Tender For Annual Repair And Maintenance Of Residential & Non Residentila Building(Ar&Mo) , Annual Repair & Maintenance Of Electric Installation (Armoei), Dharchula Under Ge (Mes) Pithoragarh
Tender Overview
Project Description
Tender for Annual Repair And Maintenance Of Residential & Non Residentila Building(Ar&Mo) , Annual Repair & Maintenance Of Electric Installation (Armoei), Dharchula Under Ge (Mes) Pithoragarh
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Aug-2026 | Amendment in BOQ | BOQ | 08-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | DESCRIPTION OF ITEMS |
| 2 | Demolition of cement concrete in ground floor, paving nexc 15cm thick(below or above GL) complete all as specified and directed |
| 3 | M & L for 75mm thick PCC 1:3:6, type C-1, as in Plinth protection etc finished even & smooth without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 meter and at change in direction complete all as specified & directed. |
| 4 | M & L for 100mm thick PCC 1:2:4, type B-1 finished even and smooth without using extra cement complete all as specified & directed. |
| 5 | M&L providing cement concrete type B0, 1:2:4 (12.5mm aggregate) in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed |
| 6 | M&L for PCC 1:5:10 type E2 (using 40mm graded aggregate) as in subbases/ sub floors/pavings etc. complete all as specified |
| 7 | Demolition of brick work, stone/boulder masonry built in cement mortar complete all specified and directed |
| 8 | M&L for brick work with sub class 'B' brick old size bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as spfd & directed. |
| 9 | M&L precast cement concrete block masonry with solid blocks of plain cement concrete 1:3:6 type C1 (using 20mm graded crushed stone aggregate) exc 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 10 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in C.M. 1:6, complete all as specified. |
| 11 | Taking down cement plaster on brick or stone walls, of any description including raking out joints, hacking for key, scrubbing down with water, etc complete all as spfd and directed. |
| 12 | M&L 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces including finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 13 | M&L 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surface including finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 14 | M&L for Preparing new plastered wall surfaces and applying two coat of oil emulsion distemper over a coat of wall putty 1mm thick over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 15 | M&L for preparing newly plastered surface of wall apply two coat of cement base paint over a coat of primer complete all as specified and directed |
| 16 | M&L three coats of white wash on wall surfaces including preparation of new plastered surfaces complete all as specified and directed |
| 17 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 18 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm and not exceeding 0.18 sqm, in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as spfd & directed |
| 19 | M&L for vitrified ceramic tiles/outdoor tiles 8-12mm thick (square or rectangular) polished area of each tile not exc.0 .36 sqm in floor etc and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade complete laid over and including screed bed or bedding layer of mortar CM (1:6) 15mm thick all as specified and directed |
| 20 | M&L for vitrified ceramic light shade tiles/outdoor tiles 8-12mm thick (square or rectangular) polished area of each tile not exc.0 .36 sqm in skirting etc and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade complete laid over and including bedding layer in CM (1:4) 10 mm thick all as specified and directed |
| 21 | M&L for coloured glazed ceramic tiles in vertical surface, 350x250x7mm to 450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick plaster in CM 1:4 complete all as spfd & directed. |
| 22 | M&L for Chequered coloured cement concrete tiles 30cm x 30 cm x 20-25 mm thick set, jointed and pointed in neat cement slurry with grey pigment cement and pigments in floor over and including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed |
| 23 | M&L Granite (of any type) tiles 20 mm thick machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 15mm thick screed bed in CM 1:6 etc complete all as specified and as directed |
| 24 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete in floors over and including 15mm thick screed in CM 1:6 etc complete all as spfd & directed |
| 25 | M&L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, in skirting over and including 10mm thick screed in CM 1:4 etc set complete all as spfd & directed |
| 26 | M & L for one coat of white wash on old decorated wall surfaces including preparation all as specified and directed |
| 27 | M & L One coat of Oil bound distemper on old decorated wall surfaces including preparation complete all as specified and directed |
| 28 | M&L for Preparing old surfaces, plastered or unplasterd old decorated wall surfaces and applying two coat of oil emulsion distemper over a coat of wall putty of 1mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 29 | M&L for Preparing old surfaces, plastered or unplasterd old decorated wall surfaces and Finishing walls with textured paint ofrequired shade (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior grade primer applied @ 2.20kg/10 sqm over a coat of wall putty of 1mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 30 | M &L for preparing old previously treated steel surface as in roof sheets or any other surface of any description not other wise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 31 | M &L for preparing old previously treated steel surface as in roof sheets or any other surface of any description not other wise described over 10 cm in width or girth and applying two coat of synthetic enamel paint complete all as specified and directed. |
| 32 | M &L for preparing old previously treated surface of wood and wood based surfaces of any description not other wise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 33 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less that 50gm/liter and UV resistance as per IS-15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 liter / 10 Sqm over and including priming coat of exterior primer applied @0.90 liter/10 Sqm over new surfaces over a coat of wall putty of 1mm thickness complete all as specified and directed. |
| 34 | Taking down chowkhats or frame nexc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 35 | Taking down chowkhats or frame exc 1.5 sqm but nexc 4.00 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 36 | Taking down shutter exc 1.0 sqm but n exc 2.00 sqm each complete all as specified and directed. |
| 37 | S&F for mild steel framed wk as in doors or gates of angle iron or other section complete drilled for fixing of steel sheeting or other covering doors, etc to be prepared for hanging or sliding with & incl either hooks & hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running rails and slides) & hanging, also fastening & fixing Fe-290, Gde-165 complete all as spfd & directed. |
| 38 | S&F 0.63 mm th Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as spfd & directed. |
| 39 | S&F 35 mm th Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 40 | M&L for 2nd class hardwood, 35 mm thick glazed and skeleton shutter, open rebated and prepared to receive glass, gauge, etc. divided into squares, with plain, chamfered or rounded , mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass etc; size of members of shutter as specified in SSR Part I, Section 8 clause 8.24(a); supplied and fitted to chowkhat complete all as specified and directed |
| 41 | S&F for powder coated anodised aluminium frame for doors, windows ventilator with one or more rebates including joining cleat for fixing etc , screws, hinges, brackets, dash fasteners/rawl plugs etc. complete all as specified and directed.complete all as specified and directed. |
| 42 | S&F powder coated aluminium door shutters, aluminium section weighing min. 0.55 Kg/m including necessary jointing cleats glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed |
| 43 | S&F powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing min. 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified complete all as specified and directed. |
| 44 | S&F 10 mm thick Toughned glass as in hinged doors, partitions, automatic doors and similar work including cutting to shape, drilling holes,necessary fittings/etching required. |
| 45 | M&L for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 46 | S&F Door closer hydraulically regulated, designation No. 2,aluminium die cast body universal type complete all as specified and directed. |
| 47 | S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in doors 140mm long all as specified and as directed. |
| 48 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/springs. |
| 49 | S&F 4.80 mm thick sheet glass ordinary quality and glazing with oil putty/rubber packing in square exc .50 sqm in each panels complete all as specified and directed. |
| 50 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and directed. |
| 51 | S&F Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 52 | S&F in repair Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 53 | S&F 100 mm mild steel but hinges medium weight, cold rolled complete all as specified and directed |
| 54 | S&F 150 mm aluminium handles, cast type anodised complete all as specified and directed. |
| 55 | S&F150 mm aluminium anodised barrel tower bolts extruded section complete all as specified and directed |
| 56 | S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 57 | S&F 100 mm Mortice lock,vertical type,size 100 mm complete all as specified and directed. |
| 58 | S&F 150 mm Mild Steel barrel tower bolts, stove enameled, black with bright bolts complete all as specified and directed |
| 59 | S&F 250mm long Mild steel sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed |
| 60 | S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed |
| 61 | Dismantling mild steel work of any description and in any position complete all as specified and as directed. |
| 62 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (beam, tee, angle channel or flat sections) (Fe-290 Gde E-165) including distance pieces, cleats etc. |
| 63 | Welded steel wire fabric supplied and fixed complete to wood or steel members weight not exceeding 4.00 kg per sqm complete all as specified and as directed. |
| 64 | S&F in repairs vitreous china wash basin, white flat back size 550X400mm, incl pedestal, 32mm size brass chromium plated waste fittings, waste pipe and brackets fixing in position complete all as specified and directed. |
| 65 | S&F in repairs vitreous china wash basin, rectangular or oval shaped with min . Size 550X400mm incl 32mm size brass chromium plated waste fittings, waste pipe fixing in slab/granite top incl necessary fixing arrangement complete all as specified and directed. |
| 66 | S&F in rep vitreous china squatting pan \\"Orissa pattern\\" size 580 mm x 440 mm white with integral foot rests, incl provn of lime concrete bedding complete all as spfd & directed. |
| 67 | S&F in repair Vitreous China Wash down water closet EWC with plastic seat cover complete all as specified and as directed . |
| 68 | S&F in repair Vitreous china premium/ 1st quality wash down water closet one piece EWC any color closed pattern incl all necessary accessories incl flushing cistern etc. complete in all respect all as specified. |
| 69 | S&F in repair sinks made of stainless steel 1 mm th kitchen or laboratory with plugs, washers & waste coupling, incl bedding in CM to dwarf wall or incl fixing cantilever brackets & connecting union to pipe over all size 495x420mm bowl size 410x330 mmx160 mm complete all as spfd & directed. |
| 70 | S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 71 | S&F for PVC low level flushing cistern 10ltr capacity, with cyphonic, action PVC float valve, brackets and 32mm bore PVC flush pipe etc as spd and fixed in repair all as specified and directed |
| 72 | S&F in repair Tubular towel rail brass chromium plated 20mm dia, D type, 60cm long between flanges complete all as specified and directed |
| 73 | S&F in repair brass CP Towel Ring fixed with and including Chromium plated brass screws and cleats complete all as specified and directed |
| 74 | S&F in repair 15mm bore Chromium plated Bib taps fancy type, cast copper alloy screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified |
| 75 | S&F in repair 15mm dia cast iron bib taps with forged brass stem & brass jumper valve, screwed for iron pipe and fixed all as specified and directed |
| 76 | S&F in repairs stop valve/angle valve, bore of dia 15mm of Chromium plated fancy type cast copper alloy screwed down for iron pipe and fixed etc complete all as specified and directed. |
| 77 | S&F in repairs Brass CP mixer fancy type for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 78 | S&F 15mm Pillar taps, cast copper alloy,fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repairs complete all as spfd & directed. |
| 79 | Supply only 15mm pillar taps, cast copper alloy, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as spfd & directed. |
| 80 | S&F in repairs Stainless steel soap dish, any type fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 81 | S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified |
| 82 | S&F in repairs plastic water closet seat, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging devise complete all as specified and directed. |
| 83 | M&L for 32mm in size Waste fittings, brass, chromium plated for stainless steel sinks, glazed ware basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed in repairs complete all as specified and directed |
| 84 | S&F PVC connections 15 mm size with PTMT nuts of length 600mm long fixed in repairs all as spfd and as directed. |
| 85 | S&F in repairs PVC waste pipe 32/40mm dia for wash basin/kitchen sink/urinals complete all as specified and as directed. |
| 86 | S&F in repair 25 mm bore Ball valves heavy duty, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed in repairs all as specified and directed. |
| 87 | S&F in repair 20 mm bore Ball valves heavy duty,high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed in repairs all as specified and directed. |
| 88 | S&F in repair 15 mm bore Ball valves heavy duty,high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed in repairs all as specified and directed. |
| 89 | S&F swivel shower of PTMT any colour for fixing with 15mm pipe along with shower arm 15mm size 195mm long with bend of 45 degree with flange of PTMT any colour, fixed in repairs complete all as spfd & directed |
| 90 | S&F in repairs shower concealed stop valve, bore of dia 15mm of Chromium plated fancy type cast copper alloy with long shank and capstan head for (Bath shower) screwed for iron pipe and fixed including making good existing surfaces complete all as specified and directed. |
| 91 | Supplying & laying in trenches/wall Polyethylene (PE-AL-PE) composite pressure pipes (Outside dia 16mm) including all Crimp type internal sealing Plastic-Metal Composite fittings (such as elbows, tees, reducers, etc.) complete fixed to wall or laid in floor etc including taking up or down 15 mm GI tubing complete all as spfd & directed |
| 92 | Supplying & laying in trenches/wall Polyethylene (PE-AL-PE) composite pressure pipes (Outside dia 20mm) including all Crimp type internal sealing Plastic-Metal Composite fittings (such as elbows, tees, reducers, etc.) complete fixed to wall or laid in floor etc including taking up or down 20 mm GI tubing complete all as spfd & directed |
| 93 | S&F 15 mm bore GI tubing with all fittings medium grade fixed to wall or laid in floor etc including taking up or down 15 mm GI tubing complete all as spfd & directed |
| 94 | S&F 20 mm bore GI tubing with all fittings medium grade fixed to wall or laid in floor etc including taking up or down 20 mm GI tubing complete all as spfd & directed |
| 95 | S&F in repairs Health Faucet (ABS Body) MS, Chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 96 | S & F in repair Harrison rails/curtain rods, mild steel, chromium plated with brackets, stops, rollers etc fancy type as approved complete all as specified and directed. |
| 97 | S&F 600mmx450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed in repairs complete all as spfd & directed. |
| 98 | Supply and fix 2000 Ltr rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top) hoisted & fixed in position including dismantling old water tank, complete all as specified and directed. |
| 99 | Supply and fix 1000 Ltr rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top) hoisted & fixed in position including dismantling old water tank, complete all as specified and directed. |
| 100 | Supply and fix 500 Ltr rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top) hoisted & fixed in position including dismantling old water tank complete all as specified and directed |
| 101 | Supply and fix 250 Ltr rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top) hoisted & fixed in position including dismantling old water tank complete all as specified and directed |
| 102 | S&F 25 mm bore Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed. |
| 103 | S&F 20 mm bore Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed. |
| 104 | S&F15 mm bore Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed. |
| 105 | S & F in repair mild steel lid/tank cover with hinges on one side & locking facility on another side/ or with thread secured with stainleess screws for water tank of capacity up to 1000ltrs complete all as specified and directed. |
| 106 | S&F in repair 15mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 107 | S&F in repair 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 108 | Supply and fix in repairs CP Wall Mixer with provision for Overhead Shower with 115mm Long Bend Pipe on Upper Side, Connecting Legs & Wall Flanges for 15mm dia pipe complete all as specified and directed. |
| 109 | Demolition and breaking up drain pipes 100 mm dia(Salt glazed ware, AC or reinforced concrete) set in cement mortar etc. complete all as specified and directed. |
| 110 | S&F 110 mm bore PVC(SWR) pipes single sockets in any length with rubber ring joints fixed to walls or laid in floors including fixing complete all as specified and directed. |
| 111 | S&F 110 mm bore PVC(SWR) bend any radius complete all as specified and directed. |
| 112 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets,fittings etc. as specified and directed. |
| 113 | S&F False Ceiling Horizontal level regular edge grid 600 x 600 mm form work using hot dip sections and fixing tiles vinyl laminated MPL gypsum panels size 595x595x6 to 8mm thick after lamination, suspended the grid with grid hangers to Roof Truss / RCC Slab all as spfd and directed. |
| 114 | S&F 5 to 8mm thick PVC hollow type wall panelling any color fixed to wall/ceiling with L or U shaped beading at ends fixed with screws complete all as specified and as directed. |
| 115 | M&L for 18/19mm thickness Medium density fibre board,one side laminated other side balancing, exterior grade, fixed in repair to framework with screws etc |
| 116 | S&F Cabinet Hinges(Set of 2),Soft Close, Full Overlay 4 Hole, Nickel Plated for 14-20mm Thick shutter for wardrobe, kitchen, Bathroom etccomplete all as specified and directed. |
| 117 | S&F catch magnet for cupboard shutter complete all as specified and directed. |
| 118 | M&L for 6mm thick Plywood, grade BWR, type BB, fixed in ceiling and walling with screws to timber frame work complete all as sfd and directed. |
| 119 | M&L II nd class hard wood plain fillets square or rectangular in section clean sawn but bull nosed chamfered or rounded on one edge or face sectional area exc 3 sqcm and nexc 6 sqcm secured in nails complete all as specified and directed |
| 120 | Dismantling of timber scantling 40 sqcm and over in section in any position for unframed works complete all as specified and directed |
| 121 | M&L for 2nd class hard wood as in scantling clean sawn framed & fixed as in ceiling and walling wks, complete all spfd & directed. |
| 122 | Dismantling of timber scantling 40 Sqcm under in section in any position, fixed with nails unframed work complete all as spfd & directed. |
| 123 | M&L for II nd class hard wood plain fillets square or rectangular in section clean sawn secured with nails sectional area exc 13 sqcm and n.exc 25 sqcm complete all as specified and directed |
| 124 | M&L for one coat of creosote oil to wooden surfaces new or old of any description including preparation of surfaces complete all as specified and directed. |
| 125 | Dismantling of plain or corrugated steel sheeting of any gauge/thickness in roof covering/wall cladding complete all as spfd and directed |
| 126 | S&F 0.63 mm th galvanised corrugated mild steel sheeting with two corrugation side lap fixed with 'L' type or 'J' type or cranked hook bolts fixed to roof covering/cladding to wall complete all as spfd & directed |
| 127 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 128 | S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 129 | M&L for two coat of synthetic enamel paint over a coat of pink primer to wooden surface of any description exc 10 cm girth or width including preparation of new wooden surfaces complete all as specified and directed |
| 130 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces of any description over 10 cm in width or girth incl preparation of new steel surfaces complete all as spfd and directed. |
| 131 | Demolition reinforced cement concrete in any description and in any position complete all as specified and directed. |
| 132 | M&L Slabs supported on walls, beams and columns in floors, roofs, landings,balconies,canopies, deck slabs and in shelves and the like using cement concrete type B-0 1:2:4 complete all as specified and directed |
| 133 | S&F Formwork to sides and soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surface of concrete complete all as specified and directed |
| 134 | M & L mild steel TMT bars 6 to 8mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed |
| 135 | Dismantling for Stone slabs and tiles/interlocking paver block of any description or thickness in floors, aprons etc laid dry or laid dry and pointed |
| 136 | M&L for Sand filling under floors or in foundations including watering and consolidation |
| 137 | M&L for Machine pressed precast concrete coloured interlocking paver block any shape, size & color (as approved) confirming to IS 15658-2006 of 80 mm thickness M-40 Grade fixed with grey cement and pigment |
| 138 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement incl removing of existing railing complete all as specified |
| 139 | S&F On site coventional LLDPE septic tank capacity of 3000 ltr designed to carry sewage and sludge water, incl excavation in any type of soil, 100mm PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and directed. |
| 140 | Construction of Soakage well incl excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20m dia and 3.0m effective depth all as per CEBZ TD/309 SHT-1/4 to 4/4 complete all as specified and directed. |
| 141 | M&L cleaning of existing septic tank and sewage well by closing the existing sewage system at last man hole. Removing man hole cover and dewatering the liquid waste by mechanical pumping. Removing the solid sludge by manually or by mechanical system up to the bottom of septic tanks and sewage well at any size incl depositing the solid sludge in the pit providing by digging in near by septic tank of appropriate size. Whole area to be covered with bleaching powder and covered by natural earth obtained from excavation after filling the solid sludge and making good completely hygienic and directed at site. Note: During the cleaning of soakage wells/septic tanks, alternate arrangement be made by contractor by temporary pumping arrangement for clearing continuous incoming sewage complete all as specified and directed Note :-(i) The cost of excavation of pit, bleaching powder and RFR to cover the sludge shall deemed to be inclusive in rate quoted by the contractor.(ii) All the tools and plants including mechanical pump and other allied arrangements for making sewage line functional will be made available by the contractor with out any extra cost to the Govt. (iii) Mode of Measurement- Qty of solid sludge shall only be measured for payment which shall be considered as 30% of volume of total liquid waste. |
| 142 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc and making good disturbed surfaces of walls, floors etc. complete all as specified. |
| 143 | M & L point wiring with 1.5 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable in PVC concealed /surface conduit 20mm or higher dia/ capping & casing , complete with all accessories /fitting in sunken terminal boxes modular /non modular ( terminal box should be of PVC heavy duty /GI ) with suitable size with 3 mm thick plastic laminated hard gloosy surface sheet top cover / modular sheet cover in case of modular sunken box .open recessed on all and brass screw and washer/ including modular top cover sheet , including unsheathed single core PVC insulated cable green in colour 1.5 Sqmm multistranded copper conductor as contineous earth wire and connecting to earth dolly including making good disturbed surfaces to same as previous existing complete all as specified for one light /fan /bell point controlled by one way switch of 5/6 Amps. |
| 144 | ditto as per item No 142 above but for one 3/5 pin socket outlet point on same board controlled by one way switch of 5 Amps |
| 145 | ditto as per item No 142 above but for one 3/5 pin socket outlet point on independent board controlled by one way switch of 5 Amps |
| 146 | M & L point wiring with 2.5 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable in PVC concealed /surface conduit 20mm or higher dia/in caping casig , complete with all accessories /fitting in sunken terminal boxes modular /non modular ( terminal box should be of heavy duty PVC/GI ) with suitable size with 3 mm thick plastic laminated hard gloosy surface sheet top cover /modular plate with frame open recessed on all and brass screw and washer/ including modular top cover sheet , including unsheathed single core PVC insulated cable green in colour 2.5 Sqmm multistranded copper conductor as contineous earth wire and connecting to earth dolly including making good disturbed surfaces to same as previous existing complete all as specified for one light /fan /bell point controlled by one way switch of 5/6 Amps. |
| 147 | S&F switch piano flush button single pole two way 5/6 Amps complete all as specified. |
| 148 | S&F switch piano flush button single pole two way 5/6 Amps complete all as specified. |
| 149 | S&F bell push flush button single pole one way 5Amps complete all as specified. |
| 150 | S&F switch piano flush button single pole one way 15Amps complete all as specified. |
| 151 | S&F socket out let 3 pin 5/6 Amps flush type complete all as specified. |
| 152 | S&F socket out let two in one 3 pin 5/6 Amps and 3 pin 15/16 Amps, flush type, non shutters, non interlocking complete all as specified. |
| 153 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed. |
| 154 | Supply & fixing in repairs modular switch one way 06 Amps,1 module, 240 volts complete all as specified & directed |
| 155 | Supply & fixing in repairs modular socket one way 6 Amps,2/3 pin combined ,2 module, 240 volts complete all as specified & directed |
| 156 | Supply & fixing inrepairs modular switch one way 16 Amps,1 module, 240 volts complete all as specified & directed. |
| 157 | Supply & fixing in repairs modular socket one way 6/16 Amps,2/3 pin combined ,2 module, 240 volts complete all as specified & directed. |
| 158 | Supply & fixing in repairs modular Bell Push 6A,(1 or 2 module as per site), 240 volts complete all as specified & directed. |
| 159 | Supply & fixing in repairs modular Two way switch 6A,(1 or 2 module as per site), 240 volts complete all as specified & directed. |
| 160 | S&F in repairs Modular steped type electronic fan regulator 2 module on the existing sheet etc. AC, 230 volts, duly ISI marked with and including connector complete all as specified & directed by Engineer-in-Charge. |
| 161 | S&F in repairs modular blanking /dummy Plates 1 M. |
| 162 | S&F in repairs modular white cover plate with frame including PVC Sunken box ,3 module for 6 / 16 Amps Switches , 240 volts complete all as specified & directed |
| 163 | S&F in repairs modular white cover plate with frame including PVC Sunken box ,4 module for 6 / 16 Amps Switches , 240 volts complete all as specified & directed . |
| 164 | S&F in repairs modular white cover plate with frame including PVC Sunken box ,6 module for 6 / 16 Amps Switches , 240 volts complete all as specified & directed. |
| 165 | S&F in repairs modular white cover plate with frame including PVC Sunken box ,8 module for 6 / 16 Amps Switches , 240 volts complete all as specified & directed . |
| 166 | S&F in repairs modular white cover plate with frame including PVC Sunken box ,12 module for 6 / 16 Amps Switches , 240 volts complete all as specified & directed . |
| 167 | S&F Ceiling rose, surface bakelite, AC, 60x30mm, 3 terminals complete all as specified and directed. |
| 168 | S&F in repairs lamp holder PVC/poly carbonated type with back plate suitable for pendants /angular /batten fittings complete all as specified and directed. |
| 169 | S&F in repairs Bell multi music type complete all as specified and directed. |
| 170 | S&F in repairs sheet metal enclosure for DB SPN 2 way 240 Volts, single door suitable for housing MCBs and isolators complete all as specified. |
| 171 | S&F in repairs sheet metal enclosure for DB SPN 4 way 240 Volts, Double door suitable for housing MCBs and isolators complete all as specified and directed |
| 172 | S&F in repairs sheet metal enclosure for DB SPN 6 way with 200 Amp rated bus bar 240 Volts, Double door suitable for housing MCBs and isolators complete all as specified and directed |
| 173 | S&F in repairs sheet metal enclosure for DB SPN 8 way with 200 Amp rated bus bar 240 Volts, Double door suitable for housing MCBs and isolators complete all as specified and directed |
| 174 | S&F in repairs sheet metal enclosure for DB SPN 12 way with 200 Amp rated bus bar 240 Volts,double door suitable for housing MCBs and isolators complete all as specified. |
| 175 | S&F in repairs sheet metal enclosure for DB TPN 4 way with 200 Amp rated bus bar 415 Volts,double door suitable for housing MCBs and isolators complete all as specified. |
| 176 | S&F in repairs Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt provison for fixing of 1 No MCCB of XT1160 frame suitable upto 160 Amp and 12 Nos MCB'S inside of DB, including 100 Amps ,25 KA 4 pole MCCB with metal door and flush to wall/fixed on wall surfce including grouting and cutting in existing wall and making good disturbed surface with two coats of white / colour washing / distempering etc to match the existing one complete all as directed by Engineer - in - Charge. |
| 177 | Supply & fixing in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including 20 Amps MCB, single pole, AC, 240 volts and flush to wall including all cuttings & chases etc on wall of fixed on surface of wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as directed . |
| 178 | S&F in repairs MCB SP 6-32 Amps, 240volts 10KA complete all as specified and directed. |
| 179 | S&F in repairs MCB SPN 32 to 63 Amps, 240volts 10KA complete all as specified and directed. |
| 180 | S&F in repairs MCB 4 pole 32 to 100 Amps, 240volts 10KA complete all as specified. |
| 181 | Material and labour for sub main wiring with 2x6 Sqmm nominal cross sectional area (two single core cable of 6 Sqmm for Phase and neutral + o1 single core cable of 6.0 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed /surface conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing and taking down the old unserviceable submain wiring of ant type complete all as specified & directed.( Note - One meter of conduit along with 2x6.0 Sqmm wire and one 6.0 sqmm earth wire shall be measured as one length). |
| 182 | S&F in repairs LED lights fitting integrated 1x 20W, 220V, AC ,Approx 4 feet size decorative box type with driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified. |
| 183 | S&F in repairs LED lights fitting integrated warm white 1x 20W, 220V, AC ,Approx 4 feet size decorative box type with driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified. |
| 184 | S&F in repairs LED lights fitting mirror type with high out put diffuser 2 feet,1x 10W, 220V, AC decorative box type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified. |
| 185 | S&F in repairs LED bulb 12 watts, 220V complete all as specified. |
| 186 | S&F in repairs LED luminaire 600 mm x 600 mm panel, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified. |
| 187 | S&F in repairs LED Bulk head 10 watt IP 65/66 all as specified and directed. |
| 188 | S&F in repairs Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LEDlamp B22 base. |
| 189 | S&F in repairs LED security light fitting 1x35 Watt luminaries with pressure die cast aluminium housing , with lenes embeded , IP-66/IP 65 Protection complete all asspecified and directed. |
| 190 | S&F in repairs GI bracket made out of 0.9-1.2 mtr GI pipe bent to shape light grade of 25to 40 mm dia, bracket mounting clamps nut bolts etc all as specified and directed. |
| 191 | S&F in repairs post Top Lantern 25 wattt ,IP 65 including all accessories ti fixing all as specified and directed. |
| 192 | Taking down and servicing ceiling fan from existing position, dismantling, overhauling and cleaning throughly, oiling /greasing and re- assemble after replacing split pins, check nuts, rubber seal etc and rehanging at same or new locations duly connected with new PVC three core flexible copper conductor cable of size 23/.0076, complete testing & specified.Note: Spare parts will be measured and paid separately under respective items as supply only as mentioned below. |
| 193 | Refixing of ceiling fan including fixing blades and making connection all as specified and directed. |
| 194 | M&L for taking out burnt copper winding from ceiling fan of 1200 mm size and rewinding with existing /same guage of super enammeled copper winding wire complete all as specified. |
| 195 | Supply only Ball bearing for Ceiling fan after and including taking down old ball bearing complete all as reqd at site, specified. |
| 196 | Supply only capacitor 2.5 mfd±5%, 440 Volt, AC, 50Hz after removing old defective condensor complete all as specified. |
| 197 | Taking down exhaust fan of any size from existing position, dismantling, overhauling and cleaning throughly, oiling/greasing and re- assemble after replacing unsv parts etc and rehanging the same duly connected with new PVC three core flexible copper conductor cable of size 23/.0076, complete testing & specified.Note: Spare parts will be measured and paid separately under respective items as supply only as mentioned below. |
| 198 | M&L for taking out burnt copper winding from exhaust fan of 300 mm and rewinding with existing /same guage of super enammeled copper wire complete all as specified. |
| 199 | M&L for taking out burnt copper winding from exhaust fan of 450 mm and rewinding with existing /same guage of super enammeled copper wire complete all as specified. |
| 200 | Supply and fix motor suitable for PVC exhaust 200 to 300 mm sweep exhaust fan Copper winding all as specidfied and directed |
| 201 | Supply and fixing motor of metal exhaust fan 300mm copper wounded all as specified and directed. |
| 202 | Supply and fixing motor of metal exhaust fan 450 mm ,1400 RPM copper wounded all as specified and directed. |
| 203 | Supply and fix exhaust fan PVC complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m all as specidfied and directed |
| 204 | Supply and fix exhaust fan PVC complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 m all as specidfied and directed |
| 205 | Material and labour for sub main wiring with 2x4 Sqmm nominal cross sectional area (two single core cable of 4 Sqmm for Phase and neutral + o1 single core cable of 4.0 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 4.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metal lic PVC concealed /surface conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing and taking down the old unserviceable submain wiring of ant type complete all as specified & directed.( Note - One meter of conduit along with 2x4.0 Sqmm wire and one 4.0 sqmm earth wire shall be measured as one length). |
| 206 | Taking down carefully storage water heater/Geyser of capacity 25/35/50 ltr, dismantling pipes assembly, cleaning thoroughly with descaling liquid compound complete to ensure free and constant flow of water through outlet, incl taking out unsv thermostate, haeting element or PVC connection pipe, reassembling the same at existing /new location including necessary fasteners to ensure proper safety as reqd at site, testing and commissioning after re-installation at site complete all as specified and directed.Note: Spare parts will be measured and paid separately under respective items as supply only as mentioned below. |
| 207 | Supply only heating element of 1.5/2.0 KW for geyser (as per sample ISI brand) including taking down old heating element complete all as specified and directed. |
| 208 | Supply only thermostate fitting fitment varying capacity for 25/35/50ltrs capacity geysers. |
| 209 | Supply only PVC connection pipe nylon threaded 15mm size with brass nuts copping in both end of length 600mm for geysers complete all as specified and directed. |
| 210 | Suppy and Fixing Chargeble LED Bulb 10 B 22 watt having backup minimum three hours all specified and directed. |
| 211 | Material and Labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metres below normal ground level, conneted to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, cheek nuts and washers of galvanised or iron protected by 15 mm bore GI pipe (medium grade) and connected to main switch board as directed including concrete pit in PCC (1:3:6) type C1 precast RCC (1:2:4) type B1 cover slab 40x40 Cm x 6Cm reinforced with 8 mm dia deformed bar @ 5 cm c/c with one handle for lifitting made out of 8 mm dia MS bar, funnle, wire mesh, 20 mm bore GI pipe (medium grade) for watering including charcoal and salt in alternative layers necessary excavation and earth work in any type of soil and testing complete all as shown on electrical plate No-3 of SSR part-I, 2009. |
| 212 | S&F in repairs plug 3 pin 15/16 Amp suitable at site complete all as specified and directed.make- Anchor/Cona/havells |
| 213 | S&F in repairs plug 3 pin 5/6 Amp suitable at site complete all as specified and directed.make- Anchor/Cona/havells |
| 214 | S&F Tape roll 6 meter long ,17 mm width for electrical work all as specified and directed. |
| 215 | S&F in repairs PVC board with two 5/6 Amp switch and two 5/6 amp sockets fixed in the board all as specified and directed. |
| 216 | S&F in repairs bed holder all as specified and directed. |
| 217 | S&F in repairs bed switch all as specified and directed. |
| 218 | supply and fixing ON load Load Changeover switch 125 Amp three phase with enclosure all as specified and directed. |
| 219 | S&F in repairs OFF Load Changeover switch 63 Amp three phase with enclosure all as specified and directed. |
| 220 | S&F in repairs OFF Load Changeover switch 32 Amp single phase with enclosure all as specified and directed. |
| 221 | Material and labour for sub main wiring with 2x1.5 Sqmm nominal cross sectional area (two single core cable of 1.5 Sqmm for Phase and neutral + o1 single core cable of 1.5.0 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 1.5.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metal lic PVC concealed /surface conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing and taking down the old unserviceable submain wiring of ant type complete all as specified & directed.( Note - One meter of conduit along with 2x4.0 Sqmm wire and one 4.0 sqmm earth wire shall be measured as one length). |
| 222 | Material and labour for sub main wiring with 2x2.5 Sqmm nominal cross sectional area (two single core cable of 2.5 Sqmm for Phase and neutral + o1 single core cable of 2.5.0 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 2.5.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metal lic PVC concealed /surface conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing and taking down the old unserviceable submain wiring of ant type complete all as specified & directed.( Note - One meter of conduit along with 2x4.0 Sqmm wire and one 4.0 sqmm earth wire shall be measured as one length). |
| 223 | S&F in repairs twin core flexible copper wire 1.5 sqmm all as specified and directed. |
| 224 | S&F in repairs twin core copper conductor cable of size 6 Sqmm , 1100 Volts grade, multi stranded, PVC insulated, unsheathed,all as specified And directed. |
| 225 | S&F in repairs flood light IP 66 100 watt all as specified and directed. |
| 226 | S&F in repairs ceiling fans complete with blades,copper winding, down rod accessories, 230 V, 1200 mm sweep. Min air delivery 225 CFM. Five star rated with brushless direct current motor (BLDC) , minimum 320 rpm all as specified and directed. Note: Old Unserviceable fan shall be deposited to MES Store Yard. |
| 227 | S&F in repairs exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep, 1400 RPM, 3250 CMH with, blades, and frame and louvers al as specified and directed. Note: Old Unserviceable fan shall be deposited to MES Store Yard |
| 228 | S&F LED bulb 9/10 watt (white/warm) white all as specified and directed. |
| 229 | S&F LED bulb 5 watt (white/warm white) all as specified and directed. |
| 230 | S&F LED bulb 15 watt warm white all as specified and directed. |
| 231 | Cleaning of rotational moulded polyethylene water storage tanks by removing of scale and dirt etc from tank and from mouths of circulating pipes etc of capacity exceeding 250 ltr but not exceeding 500 ltr complete all as specified.Note- Date of cleaning shall be mentioned on tank with synthetic enamel paint and cost of same is deemed to be included in the rates quoted by tenderer2. All tools and materials for cleaning the tank should be arranged by contractor. |
| 232 | Cleaning of rotational moulded polyethylene water storage tanks by removing of scale and dirt etc from tank and from mouths of circulating pipes etc of capacity exceeding 1000 ltr but not exceeding 2000 ltr complete all as specified. Note- Date of cleaning shall be mentioned on tank with synthetic enamel paint and cost of same is deemed to be included in the rates quoted by tenderer2. All tools and materials for cleaning the tank should be arranged by contractor. |
| 233 | Cleaning of water storage tanks of capacity 10000 ltrs by removing of scale, dumped sand, silt, debris and dirt any other foreign materials present in tanks/ walls and scrubbing out the floor etc. from mouths of circulating pipes etc and replacement of ball brass valve, high pressure, with polyethylene float and flynut complete, screwed for iron pipe or brass ferrule and fixed made of brass materials complete all as specified.Note-1.Date of cleaning shall be mentioned on tank with synthetic enamel paint and cost of same shall be deemed inclusive in quoted unit rate.2. All tools and materials for cleaning the tank should be arranged by contractor. |
| 234 | Cutting existing steel tubing 40 or 50 mm dia, screwing for alterations or additions for fittings such as unions, gate valves etc complete all as specified. |
| 235 | Cutting existing steel tubing 25 mm dia, screwing for alterations or additions for fittings such as unions, gate valves etc complete all as specified. |
| 236 | Taking up or down 50 mm dia bore GI tubing, and connections, including cleaning for re-fixing or removal to store complete all as specified. |
| 237 | Supply, fixing & laying of 50 mm dia bore GI tubing, medium grade with and including all fittings and fixture like socket, nipple, elbow, reducer etc complete laid in trenches or laid in floor complete all as specified. |
| 238 | S&F in repairs Gun metal gate valve with iron wheel head screwed both ends for GI steel tubing 50mm dia complete all as specified. |
| 239 | Taking up or down 25 mm dia bore GI tubing, and connections, including cleaning for re-fixing or removal to store complete all as specified. |
| 240 | Supply, fixing & laying of 25 mm dia bore GI tubing, medium grade with and including all fittings and fixture like socket, nipple, elbow, reducer etc complete laid in trenches or laid in floor complete all as specified. |
| 241 | S&F in repairs Gun metal gate valve with iron wheel head screwed both ends for GI steel tubing 25mm dia complete all as specified. |
| 242 | Taking up or down 20 mm dia bore GI tubing, and connections, including cleaning for re-fixing or removal to store complete all as specified. |
| 243 | Supply, fixing & laying of 20 mm dia bore GI tubing, medium grade with and including all fittings and fixture like socket, nipple, elbow, reducer etc complete laid in trenches or laid in floor complete all as specified. |
| 244 | S&F in repairs Gun metal gate valve with iron wheel head screwed both ends for GI steel tubing 20mm dia complete all as specified. |
| 245 | Supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 16 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe including taking out of old unserviceable cable etc complete all as specified and directed. |
| 246 | Supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 16 Sqmm 4 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc including taking out of old unserviceable cable complete all as specified and directed. |
| 247 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in soft / loose soil and geting out complete all as specified and directed. |
| 248 | Material and labour for sand cushioning with dry fine sand including filling, spreading, levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed. |
| 249 | Material and labour for contineous brick edging with width equal to the depth of the brick of whole sub class 'B' bricks laid on edge complete all as specified and directed. |
| 250 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in 25mm thick layer complete all as specified and as specified. |
| 251 | Removal of surplus excavated soil to a distance exc50 m but not exc in 100 m and deposited wher directedat a leveln exc 50 m above the starting point complete all as specified. |
| 252 | Supply / laying and fixing 40 mm bore galvanised steel tubes with all fittings, light grade, laid in trenches for cable protection complete all as specified and directed. |
| 253 | S&F in repairs rigid PVC pipe medium grade 20 mm all as specified and directed. |
| 254 | S&F in repairs rigid PVC pipe medium grade 25 mm all as specified and directed. |
| 255 | S&F in repairs Casing capping 20 mm heavy duty all as speciifed and directed. |
| 256 | SS&F in repairs Casing capping 25 mm heavy duty all as speciifed and directed. |
| 257 | S&F in repairs Flexible pipe PVC 20 mm size all as specified and directed. |
| 258 | Supply only 15 mm saddle all as specified and directed. |
| 259 | Supply only 20 mm saddle all as specified and directed. |
| 260 | Supply only 25 mm saddle all as specified and directed. |
| 261 | S&F in repairs 1100 volts grade heavy duty 2 core x 10 Sqmm cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire, one twin core cable circular complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 15 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender