Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #57063345

Tender For Repair/Maint Of Internal Wiring With Their Fittings/Fixtures Of Otm, Residentail Area And Repair/Replacement Of Street Light, Flood Light, Post Top Light, Dg Set, Connected Panels And Repair/Maint Of External Lt Supply Dist, Lt Panels And

Issued by Statutory Bodies & Commissions/Committees · Kamrup Metro, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Sep 2026
14 days left
EMD
99780
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Internal Wiring With Their Fittings/Fixtures Of Otm, Residentail Area And Repair/Replacement Of Street Light, Flood Light, Post Top Light, Dg Set, Connected Panels And Repair/Maint Of External Lt Supply Dist, Lt Panels And Allied Services At Cda/Lao Complex Under Ge Guwahati

BOQ

Name of Work:- REPAIR/MAINT OF INTERNAL WIRING WITH THEIR FITTINGS/FIXTURES OF OTM, RESIDENTAIL AREA AND REPAIR/REPLACEMENT OF STREET LIGHT, FLOOD LIGHT, POST TOP LIGHT, DG SET, CONNECTED PANELS AND REPAIR/MAINT OF EXTERNAL LT SUPPLY DIST, LT PANELS AND ALLIED SERVICES AT CDA/LAO COMPLEX UNDER GE GUWAHATI
Sl. No. Item Description
1Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and as directed.
2Taking down carefully UNSV MCB DBs, SP/TP by unscrewing from main switch boards/cut out boxes and removing matrials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good to disturbed surfaces of wall etc as per existing finishes complete all as specified and directed
3M&L for concealed point wiring using approved colour coding (Red, Black and green for single phase circuits) complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade, IS-694 marked with valid CML No. and including drawn through non metallic rigid PVC Concealed conduit medium grade minimum of adequate size ISI-694 marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) and conduit accessories concealed in wall/roof/floor etc and chisselling on wall complete and including PVC insulated multi-starnded copper conductor 1.5Sqmm nominal cross sectional area single core cable as earth conduity conductor to common earth and connecting to earth dolly complete all as specified and as directed at site for the following srl items :-
4One light/ Fan point controlled by one no one way switch complete all as specified and as directed.
5One 3 pin socket outlet, 5/6 Amps on independent board
6One 3 pin socket outlet point, 5/6 Amps on same board
7One modular bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5Sqmm size complete all as specified and as directed.
8M&L for point wiring complete with 4.0 Sqmm (nominal area) single core PVC insulated and unsheathed FRLS multistranded copper conductor cable (maintaining colour code) 1100 volts grade drawn through and including PVC casing caping of adequate size but not less than 20mm in width and 1.2mm thick with all fittings and accossories ISI marked including modular surface box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc and complete with all fittings and accessories fixed to wall/ceiling one 3/5 pin 15 Amp socket outlet and including provisining of 4.0 sqmm (nominal area) PVC insulated flame retardant unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor cable green in colour to common earth and connected to earth dolly for fixed to wall/ ceiling complete all as specified and as directed.
9Supply and fixing Modular switch one way 5/6 Amp, 1 module, 240 Volts complete all as specified and as directed.
10Supply and fixing Modular socket outlet 3 pin plug, 6 Amps, universal socket outlet, 2 module 240 Volts complete all as specified and as directed.
11Supply and fixing Modular switch single pole, one way modular type, 16 Amp, 1 module, 240 Volts complete all as specified and as directed.
12Supply and fixing Modular socket 6/16A, 2 in 1, 2 module, 240 volts complete all as specified and as directed.
13Supply and fixing Modular Bell push 5/6 Amp, 1 module, 240 Volts complete all as specified and as directed
14Supply and fixing bell, Ding dong, AC, 230 volt complete all as specified and as directed.
15Supply and fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
16Supply and fixing ceiling rose 3 point/ PVC/ Polycarbonate, isolated body 250/230 volts ISI marked complete all as specified and as directed.
17Supply and fixing modular electronic fan regulator, stepped type, 220 volt, 100 watt complete all as specified and as directed.
18Supply and fixing as in repair LED tube light fitting, 1x20/22 watt, 220-240 volt, AC, invertor type with inbuilt rechargeable lithium battery back up for emergency operation, decorative box type complete with LED tube, electronic driver, holder, diffuser and automatic changeover during power failure with minimum of 03-04 hours battery backup suitable for wall/ceiling mounting including connecting up with three core flexiblwe copper conductor of suitable size from ceiling rose complete all as specified and as directed.
19Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
20Supply and fixing as in repair 10W LED Bulkhead light, pressure die cast housing LED bulkhead with IP65 Protection and IK09 Impact resistance suitable for surface/wall mounted,complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
21Supply and fixing as in repair LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
22Supply and fixing as in repair round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
23Supply and fixing as in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
24Supply and fixing as in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
25Supply and fixing as in repair LED street/bldg security light fitting 35 Watt, 230V, AC, outdoor type, with high pressure die-cast aluminium housing and heat resistant complete with driver, corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed.
26M&L for 32mm bore light grade GI pipe fixed as bracket, on wall any type, not less than 1.5 m long and bent to shape as required complete with sutiable clamp made out of 25x4mm Flat iron duly fixed 12mm dia nuts, bolts, washers etc fixed to pole complete with two coats of aluminium paint over a coat of red oxide complete all as specified and as directed
27M&L for sub main wiring using two run (Red for phase and black for neutral) single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLS) ISI marked drawing in and including PVC rigid non metalic PVC concealed conduit of adequate size but not less than 25mm dia and accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed including taking down old submain wiring of any type, complete all as specified and as directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of PVC Conduit with accessories shall be measured as one length.
28M&L for sub main wiring using two run (Red for phase and black for neutral) single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLS) ISI marked drawing in and including PVC rigid non metalic PVC concealed conduit of adequate size but not less than 25mm dia and accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed including taking down old submain wiring of any type, complete all as specified and as directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of PVC Conduit with accessories shall be measured as one length.
29Supply and fixing as in repair Factory made load line distribution board in sheet steel enclosure double door with 200 Amps rated bus bar, TPN, 4 ways, 240 Volts suitable for housing MCCBs as incomer (except MCCB) including cutting chases for sinking of boxes complete all as specified and as directed.
30Supply and fixing as in repair Factory made distribution board in sheet steel enclosure vertical single door with 200 Amps rated bus bar, TPN, 4 ways, 240 Volts suitable for housing MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed.
31Supply and fixing as in repair Factory made distribution board in sheet steel enclosure double door glazed with 200 Amps rated bus bar, SPN, 8 ways, 230 Volts suitable for housing MCBs complete all as specified and as directed.
32Supply and fixing as in repair Factory made distribution board in sheet steel enclosure double door glazed with 200 Amps rated bus bar, SPN, 4 ways, 230 Volts suitable for housing MCBs complete all as specified and as directed.
33Supply and fixing as in repair MCCB, 125 Amp, four pole, 415 volts, breaking capacity 36KA fixed thermal and fixed magnetic setting complete all as specified and as directed.
34Supply and fixing MCB, TPN, 415 volts, C Curve, 100 Amps, 10 KA, 4P complete all as specified and as directed.
35Supply and fixing MCB, TPN, 415 volts, C Curve, 63 Amps, 10 KA, 4P complete all as specified and as directed.
36Supply and fixing MCB, SPN, 240 volts, C Curve, 32 Amps, 10 KA complete all as specified and as directed.
37Supply and fixing MCB, SP, 240 volts, C Curve, 20-32 Amps, 10 KA complete all as specified and as directed.
38S&F in repair power Unit with 20 A SP MCB & plug 240 volts complete for Acs &geyser complete all as specified and as directed.
39S&F in repair motor starter, 25A, 240 volts complete for Acs &geyser complete all as specified and as directed.
40M&L in repair for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SI Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc including taking down old earthing complete all as specified and as directed. Note:- Rate quoted by tenderers shall be deemed to include for following provisions-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 m. [ii].PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore medium grade & copper lugs, charcoal & salt as reqd .[v]. GI protection pipe of size 15 mm bore light grade 7.5m.
41Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal headed screws complete all as specified and directed.
42Taking down old unserviceable flood light/street light/ Post top lantern fittings etc any type including brackets, cable and connections complete all as specified and directed.
43S&F Post top lantern LED type 45 Watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp and connecting up with and including three core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed.
44Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and connecting up with and including three core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed
45S&F LED street light fitting 90 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and connecting up with and including three core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed
46S&F LED flood light 120 watt 230 volts AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and connecting up with and including three core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed.
47S&F LED flood light 210 watt 230 volts AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and connecting up with and including three core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed.
48S&F House service bracket complete with 1.5m long G.I. pipe 40mm dia light. grade, two nos 90/45 degree bends. M.S.hook and stay or guy and fixed with 25mm x 4mm MS flat with necessary nuts, bolts, washers etc, as required and painting with two coats of syntheic enamel paint over a coat of primer anf fixed to pole complete all as specified & as directed.
49S&F 50mm bore GI pipe bracket (Light Grade) of length 1.5 mtrs bent to shape and fixed with 25mm x 4mm MS flat with necessary nuts, bolts, washers etc, as required and painting with two coats of syntheic enamel paint over a coat of primer anf fixed to pole complete all as specified & as directed.
50S&F in repair 1.5 Sq.mm size three core PVC insulated copper conductor cable of for connection from junction box to street light fittings run through pole complete all as specified and as directed.
51M&L thermpolastic cable junction box IP 66 with metric knocknouts for cable entry and 4 way terminal of size 155mm x 210mm x 92mm having 04 Nos copper bus bar fixed on procelian insulators fixed in position with aluminum clamps of size 25mm x 3mm and necssary nuts and bolts complete all as specified and directed. Please Enable Macros to View BoQ information
52M&L thermpolastic cable junction box IP 66 with metric knocknouts for cable entry and 4 way terminal of size 155mm x 210mm x 92mm having 04 Nos copper bus bar fixed on procelian insulators fixed in position with aluminum clamps of size 25mm x 3mm and necssary nuts and bolts complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57063345
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 07-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Internal Wiring With Their Fittings/Fixtures Of Otm, Residentail Area And Repair/Replacement Of Street Light, Flood Light, Post Top Light, Dg Set, Connected Panels And Repair/Maint Of External Lt Supply Dist, Lt Panels And Allied Services At Cda/Lao Complex Under Ge Guwahati
Basic Detail
Tender No 8682/E8
Bidding Type Tender
Location
City Kamrup Metro
State Assam
Key Dates
Publish Date 18 Aug 2026
Submission Date 07 Sep 2026
Open Date 09 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 99780
Exemption Available
Document List
8682Tender.pdf
BOQ_879225.xls
fe6460e0-35eb-4cf6-958a-557666287e93.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
pdf

8682Tender.pdf

xls

BOQ_879225.xls

html

fe6460e0-35eb-4cf6-958a-557666287e93.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders