Tender For Special Repair To Lt Panel And Other Connected Items At E/M Installation Under Jorhat Mil Stn.
Tender Value
43.59 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
10 days left
EMD
88000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jorhat → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Lt Panel And Other Connected Items At E/M Installation Under Jorhat Mil Stn.
BOQ
| Sl. No. | Item Description |
| 1 | NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. |
| 2 | Supply, install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved Confirming to IP55 LT panel board outdoor type of size 0.80m x 0.80m x 0.40m, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size MS angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -400 Amps, cable entry (incomming and outgoing ) form bottom with cable gland Incomming :-(a) MCCB 4 Pole, 250 Amp, 36 KA - 01 Nos (b) Digital voltmeter 0-500 volts with suitable PT and selector switch - 01 No (c) Digital Amp meter 0-500 Amp with selector switch & suitable CT - 01 No (d) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 setOutgoing - (a) MCCB 160 A (Fixed Type),415 Volts 4 pole, 25 KA - 01 Nos (b) MCCB 100 A (Fixed Type),415 Volts 4 pole, 18 KA - 01 No (c) MCCB 63 A (Fixed Type),415 Volts 4 pole, 18 KA - 01 No |
| 3 | Supply , install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 2.0 mm thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size and necessary foundation work and comprising following :-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -600 Amps, cable entry (incomming and outgoing ) form bottom with cable gland Incomming :-(a) MCCB 4 Pole, 400 Amp, 36 KA - 01 Nos (b) Alum bus bar 500 Amp TPN - 01 Set (c) Digital voltmeter 0-500 volts with suitable PT and selector switch - 01 No (d) Digital Amp meter 0-500 Amp with selector switch & suitable CT - 01 No (e) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 setOutgoing - (a) MCCB 4 Pole, 320 Amp, 36 KA, - 01 Nos (b) MCCB 4 Pole, 250 Amp, 36 KA, - 01 Nos ( c) MCCB 4 Pole, 160 Amp, 25 KA, - 01 Nos (d) MCCB 4 Pole, 100 Amp, 25 KA, - 01 Nos ( e) MCCB 4 Pole, 63 Amp, 16KA, - 01 Nos |
| 4 | Supply, install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved Confirming to IP55 LT panel board outdoor type of size 0.80m x 0.80m x 0.40m, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size MS angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -500 Amps, cable entry incomming form bottom with cable gland Incomming :(a) MCCB 4 Pole, 320 Amp, 36 KA - 01 Nos (c) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 set |
| 5 | Supply , install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved Confirming to IP55 LT panel board outdoor type of size 0.80m x 0.80m x 0.40m, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size MS angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -400 Amps, cable entry incomming form bottom with cable gland Incomming :-(a) MCCB 4 Pole, 250 Amp, 36 KA - 01 Nos (b) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 set |
| 6 | Supply , install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved Confirming to IP55 LT panel board outdoor type of size 0.80m x 0.80m x 0.40m, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size MS angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -300 Amps, cable entry incomming form bottom with cable gland Incomming :-(a) MCCB 4 Pole, 160 Amp, 36 KA - 01 Nos (c) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 set |
| 7 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 400 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 8 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 250Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 9 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 160 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed. |
| 10 | Materials and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip 32x6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 11 | Labour only for boring of hole under roads with mechanical arrangement upto 50 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed. |
| 12 | Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up old unserviceable pipe complete all as specified and as directed. |
| 13 | Supply and laying GI tubing 80mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up old unserviceable pipe complete all as specified and as directed. |
| 14 | Supply and fixing Galvanised Iron Strip 32 × 6 mm with saddles and fixing screws for roof/earth running and down conductors above ground including taking down unserviceable strip complete all as specified and as directed. |
| 15 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 16 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 25 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 17 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 35 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 18 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 50 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 19 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 70 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 20 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 95 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 21 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 120 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 22 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 150 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 23 | Material and labour for LT 1.1 KV (Earthed) grade heat shrinkable end termination jointing kit straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size up to 150 sqmm sqmm complete all as specified and as directed. |
| 24 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for taking out and laying at cable etc soft/loose soil complete all as specified and as directed. |
| 25 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm on soft/loose soil complete all as specified and as directed. |
| 26 | Removing excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 27 | Material and labour for sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 cm in depth after laying the Cable) and consolidated (punned) upto 18 cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for. |
| 28 | Material and labour for Brick with subclass 'B' bricks in cable protection, laying with built in each other complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender