Defence Statutory Bodies & Commissions/Committees Closing in 22 days TDR #57063352

Tender For Provision Of Ht Connection At Iblur And Provn Of Electric Connection For 240 Kw Fast Charger Of Ev Buses Of Mt Coy, Asc Centre Under Ge(Central)Bangalore.

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
99.30 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
22 days left
EMD
1.73 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Ht Connection At Iblur And Provn Of Electric Connection For 240 Kw Fast Charger Of Ev Buses Of Mt Coy, Asc Centre Under Ge(Central)Bangalore.

BOQ

Name of Work:- PROVISION OF HT CONNECTION AT IBLUR AND PROVN OF ELECTRIC CONNECTION FOR 240 KW FAST CHARGER OF EV BUSES OF MT COY, ASC CENTRE UNDER GE(CENTRAL)BANGALORE.
Sl. No. Item Description
1M & L for Measuring Equipements HT-ETV (electronic trivector) meter 0.2 accuracy class with ABT feature and DLMS (device language message specification) protocol with TOD with RS 232 Port and 11 KV HT measuring cubical of different CT Ratio both side cable entry type, 3 CT and 3 PT with transparent cover TTB (test terminal block) with 30x8mm Copper Bus bar for 3Phase 4 wire metering without load break switch HT metering box, fabricated out of 3.15mm MS Sheet duly epoxy powder coated as per revised specification all as per Dwg No. BESOM/GM/QS&S/--Dtd 24.01.2018 and as per BESCOM recommndation including necessary PCC foundation etc., complete all as Specified & as directed
2Supply, install, testing & commissioning of outdoor type, welded stainless steel tank with IP-67 protection for SF-6 Tank and IP 54 protection for outdoor enclosure, both Side extensible type compact RMUs (VCB, SF6 Type) with Aluminium busbar4 way, one incomer Two breaker one outgoing (2OD+2VL) 350 MVA, 650 Amp, 21KA (VCB SF6 enclosed) as per IEC-62271, Aluminium Bus Bar consisting SF6 insulated motorized VCB of 11KV, 630Amp with overload and earth fault protection, capacitive voltage indication, Manometer, cable boots for VCB and castle key interlocked including necessary PCC foundation work with MS channel and MS angle frame as per manufacturer recommendation along with bottom cable entry and front cable termination suitable upto single run 3core 400sqmm HT cable with following specifications complete all as specified and as directed :- (i) A01 as incoming VCB & Outgoing VCB with 2 Nos OD braker three position isolator /earthing switch, bus bars, interlocking earth bars and stored spring energy mechanism.(ii) Stored energy mechanism for manual operation - 01 No.(iii) Set of 03 No’s Ring core protection CTs of suitable ratio as per feeder load, 1.0 VA, Class 0.1- 01 set in breaker. (Transformer rating 30.8MVA) Capacitive voltage indication fixed type VPIS 9- 15KV - 01 No in breaker
3(iv) Control voltage motor 24 DC-01 Nos each Breaker(v) Self powered OC+EF Protection relay type as per manufacturer recommendation with rechargeable - 01 No in each breaker(vi) Impluse withstand voltage: To earth and between phases: 75KV Insulation level: -Power frequency 1 min:28 Kv(vii) Master trip relay-01Nos each breaker(viii) Space heater (230VAC)- 01 Nos each breaker.(ix) One No Potential Transformer (PT) three phase, dry type (resin cast) fixed type 11 KV/110 VOLTS, 25 VA burden, accuracy class 1.0(x) Multi function meter for each breaker.(xi) Under/over Voltage Relay each breaker.(xii) Enclosure : CRCA sheet powder coated with Siemens grey shade IS 632 Front Cover: 3.15mm thick CRCA sheet powder coated with Siemens grey shade RAL 7035 Cable Cover: 3.15mm thick CRCA sheet powder coated with Siemens grey shade RAL 7035(xiii) Cable bushings interface C (400 bolted) , 630A(xiv) Bushings outside cone interface C for connection of external busbars 2x12V DC battery + charger scheme R-Y-B phase indication. Additional equipment delivered separately or mounted in respective panel. Set of coupling bus bars along with suitable coupling kit - 01No, Operating Handle - 01 No as per BESCOM recommndation Complete.
4Supply, install, testing & commissioning of outdoor type, welded stainless steel tank with IP-67 protection for SF-6 Tank and IP 54 protection for outdoor enclosure,both Side extensible type Compact RMUs (VCB, SF6Type) with Aluminium Busbar 3 way one incomer One breaker one outgoing (2OD+1VL) 350 MVA, 650 Amp, 21KA (VCB SF6 enclosed) as per IEC-62271, Aluminium Bus Bar consisting SF6 insulated Motorized VCB of 11KV, 630Amp with overload and earth fault protection, capacitive voltage indication, Manometer, cable boots for VCB and castle key interlocked including necessary PCC foundation work with MS channel and MS angle as per manufacturer recommend along with bottom cable entry and front cable termination suitable upto single run 3core 400sqmm HT cable with following specifications complete all as specified and as directed. (i) A01 as incoming VCB with 2 Nos OD braker three position isolator /earthing switch, bus bars, interlocking earth bars and stored spring energy mechanism. (ii) Stored energy mechanism for manual operation - 01 No.(iii) Set of 03 No’s Ring core protection CTs of suitable ratio as per feeder load, 1.0 VA, Class 0.1- 01 set in breaker. (Transformer rating 30.8MVA) Capacitive voltage indication fixed type VPIS 9- 15KV - 01 No in breaker
5(iv) Control voltage motor 24 DC-01 Nos each Breaker(v) Self powered OC+EF Protection relay type as per manufacturer recommended with rechargeable - 01 No in each breaker(xi) Impluse withstand voltage: To earth and between phases: 75KV Insulation level: -Power frequency 1 min:28 Kv(vi) Master trip relay-01Nos each breaker(vii) Space heater (230VAC)- 01 Nos each breaker.(viii) One No Potential Transformer (PT) three phase, dry type (resin cast) fixed type 11 KV/110 VOLTS, 25 VA burden, accuracy class 1.0(ix) Multi function meter for each breaker.(x) Under/over Voltage Relay each breaker.(xi) Impluse withstand voltage: To earth and between phases: 75KV Insulation level: -Power frequency 1 min:28 Kv(xii) Enclosure: 3.15mm thick CRCA sheet powder coated with Siemens grey shade IS 632Front Cover: 3.15mm thick CRCA sheet powder coated with Siemens grey shade RAL 7035Cable Cover: 3.15mm thick CRCA sheet powder coated with Siemens grey shade RAL 7035(xiii) Cable bushings interface C (400 bolted) , 630A(xiv) Bushings outside cone interface C for connection of external busbars 2x12V DC battery + charger scheme R-Y-B phase indication. Additional equipment delivered separately or mounted in respective panel. Set of coupling bus bars along with suitable coupling kit - 01No, Operating Handle - 01 No as per BESCOM recommndation Complete.
6S&F of GPRS Modem with All accessories as per BESCOM recommndation Complete all as specified & directed.
7Supply, & installation, testing and commissioning out door type, floor mounted step down transformer, 11KV/ 433 Volts ( At no load) AC 3 phase, 50 Hz, energy efficient level - 3, Amendment No.04, 2021,confirming to IS 1180- 2014, BEE Approved, capacity 160 KVA , oil immersed, naturally cooled, oil natural- air -natural (ONAN), Class A insulation with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group Dyn- 11 with natural brought out on secondary side (LV) and having tappings at +/- 2.5% to +/- 7.5% , 7positions, on HV side to be changed by means of hand operated off load tap changer gear. The maximum temprature rise should not exceed 35 degree C in oil and 40 degree C in HV /LV windings when measured by resistance method after countinuous full load run on an ambient temp of 50 degree C and shall also comprise of the following all as specified & directed :- (a) 01 cable box chamber on HV side( primary) consisting of 03 Nos porcelain / epoxy bushing with copper rods complete with nuts and washers, with 01 No cable gland suitable for existing cable. (b) 01 box on LV side( secondary) consisting of 04 Nos epoxy bushing with copper rods complete with nuts and washers with cable glands.
8(c) Oil conservator tank with filter type drain plug and oil level gauge.(d) Dehydrating breather with first fill of silica gel.(e) Explosive vent, thermometer pocket on tank cover, oil level guage, oil drain filter valve, lifting hooks, oil filling hole with cap / plug with connection plate complete. Air release valve plug at four Nos plate soil cast steel detachable rollers. (f) 01 No 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree C with metal guard having maximum perimeter temperatre reading indicator with resetting device.(g) 02 Nos earthing terminals on tank cover to facilitate fixing of 50 x 6 mm GI earth strip for earthing of body. Rating plate and terminal marking plate.(j) The transformer shall be erected complete with standard fittings on PCC platform for transformer of size 2X2X2 mtrs including necessary M S channel, angles with nut bolt washer with necessary painting etc complete all as specified. and directed.
9(h) Extra bushing for natural, in the LT cable box for providing independent set of earthing for natural.(j) First fill of new transformer oil, IS- 335 marked filtered and tested up to 60 KV die electric strength at 2.5 mm air gap between testing electrodes.(k) Providing adequate size and Numbers of channels, embedded in floor, for movement of transformers.(m) Provn for transformer fixing on trolley arrangement system (openable).
10Supply and spread stone metal graded aggregate of size 40 mm at transformer yard complete all as directed.
11S&F of Mild Steel steel angle iron work as in struts and posts in fencing including cutting tops to shape as directed ,drilling holes notching for wire any flat iron fillets (for securing wire mesh and any wire type) including drilling,bolting or riverting and embedding in angle irion and screwing etc similar work confirming to Fe-290 Gde E-165 complete all as specified & directed.
12S&F of MS steel screw bolts (machine made) with hexgonal or square heads at ends and screwed end to be fitted with washers and one hexgonal or sqaure or square nuts exc 5cm but n.exc 10cm long and diameter of neck is 12mm complete all as specified as directed.
13Supply only Mild steel Chain link Galvanised fencing 50mmx 50mm Mesh all as specified and directed
14Fixing only chain link fencing including line wires any mesh,size and type straining bolts including provision of binding wire complete all as specified as directed.
15M & L for Cement concrete (1:3:6) type C2 using 40 mm graded stone aggrregate aggregate as in copings including chamfers,weatherings,throating & necessary shuttering etc. complete all as specified as directed.
16M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation and mass concrete all as specified & directed.
17M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size 25x20cm in HT sub station complete all as specified & directed.
18Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and getting out in soft / loose soil all as specified and directed.
19Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm thick in soil, complete all as specified and as directed.
20Removing excvated soil not exc. 50m and deposited where directed at a level not exc. 1.50m above the starting point complete all as specified and as directed.
21M&L for Sand cushioning dry in trenches for protection of UG cables, below & above the cable laid in trenche and consolidated (punned) all as per Para 19.75 of SSR Part-I complete all as specified and as directed. (Note : Punned thickness of sand willbe measured & paid)
22Supply & Laying Sub-Class B old size Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion for UG cable protection complete all as specified and directed. Please Enable Macros to View BoQ information
23Supply & Laying Sub-Class B old size Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion for UG cable protection complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57063352
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 99.30 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Ht Connection At Iblur And Provn Of Electric Connection For 240 Kw Fast Charger Of Ev Buses Of Mt Coy, Asc Centre Under Ge(Central)Bangalore.
Basic Detail
Tender No 86552/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 18 Aug 2026
Submission Date 15 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 99.30 Lakhs
Tender Fee 1000
EMD 1.73 Lakhs
Exemption Not Available
Document List
51629e4f-6e6c-4140-859c-8bbc8cc30838.html
BOQ_879490.xls
tender86552.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
html

51629e4f-6e6c-4140-859c-8bbc8cc30838.html

xls

BOQ_879490.xls

pdf

tender86552.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders