Tender For Execution Of Electric Works (Non-Ac) On The 8Th Floor Block A West Wing Of Directorate Of Ordnance (C&S) Kolkata And Pronv Of Roof Treatement At S-39 And Provn Of Sound Proof Window, Tiling And Paneling In Stair Case And Certain Plumbing W
Tender Overview
Project Description
Tender for Execution Of Electric Works (Non-Ac) On The 8Th Floor Block A West Wing Of Directorate Of Ordnance (C&S) Kolkata And Pronv Of Roof Treatement At S-39 And Provn Of Sound Proof Window, Tiling And Paneling In Stair Case And Certain Plumbing Work At S-1 And Provision Of 12 X Window Ac (1.5 Ton) For 2 X Dinning Hall, 02 X Sainik Institute, 03 X Officers, 01 X Duty Officer Room, 02 X Jco Mess / Club, 01 X Ops Room And 01 X Mi Room Of 1211 Med Regt At Raspunja Mil Stn Under Ge (C) Kolkata
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE ( C ) KOLKATA Name of Work: EXECUTION OF ELECTRIC WORKS (NON-AC) ON THE 8TH FLOOR BLOCK A WEST WING OF DIRECTORATE OF ORDNANCE (C&S) KOLKATA AND PRONV OF ROOF TREATEMENT AT S-39 AND PROVN OF SOUND PROOF WINDOW, TILING AND PANELING IN STAIR CASE AND CERTAIN PLUMBING WORK AT S-1 AND PROVISION OF 12 X WINDOW AC (1.5 TON) FOR 2 X DINNING HALL, 02 X SAINIK INSTITUTE, 03 X OFFICERS, 01 X DUTY OFFICER ROOM, 02 X JCO MESS / CLUB, 01 X OPS ROOM AND 01 X MI ROOM OF 1211 MED REGT AT RASPUNJA MIL STN UNDER GE (C) KOLKATA Contract No: GE (C )/KOL/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # ItemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Taking down Chowkat or Frame with shutters (without taking off Shutter from the Frame) exc. 1.50 Sqm but not exc. 4.00 Sqm each , complete all as specified and as directed. |
| 3 | Taking down Chowkat or Frame with shutters (without taking off Shutter from the Frame) nexc. 1.50 Sqm each , complete all as specified and as directed. |
| 4 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed. |
| 5 | M&L Double charged Virified tiles light/dark shade 10mm thick (square/ rectangular) polished, area of each tile exceeding 0.42 sqm but not exec 1.00 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in cement mortar (1:6) all as specified and as directed |
| 6 | M&L premium quality 5mm thick WPC acoustic wall panelling for indoor / outdoor 100% nontoxic non feraldeyers, water proof, termite proof anti UV using necessary clip / fixing arranement including beading complete all as specified and directed |
| 7 | Taking up or down Steel Water Tubing 25/32mm dia (bore) including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly including cleaning for re-fixing or removal to store including necessary scaffolding and safety measure upto any height of building, complete all as specified and as directed. |
| 8 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with and including 10mm thick toughened glass and fly proof S.S wire mesh, (0.36mm nominal dia of wire and avg width of aperture 1.4mm), Two nos. glazed & one no. wire mesh panels, upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimensionof uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified anddirected by Engineer-in-Charge. Note: For uPVC frame and sash extruded profiles plus/minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made |
| 9 | S&F in repair Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples complete all as specified and as directed. |
| 10 | S&F 10mm thick toughned glass as in hinged doors, partitions automatic door and similar work including cutting to shape, drilling holes required complete all as specified and directed |
| 11 | S&F 10mm thick toughned glass as in door / window shutter / frame complete all as specified and directed |
| 12 | M&L Glazed Ceramic Coloured Tile 450x300x7mm thick on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layer in cement mortar (1:4) complete all as specified and as directed. |
| 13 | S&F 25mm bore dia of CPVC water tubes SDR 11 with all fittings SDR 11 and fixed complete to walls and ceilings or laid in floors complete all as specified and directed |
| 14 | S&F 32mm outer dia of CPVC water tubes SDR 11 with all fittings SDR 11 and fixed complete to walls and ceilings or laid in floors complete all as specified and directed |
| 15 | S&F 25mm bore brass MTA for CPVC pipe complete all as specified and directed. |
| 16 | S&F 32mm bore brass MTA for CPVC pipe complete all as specified and directed. |
| 17 | S&F 25mm bore brass elbow complete all as specified and directed. |
| 18 | S&F 32mm bore brass elbow complete all as specified and directed. |
| 19 | S&F 25mm bore brass Tee complete all as specified and directed. |
| 20 | S&F 32mm bore brass Tee complete all as specified and directed. |
| 21 | S&F in repair vitreous china EWC cascade type white including cistern, seat and cover, inlet accessories complete all as specified and as directed by Engr-in-ChargeMake - Parryware, Cat Part No -C844A Qube or technocommerically equivalent in model from make approved |
| 22 | M&L Cement Concrete type B0 (1:2:4) (12.5mm graded aggregate) 25mm thick, in Flooring, finishing concrete surfaces even and smooth complete all as specified and as directed. |
| 23 | M&L 15mm thick screed bed in CM (1:4) surfaces finished the surfaces even and fair without using extra cement for padding complete all as specified and directed |
| 24 | Stripping of old tarfelt including layer of plaster or morter of any type treatement carefully from roof surfaces (without damage of roof) and roughening of surface of old concrete roofing by picking sweeping cleaning and washing down with water to remove dust as directed and specified. |
| 25 | M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer's instructions, complete all as specified and as directed :-(a) Preparing and cleaning of fully dry surface as per IS:3067-1966.(b) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.40 Litre per Sqm.(c) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.00 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(d) Applying one coat of Aluminium Paint @ 0.11 Litre per Sqm over APP based Polymeric Membrane. |
| 26 | Supply and fix Voltage stabilizer of capacity 3KVA for automatic operation single phase, naturally air cooled copper wounded, indoor type and designed for input variation between 170V to 250V with output voltage stabilized at 230 V with accuracy of ± 2.5%, LED display wall mounted complete all as specified and directed |
| 27 | S&F A C starter unit of 6 module box flush in wall with cover plate and frame consisting of one 16 Amp capacity starter, one 240 V 16 Amps 10 KA SPN MCB, one 16 Amps socket and one 25 Amps plug top prewire complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F window type air conditioner 1.5TR electric driven (single phase) with nominal cooling capacity 4750-5800 watt, (1.5 ton), BEE 5 star rated inverted type ISEER value 5 to 5.5 with copper evaportator and condenser and corldess remote control including cutting of existing wall of required size to fix AC alongwith wooden frame, making good the wall by plastering in CM 1:3 and painting as per existing finish complete all as specified and directed |
| 29 | M&L for point wiring for 15amps point on independent board with PVC insulated unsheathed multistranded single core FRLSH copper conductor cable of size 4sqmm for phase and neutral drawn into and including PVC casing caping with all accessories including 4sqmm FRLSH PVC insulated unsheathed single core copper conductor as earth continuity conductor directely from MCB DB box complete all as specified and directed |
| 30 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 95 Sqmm 4 core in trench/duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. |
| 31 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 4 core in trench/duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. |
| 32 | S&F DWC pipe of inner dia 76mm and outer dia 90mm to be fixed on wall/floor/duct/trench complete all as specified and directed |
| 33 | Taking out unserviceable UG cable of any type and any size from trenches/wall/floor/duct etc and removing from the site of work complete all as specified and directed |
| 34 | S&F MCCB 4 pole 100A, 16KA, 415V Ics=100% lcu adjustable thermal and fixed magnetic type including MCCB box and making electrical connection complete all as specified and directed |
| 35 | Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc and making good distrubed surfaces of walls, floors, etc. including cleaning all and specified and directed. |
| 36 | M&L for point wiring for one light/bell/fan controlled by one no one way switch complete with 1100 volts grade FRLSH PVC insulated multistraded copper conductor cable confirming to IS-694 of size 1.5sqmm two runs single core for phase and neutral drawn through and including PVC concealed conduit of suitable size (minimum 20mm dia medium grade ISI marked) complete with one run of 1100 volt grade FRLSH PVC insulated multistraded copper conductor cable 1.5sqmm single core green colour for earth condinuity conductor and connecting to common earth dolly complete including making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing surrounding surface complete all as specified and directed Note :-Modular GI box, PVC box, cover plate alonwith frame will be measured and paid separately |
| 37 | All as per item No 35.00 here-in-before but for one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. |
| 38 | All as per item No. 35.00 here-in-before but for one 3 pin 5 amps switch socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge. |
| 39 | All as per item No.35.00 mentioned here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 3 Pin 16Amp, socket outlet point on independent board complete PVC insulated and unsheathed copper condutor earth continuity conductor to common earth and connecting to earh dolly as specified and directed by Engineer in charge |
| 40 | M&L fo Point wiring for 15AMP socket controlled by one way swtich with 2.5sqmm 1100 volts grade FRLSH single core cable for phases and neutral PVC insulated multistraded copper conductor 1100 volt grade including PVC casing caping of required size with all necessary fitting including 2.5sqmm FRLSH PVC insulated unsheathed multistranded copper conductor as earth lead and connected to common earth dolly complete all specified as directedNote :-(i) Modular GI box, PVC box, cover plate alongwith frame will be measured and paid separately |
| 41 | All as per item No 39.00 but on 5Amp socket outlet on same board complete all as specified and directed |
| 42 | S&F Switch piano, Modular 1M flush type, SP, one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed. |
| 43 | S&F Modular Socket outlet 3/5 pin, 6 Amps, 240 volt flush type complete all as specified and as directed. |
| 44 | S&F modular socket outlet 5A, 3 Pin, 2 Module complete all as specified and directed |
| 45 | S&F modular switch, one way, 16Amp, 1 module complete all as specified and directed |
| 46 | S&F Modular Bell push switch 6A 1 Module complete all as specified and directed |
| 47 | S&F call bell, ding dong AC 230 Volts, single pole complete all as specified and directed |
| 48 | S&F modular ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed. |
| 49 | S&F ceiling fan regulator electronic Step Modular type, solid state, 240 volts, complete all as specified and as directed |
| 50 | S&F LED luminaire 600mm x 600mm, 35/36 Watt, 220V AC recessed/surface type in warm/natural/cool day white with high efficency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed |
| 51 | Taking down sub main wiring alongwith damaged casing caping/PVC conduit pipe from the wall roof or in floor and making good disturbed surfaces complete all as directed |
| 52 | S&F Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 10.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 10.0 Sqmm as earth lead drawn through and including rigid non metalic PVC concealed conduit of size 15 mm dia including all fittings including complete all as specified and as directed.Note:- Two runs of 10 Sqmm conductor as main wire and one run of 10Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. cost of cutting chases make good and finishes are deemed to be included in quoted rate |
| 53 | S&F Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4 Sqmm as earth lead drawn through and including rigid non metalic PVC concealed conduit of size 25 mm dia including all fittings complete all as specified and as directed.Note:- Two runs of 4 Sqmm conductor as main wire and one run of 4Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. cost of cutting chases make good and finishes are deemed to be included in quoted rate |
| 54 | Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed. |
| 55 | S&F factory made powder coated distribution board SPN, 6 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc including taking down old unserviceable DB with MCB complete all as specified and directed.Note :- (i) MCBs shall be measured and paid seperately.(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 56 | S&F factory made powder coated distribution board SPN, 4 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc including taking down old unserviceable DB with MCB complete all as specified and directed.Note :- (i) MCBs shall be measured and paid seperately.(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 57 | S&F MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve breaking capacity 10 kA complete all as specified and as directed. |
| 58 | S&F MCB 40 to 63 Amps, DP 240 Volts ,C- Curve breaking capacity 10 KA including necessary connection complete all as specified and as directed. |
| 59 | S&F factory made powder coated distribution board TPN, 4 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 200 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc including taking down old unserviceable DB with MCB complete all as specified and directed.Note :- (i) MCBs shall be measured and paid seperately.(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 60 | S&F MCB TPN, 63 Amps 415 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. |
| 61 | M&L Cutting chase, pinning in making good to facing where required and pointing in CM 1:3 to end or edges of landing steps, cills, sunshades, shelves, lintels etc. and cutting chase for conceled conduit wiring etc and making good (cutting not exc 10Cm girth) complete all as directed |
| 62 | S&F smart single phase meter single phase 2 wire tamper proof static meter of class 1.0, 50Hz, AC 10 to 60 amps of make confirming to BIS-16444 standard with plug able GPFS / 4G communication with LCD based display including IP-54 complaint polycarbonate box for indoor/outdoor mounting with optical port provision on meter box complete all as specified and directed |
| 63 | S&F plastic surface box modular type of 12M for fixing of modular switches/sockets to the wooden desk using screws complete all as specified and directed |
| 64 | S&F GI modular sunken box of 1/2module flush on wall for housing modular switches/sockets/regulator etc including making good using CM 1:3 as per existing finish complete all as specified and directed |
| 65 | All as item No 63.00 here-in-before but for 3 modules |
| 66 | All as item No 63.00 here-in-before but for 8 modules |
| 67 | S &F modular cover plate with frame for fixing of modular switches/socket complete for 1/2 modules complete all as specified and directed |
| 68 | All as item No 66.00 here-in-before but for 3 modules |
| 69 | All as item No 66.00 here-in-before but for 8 modules |
| 70 | All as item No 66.00 here-in-before but for 12 modules Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender