Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #57063272

Tender For Special Repair To Petroleum Oil And Lubricant (Pol) Stores At Certain Locations Under Ge (Af) Srinagar.

Issued by Statutory Bodies & Commissions/Committees · Budgam, Jammu and Kashmir
Tender Value
46.25 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
10 days left
EMD
92500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Petroleum Oil And Lubricant (Pol) Stores At Certain Locations Under Ge (Af) Srinagar.

BOQ

Name of Work:- SPECIAL REPAIR TO PETROLEUM OIL AND LUBRICANT (POL) STORES AT CERTAIN LOCATIONS UNDER GE (AF) SRINAGAR.
Sl. No. Item Description
1Schedule 'A' Part-I (B/R Work)
2Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
3M&L for 15mm thick rendering on fair faces on brick or concrete surfaces in CM 1:4, fair finished the surfaces even and smooth without using extra cement complete all as specified and directed.
4M&L for 15mm thick rendering on other than fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and directed.
5M&L for applying one coat of 1mm thick wall care putty over plastered surface to prepare the surface even and smooth, complete all as specified and directed.
6Preparation of newly plastered surfaces of wall sides and soffits of the beams, ceilings, fascia's, parapets etc. and applying two coats of weather paint (Apex) over a coat of exterior primer on, colour and tint as directed in any pattern including scaffolding up to 15m height, complete all as specified and directed.
7Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
8Preparation of old plastered surfaces of wall by washing down, brooming down or steel wire brushing etc. and applying one coat cement base paint including scaffolding up to 15m height, complete all as specified and directed.
9Complete removal of existing treatment of walls and applying thin layer of wall care putty and prepare the smooth surface with sand paper and applying two coats of distemper oil emulsion (OBD) paint over a cot of primer, complete all as specified and directed.
10Demolition of cement concrete (unreinforced) in ground floor and pavings not exceeding 15cm thickness (below or above ground level) and removal the rubbish/ demolished material outside defence land, complete all as specified and as directed.
11M&L for 75mm thick plain cement concrete, 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in plinth protection, joint filled with bitumen sand mixer finished even and smooth without extra cement, complete all as specified and directed.
12Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc., complete all as specified and directed.
13M&L for 20-25mm thick machine cut Kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing / grinding and polishing upto mirror finish complete over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed.
14M&L for 20-25mm thick machine cut kota stone slab as in riser of steps, skirting, dado and pillar jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing upto mirror finish over and including 10mm thick backing coat in CM 1:4, complete all as specified and directed.
15Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
16M&L for Glazed ceramic tile 300x600x06-7mm thick (coloured) on vertical surfaces such as wall, dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10mm thick screed bed in CM 1:4, complete all as specified and directed.
17M&L for Non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed.
18M&L for 25mm thick plain cement concrete, 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in sub base, complete all as specified and directed.
19S&F False ceiling with semi perforated 12 mm thick micro tegular edged at all height with GRG (glass fiber reinforced gypsum) false ceiling tiles of size 595x595 mm of approved texture, design and pattern having moisture content less than 2% , humidity resistance of 99% ,NRCO .50 to 0.75 as per IS 8225: 1987 , non combustible as per BS 476 (PART 4 ) -1970 and light reflectance of 85% (minimum ) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thickness ( galvanised@120 grams per sqm including both sides ) comprising of main T runner of size 15x32 mm length 3000 mm , cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross -T of size 15x32 of length 600 mm to form grid module of size 600x600 mm, suspended from the ceiling using galvanised mild steel items ( galvanisng a@ 80 gms per sqm ) i.e. 50 mm long 8 mm outer dia M-6 fastners , 6 mm dia fully threaded hanger rod upto 1000 mm length and L shaped level adjuster of size 85x25x2 mm galvanizing iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on perimeter wall/portion with the help of plastic rawl plug @450 mm center to center 40 mm long dry wall screw the work shall be carried out as per specification drawing including dismantling of existing ceiling, complete all as specified and directed.
20Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) n exc. 1.5 Sqm and credited to the contractor, complete all as specified and directed.Note: The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface.
21Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n exc 4.0 Sqm and credited to the contractor, complete all as specified and directedNote: The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface.
22S&F Box type steel window double frame (glazed & gauged) made of ERW tube P- section of size 60mm x 25mm double rebated outer frame comprise glazed Skelton shutter door frame of ERW tube P-section size 50mm x 20mm with two No's openable leaf consisting of two No's of sash bar of T-sec 20mm x 3mm welded to frame with one No vertical mullion of ERW of ERW box type T-section size of 60mm x25mm FI 2mm thick welded / screwed to frame for fixing of wire gauge/glass and 10mm Sqr Bar security grill including fixture and fitting like as handle, tower bolt stopper , cleat, pintail hinges, holdfast primer etc., complete all as specified and directed.(Note- sheet glass, wire mess will be measured and paid separately and window will be measured one side only)
23S&F 3mm thick sheet glass ordinary quality and glazing with oil putty / wooden beading in squares not exceeding 0.50 Sqm , complete all as specified and directed.
24S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
25S&F in repairs 1.25mm thick of laths of steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, push pull or manual type, complete all as specified and directed.
26S&F gear box of rolling shutter made up of worm gear. worm wheel, motor count gearbox case and drive shaft including making the shutter in operating condition, complete all as specified and directed.
27Taking down the existing rolling shutters from the existing opening and refixing the same in position after carrying out necessary repairs including oiling, greasing,easing out etc size of shutter exc 7.00 Sqm but n exc 12.00 Sqm each. complete all as specified and directed.
28Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
29S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed.
30S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed.
31S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, with L-type or J-type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating, complete all as specified and directed.
32All as per Ser item No 30.00 here in before but except Sheets.
33S&F 0.63mm thick Galvanised, Plain mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating, complete all as specified and directed.
34Preparing new zinc (or galvanised) surfaces to receive painting of any description over 10cm width or girth, by coating with mordant solution including washing and cleaning, etc. steel and iron surfaces and applying two coats of synthetic enamel paint in camouflaging CCD pattern as approved, complete all as specified and directed.
35Preparation of old painted steel and iron surfaces of any description not otherwise described exc 10cm width or girth by brooming down or steel wire brushing, scrapping down, smoke soot moulds, moss and efflorescent salts and greasy spots of roof /CGI Sheets, steel gates, steel doors, steel rolling shutters, steel eves boards etc. and applying one coat of synthetic enamel paint including scaffolding up to 15m height, complete all as specified and directed.
36Dismantling of timber scantlings 40 sqcm and over in section, in any position unframed work, complete all as specified and directed.
37M&L for structural steel work as in truss, rafter purling, made out of angle / Hollow pipe / tube section including jointing cleats, plates flat iron, gusset plates, rails, braces etc. conforming to Fe 410-W (gde-E-250) Quality, confirming to IS-1161-1979 of grade St-240, complete all as specified and as directed.
38M&L for rollled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates, wind Tie etc. conforming to Fe-410-W (gde-E-250) Quality A, complete all as specified and as directed.
39M&L for mild steel framed work such as grills, gratings, gates etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; nosing, framework of water tanks, band, straps, wind ties and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
40S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe-410-W (Gde-E-250) quality A, complete all as specified and directed.
41Preparation of new steel surface and iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over red oxide primer, complete all as specified and directed.
42Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for, complete all as specified and directed.
43Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work for fair finished surface, exceeding 200m thick (Horizontal or sloping), complete all as specified and directed.
44M&L for Reinforced cement concrete, 1:2:4, Type B-1 (using 20 mm graded crushed stone aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
45M&L for MS TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooking for columns, hooking ends and binding with and including mils steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
46M&L for MS TMT bars 05mm dia and over upto 10mm in in stirrups, spacers and binders, cut to length bent to shape required including cranking, bending spirally for hooking for columns, hooking ends and binding with and including mils steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
47Demolition of cement concrete (unreinforced) of any description in any position, complete all as specified and directed.
48M&L for 75mm thick plain cement concrete, 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base, complete all as specified and directed.
49M&L for Hard core of broken stone gauge not exceeding 63mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surfaces, complete, all as specified and as directed.
50M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and direction.
51M&L for plain cement concrete, 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregates), benching / copings and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
52Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
53M&L for brick work with sub-class `B' bricks (using old size bricks), straight or curved on plan exceeding 6m mean radius built in CM 1:6, Complete all as specified and directed.
54All as per Ser item No 52.00 here in before but except bricks.
55M&L for plain cement concrete, 1:3:6, Type C-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed.
56M&L for 100mm thick plain cement concrete, 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in flooring , laid in alternate bays and finishing the surface even and smooth without using extra cement, complete all as specified and as directed.
57M&L for forming contraction (Dummy) joint, 30mm deep x 10mm wide as the work proceeds in alternative ways and filled with sealing compound grade 'A' after priming with primer for grade 'A' sealing compound , complete all as specified and directed.
58Schedule 'A' Part-II (E/M Work)
59S&F in repairs 20x3.15mm Copper Strip with PVC insulators/ saddles and fixing screws etc. for roof conductors and down conductors, complete all as specified and directed.Note : i) Necessary T&P required for fixing of Copper strip is inclusive of rate quoted by contractor.ii) Site clearance after fixing shall be done by contractor.
60Supply, installation testing & commissioning of Lightning Protection (LA) set with following specifications:-a) Radius of Protection = 42mb) Current capacity= 200KAc) Additional protection= SFCHd) Weight= 2.5kge) Length= 505mmF) Accessories box with following 8 Nos M8 allen bolt with washer , 2 Nos M16 Expansion bolt G. I , 4 Nos of cable Tie nylong) Coupler and Mast with following:-Cemented flat surface installation with circular base plate haviong main pipe out diameteras 48mm & thickness3.2mm circular bottom plate of diameter 220mm and having thickness as 10mm is welded directly ewith the pipe to from a single piece of without nay joint for stability at bottom. The bottom plate is furnished with 04 Nos of 16mm holes for securing the mast on the Cemented flat surface made of G.I, At top of the mast insullation is provided from lightening arrestor via derlyn mast coupler(MC), The total height of mast is 4000mm.MAKE:-Ashlok(Zeus)/Baron/Macmate/SG
61Supply , installation testing & commissioning of maintenance free compound based electrode earthing with following Specificationsa) Type = Copper Bonde Rodb)Material = Low carbon steel core (SAE 1018)c) Length = 3000mmd) Dia of rod = 17mme) Coating Thickness = 250 micronsf) Terminal = U Bolt Clamp or equivalentg) Tolrence in length = ± 20mmh) Tolrence in diameter = ±1.0mmi) Torence in thickness = ±0.03mmj) Current with stand = 10 KA for 1.0 sec and 25 KA peakk) Frequency = 50 Hzl) Back fill compound = BARON ELECTRODITE (ROHS Certification)m) PIT Cover = FRP (or) EPCCn) Granular material resistance = 0.001 Ohmo) Mixer ratio with cement = 3:1NOTE:- Electrode top terminal shall be sealed permanently packed with conductive concrete and CU bonded strip taken out be terminated on earth test point and equipped terminalMAKE:-Ashlok(Zeus)/Baron/Macmate/SG
62S&F HDPE pit cover for chemical earthing, Earth pit, complete all as specified and directed.
63S&F in repairs test point terminal block made out of Gun metal or phosphorous bronze of size 75 mmx75 mm x25 mm drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screws, complete all as specified and directed.Note : - The following items also included and rate to be quoted accordingly.(a) Taking up or down GI socket 40mm / reducer socket 50x 40mm bore including aluminium gutaka.(b) Fixing only GI socket 40mm bore , on vertical pipe post / stand.(c) Old retrieved GI socket obtained in serviceable condition shall be re-used in the work.
64S&F in repairs 50 x 32mm DWC (Double wall corruguated) pipe conforming to IS: 14930 / IS 16205 for protection of earth strip including necessary snap-fit coupler required for fixing, complete all as specified and directed.
65M&L for copper earthing complete with 600mm×600mm×3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No. 3 connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down old one, complete all as specified and directed. NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
66S&F single core 25 Sqmm copper multistandred conductor PVC insulated and unsheathed (FRLS) Earth wire using ISI Marked IS 694 1100 volts grade PVC insulated flexible stranded copper conductor wire, complete all as specified and directed.
67M&L for flame proof point wiring for One light / fan point controlled by one way switch 6 amps 240 volts with 2.5 Sqmm copper conductor ZHFR (multistrand) PVC insulated ISI marked unsheathed cable in and including surface, stove enamelled steel conduit, medium grade, ISI marked conduit not less than 19mm with all fittings & other accessories and also including PVC insulated ISI marked unsheathed ZHFR cable of size 2.5 Sqmm copper conductor as earth wire to common earth dolly controlled by one flame proof switch (colour code of wiring should be for phase-Red, Neutral-black & earth wire-green), complete all as specified and directed.
68Sub main wiring with two runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 6.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with one run of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 6.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Note :2 runs of 6 sqmm copper cable & 1 run of 6 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit.
69S&F in repairs flame proof rotary type 16 Amps switch with terminal box in LM 6, single pole, complete all as specified and directed.
70S&F Flameproof and Explosion Proof Exhaust Fan, 300mm sweep, 0.25 HP, 1440 RPM, weatherproof and dustproof enclosure, suitable for operation on 230 V AC supply, certified for Zone-1 & Zone-2 hazardous areas, LM6 grade certified by CIMFR for Gas Group IIA, IIB & IIC, protection type Ex-d, IP-65 protection, die-cast aluminium alloy body, complete with motor, fan blades, mounting frame, fixing accessories, nuts, bolts, washers and all connected works, complete all as specified and directed.
71S&F flame proof LED 60 Watt, CMPRI certified, well glass LED light recommended for Gas/vapour group of II A & II B and Zone 1 & 2 with die cast aluminium housing with heat resistance glass IP 65 protection and all accessories as per manufacture norms & including 3 core flexible cable from ceiling rose to connector of fitting etc., complete as specified and directed.
72S&F MCB of single poles and current carrying capacity 6 to 32 Amp, 240V, 10 KA 'C' curve, in the MCB DB complete with connection testing and commissioning, complete all as specified and directed.
73S&F MCB of double poles and current carrying capacity 32 Amp, 240V, 10 KA 'C' curve, in the MCB DB complete with connection testing and commissioning, complete all as specified and directed.
74S&F epoxy powder coated or polystrene insulated material sheet metal enclosure, factory made, (double door) 8 way single pole & neutral suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting, complete all as specified and directed.
75M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc., complete all as specified and directed.
76Supply, laying, jointing, testing XLPE insulated PVC sheathed with stranded aluminium conductor heavy duty, size of cable 16 Sqmm 2 core, conforming to IS 1554 Part I / ISI marked, 1100 Volt grade, including cable glands , cable lugs etc, to suitable the cable size, cables to be laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc. including taking out unserviceable cable, complete all as speccified and directed.
77M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.25 mtr below normal ground level, connected to galvanized iron wire 4mm dia by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm gradedcrushed stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe including taking down old one, complete all as specified and directed.Note: (i) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (ii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department.
78Supply, installation, testing and commissioning, factory made, busbar chamber with factory-made, wall-mounted, dust, vermin and weather-proof busbar chamber of size 300mm × 150mm × 200mm, fabricated out of 3.15mm thick CRCA mild steel sheet, having degree of protection not less than IP-65, suitable for 3-phase, 415 Volts, 50 Hz AC supply. The chamber shall be complete with aluminium busbars of 200 Ampere rating, of size 32 mm × 6 mm for three phases and neutral, duly insulated with heat-shrinkable sleeves of approved colour code and mounted on epoxy insulators, complete with minimum two incoming and two outgoing cable termination provisions, suitable cable glands, hinged lockable door, danger notice plate, powder coated finish, common earth terminal with earthing arrangement and all fixing accessories including dismantling of existing unserviceable busbar chamber, mounting in position, termination of incoming and outgoing cables, testing and commissioning complete, including all cutting, drilling, making good and other incidental works, complete all as specified and directed.
79Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc., complete all as specified and directed
80Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing, complete all as specified and directed.
81Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point, complete as specified and directed.
82Deduction to be made from BOQ for Schedule 'A' Part-III (Credit Schedule from dismantling / taking down items) worth Rs 1,06,335.00 during AOC. (Note :- Tenderers shall not quote for this Schedule) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57063272
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.25 Lakhs
LAST DATE 08-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Petroleum Oil And Lubricant (Pol) Stores At Certain Locations Under Ge (Af) Srinagar.
Basic Detail
Tender No GE(AF)/SGR-61/2026-27
Bidding Type Tender
Location
City Budgam
State Jammu and Kashmir
Key Dates
Publish Date 17 Aug 2026
Submission Date 08 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 46.25 Lakhs
Tender Fee 500
EMD 92500
Exemption Available
Document List
BOQ_879329.xls
cf254441-005e-4890-b216-c8b486ac0906.html
Tender61.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_879329.xls

html

cf254441-005e-4890-b216-c8b486ac0906.html

pdf

Tender61.pdf

pdf

Tendernotice_1.pdf