Housing Urban and Rular Development Government Departments Closing in 0 days TDR #57064272

Tender For Electrical Works For Construction Of Bunker For Installation Of High Dose Rate Brachtherapy System At Radiation Oncology Govt. Smhs Hospital Srinagar

Issued by Government Departments · Srinagar, Jammu and Kashmir
Tender Value
4.09 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
0 days left
EMD
8193
Bank guarantee accepted
Document Fee
300
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Works For Construction Of Bunker For Installation Of High Dose Rate Brachtherapy System At Radiation Oncology Govt. Smhs Hospital Srinagar

BOQ

Name of Work:- Electrical works for Construction of Bunker for installation of High dose rate Brachtherapy system at Radiation Oncology Govt. SMHS Hospital Srinagar
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable etc. as required as per IS Standard. (Acti-bacterial/anti-fungal)(Havells / Polycab / KEI)
2Group C
3Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required as per IS standard
4Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (Acti-bacterial/anti-fungal)(Legrand / L&K / ABB / Schneider)
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).(Legrand / L&K / ABB / Schneider)
6Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. as per IS standard(Acti-bacterial/anti-fungal)(Legrand / L&K / ABB / Schneider)
7Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(Acti-bacterial/anti-fungal)(Legrand / L&K / ABB / Schneider)
83 pin 5/6 A socket outlet
95/6 A switch
106 pin 15/16 A socket outlet
1115/16 A switch
12Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (partially laid Conduit in slab) as per IS Standard. (Acti-bacterial/anti-fungal)(Havells / Polycab / KEI)
132 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
142 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
152 X 4 sq. mm + 1 X 4 sq. mm earth wire
162 X 6 sq. mm + 1 X 6 sq. mm earth wire
172 X 10 sq. mm + 1 X 6 sq. mm earth wire
18Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
19Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
20Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
21Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
228 way (4 + 24), Double door
23Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Legrand / L&K / ABB / Schneider)
24Single pole
25Single pole & Neutral
26Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2732A (DP)
2840A (DP)
2963A (TPN)
30Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Havells / Crompton / Bajaj)
31Supply, Installation, Testing and Commissioning of heavy duty 450mm dia sweep PVC body, 900±10% RPM Exhaust fan with guard and mounting arrangement.Commercial series(Havells / Crompton / Bajaj)
32LED Panel light 2x2 ft. (System lumen efficacy ≥120 Lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, complete in all respects i/c connections with 1.5 sq. mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)(Phillips / LK / Wipro)
3336 Watt
34LED Down lighter (SMD Type) (System lumen efficacy ≥120 lm/Watt ), Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body including trim.(Phillips / LK / Wipro)
3522 watt
36Supply and fixing DP, SPN Residual Current Circuit Breaker 40 A(Legrand / L&K / ABB / Schneider)
37Earthling with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with chemical and salt as required. The job includes providing and fixing 25 mm × 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
38Supply, Installation, Testing, Commissioning of 4MP IP Fixed bullet Camera (STQC Certified Only)
39Supply, installation, Testing, Commissioning 4 Port Layer 2 Network POE Switch
40Supply, Installation, Testing and commissioning of 4 Channel, NVR
41Supply, Installation, Testing, Commissioning of fully loaded 2U Rack
42HDMI Cable
43Supply, Installation, Testing and commissioning of 2 TB HDD for NVR
44Supply, installation, Testing Commissioning of Cat 6A Cable 23 AWG Solid Copper Conductor.
45Wireless Mouse
46Supply, Installation, Testing, Commissioning of 32 inch FHD TV Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57064272
AUTHORITY Government Departments
TENDER VALUE 4.09 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Electrical Works For Construction Of Bunker For Installation Of High Dose Rate Brachtherapy System At Radiation Oncology Govt. Smhs Hospital Srinagar
Basic Detail
Tender No eNIT No. HDE 32 of 2026_27 dated 17_08_2026
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 18 Aug 2026
Submission Date 25 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 4.09 Lakhs
Tender Fee 300
EMD 8193
Exemption Not Available
Document List
1ea2ed87-457d-483f-8dc0-35b9aa941ff1.html
BOQ_1072069.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

1ea2ed87-457d-483f-8dc0-35b9aa941ff1.html

xls

BOQ_1072069.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail