Tender for Procurement Of Dual Dome Led Light With Camera And Recorder For Orthopaedic Ops Theatre, Provn Of 50 X Desert Cooler For Afmsd, Installing Of Exhaust Fan In Bldg No P-74, T-41, T-42, T-45, T-46, T-47, T-48 And T-113 And Flame Proof Wiring In Bldg No P-71 (Medical Store) At Bhdc Under Ge (East) Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of the existing double dome OT light with all accessorise complete in all aspect and deposited to MES store yard incl transport complete all as specified and as directed. |
| 2 | Supply, Installation,Testing and Commissioning of High-End Dual-Dome LED Surgical Lighting System with following specifiecations:-1. LED Light Head Specifications (Double Dome)(i) Model:LED 50 (Double Dome Configuration).(ii) Illumination Intensity: Minimum 160,000 Lux per dome at 1-meter distance.(iii) Color Temperature: Adjustable range from 3,500K to 5,000K to allow for high-contrast visualization of bone vs. soft tissue.(iv) Color Rendering Index (CRI): Ra ≥ 95 and R9 ≥ 95 (for superior red color reproduction).(v) Light Field Diameter: Adjustable from 100mm to 300mm to suit various orthopedic procedures.(vi) Shadow Management: Advanced multi-lens geometry to ensure shadow-free illumination even when the surgeon's head or hands obstruct the light path.(vii) Service Life: Minimum 50,000 to 60,000 hours of LED life. |
| 3 | 2. Integrated Imaging System (Sony HD)(i) Camera: Built-in Sony HD Camera (Integrated in the center of one dome or on a separate third arm).(ii) Resolution: Full HD (3840x2160p).(iii) Zoom: Minimum 20x Optical Zoom with 12x Digital Zoom.(iv) Control: Sterile handle control or remote control for iris, zoom, and focus.(v) Recording Unit: Medical-grade HD Video Recorder.(vi) Internal storage with USB/Network export capabilities for surgical documentation and teaching.3. Display & Mounting(i) Medical Grade Monitor: Minimum 27-inch Full HD LED Monitor mounted on a dedicated spring arm.(ii) Must feature anti-reflective coating and high contrast ratio for orthopedic imaging (X-rays/C-Arm feeds).(iii) Suspension System: Heavy-duty ceiling-mounted 360° rotating arms with feather-touch movement and stable positioning (zero-drift).4. Safety & Standards(i) Aerodynamic Shape: Open design to facilitate laminar flow in the OT.(ii) Endo-Mode: Integrated ambient lighting for laparoscopic or minimally invasive orthopedic assisted procedures.(iii) Certifications: Mnufacturer should have ISO 13485:2016 should meet IEC 60601-1-2 & IEC 60601-2-41 Standard Make- Styker/ Getinge/ Hospedia Medicare |
| 4 | Supply, Installation,Testing and Commissioning of a ceiling-mounted LED 50 Double Dome OT Light, providing a maximum intensity not less than 160,000 Lux per dome at 1 meter; featuring adjustable color temperature from 3,500K to 5,000K, a Color Rendering Index (CRI) of Ra ≥ 95, and an adjustable light field (100mm–300mm) for orthopedic cavity depth; includes an aerodynamic, laminar-flow-compatible design and a heavy-duty, 360° rotating suspension system complete all as specified under BOQ item No 2.00 & 2.01 here-in-before and as directed. |
| 5 | Supply, Installation,Testing and Commissioning High-definition Sony HD camera system integrated within the surgical light dome (or on a separate dedicated arm), offering resolution (3840 x 2160p) resolution; features a minimum 20x optical zoom and 12x digital zoom, autofocus, and manual iris control via a sterile handle or remote interface to provide high-detail visualization of bone alignment and surgical site procedures complete all as specified under BOQ item No 2.00 & 2.01 here-in-before and as directed. |
| 6 | Supply, Installation,Testing and Commissioning Dedicated Medical Grade 4K HD Video Recording Unit compatible with the Sony camera feed; capable of real-time recording to internal storage and external USB/ HDD media; features high-bitrate compression for crystal-clear playback, a user-friendly interface for patient data entry, and network connectivity (LAN) for surgical archiving and teaching purposes complete all as specified under BOQ item No 2.00 & 2.01 here-in-before and as directed. |
| 7 | Supply, Installation,Testing and Commissioning Medical Grade LED Monitor Display 30-32 inch Medical Grade Full HD LED Monitor with aspect ratio 16:9/16:10 resolution 1920x1080 or higher mounted on a dedicated, height-adjustable spring arm; features a high-contrast ratio and anti-reflective coating optimized for viewing high-detail orthopedic images (X-ray, C-Arm, and Camera feeds); must include multi-input support (DVI, HDMI, SDI) and be designed for easy disinfection in a sterile environment complete ready with cables for integration of High Definition Digital (DVI/HDTV),RGBHV(High resolution),SVHS(S-Video), composite video signal to travel from the various source of video while assuring native resolution and signal complete all as specified under BOQ item No 2.00 & 2.01 here-in-before and as directed. |
| 8 | S&F of desert cooler of size > 25\\"x25\\"x36\\" (inch), fabricated with GI sheet of thickness 20 SWG, door panels made out of 24 SWG fitted with suitable door handle, heavy duty exhaust type fan motor, copper winding in three speed mode (Low, medium and high) having > 1400 RPM, Exhaust type fan blade of 18\\" size, material of fan blade and hub should be metal type, grass wool cooling pads, front grill with louvers should have been metal type, heavy duty ISI marked submersible pump having output head more than 1 mtr, GI wire mesh with pad set size 1'x1', whole body should be painted with double coat of synthetic enamel paint over a coat of red oxide primer of good wuality complete all as specified and as directed. Make of motor: Khaitan/ Crompton/ Usha |
| 9 | M&L for point wiring concealed type with 1.5 sq mm Nominal cross sectional area, single core, 1100 Volt grade, multi stranded, PVC insulated, unsheathed FRLS copper conductor cable and connected to common earth and earth dollywith suitable copper lugs and drawing into and including rigid non-metallic PVC Concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and modular PVC box, modular white cover plate with frame, blanking plate and required modular switches of 6 Amp rating (nothing extra in this respect paid to the contractor) etc suitable for upto required module etc complete and making good disturbed surfaces to match the existing for one light / bell / fan point controlled by one, one way switch 06 Amp, complete all as specified and as directed. |
| 10 | M&L for 300 mm sweep heavy-duty exhaust fan with strong air suction, high-speed performance at 1400 RPM, and 1710 CMH Air delivery specially designed blades, and built-in bird guard, including cutout size of 325 mm in wall/window as directed by the Engineer-in-Charge, electrical connection using flexible PVC copper wire from ceiling rose to the exhaust fan, necessary grouting, nuts, bolts, and making good the damages, all complete as specified and directed. |
| 11 | M&L for 380 mm sweep heavy-duty exhaust fan with strong air suction, high-speed performance at 1400 RPM, and 3250 CMH Air delivery specially designed blades with motor capacity 150 watt, and built-in / wall mounting type bird guard, including cutout size of 405 mm in wall/window as directed by the Engineer-in-Charge, electrical connection using flexible PVC copper wire from ceiling rose to the exhaust fan, necessary grouting, nuts, bolts, and making good the damages, all complete as specified and directed. |
| 12 | M&L for 450 mm sweep heavy-duty exhaust fan with strong air suction, high-speed performance at 1400 RPM, and 6120 CMH Air delivery specially designed blades having motor capacity 350 watt, and built-in / wall mounting type bird guard, including cutout size of 490 mm in wall/window as directed by the Engineer-in-Charge, electrical connection using flexible PVC copper wire from ceiling rose to the exhaust fan, necessary grouting, nuts, bolts, and making good the damages, all complete as specified and directed. |
| 13 | S&F sub main wiring with 2 runs of 4 Sqmm, single core, PVC insulated & unsheathed cable FRLS-H, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 20 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 4 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- (Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length). |
| 14 | S & F MCB SP, 240 Volts, 16 Amps complete all as specified and directed. |
| 15 | M&L for a complete flame-proof and explosion-proof (Ex-d/IP66 certified for Zone 1 & 2, Gas Groups IIA/IIB) electrical wiring system for the medical store, comprising heavy-duty, threaded rigid Galvanized Iron (GI) conduits of size 25 mm with flame-proof junction boxes and double-compression cable glands 1100V-grade Flame Retardant Low Smoke Halogen Free (FRLS-H) stranded copper conductors (1.5 sq. mm} drawn through concealed conduits for lighting circuits spark-free interlocked switch (6A) and die-cast aluminum alloy switchgear enclosures; flame-proof, toughened-glass LED cleanroom light fixtures; and a dedicated dual-body chemical copper earthing system maintaining an earth resistance below 1 ohm to prevent static discharge, inclusive of all civil routing, cutting chasing, structural mountings complete all as specified and as directed for the following:- |
| 16 | Description all as per item no 10.00 here in before for one light controlled by one 5Amp switch |
| 17 | Supply and fix LED light fitting 2 x 16 watt flame proof, CMRI certified recommended for gas /vapour group of II A & III B , Zone 1 and 2 and IP 65 protected with die cast aluminium housing with heat resistance toughnened glass with LED tubelight fixures driver, holder, connector etc complete with all acessories prewired and including connecting up with three core flexible copper conductr cable with suitable size complete in all aspect all as specified and as directed. |
| 18 | Supply, installation, testing, and commissioning of Flameproof / Explosion-Proof LED Security Light Fixture of 90 watt capacity (Zone 1 & 2, Gas Group IIA/IIB/IIC, IP66, die-cast aluminum alloy LM-6 enclosure with toughened glass diffuser and internal/external earth terminals), complete with fabrication and fixing of heavy-duty MS/GI mounting brackets, base plates, clamps, and stainless steel hardware for secure installation on the rooftop of the Medical Store Building, including anti-corrosive primer coating, termination with flameproof double-compression brass cable glands, and proper grounding as per IS/IEC safety standards all as specified and as directed. |
| 19 | Supply and Fixing for the replacement of flameproof sub-main wiring, comprising 2 runs of 1.5 sq. mm circuit wires plus 1 run of 1.5 sq. mm earth wire, single-core, 1100V grade, Flame Retardant Low Smoke Halogen Free (FRLSH) insulated, multi-stranded copper conductor cables. The cables shall be drawn through newly laid surface-mounted, heavy-duty threaded Galvanized Iron (GI) flameproof conduits of size 25mm, complete with IP66 certified flameproof junction boxes, double-compression cable glands, suitable size tinned-copper lugs, gas-tight terminations, and testing connections at both ends as required at site to ensure zone-rated hazardous area integrity as directed. Note: The combined assembly consisting of two runs of circuit cable, one run of earth conductor, and the rigid heavy-duty GI flameproof conduit with its inline fittings shall be measured and paid for as a single composite unit per Running Meter (RM). |
| 20 | Supply, installation, testing, and commissioning of a wall-mounted, Flameproof and Explosion-Proof 6 Way SPN Lighting Distribution Board , certified for Gas Groups IIA/IIB (Zone 1 & 2) with IP66 weather, dust, and vermin protection. The enclosure shall be manufactured from heavy-duty Die-Cast Aluminum Alloy (LM6) , finished with anti-corrosive epoxy powder-sprayed primer and paint. The unit must feature a bolted flame-path cover/door with high-tensile stainless steel fasteners, external rotary operating knobs for circuit breakers, and internal flameproof compartments. Wiring shall be executed using suitable size 1100V-grade FRLSH/HFFR copper conductors, complete with Ex-d certified double-compression brass cable glands, earthing terminals, and mounting accessories, factory-fitted with the following switchgear:(a) Incomer: 32A, Double Pole (2P) MCB, 10kA – 01 No.(b) Outgoings: 6A, Single Pole (1P) MCB, 10kA – 04 Nos. |
| 21 | Supply, installation, testing, and commissioning of a Flameproof (Explosion-Proof) and Fire-Retardant 6A, 240V AC Single Pole Switch, suitable for installation in Zone 1 & Zone 2 hazardous areas (Gas Groups IIA, IIB, and IIC, Temperature Class T6) and featuring a minimum IP65/IP66 ingress protection rating. The enclosure shall be manufactured from heavy-duty die-cast aluminum alloy (LM6) or high-grade UL 94 V-0 fire-retardant self-extinguishing polymer, equipped with heavy-duty silver alloy internal contacts, stainless steel (SS304/316) external hardware, and internal/external earthing terminals. The unit must include a minimum of two threaded cable entries complete with certified flameproof double-compression cable glands and blanking plugs, fully tested and certified by recognized authorities (CIMFR, PESO, ATEX, or IECEx), with the rate encompassing all necessary mounting accessories, hardware, and terminations required for a complete, operational installation as per site requirements. |
| 22 | M&L Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the platee not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical platee No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 B1 with 8 mm dia MS bars at 100 c/c, funnel, watering pipe etc. all specified and directed including testing on completion. |
| 23 | Supply, Laying and Testing 6 sqmm 2 core XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade cross-sectional area 6 sqmm directly in ground including necessary excavation of trench, sand cushioning, protective brick laying on top, backfilling, compaction, and making complete end connections with suitable glands/lugs from nearest panel complete in all aspect all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender