Tender For Repair/ Maintenance Of Feeder Pillar And Switch Gears, High Mast Including Allied Works Under Age E/M Of Ge 871 Ews.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Aug 2026
12 days left
EMD
17300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chamoli → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Feeder Pillar And Switch Gears, High Mast Including Allied Works Under Age E/M Of Ge 871 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE 'A' PART-I : BOQ OF WORKS FOR E/M WORKS. |
| 2 | LED Flood light fitting 150 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, connecting up with three core flexible copper conductor cable of suitable size, and including house service bracket for mounting light fittings. House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.Make: Havells cat part No- JETAADORNFLS150WLED757SSYMTOTGV3 or equivalent in Phillips/ Bajaj/ Crompton. |
| 3 | PVC insulated and PVC round Sheathed, cross-sectional area, 2.50 Sqmm, 3.0-core, multi-stranded, annealed bare copper conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694:2010, complete all as specified and directed. |
| 4 | Preparation of surfaces of old painted steel tubular swaged poles LT poles of any size, any section and any height, cleaning the surface with mild steel wire brush and painting pole with one coat of black and white synthetic enamel paint in alternate strips, 30 cm thick each, up to 1.50 mtrs height from the top of coping including marking pole Nos with synthetic enamel paint, in uniform size black colour paint on circle with yellow paint, including painting rest height with two coats of aluminium colour painting with cross arms, bracing, clamps, nuts, bolts etc complete all as specified and as directed. |
| 5 | Aluminium strip 25mmx3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, fixing in repairs, complete all as specified and as directed. |
| 6 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4200 13 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB. |
| 7 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4200 15 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB. |
| 8 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 125 Amps with breaking capacity 25 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4200 16 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB. |
| 9 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 160 Amps with breaking capacity 25 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4200 57 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB. |
| 10 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 250 Amps with breaking capacity 25 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4202 19 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB. |
| 11 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 400 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4220 07 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB. Please Enable Macros to View BoQ information |
| 12 | Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 400 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4220 07 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender