Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #57065700

Tender For Repairs To Various E/M Related Items To Certain Bldg And Hangars In Aor Of Army Avn Sqn And Caats In Aop Area Under Ge Nrc

Issued by Statutory Bodies & Commissions/Committees · Nashik, Maharashtra
Tender Value
38 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
16 days left
EMD
76000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs To Various E/M Related Items To Certain Bldg And Hangars In Aor Of Army Avn Sqn And Caats In Aop Area Under Ge Nrc

BOQ

Name of Work:- REPAIRS TO VARIOUS E/M RELATED ITEMS TO CERTAIN BLDG AND hangarS IN AOR OF ARMY AVN SQN AND CAATS IN AOP AREA UNDER GE NRC
Sl. No. Item Description
1Notes for Item No.1 & 21(i) All the defective Spares / Material required will be measured and paid seperately.(ii) After each service of each door signature of users must be obtaied for satisfactory working and submited before claiming payment.(iii) Contractor should attend the complaint immediately, when notified by Dept if the door fails to work During the Contrcat Period(iv) Contrcator has to arrange the Complait Book and to be submitted duly signed from User after attendeing the same(v) The complaint should be attended by the contractor on the same day when notified, failing which Rs1,500/- per day per complaint will be cahrged.(vi) T&P required for repair / testing shall be included in the quoated rates
2M&L for carrying out Preventive Maintenance Quarterly for \\"SUNRISE MAKE\\" MOTORIZED DOOR- Half Opening : Size : 16m width, 10m height Installed at New hangar = 2 doors, P-145 = 1 door, P-135 = 1 door which includes the following:-(a) Check All connections of conductors at main distribution box are properly conneccted.(b) Check all conductors from main distribution box to electric motor, must not weak or burnt or damaged insulation.(c) Check total electrical panel cabling, must not weak or burnt or damaged insulation.(d) Check all Miniature circuit brakers, must not have loose contact or damaged, must be functioning properly(e) Check all components in electrical panel like RYB indicators, Emergency stop, Push buttons for forward & reverse motion, contactor, Buzzer, O/L relay etc. must have proper connections, functioning properly.(f) Check all joints of electrical conductors, must be tight properly with lugs & fastners.
3(g) Check Electrical panel box, check locks & fastners properly tight, make it dust & insects free.(h) Check wire rope mountings, wire rope, cable conductors, cable collector, check welding, check fastners, lubricate cable collector wheel, check electrical festun conductor, for proper functioning.(j) Check guide rollers assembly (i.e. wheel, shaft cirlips, fasteners & self lubricating bearings) check mounting fastners tigtness & alignment. Check clearance between guide rail & rollers.(k) Check fixings of all conduites, MCBs, electrical panel & machine cover. Tight all fastners properly.(l) Check Drive motor- all fastners, terminal box connections, earthing, starting & running current rating, noice, temperature, overload, speed, fan & ventilation.(m) Check worm gearbox- all fastners, any leakage of lubricant, seals, lubricant level, lubricant viscosity, noice of worm & worm wheel meshing, output shaft position, cirlips, extended shaft alignment, key, temperature.(n)Check chain sprockets- tooth must not be grinded above 20%. Alignment & parallelism of sprockets, fastners & key. Check Chain slippage or noice .(o) Check chain- Tight chain suitable to function, extension of chain is allowed max. 3%; so check pitch of tooth & chain links. Check chain lock properly installed, Lubricate chain & sprockets by Spheerol EPL 2 (EN - SDS)(p) Check drive and driven wheels assemblies- check traid diameter & traid width of wheel, wearout must be less than 15%. Check bearings, circlips, axels, fastners, spacers & alignment.
4(q) Check Corrugated precoated color sheets- check by noise or vision all self tapping screws, tight if any loose. Attach a same sheet patch at any tored sheet. Seal holes by sealing agent. (r) Check Door panel structure- Check flatness & in a plane, any welding crack, all structural members in position, color damage, machine base frame structure, rail & panel gap & parallelism.(s) Check Bottom Rail & top guide rail- check for top & bottom rail welding crack if any, weld it. Clean Bottom rail. Check Flatness, parallelism equal clearance in guide angles, dent or bend of botom rail if any, grind it & make smooth.(t) Submission of report as per above (a) to (s) duly signed by the contractor and user.
5Supply only galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour (as per existing) having tensile strength of 550 mPa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
6Supply only cantilever roller with self lubricating frictionless bearings (rollers and bearings of existing size suitable for existing door)
7Supply only chain and locking arrangement as per existing size and material.
8Supply only axel, bearings, circlip assembly complete as required at site.
9Supply only pair of chain & drive sprocket complete as required at site.
10Supply only cable Collector & wire rope Assembly complete as required at site.
11Supply only main power supply copper flexible cable of size 2.5 Sqmm x 4 core, FRLSH, unarmoured complete.
12Supply only main power supply copper flexible cable of size 1.5 Sqmm x 4 core, FRLSH, unarmoured complete.
13Supply only motor & speed reducer cover complete as required at site.
14Supply only Miniature circuit braker (MCB) 415 Volts 4P MCB 5SL63107RC, 6 to 32 Amps.
15Supply only 3TF34 contactor with aux. cont. block- Siemens or equivalent.
16Supply only overload relay 3UA5000-1J OLR (6.3-10 A) Siemens or equivalent.
17Supply only contactor with buzzer- 220V-completed all as directed.
18Supply only forward reverse push buttons 3SB5000 with NO/NC- Siemens.
19Supply only emergency P/B 3SB5000-0UC01- Siemens or equivalent
20Supply only indicator R/Y/B 220V- completed all as directed
21Supply only limit switch ID8108 completed all as directed
22M&L for Rewinding the motor (3.75 kW/5HP) with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed. (Note:- cost of transportation included in quotated rates)
23Carrying out Inspection of Motorised Door Size: 16m width, 10m height by Govt approved Chartered Engineer after its repair and submit necessary certification (from same charted Engineer) for its working condition after satisfying all the parameters as directed.(Note: The Contractor should submit Govt. authorized charted engineer certificate)
24M&L for for carrying out Preventive Maintenance Quarterly for \\"SUNRISE MAKE\\" MOTORIZED DOOR- Half Opening : Size : 36m width, 9m height Installed at P-46 = 1 door, P-25 = 1 door which includes the following:-(a) Check All connections of conductors at main distribution box are properly connected.(b) Check all conductors from main distribution box to electric motor, must not weak or burnt or damaged insulation.(c) Check total electrical panel cabling, must not weak or burnt or damaged insulation.(d)Check all MCBs, must not have loose contact or damaged, must be functioning properly(e) Check all components in electrical panel like RYB indicators, Emergency stop, Push buttons for forward & reverse motion, contactor, Buzzer, O/L relay etc. must have proper connections, functioning properly.(f) Check all joints of electrical conductors, should tight properly with lugs & fastners.(g) Check Electrical panel box, check locks & fastners properly tight, make it dust & insects free.(h) Check wire rope mountings, wire rope, cable conductors, cable collector, check welding, check fastners, lubricate cable collector wheel, check electrical festun conductor, for proper functioning.(j) Check guide rollers assembly (i.e. wheel, shaft cirlips, fastners & self lubricating bearings) check mounting fastners tigtness & alignment. Check clearance between guide rail & rollers.
25(k) Check fixings of all conduites,MCBs, electrical panel & machine cover. Tight all fastners properly.(l) Check Drive motor- all fastners, terminal box connections, earthing, starting & running current rating, noice, temperature, overload, speed, fan & ventilation.(m) Check worm gearbox- all fastners, any leakage of lubricant, seals, lubricant level, lubricant viscosity, noice of worm & worm wheel meshing, output shaft position, cirlips, extended shaft alignment, key, temperature.(n)Check chain sprockets- tooth must not be grinded above 20%. Alignment & parallelism of sprockets, fastners & key. Check Chain slippage or noice .(o) Check chain- Tight chain suitable to function, extension of chain is allowed max.3%; so check pitch of tooth & chain links. Check chain lock properly installed, Lubricate chain & sprockets by Spheerol EPL 2 (EN - SDS)(p) Check drive and driven wheels assemblies- check traid diameter & traid width of wheel, wearout must be less than 15%. Check bearings, circlips, axels, fastners, spacers & alignment.
26(q) Check Corrugated precoated color sheets- check by noise or vision all self tapping screws, tight if any loose. Attach a same sheet patch at any tored sheet. Seal holes by sealing agent. (r) Check Door panel structure- Check flatness & in a plane, any welding crack, all structural members in position, color damage, machine base frame structure, rail & panel gap & parallelism.(s) Check Bottom Rail & top guide rail- check for top & bottom rail welding crack if any, weld it. Clean Bottom rail. Check Flatness, parallelism equal clearance in guide angles, dent or bend of botom rail if any, grind it & make smooth.(t) Submission of report as per above (a) to (s) duly signed by the contrcator and user.
27Supply only cantileaver roller with self lubricating frictionless bearings (rollers and bearings of existing size suitable for existing door) complete
28Supply only chain and locking arrangement complete as required at site
29Supply only wheels complete as required at site
30Supply only axel, bearings, circlip assembly complete as required at site
31Supply only pair of chain & drive sprocket complete as required at site
32Supply only Driven sprocket complete as required at site
33Supply only worm speed reducer complete as required at site
34Supply only cable Collector & wire rope Assembly complete.
35Supply only cable carriers complete
36Supply only motor & speed reducer cover by assembly complete as required at site
37Carrying out Inspection of Motorised Door Size : 36m width, 9m height by Govt approved Chartered Engineer after its repair and submit necessary certification (from same charted Engineer) for its working condition after satisfying all the parameters as directed.(Note: The Contractor should submit Govt. authorized charted engineer certificate)
38Taking down/dismantling/handing of ceiling fan (1200/1400mm sweep) segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape, Rotter soft etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spare parts, painting and necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and including supply and fixing the following items (Split pin - 02 Nos, Connection block - 1 No and Insulation rubber bush - 01 No, Condensor-01 No, bearing- 01 or 02 Nos, gun metal bush-01 No if required) including necessary transportion to workshop.
39Taking down/dismantling/handing of Exhaust fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape, Rotter soft etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spare parts, painting and necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and including supply and fixing the following items (Split pin - 02 Nos, Connection block - 1 No and Insulation rubber bush. - 01 No, Condensor-01 No, bearing- 01 or 02 Nos, gun metal bush-01 No if required) and including necessary transportion to workshop for 225mm, 250mm, 380mm, 450mm sweeps.
40S&F bearing for ceiling fan (Bearing No.6201 Z Type).
41S&F bearing for ceiling fan (Bearing No.6202 Z Type).
42S&F bearing for ceiling fan (Bearing No.6203 Z Type).
43S&F bearing for ceiling fan (Bearing No.6204 Z Type).
44S&F in repair and connecting up flexible copper cable twin core of 0.75 Sqmm.
45S&F in replacement offload change over switches in sheet metal enclosure 4 pole, 63 Amps complete all as directed.
46S&F in replacement offload change over switches in sheet metal enclosure 4 pole, 100 Amps complete all as directed.
47S&F in replacement onload change over switches in sheet metal enclosure 4 pole, 125 Amps complete all as directed.
48S&F in replacement onload change over switches in sheet metal enclosure 4 pole, 630 Amps complete all as directed.
49S&F test and commissioning Low Intensity LED Aviation Obstruction Light, 8 W steady burning red colour, suitable for obstruction marking of buildings, towers and other elevated structures, complete with automatic dusk-to-dawn operation through inbuilt LDR sensor, weather proof housing of protection class IP 65 or better, suitable for operation on 230V AC supply, including mounting arrangement, connection to existing wiring, fixing hardware, glands, lugs, earthing and all accessories required for complete installation and satisfactory operation, complete in all respects.
50S&F in replacement of main power supply copper Cable of size 2.5 Sqmm x 3 core, FRLSH, armoured complete including necessary clamping all as directed (For AVN Light cable)
51S&F VTPN MCCB DB prewired made of sheet metal powder coated suitable for surface mounting with 250A copper bus bar for each phase with 2 neutral bar & 2 earth bar cable ties for cable management, fully insulated bus bar & shrouded neutral bar, pmproved pan assembly for ease of installations, prefitted masking sheet, reversible door for IP 43 DBs with provision for incoming MCCB & outgoing MCBs with IP-54-IK09 protection grade, 415 Volts TPN with 8 way Double door all as specified & as directed
52S&F in repair F MCB DB made of sheet metal powder coated with acrylic door suitable for surface mounting with 100A copper bus bar for each phase with neutral bar & earth bar cable ties for cable management, fully insulated bus bar & shrouded neutral bar, pmproved pan assembly for ease of installations, prefitted masking sheet, reversible door for IP 43 DBs with provision for incoming MCB & outgoing MCBs with IP-43-IK09 protection grade, 415Volts TPN with 4 way double door all as specified & as directed
53S&F LED flame proof Batten 40 Watt (tube light fixtures) suitable for illuminating hazardus area laden with gases or vapours complete all as specified and as directed.. Make: Crompton Cat No-EXTN2LT8-16/20-VE or equivalent model in other makes as per PS.
54S&F in repair MCCB TPN, 4 Pole 125A, 415V, breaking capacity 16kA, adjustable tripping, suitable for isolation complete all as specified and as directed.
55S&F in repair MCCB TPN, 4 Pole 63A, 415V, breaking capacity 16 kA, adjustable tripping, suitable for isolation complete all as specified and as directed
56S&F in repair MCCB TPN 100 Amp, 4 pole, 415 Volts 16 kA adjustable tripping, suitable for isolation complete all as specified and as directed
57M&L for earthing with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connecting to the GI strip 32x6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC 1:2:4, type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 m, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified, testing on completion including taking down old earthing complete all as specified and directed.
58S&F GI strip 32x6mm with saddles and fixing screws etc. complete all as specified and directed.
59M&L for repairs to LT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and aldrop of suitable size bolt complete and painting with two coat of synthetic enamel paint of approved color internally and externally all as specified and as directed.Note : (i) Rate for requisite stores i.e. hinges, welding rods, paint, primer, included in this item rate.(ii) All types of T&P i.e. welding machine at site, compressor for spray paint etc. included in this item.(iii) If Panel repair work has not been started by the Contractor after receiving of site order/instructions from Engr-in-Charge, Penalty for Rs. 1,000.00 per day will be recovered from the Contractor.
60Supply and joint in repair of cable jointing kit straight through joint epoxy type of size 70/95 sqmm 3.5 all as specified and directed. Make : Denson, Raycom
61Supply and joint cable jointing kit straight through joint epoxy type of size 10 sqmm 4 core to 16 sqmm 4 core all as specified and directed. Make : Denson, Raycom
62Supply and joint cable jointing kit straight through joint epoxy type of size 25 sqmm 3.5 core to 50 sqmm 3.5 core all as specified and directed. Make : Denson, Raycom
63Supply, install, test and commissioning (CPRI Approved) factory fabricated, outdoor type, LT panel board made out of 3.00 mm thick CRCA Sheet with dust and vermin proof double door with front side openable,including neoprene rubber gasket, suitable for 440 Volts, 3 phase 4 wire system, including Danger plate, Earthing Strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc and embadded with 50x50x6 mm MS angle iron frame and 600 mm above tne normal ground level complete with PCC foundation in cement concrete 1:3:6 (20mm graded aggregate) and testing after installation complete all as specified and comprising of following: (Loaction: P-145 hangar Sub station room)
64INCOMING :-(i) Bus bar chamber comparising 4 Nos Aluminium Strip bus bar (50x10) air insulated and PVC sheathed Capacity 500 Amps with colour coding in separate sheet enclsure(ii) MCCB with thermal based release 4 pole, 315 Amps, 50 Hz, 36 kA-01 No (I/C)(iii) Digital multi function panel mounted meter for energy monitoring to display Voltage, Current, Active power, reactive power, apperent power, power factor, frequency and all other parameter including necessary CTs, PTs and fuses and wiring-01 No(iv) LED type/neon type indicating lamp panel mounted type RYB-03 Nos(v) Single Phase preventer-01 NoOUTGOING :-(i) MCCB 4 pole 160 Amp 25 kA thermal based release - 02 Nos (ii) MCCB 4 pole 250 Amp 36 kA thermal based release - 02 Nos (iii) MCCB 4 pole 100 Amp 25 kA thermal based release - 02 Nos
65Supply, installation, testing and commissioning (CPRI Approved) factory fabricated outdoor type, LT panel board made out of 3.00 mm thick CRCA Sheet CRCA Sheet with dust and vermin proof double door with front side openable,including noprene rubber gasket, suitable for 440 Volts, 3 phase 4 wire system, including Danger plate, Earthing Strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc and embadded with 50x50x6 mm mild steel angle iron frame and 600 mm above normal ground level complete with PCC foundation in cement concrete 1:3:6 (20mm graded aggregate) and testing after installation complete all as specified and comprising of following: Location: Infront of TOK pump garrage
66INCOMING :-(i) Bus bar chamber comparising 4 Nos Aluminium Strip bus bar air insulated and PVC sheathed Capacity 400 Amps (40x10) with colour coding in separate sheet enclsure(ii) MCCB with thermal based release 4 pole, 250 Amps, 50 Hz 36 kA-01 No (I/C) (iii) Digital multi function panel mounted meter for energy monitoring to display Voltage, Current, Active power, reactive power, apperent power, power factor, frequency and all other paramater including necessary CTs, PTs and fuses and wiring-01 No(iv) LED type /neon type indicating lamp panel mounted type RYB-03 Nos(v) Single Phase preventer-01 NosOUTGOING :-(i) MCCB 4 pole 200 Amp 36 kA thermal based release - 01 Nos (ii) MCCB 4 pole 125 Amp 25 kA thermal based release - 06 Nos
67Supply, install, testing and commissioning (CPRI Approved) factory fabricated outdoor type, LT panel board made out of 3.00 mm thick CRCA Sheet with dust and vermin proof double door with front side openable, including neoprene rubber gasket, suitable for 440 Volts, 3 phase 4 wire system, including Danger plate, Earthing Strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc and embadded with 50x50x6 mm mild steel angle iron frame and 600 mm above normal ground level complete with PCC foundation in cement concrete 1:3:6 (20mm graded aggregate) and testing after installation complete all as specified and comprising of following: Location Bay service
68INCOMING :-(i) Bus bar chamber comparising 4 Nos Aluminium Strip bus bar air insulated and PVC sheathed Capacity 500 Amps (50x10) with colour coding in separate sheet enclsure(ii) MCCB with thermal based release 4 pole, 315 Amps, 50 Hz 36 kA-01 No (I/C) (iii) Digital multi function panel mounted meter for energy monitoring to display Voltage, Current, Active power, reactive power, apperent power, power factor, frequency and all other paramater including necessary CTs, PTs and fuses and wiring-01 No(iv) LED type /neon type indicating lamp panel mounted type RYB-03 Nos(v) Single Phase preventer-01 NoOUTGOING :-(i) MCCB 4 pole 200 Amp 36 kA thermal based release - 02 Nos (ii) MCCB 4 pole 100 Amp 25 kA thermal based release - 01 No
69Supply, installation, testing and commissioning (CPRI Approved) factory fabricated outdoor type, LT panel board made out of 3.00 mm thick CRCA Sheet with dust and vermin proof double door with front side openable, including noprene rubber gasket, suitable for 440 Volts, 3 phase 4 wire system, including Danger plate, Earthing Strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc and embadded with 50x50x6 mm mild steel angle iron frame and 600 mm above normal ground level complete with PCC foundation in cement concrete 1:3:6 (20mm graded aggregate) and testing after installation complete all as specified and comprising of following: Location Infront of P-135 hangar
70INCOMING :-(i) Bus bar chamber comparising 4 Nos Aluminium Strip bus bar air insulated and PVC sheathed Capacity 400 Amps (30x10) with colour coding in separate sheet enclosure(ii) MCCB with thermal based release 4 pole, 250 Amps, 50 Hz 36 kA-01 No (I/C) (iii) Digital multi function panel mounted meter for energy monitoring to display Voltage, Current, Active power, reactive power, apperent power, power factor, frequency and all other paramater including necessary CTs, PTs and fuses and wiring-01 No(iv) LED type /neon type indicating lamp panel mounted type RYB-03 Nos(v) Single Phase preventer-01 NoOUTGOING :-(i) MCCB 4 pole 125Amp 25 kA thermal based release - 03 Nos (ii) MCCB 4 pole 100Amp 25 kA thermal based release - 02 Nos
71Supply, installation, testing and commissioning (CPRI Approved) factory fabricated indoor type, LT panel board made out of 2.00 mm thick CRCA Sheet with dust and vermin proof double door with front side openable, including neoprene rubber gasket, suitable for 440 Volts, 3 phase 4 wire system, including Danger plate, Earthing Strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc and embadded with 50x50x6 mm mild steel angle iron frame and 600 mm above normal ground level complete with PCC foundation in cement concrete 1:3:6 (20mm graded aggregate) and testing after installation complete all as specified and comprising of following: Location Infront of P-135 hangar Inside
72INCOMING :-(i) Bus bar chamber comparising 4 Nos Aluminium Strip bus bar air insulated and PVC sheathed Capacity 200 Amps (20x10) with colour coding in separate sheet enclsure(ii) MCCB with thermal based release 4 pole, 125 Amps, 50 Hz 25 kA-01 No (I/C) (iii) Digital multi function panel mounted meter for energy monitoring to display Voltage, Current, Active power, reactive power, apperent power, power factor, frequency and all other paramater including necessary CTs, PTs and fuses and wiring-01 No(iv) LED type /neon type indicating lamp panel mounted type RYB-03 Nos(v) Single Phase preventer-01 NoOUTGOING :-(i) MCCB 4 pole 100 Amp 25 kA thermal based release - 02 Nos (ii) MCCB 4 pole 63 Amp 25 kA thermal based release - 04 Nos
73Supply, installation, testing and commissioning of TPN Distribution Board fabricated from CRCA sheet steel, dust and vermin proof, suitable for surface/recess mounting, complete with 125 Amp, 4 Pole MCCB incomer of 25 kA breaking capacity, copper busbars, neutral link, earth bar, interconnections, gland plate, cable terminations, painting and all accessories, complete including taking down old distribution board.
74Supply, install, testing and commissioning of Ray Matrix LED Flood Light fitting, 50W, suitable for operation on 240V AC, 50Hz supply, having RGBW (Red, Green, Blue & White) colour output, 15° beam angle, minimum IP66 protection, pressure die-cast aluminium housing with corrosion-resistant powder-coated finish, toughened glass diffuser, high-efficiency LED source, complete with integral LED driver, mounting bracket, all fixing accessories, interconnections and necessary hardware, conforming to relevant IS/IEC standards, as required complete all as directed.Make : Halonix Cat Ref : HLFLD-99-50-4CL-15D or equivalent model in other makes as per PS.
75Supply, install, testing and commissioning in repair Ray Matrix LED Flood Light fitting, 50W, suitable for operation on 240V AC, 50Hz supply, having RGBW (Red, Green, Blue & White) colour output, 45° beam angle, minimum IP66 protection, pressure die-cast aluminium housing with corrosion-resistant powder-coated finish, toughened glass diffuser, high-efficiency LED source, complete with integral LED driver, mounting bracket, all fixing accessories, interconnections and necessary hardware, conforming to relevant IS/IEC standards, as required complete all as directed.Make : Halonix Cat Ref : HLFLD-99-50-4CL-45D, or equivalent model in other makes as per PS.
76Supply, fixing, testing and commissioning in repair RGBW LED Round Spot Light, 12 Watt, suitable for operation on 24V DC supply, complete with high efficiency LEDs, die-cast aluminium housing, tempered glass lens, RGBW colour mixing, IP66 protection, mounting bracket, driver/control gear, connection accessories and all other associated works required for satisfactory performance, complete all as specified and as directed.Make: Halonix Cat Ref : HLSPL-R71-12-4CDL-NI-15D, or equivalent model in other makes as per PS.
77Supply, fixing, testing and commissioning of Premium Wall Baze 2 Linear LED Wall Washer fitting, 24 Watt, suitable for wall mounting and operation on 24V DC supply, complete with high-efficiency LEDs, RGBW colour output, beam angle 20° x 40°, extruded aluminium housing with corrosion-resistant finish, tempered/toughened glass cover, integral driver/control gear, mounting brackets, connection accessories and all other associated works, having minimum IP66 protection, complete all as specified and as directed.Make: Halonix Cat Ref : HLWWL-99-24-4CL-NI-20X40D, or equivalent model in other makes as per PS.
78Supply, Install, testing & Commissioning in replacement of U10 DMX Controller suitable for controlling RGB/RGBW LED lighting fixtures through DMX512 protocol, operating on DC 12V–24V supply, complete with microprocessor-based control unit, DMX512 signal processing, programmable scenes and effects, address setting facility, dimming control, communication ports, input/output terminals, protective enclosure, mounting accessories, interconnecting hardware, wiring connections, testing and commissioning as required for satisfactory operation, complete
79Supply, Install, testing and Commissioning of DMX 8-Port Splitter (Opto-Isolated) suitable for DMX512 lighting control systems, complete with 1 DMX input and 8 optically isolated DMX outputs, signal amplification and regeneration facility, DMX512/RDM protocol compatibility, electrical isolation between input and output ports, LED status indicators, rugged metal enclosure, XLR connectors, power supply unit, mounting accessories, interconnecting wiring, testing and commissioning, complete in all respects for satisfactory operation.
80Supply, laying, testing and commissioning of Belden make DMX Data Cable suitable for DMX512 lighting control applications, comprising 1 Pair × 22 AWG stranded tinned copper conductor, twisted pair with polyethylene insulation, overall aluminium/polyster foil shield with tinned copper drain wire, PVC/FRLS outer sheath, characteristic impedance 120 Ohms, low capacitance, suitable for transmission of DMX512 digital control signals between controllers, splitters and lighting fixtures, complete with all accessories, dressing, termination, testing and commissioning as required.
81Supply, install, testing and Commissioning in replacement of LED Driver / Constant Voltage Power Supply suitable for indoor/outdoor LED lighting applications, having input voltage 100–240V AC, 50/60 Hz and output voltage 24V DC constant voltage, rated output power 200 Watts, with high efficiency, overload protection, short-circuit protection, over-voltage protection and over-temperature protection, housed in a robust weather-resistant enclosure with minimum IP67 protection, complete with input/output terminals, mounting accessories, interconnections, testing and commissioning, complete in all respects as specified.
82Supply, fix, test and commissioning in repair waterproof connector suitable for end waterproof processing and termination of outdoor lighting power/data cables, comprising IP67/IP68 rated inline waterproof connector with high-strength UV-resistant engineering plastic body, silicone sealing rings, cable glands, corrosion-resistant copper alloy contacts, threaded locking arrangement and complete weather proof sealing system, suitable for LED wall washers, flood lights, spot lights and DMX control cabling, complete with all accessories, termination, sealing, testing and commissioning, ensuring reliable protection against water, dust and environmental conditions, complete in all respects.
83Supply, install, test and Commissioning in repair XLR Male to XLR Female DMX Patch Cable, 1.5 m long, suitable for DMX512 lighting control systems, comprising high-quality shielded twisted pair cable of 120 Ohm impedance, fitted with 3-pin/5-pin XLR male connector at one end and corresponding XLR female connector at the other end, complete with strain relief, corrosion-resistant contacts, moulded/metal connector body, cable identification, termination, continuity testing and commissioning, complete in all respects for reliable transmission of DMX control signals.
84NOTE: AMOUNT OF SCHEDULE OF CREDIT Rs. 85,588.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57065700
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38 Lakhs
LAST DATE 08-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs To Various E/M Related Items To Certain Bldg And Hangars In Aor Of Army Avn Sqn And Caats In Aop Area Under Ge Nrc
Basic Detail
Tender No GE/NRC/8837/E8
Bidding Type Tender
Location
City Nashik
State Maharashtra
Key Dates
Publish Date 18 Aug 2026
Submission Date 08 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 38 Lakhs
Tender Fee 500
EMD 76000
Exemption Available
Document List
8837PS.pdf
8837SOC.xls
8e07824b-5630-4a45-927a-4c59d2e083b5.html
BOQ_879520.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
pdf

8837PS.pdf

xls

8837SOC.xls

html

8e07824b-5630-4a45-927a-4c59d2e083b5.html

xls

BOQ_879520.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders