, Installation, Testing & Commissioning of 100 Watt Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 Deg C to 50 Deg C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Make: Please refer Special Electrical Conditions under Tender Document File. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57065834
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10.89 Lakhs
LAST DATE 29-08-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Renovation Of Birac-Bionest Incubation Centre (Phase-Ii) At Csir-Cftri, Mysuru
Basic Detail
Tender No E/CW/005/1128/2026-27
Bidding Type Tender
Location
City Mysuru
State Karnataka
Key Dates
Publish Date 18 Aug 2026
Submission Date 29 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 10.89 Lakhs
Tender Fee Ref. Documents
EMD 21800
Exemption Not Available
Document List
BOQ_335902.xls
e34c4417-8246-4f32-98b6-b15469f570d3.html
Electrical_Conditions.pdf
TEN005CW202627.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_335902.xls

html

e34c4417-8246-4f32-98b6-b15469f570d3.html

pdf

Electrical_Conditions.pdf

pdf

TEN005CW202627.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders