Tender For Repair And Maintenance Of Various Type Of Earthing, Lighting Arrestor, Garden Light Gate Lights/Post Of Lights And Others Connected Items At Af Station Mullanpur Under Age (I) Highground Chandigarh
Tender Value
5 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
15 days left
EMD
10000
Bank guarantee accepted
Document Fee
300
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Various Type Of Earthing, Lighting Arrestor, Garden Light Gate Lights/Post Of Lights And Others Connected Items At Af Station Mullanpur Under Age (I) Highground Chandigarh
BOQ
| Sl. No. | Item Description |
| 1 | Supply and Fix in repair LED 10 watts IP-65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution garden light fitting with robust design and efficient light distribution including light fitting fixing and making PCC block foundation and connecting the fittinngs on PCC foundation block including taking out old complete all as specified and directed, complete all as specified and as directed.Make -Crompton LBLSN-10-CDL or its equivalent from list of makesNote : (i) PCC Block Size should be 300 x 300 x 450 mm.(ii) The unit rate quoted shall deemed to include the cost of PCC Block and all fittings of bollard light. |
| 2 | Supply and fixing in repairs new generation IP-65 protected LED min 40 Watts Gate Light, energy saving environmental friendly, long lige aesthetically designed with good indirect symmetrical light distribution, die cast aluminium landscape lumination with high power COBLED as light source, complete all as specified and as directed.Make -Crompton LPTO-40-CDL-M or its equivalent from list of makes. |
| 3 | S&F in repairs LED 10 Watts, Bamboo type LED bollard with IP 65 protection, including nuts, bolts and other accessories, light fitting fixing and making PCC block foundation and connecting the fittinngs on PCC foundation block including taking out old complete all as specified and directed. Make -Crompton LBLA1-10-CDL or its equivalent from list of makes.Note : (i) PCC Block Size should be 300 x 300 x 450 mm.(ii) The unit rate quoted shall deemed to include the cost of PCC Block and all fittings of bollard light. |
| 4 | Supply and Fix in replacement KIOSK box weather proof made out of PVC/HDPE fire retardent,non fusing,shock and rust proof, pole mounted, hinged door size minimum 300X260X120mm comprising of conection point for phase and neutral and MCB Terminal Channels for fixing of MCB, including clamps with necessary MS nuts bolts and washer complete all as specified and as directed. Make : Sintex or its equivalent from list of makes. |
| 5 | Supply and fix in replacement TPN MCB 63 Amp, 415 Volt, bracking capacity 10 KA, 'B' curve, 50Hz, colmplete all as specified and as directed. |
| 6 | S&F in repair in replacement of MCB SPN, 230 Volts, AC 50 Hz 40 to 63 Apms, 10 KA, 'B' curve complete all as specified and directed. |
| 7 | Material and labour, painting two coats of synthetic enamel paint to LT panel any description (external surface only) including preparation of old painted surface, complete all as specified and directed. |
| 8 | Supply, laying, jointing and commissioning in replacment LT underground cables XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade 2 core, cross sectional area 10 sq. mm with all fighting lugs, nuts and bolt etc. all as specified and as directed. |
| 9 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil) for laying of cables or GI pipe and getting out including levelling of bottom suface to required level complete all as specified and directed.Note : Excavation work of treanches should be done by labour. |
| 10 | Returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. |
| 11 | Removing excavated material from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. |
| 12 | Material and Labour for demolition of path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) .complete all as specified and as directed. |
| 13 | Material and Labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate with smooth finished without using extra cement above ground level complete all as specified and directed. |
| 14 | Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part - I of size 63mm outer dia and 50 mm inner dia complete all as specified and as directed. |
| 15 | Supply and Fix in repair Aluminium strip 25 x 3.15 mm with saddles and fixing screws on porecelain insulator/ spacer fixed at every 1 mtr length on roof/wall and joining the same with New earth test point complete all as specified and directed.Note :- All connections to the earth strip should be done by exothermic welding. |
| 16 | Supply and Fix in repair GI strip 32 x 6 mm with saddles and fixing screws on porecelain insulator/ spacer fixed at every 1 mtr length on roof/wall and joining the same with New earth test point complete all as specified and directed.Note :- All connections to the earth strip should be done by exothermic welding. |
| 17 | Supply and Fix in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required GI or steel wire 4.00mm dia, complete all as specified and directed. |
| 18 | M&L in repairs for air termination, single pointed aluminium rod, 12mm dia and 300mm long including necessary fixing arrangement using clamp, nuts and bolts after taking down old unserviceable termination rod complete all as specified and directed. |
| 19 | Supply and Fix in repairs for air termination, single pointed copper rod, 12mm dia and 300mm long including necessary fixing arrangement using clamp, nuts and bolts complete all as specified and directed. |
| 20 | Supply and fix in repair GI pipe of size 50 mm dia light grade as earthing strip protection laid on trench/floor, fixed on pole/wall complete all as specified and directed. |
| 21 | Supply and Fix in repair test point terminal block made of gun metal or phosphorous bronze of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws, complete all as specified and directed.Note : (i) Enclosure shall be made up FRP box of suitable size. Make-Sintex/Hensel or equivalent from list of makes. |
| 22 | Material and Labour for dismantling the existing broken earth pits and supply and fixing prefabricated/precast factory made PCC earth pit chamber of min size 450x450x300 mm alongwith precast chamber cover with lifting handle complete all as specified and directed. |
| 23 | Material and Labour for maintenance of conventional earth pit, pouring salt water solution of (salt and water ratio 1:3) 5Kg : 15Ltr to earthing, tightening of earth electrode, removing grass around the earth pit, repair/replacement of funnels, removal of soil from the watering pipe complete all as specified and as directed.Note: (i) Location for repairing of earth pit chamber and earth pit covers shall be as per the direction of Engineer-in-Charge. (ii) All the maint works/replacement of parts are independent to each other except salt water solution. |
| 24 | Material and Labour for painting earth pit chamber and earth pit by two coat of syenthetic enamail paint after cleaning earth pit properly with iron wire brush and indicating board as per colour code as specified and directed. |
| 25 | Material and Labour for earthing complete with Copper earth plate electrode of size 600mm x600mm x3.15mm, buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth plate not less than 1.5 Mtrs deep below normal ground level, connected to copper earth strip of size 20x3 mm dia by means of brazing and connected to earthing test point / distribution board/equipments or any other indicated situation by means of brazing all as shown in electrical plate No.3 of SSR Part I (2009) and testing on completion including necessary excavation and earth work in any type of soil, returning filling, removing of soil. GI medium grade pipe 32 mm dia 1.5 mtr long with funnel and wire mesh as watering pipe, and GI medium grade pipe 32 mm dia as earth lead protection pipe. Earth pit chamber made of PCC 1:2:4 type B1 using 20mm graded stone aggregate including 40mm thick chamber cover made of 1:2:4 type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 100 c/c on both ways precast chamber cover with lifting handle 16mm dia round bars including chorcoal and common salt in alternate layer of 15cm thick covering all faces of earth electrode plate, including taking down old, complete all as specified and directed.Note :- (i) The rates quoted for the complete earthing shall deemed to include the cost of copper strip 20 x 3 mm and GI medium grade protection pipe upto 7.5 Mtrs.(ii) Copper earth strip and GI medium grade protection pipe beyond 7.5 Mtrs length shall be measured and paid separately. |
| 26 | Material and Labour for replacement of old earthing and providing new earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron earth strip 32x6mm (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm bore, and watering pipe 20mm bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and as directed.Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include GI strip/wire and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.(iv) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt. |
| 27 | Note: The total amount shall subject to adjustment of credit of Rs 23650.00 for old Materials as per Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender