Tender For Repair Maintenance To Internal Electrification, Light Fittings, Earthing And Lighting Arresters And Connected Items At Air Force Station Highground Under Age (I) Highground
Tender Value
15 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
12 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Maintenance To Internal Electrification, Light Fittings, Earthing And Lighting Arresters And Connected Items At Air Force Station Highground Under Age (I) Highground
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully with battens/ PVC surface/ concealed conduit unserviceable copper/ aluminium point wiring (light, fan, socket) complete including fittings such as switches, ceiling roses, pendants, socket etc. and removing unserviceable material from site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed. |
| 2 | M&L for point wiring PVC insulated sheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting switches, sockets,fan regulators etc including all necessary wall cutting chasis and making good disturbed surfaces in cement mortar 1:3 and as per existing colour of white wash / paint / OBD / cement base paint complete all as specified and as directed. |
| 3 | All as per item No. 2.00 here-in-before but point wiring for one 5Amps socket outlet point on independent board controlled by one single pole, one way switch with cable /wire 1.5smm size complete all as specified and directed. |
| 4 | All as per item No. 2.00 here-in-before but point wiring for one 5Amps socket outlet point on same board controlled by one single pole, one way switch complete all as specified and directed. |
| 5 | All as per item No. 2.00 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push with cable 1.5smm complete all as specified and directed. |
| 6 | All as per item No. 2.00 here-in-before but point wiring using 2.5 sqmm as main wire & 2.5 Sqmm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed. |
| 7 | All as per item No. 2.00 here-in-before but point wiring using 4 sqmm as main wire & 4 Sq mm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed. |
| 8 | Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in the existing conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, using the existing pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover/ modular sheet cover for mounting of conventional/ modular switch/ sockets/ fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified. |
| 9 | All as per item No. 8.00 here-in-before but point wiring for one 5 Amps socket outlet point on independent board controlled by one single pole, one way switch with cable /wire 1.5 sqmm size complete all as specified and directed. |
| 10 | All as per item No. 8.00 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push with cable 1.5smm complete all as specified and directed. |
| 11 | All as per item No. 8.00 here-in-before but point wiring using 2.5 sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed. |
| 12 | All as per item No. 8.00 here-in-before but point wiring using 4sqmm as main wire & 4 Sqmm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed. |
| 13 | Material and Labour for point wiring surface type with 3 x 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH copper conductor cable (phase, neutral & earth wire), earth wire shall be connected to common earth and earth duly with suitable copper lugs drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, 1.60 mm thick GI metal flush box with plastic laminated sheet cover or surface mounting plastic/ PVC boxes suitable for modular/ conventional switches/ sockets/ fan regulators with cover plates (modular/ conventional type as required), blanking plates, brass screws, cup washers, gypsum screws and connected items including all cutting/ chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and as directed for the followings. |
| 14 | One light point controlled by one switch. |
| 15 | One ceiling/exhaust/wall fan point controlled by one switch. |
| 16 | One socket outlet 5 amps point on the same board with other switches. |
| 17 | One socket outlet 5 Amps point controlled by one switch on independent board. |
| 18 | All as per serial item No 13.00 above but with 3 x 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board complete all as specified and directed. |
| 19 | All description as per srl item No 13.00 but point wiring with size of cable 4 sqmm for industrial socket outlet 3 pin 16 / 20 Amps point complete all as specified and directed. |
| 20 | Supply and Fix in repairs modular Switch, single module, 6 Amp, one way, ISI marked, fire retardant, specification as per existing make and model complete all as specified and as directed. |
| 21 | All as per serial item no 20.00 above but 16A complete all as specified and directed. |
| 22 | Supply and Fix modular socket outlet 2-in-1, 3 pin, 6/16 Amp, two module, shuttered socket, specification as per existing make and model complete all as specified and as directed. |
| 23 | All as per serial item no 22.00 above but socket, 6A, 3 pin combined 2 module complete all as specified and as directed. |
| 24 | Supply and Fix modular step type fan regulator high speed, dust free glossy finish pure white color, 120 watt, 150-270V, 50Hz two module socket type complete all as specified and directed. |
| 25 | All as per serial item no 24.00 above but one module complete all as specified and as directed. |
| 26 | Supply and Fix modular Bell push 6 Amp 230 volt, one module complete all as specified and directed. |
| 27 | Supply and Fix modular switch, 6 Amp 230 volts single pole, 2 way, one module complete all as specified and directed. |
| 28 | Supply and Fix modular white cover plate and with frame 12 module suitable for fixing of modular switches/sockets complete all as specified and directed. |
| 29 | All as per serial item no 28 above but 8 module complete all as specified and as directed. |
| 30 | All as per serial item no 28 above but 6 module complete all as specified and as directed. |
| 31 | All as per serial item no 28 above but 3/4 module complete all as specified and as directed. |
| 32 | All as per serial item no 28 above but 1/2 module complete all as specified and as directed. |
| 33 | Supply and Fix in repairs modular Switch socket outlet combination with PVC box, multipurpose 3 pin, 16 amp and one pin, 6 amp controlled by one switch complete all as specified and as directed. |
| 34 | Supply and Fix in repairs modular switch socket combination with suitable pvc box 5A, 3 pin, 3 module complete all as specified and as directed. |
| 35 | Supply and fix in repair switch piano, flush type, single pole, one way, 5 Amp, 230 volts complete all as specified and directed. |
| 36 | All as per serial item no 35.00 above but 6A, 2 way complete all as specified and as directed. |
| 37 | Supply and fix in repair switch Bell push, flush type, single pole, one way, 230 volts complete all as specified and directed. |
| 38 | Supply and fix in repair switch piano, flush type, single pole, one way, 15 Amp 230 volts complete all as specified and directed. |
| 39 | Supply and fix in repair Socket outlet multipurpose 3 pin 5 Amp & 15 Amp, flush type, complete all as specified and directed. |
| 40 | Supply and fix in repair Fan regulator electronic,100W, rotory step type, one module, suitable for 1200mm /1400mm sweep ceiling fan, fixed in repairs, with and including provision of PVC flexible cable of size 1sqmm copper conductor as required, complete all as specified and directed. |
| 41 | Supply and Fix ceiling rose, 6 Amps, 230 volts, AC with three terminals and PVC/ Polycarbonate insulated body of size as per site requirement complete all as specified and directed. |
| 42 | Supply and Fix in repairs switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and as directed. |
| 43 | All as per item no. 42 here in before but Switch socket combination 2 in 1, 6A flush type complete all as specified and as directed. |
| 44 | Supply and Fix in repairs precut/ customized bakelite/hylum sheet, 3mm thickness of size 5x5 inches (1 to 3 module) with extra length machine screws as per site requirement complete all as specified and as directed. |
| 45 | All as per serial item no 44 above but suitable for 4 to 6 module complete all as specified and as directed. |
| 46 | All as per serial item no 44 above but suitable for 8 to 12 module complete all as specified and as directed. |
| 47 | Supply and fixing modular multipurpose socket combined with 25 amp MCB SP, 1.20 mm thick GI metal flush box or surface mounting plastic/ PVC box suitable for modular sockets with cover plates (modular type), blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing including taking down old/ unsv sheet metal enclosure or modular socket complete all as specified and directed. |
| 48 | Supply and Fix PVC Non metallic conduit of external dia 20 mm medium grade including of all tees, bends elbow, reducers bell mouth tube end and fixing accessories such as coupler, lock nuts, tie, saddles, pipe hooks etc but exclusive of junction boxes complete all as specified and directed. |
| 49 | All as per Srl item No 48 but 25 mm dia complete all as specified and as directed. |
| 50 | Supply and fix in repair Call bell, electric Ding - Dong type (Domestic pattern), 230 volt, single pole, complete all as specified and directed. |
| 51 | Supply and Fix in repair wall mounted LED batten 22 watt (LxWxH- 1144mm X 25mm X 35mm) with epoxy powder coated white extruded aluminium channel housing for efficient heat dissipation, lumen efficacy of 125lm/W, radiation free, mercury free, glare-free efficient light distribution, white coloured ABS end caps, electronic driver, 140-270 Volt, THD<10%, mounting into the wall/ ceiling by SS clips with all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 52 | All as per Srl item No 51 here-in-before but LED batten 10 watt (LxWxH- 581mm X 25mm X 35mm) complete all as specified and directed. |
| 53 | Supply and Fix in replacement LED Recess mounted 2x2 ft (595mm X 595mm and ht 70mm or as per site requirement) luminaire fitting LED 34/36 Watt CRCA powder coated with lumen efficacy of ≥140 lm/W, cct 3000 to 6500K (as per site requirement), radiation free, longlife, environment friendly, mercury free, symmetric/ uniform light distribution, operating voltage 140V-270V, 50/60 Hz, powered by an independent isolated, SELV output electronic LED driver, pf >0.9, THD<10%, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing as per requirement at site complete all as specified and directed. |
| 54 | All as per srl item no 53 but LED Surface mounted 1x1 ft (295mm X 295mm X 70mm) luminaire fitting LED 18 Watt as per site requirement complete all as specified and as directed. |
| 55 | Supply and Fix in repair LED Bulkhead luminaire 20 watt of polycarbonate housing and enclosed with acrylic diffuser, waterproof including all connections as per existing at site complete all as specified and as directed. |
| 56 | Supply and Fix in replacement of energy efficient LED round (dia as per site requirement) recess/surface mounted downlight fitting 18 Watt, 140V-270V, 3000 K to 6500 K couler temp, white powder coated, aluminium heat sink with efficacy of ≥140 lm/W, symmetrical light distribution, powered by an independent, isolated, SELV output electronic driver, snap fixed on the fixture, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire as per existing at site complete all as specified and as directed. |
| 57 | Supply and Fix in repair LED 10 watts IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution garden light fitting with robust design and efficient light distribution including light fitting fixing and making PCC block foundation and connecting the fittinngs on PCC foundation block including taking out old complete all as specified and directed. |
| 58 | Material and Labour for service cable 4 Sqmm 3 core 1100 volts grade heavy duty cable PVC insulated stranded copper conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular complete all as specified and directed. |
| 59 | All as per Srl item No 58 here-in-before but 2.5 sqmm 3 core complete all as specified and directed. |
| 60 | All as per Srl item No 58 here-in-before but 1.5 sqmm 3 core complete all as specified and directed. |
| 61 | All as per Srl item No 58 here-in-before but 0.75 sqmm 2 core complete all as specified and directed. |
| 62 | Supply and Fix in repair decorative type wall mounted antique brass fitting and glass, two lamp wall light, incandescent type LED bulb with base, cct 3000 to 6500K (as per site requirement), symmetric/ uniform light distribution, operating voltage 140V-270V, 50/60 Hz, pf >0.9, THD<10%, push button type controller, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing as per requirement at site complete all as specified and directed. |
| 63 | Supply and fix in repair indirect post top for garden & landscape lighting of min 25 watts with IP 65 protection, 140-270V, pole dia 50mm, efficacy > 100 lm/W, CRI 70, canopy spun aluminiuum powder coated in matt finish, diffuser - high performance optical grade PC inside and outside acrylic, internal wiring - 0.5 sq mm teflon coated mains terminal - 3 way 5 Amps for internal connection, surge arrestor - 4 KV inbuilt in driver and 10KV External inside housing, resistant to impact and corrosion, anti Glare and uniform distribution complete all as specified and directed. |
| 64 | Supply and fix in repair Sheet metal enclosure (DB) single phase & neutral, double door 4 way, 240 volt with 200 Amps rated bus bar & IP 54 protection, complete all as specified and directed. |
| 65 | All as per item No.64.00 here-in-before but DB 8 way complete all as specified and directed. |
| 66 | All as per item No.64.00 here-in-before but DB 12 way complete all as specified and directed. |
| 67 | Supply and fix in repair Sheet metal distribution board TPN/VTPN, with double door,4 way, 415 volt with 200 Amps rated bus bar neutral link, blanking plates and having provision of MCCB upto 200 amp, 4 Pole as incomer and MCBs SP/TP as outgoing as per IS, having IP-43 protection, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 68 | Supply and fix in repair Sheet metal distribution board TPN/VTPN, with double door,4 way, 415 volt with 200 Amps rated bus bar neutral link, blanking plates and having provision of MCCB upto 200 amp, 4 Pole as incomer and MCBs SP/TP as outgoing as per IS, having IP-43 protection, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender