Science and Technology Statutory Bodies & Commissions/Committees Closing in 2 days TDR #57062845

Tender For Annual Maintenance Contract Of Electrical Work For Colony Staff Quarters Including Street Lighting And Non-Residential Buildings At Csir-Csio, Sector-30,Chandigarh.

Issued by Statutory Bodies & Commissions/Committees · Chandigarh, Chandigarh
Tender Value
51.01 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
2 days left
EMD
1.02 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Maintenance Contract Of Electrical Work For Colony Staff Quarters Including Street Lighting And Non-Residential Buildings At Csir-Csio, Sector-30,Chandigarh.

BOQ

Name of Work:- Annual Maintenance Contract of electrical work for colony staff quarters including street lighting and non-residential buildings at CSIR-CSIO, Sector-30,Chandigarh.
Sl. No. Item Description
1Sub Head-I :- Man PowerNote: Before Quoting the rate, contractors should ensured that Per Month Rate for Item No. 1.01, 1.02 and 1.03 should not be less than Rs. 102876.00, 94734.00 and 88062.00 per month, respectively, as per statutory requirement as on 31.03.2026. This is the minimum estimated saturatory requirement amount for compliance of the labour laws, which is based upon minimum wages declared by DC Chandigarh for the F.Y. 2025-26 + EPF @13% on Rs. 15000 + ESI @3.25% (If applicable) + Bonus @8.33% (If applicable) + @1% labour cess + GST@18% but without contractor's profit. Further, the contractors are advised to quote their rates based on the current applicable DC rates notified by the Chandigarh Administration, applicable statutory requirements, if any, and contractor’s overheads and profit over the minimum statutory amount. Note:- The payment on account of enhancement/ reduction charges on account of revision in wages by DC, Chandigarh Administration or change in current norms of PF/ESI/Bonus etc, after date of reciept of tenders shall be payable by the CSIR-CSIO to the contractor as per contract coditions .
2Deployment of Electrician - 03 Nos. for day to day general repair & maintenance of the Electrical Installation, power distribution system, fitting & fixture, security lights, electrical panels, electrical operation, upkeeping of residential and non-residential buildings area in CSIR-CSIO campus area as and where required.
3Deployment of Assistant Electrician (Technician Gr-II) - 03 Nos. for day to day general repair & maintenance of the Electrical Installation, power distribution system, fitting & fixture, security lights, electrical panels, electrical operation, upkeeping of residential and non-residential buildings area in CSIR-CSIO campus area as and where required.
4Deployment of Semi Skilled Helper - 03 Nos. for day to day general repair & maintenance of the Electrical Installation, power distribution system, fitting & fixture, security lights, electrical panels, electrical operation, upkeeping of residential and non-residential buildings area in CSIR-CSIO campus area as and where required.
5Sub Head-II :- Supply of materialFollowing material will be supplied during the execution of maintenance work (to be used by the above stated deployed man power) from time to time as and when required.Specification and make of the material will be used as per annexure attached.
6Single pole 5/6 amps, one way switch, piano type ISI marked
7Single pole 5/6 amps, two way switch, piano type ISI marked
8Single pole 15/16 amps, one way switch, piano type ISI marked
93 pin 5/6 A socket outlet ISI marked
106 pin 15/16 & 5/6 amps socket outlet ISI marked
11Modular one way switch ISI marked 5/6 A of different Make/models as per requirement Anchor/legrand
12Single pole 15/16 amps, one way modular switch, ISI marked of different Make/models as per requirement.
133 pin 5/6 amps modular socket outlet, ISI marked of different Make/models as per requirement.
146 pin 15/16 amps modular socket outlet, ISI marked of different Make/models as per requirement.
15Stepped type deluxe Fan regulator, 220/230V, 50Hz any one of make Legrand/Anchor/Havells/Usha
16Stepped type Modular Fan regulator (2 module) , 220/230V, 50Hz any one of make Legrand/Anchor/Havells/Usha
17Bell Push button, piano type switch
18Call Bell/Buzzer suitable for single phase, 230 V
19Key Guard Switch 03 Module, Complete in all respect with Key, PCB and Holder, Rating - 16 Ampere to 32 AmpereMake - Legrand, Anchar
20Capacitor 2.5 mfd to 4 mfd, single phase, 250/440 volts anyone of make Asian EPCOS / Bajaj / CG/Havels
21Electronic tube ballast/chock 1X36/40 watts, 230/250 volts 50 Hz. Bajaj Rezo models Philips/CG/Bajaj make. Compact and ordinary models.
22PVC insulated, FRLS/HFFR, single core copper conductor cable 1.5 sq. mm ISI marked, any one of Make - Ecko/Havells/Ralison /Anchor/V-Guard.
23PVC insulated, FRLS/HFFR, single core copper conductor cable 2.5 sq. mm ISI marked any one of Make - Ecko/Havells/Ralison /Anchor/V-Guard.
24PVC insulated, FRLS/HFFR, single core copper conductor cable 4.0 sq. mm ISI markedany one of Make - Ecko/Havells/Ralison /Anchor/V-Guard.
25PVC insulated, FRLS/HFFR, single core copper conductor cable 6.0 sq. mm ISI marked, any one of Make - Ecko/Havells/Ralison /Anchor/V-Guard.
26PVC insulated three core flexible cable of size 50/0.25mm (2.5 Sq.mm) copper conductor multi stand 1.1KV grade any one of make ECKO/ Empire/ National/ Kinjal/ Arr Kay Lite.
27Twin Flat Aluminium Conductor cable of size 2 x 10 sq.mm ,1.1 KV grade any one of make: Empire/Shalimar/swadeshi as required.
28PVC Batten/ Angle Holder any one of make Anchor model Anchor/ Deluxe / Penta NOA.
29Ceiling rose, 3 pin, 5 amp ,single phase 230/250 volts
30PVC conduit pipe, ISI marked of size dia. 25mm anyone of make Diplast/ Prince/ Finolex.
31Phonallic laminated sheet of 3 mm thick, ISI marked anyone of make Hylem/ Super/ Heylem.
32PVC batten of size 25 mm X 10 mm (casing & capping) ISI marked any one of make Diplast / Anchor or equivalent make.
33MS flexible pipe 25 mm dia with PVC coating along with all ancillaries and accessories like coupler etc. as required.
34PVC flexible pipe 25 mm dia of good quality as required.
35PVC gang box suitable for 2 switches and 2 sockets of 5amp. Complete in all respect as required at site.
36PVC gang box suitable for 1 switch and 1 socket of 15amp. Complete in all respect as required at site.
37Minor material like Gutties/ iron staples/ saddles/ Wire Cable Ties /Brass & jipsum screws for fixing the bakelite sheet with MS boxes, Nut-Bolts, PVC band etc. as required.
38Modular GI box 6 Module (nominal size) with suitable size of modular base sheet and cover plate complete in all respect as required at site.
39Modular GI box 3 Module (nominal size) with suitable size of modular base sheet and covr plate complete in all respect as required at site.
40Miniature circuit breaker, 6 A to 32 A rating of Single pole, 240/415 V, 10 kA, “C” curve, suitable for inductive load as required. Make - Legrand / Havells/L&T/Schneider
41Miniature circuit breaker, 6 A to 32 A rating of Double pole, 240/415 V, 10 kA, “C” curve, suitable for inductive load as required.Make - Legrand / Havells/L&T/Schneider
42Miniature circuit breaker, 6 A to 32 A rating of Triple Pole & Neutral , 240/415 V, 10 kA, “C” curve, suitable for inductive load as required.Make - Legrand / Havells/L&T/Schneider
43Residual current circuit breaker (RCCB) 40A, double pole, (single phase and neutral), 240 V, having a sensitivity of current 30 mA as required.Make - Legrand / Havells/L&T/Schneider
44Residual current circuit breaker (RCCB), 63 Amp., four pole, (three phase and neutral), 415 V, having a sensitivity current 30 mA as required. Make - Havells/L&T/Schneider
45SPN industrial type, socket outlet, 20 amps, 240 volts, with 2 pole and earth, metal enclosed plug top along with 20 amps 'C' series, SP, MCB, in sheet steel enclosure as required.
46Digital Time switch- Crono, with daily weekly programmable feature, Single phase 110-240 VAC, 50/60 Hz, GIC/ L&T make suitable for street light controls.
47MCB distribution board, 8 way, double door, single pole and neutral, sheet steel, 240 volts as required at site.
48Contactor of rating 18-25 Amp , 4 pole three phase 415 Volts, 50 Hz with coil operating voltage 220/400/ 440 V operation complete as required. Make - L&T or other similar.
49Contactor of rating 40-55 Amp , 4 pole three phase 415 Volts, 50 Hz with coil operating voltage 220/400/ 440 V operation complete as required. Make - L&T or other similar.
50LED Batten of rating 20W, minimum lengh 1100 mm, lumens effieciency not less than 100lm/watt, suitable for 230V, 50 Hz, single phase AC Supply, complete as required.Make Anchor, Bajaj, CG, Wipro/ philip
51Supply of full glow G5 recessed type 36 W LED Light Fitting of size 2' x 2', lumens - 3600 or more, operating voltage 230/250 Volts, 50Hz, suitable for office and complete in all respect with driver etc. Model/Make: RC370B LED36S of Philips OR equivalent model of Havells, CG or Wipro.
52LED Flood Light, 70 Watt, single phase 230V, 50Hz complete in all respect any one of make CG/ Osram/ Philips/Havells.
53LED Flood Light, 150 Watt, single phase 230V, 50Hz complete in all respect any one of make CG/ Osram/ Philips/Havells.
54LED street light fitting of rating 20 Watt , single phase, 230V, 50Hz complete in all respect. Any one of make CG/Osram/Philips
55LED street light fitting of rating 36 Watt , single phase, 230V, 50Hz complete in all respect. Any one of make CG/Osram/Philips
56LED type street light fitting of rating 72 Watt, single phase 230V, 50Hz complete in all respect. Any one of make CG/Osram/Philips
57Underwater Luminaries surface mounted RGB LED spot light Fountain Light, 12 Volt, 15 Watt - 25 Watt, IP - 68 , Angle - 30◦ to 45°, Colour - RGB, Complete in all respect
58LED lamp 12-15 watt, pin/screw type, single phase, 230V, 50Hz any one of make CG/Osram/Philips/Havells.
59LED lamp 23-25 watt, pin/screw type, single phase, 230V, 50Hz any one of make CG/Osram/Philips/Havells.
60GLS Incandescent Bulb 60-100 watt, 220Volt, 50Hz
61LED type street light fitting driver/ controller of 36/40 watts and LED plate 36 watt complete in all respect as required at site.
62LED type street light fitting driver/ controller of 72/80 watts and LED plate 72 watt complete in all respect as required at site.
63Globe/dome diffuser of size 12\\" suitable for pole mounted street light pole as rquired.
64Post Top Lantern out door light fitting suitable for fixing retrofit LED lamp, 220-240 Volts, 50Hz, suitable for 40 to 60mm O.D. mounting pipes, complete with LED retrofit lamp of 9W, of good quality as approved by the Engineer-In-charge.
65LED bulb 5 Watt 3000k warm white, screw type, single phase, 230V, 50Hz model/Make LED Bulb E14 of Opple or equivalent model of Philips, Havels, CG
66GLS lamp / Candlelite classic lamp 40-60 watt classic Model/Make : P FR 240V E27 of make OSRAM or equaivalent model of Philips, Wipro, Havels,CG, Osram
67Supply of 10/15 Watt electric Aluminum/PVC LED Bulkhead Light fitting with IP 65-68 protection, suitable for 220/230V, 50 Hz, single phase AC Supply, complete as required. Make Havells/CG/Philips/Panasonic/Orient
68Sumo LED Driver 2 Watt to 4 Watt , 300 mA , model/Make C003C030V009FNM1T1 of Philips or equaivalent model of Havels, CG
69LED 20/25Watt round surface mounted plus Model/Make: 59018 of Philips or equivalent model of Havels, CG.
70Round LED Down Lighter (NW) 15 Watt , Model/Make: 59214/31/13 of Philips or equivalent model of Havels, CG,
71LED wall washer light (WW) 7 watt make/model: 34163/919215850131 of Philips or equivalent model of Havels/CG
72LED 22 to 25 Watt square surface mounted plus Model/Make: 59019 of Philips or equivalent model of Havels, CG.
73LED 15/18 Watt square surface mounted plus Model/Make: 59152/66/86 of Philips or equivalent model of Havels, CG.
74LED Batten of rating 10-15Watt, minimum lengh 2 feet, suitable for 220/230V, 50 Hz, single phase AC Supply, complete as required. Make Havells/CG/Philips.
75Rainproof LED Power supply, output voltage 12 Volts, 400watt, Input Supply Voltage 220/230 volts, 50Hz
76Water level controller with float sensors, 230/415Volts complete in all respect. Make : Minilec, Siemens or equivalent as required at site and approved.
77Exhaust Fan plastic body in round shape 150/200 mm sweep, High Speed, 220/230V, 50 Hz, single phase AC Supply, complete as required. Make: Ventilair DXW Celso model of Havells or equivalent model of USHA/CG
78Exhaust Fan Metal body heavy duty in required shape, Size - 10\\" - 12\\", Slow Speed, 230/250Volts, 50 HzMake - Havells/CG/Usha/Almonald
793 Module foot light with white LED- white color 230 Volts AC, Max Input current 24ma complete in all respect. Make : Legrand or equivalent as required at site and approved.
80Cover plate with support frame 3 Module white suitable for foot light complete in all respect. Make : Legrand or equivalent modal MK/Anchor
81Self adhesive PVC Electrical Insulation Tape Role of size 1.80cm x 6.5m x 0.125mm, ISI marked.
82Self adhesive Punture Tape minimum length - 10 Mtr Role for power cable repair.
83Rubber Real for ceiling fan of single phase, 220/230 volts.
84Ball bearing of number size from 6201 - 6205 nos.
85Metallic Fasteners 10/12 mm dia, 1.5/2 inch long, complete as required.
86HDPE Pipe of size 90mm dia, ISI marked.
87Thermoplastic Cable Junction Box IP 65 of size 146mm X 238mm X 111mm deep (nominal size), suitable for connecting of aluminium cables of size 16/25 sq.mm complete with terminals set of 4 Pole, metric knockouts for cable entry etc.,
88Supply of cubical type,outdoor type, Floor mounted, fixed type, dust proof Outdoor 300 Amp. Aluminium Bus Bar Fidder Pillar made out of M.S. CRC Sheet 14G duly red Oxide Primer with PO Red Paint as per specification. Approximate Size 1 Meter (H) X 1 Meter(W) X 300 mm(Deep) X 1.5 Meter long legs. Bus Bar size 300A TPN Aluminium Busbar (Horizontal) & Earth strip throughout the length of Panel Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Aluminium solid interconnection Busbar to to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Panel should be complete with all accessories like Gasket, Doorlocks, earthing stud etc. and should be as per Technical specification of CPRI guidelines. Panel should be Branded make fabricated from the approved panel fabricator.
89SUB HEAD-III: PETTY JOBS
90Charges for rewinding of ceiling fan size 1200/1400 mm sweep of USHA/ Kessle/ Khaitan/ CG make of different models complete in all respect up to working condition of CF with buy back of old material like copper wire etc.
91Charges for repair, and overhauling of single phase ½ HP rating mono block pump set complete in all including all material like bush/ capacitor/ bearing of etc. upto running condition of motor at site.
92Charges for rewinding of single phase ½ HP rating mono block pump set including repair of pump, shaft, seal bearing etc. and complete in all respect upto running condition of motor as required with buy back of old material like copper wire etc
93Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
94Providing and Laying of 6 SWG GI wire at 0.50 meter below ground level for conductor earth electrode, including soldering etc. as required.
95Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade upto 35 sq. mm. direct in ground including excavation, sand cushioning, protective convering and refilling the trench etc. as required.
96Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required.(i) Group A (Upto Type-III Residential Quarters)
97Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required.(ii) Group B (Type-IV and above Residential Qtrs.)
98Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
99Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
100Wiring for circuit/ submain wiring alongwith earth wire with the 2X2.5 sq mm + 1X2.5 sq mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note:- this item including PVC condute pipe + PVC wire)
101Wiring for circuit/ submain wiring alongwith earth wire with the 2X4 sq mm + 1X4 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note:- this item including PVC condute pipe + PVC wire)
102Wiring for circuit/ submain wiring alongwith earth wire with the 2X6 sq mm + 1X6 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note:- this item including PVC condute pipe + PVC wire)
103Providing and laying cement concrete 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stoneaggregate 20 mm nominal size) in muffs of Dia 15 inche and height 2 feet approx. for street light poles , including of Centering and shuttering including strutting, propping etc. and removal of form and 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) complete as directed by Engineer in charge. It also includes breaking of existing RCC muff and shifting of material from site as required.
104Charges for repair/overheauling/replacement of bearings including extra material like fledge/ gaskets, nut & bolts etc for 3-phase water booster pumps/motors of rating 3 HP to 5 HP, 415 volts including dismantling and Re-erection of the motor at site any one of make Crompton Greaves/ Kirlosker.
105Charges for Rewinding of 3-phase water booster pumps/motors of rating 3 HP to 5 HP, 415 volts including dismantling and Re-erection the motor at site including all material like fledge/ gaskets, nut & bolts etc any one of make Crompton Greaves/ Kirlosker with buy back of old material like copper wire etc.
106Charges for rewinding of Exhaust fan / Wall fan size 12”-18” (300mm-450mm sweep) complete in all respect up to working condition with buy back of old material like copper wire etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57062845
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 51.01 Lakhs
LAST DATE 27-08-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Annual Maintenance Contract Of Electrical Work For Colony Staff Quarters Including Street Lighting And Non-Residential Buildings At Csir-Csio, Sector-30,Chandigarh.
Basic Detail
Tender No CSIO/104/2026-27/Elect
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 18 Aug 2026
Submission Date 27 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 51.01 Lakhs
Tender Fee Ref. Documents
EMD 1.02 Lakhs
Exemption Not Available
Document List
b675b2f1-0407-422b-b251-b2a1a543f0e7.html
BOQ_335886.xls
Tendernotice_1.pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

b675b2f1-0407-422b-b251-b2a1a543f0e7.html

xls

BOQ_335886.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders