Tender For Special Repair Replacement Under Certain Sectioned Work And Provn Of Lt Cable For Generator At 436 Coy Asc Sup Depot At Bairagarh Under Ge Bhopal
Tender Value
47.87 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
15 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair Replacement Under Certain Sectioned Work And Provn Of Lt Cable For Generator At 436 Coy Asc Sup Depot At Bairagarh Under Ge Bhopal
BOQ
| Sl. No. | Item Description |
| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | Supply, install, commissioning and testing Mortuary cabinet suitable for single phase, 230 V, 50 Hz, with 0.55 mm thick exterior & interior finish pre painted GI sheet, 0.5 mm thick front finish in stainless, including vapour proof incandescent lamp, electric temperature indicator cum controller, 3 phase carriage assembly, one piece stainless steel tray, inbuilt power panel etc. suitable for unitary type refrigeration system and temperature range of 4-6ºC of capacity of Body 02 nos complete all as specifed and directed.Make- Bluestar/Voltas/Daikin/carrier |
| 3 | Supply, install and testing and commissioning of Vertical Turbine Motor and pump of 75 HP of Flow, rated : 270.0 m3/h , for Head not less than 45m Suction pressure, Frequency 50 Hz, Speed rated 1450 rpm, including MS column pipe dia 200mm not less than 12M length duly painted anti corrosive paint internally and externally alongwith impellors, SS shaft, strainer etc as per OEM recommendations, arrangement for anchoring of pump 8mm SWG wire not less than 15M length, Bowl- CI IS210:FG260 (012), Impeller: ST ST ASTM A351/M-CF8M (232), Casing Ring: ST ST ASTMA276/A240 TYPE 316 (914), Shaft: ST ST ASTMA276-410 ANLD (253), Suction Strainer: MS (502) ; etc including connections to existing system alongwith required nut bolt and gaskit etc complete all as specified and directed. Make- Kirloskar/Crompton Greaves/KSB |
| 4 | Dismantling of VT pump from raw water filteration plant and deposited to MES Store yard complete all as specified and directed |
| 5 | Dismantling Mortury cabinet from existing site and deposited to MES Store yard complete all as specified and directed. |
| 6 | S & Fix MS pipes heavy garde for VT Pump connection including flanges and welding and painting of pipe red oxide one coat and synthetic enamel black paint 2 coats as per site requirement complete all as specified and directed. |
| 7 | M&L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized iron strip 32X6mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 part – I connected to machinery/equipment for Timer Panel etc. as required 32x6 mm dia galvanized iron with 40mm GI light Grade pipe for protection including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thick in PCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and 20mm bore GI watering pipe medium grade, etc. complete all as specified and directed. |
| 8 | All as per ser item no 6.00 here-in before but using 4 mm GI wire as earthing lead and MS galvanized plate of size 60 cm x 60 cm x 6 mm, as earth electrode complete all as specified and directed. |
| 9 | Supply and fix 10 KVA Online UPS , 360 to 384 V DC 3 phase input supply and 3 phase output supply with In Built Transformer with 20 Amps Inbuilt Battery Charger parallel redundancy, Hot standby feature 12 Volt 42 AH SMF Battery 32 Nos, for 30 Min Backup including battery Rack and interlinking to batteries for 32 Batteries and bypass arrangement complete all as specified and directed. |
| 10 | M&L in replacement for sub main wiring (Three phase) with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 10.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Four runs of 10.0 sqmm cable & one run of 10.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. |
| 11 | Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 10.00 sqmm 4.0 core all as specified & directed. Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule) |
| 12 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed. |
| 13 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed |
| 14 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 15 | M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed. |
| 16 | M&L for providing of un-reinforced precast concrete cable cover class LV, Type 1 size 250mmx 150mm x 40mm laid flat dry for protection of under ground cable complete all as specified and directed.class,, flat, |
| 17 | M & L GI Tubing \\"light grade\\" galvanized for protection LT Cable all as specified of size 25 mm bore complete all as specified and directed by Engr-in-Charge. |
| 18 | S&F 1200mm with BEE 5 star rating complete aerodynamics aluminium blades & body decorative model with air delivery 220-230 CFM advanced BLDC 100% copper winding motor with all accessories such as regulator connecting down rod, clamps, conopy, low noise RF remote control for all direction sensing ribbed blades for high strength, reverse rotation feature available for circulating warm air during winter remote with boost, timer upto 8 hours, sleep, breeze & mop modes, model should be ISI marked including taking unserviceable ceiling fan and deposit to MES store yard complete all as per specified and diected.Note: Warranty card of ceiling fans to be down submitted to Eng-in-Charge before claiming payment. |
| 19 | Taking down regulator sealing cable ends and remaining regulator to deposit to MES store yard complete all as specified and directed by Eng-in-Charge. |
| 20 | Deduct Schedule of credit (calculation will be done off line) Rs. 0.00 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender