Science and Technology Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57062830

Tender For Civil And Electrical Rehabilitation & Repair Of 32 Quarters At The Scientist Apartments

Issued by Statutory Bodies & Commissions/Committees · Paschim Bardhaman, West Bengal
Tender Value
70.90 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
5 days left
EMD
1.41 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Paschim Bardhaman → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Civil And Electrical Rehabilitation & Repair Of 32 Quarters At The Scientist Apartments

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Aug-2026 Change of Unit in respect of Item no-76 in the BOQ Financial Bid 29-Aug-2026

BOQ

Name of Work:- Civil and electrical rehabilitation & repair of 32 quarters at the scientist apartments
Sl. No. Item Description
1ELETRICAL PARTWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit/casing, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required :
2Group A
3Wiring for circuit / sub main wiring alongwith earthwire with the following sizes of FRLS PVC insulated, copper conductor, single core cable in surface / recessed medium class PVC conduit/casing as required.
42 X 1.5 5sq. mm + 1 X 1.5 sq. mm earth wire
52 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
62 X 6 sq. mm + 1 X 6 sq. mm earth wire
7Supplying and fixing of following sizes of medium class PVC conduit/ Casing capping along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required
825 mm
9Supplying and fixing junction (metal) box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required
10150 mm X 75 mm X 60 mm deep
11Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
12Supplying and fixing PVC batten/ angle holder including connection etc. as required.
13Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
14Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
15Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
16Upto 35 sq. mm
17Above 35 sq. mm and upto 95 sq. mm
18Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
19Upto 35 sq. mm (clamped with 1mm thick saddle)
20Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
21Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
22Upto 35 sq. mm
23Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
243 X10 sq. mm (22mm)
253.5 X 35 sq. mm (32mm)
263.5 X 70 sq. mm (38mm)
27Supplying and fixing following piano type switch/ socket on the existing switch box connections etc. as required
285/6 amps switch
292 way 5/6 A switch
303 pin 5/6 A socket outlet
31Supplying and fixing deluxe type electronic fan regulator with all accessories on the existing bakelite/polycarbonate board with proprly grooved including necessary electrical connection as required.Make: Anchor/Pritam or equivalent
32SITC of 3 mm thick phenolic laminated Bakelite board (200 mm X 125 mm) with proprly grooved for attaching switches/sokets with all accessories on existing box as per direction of Engineer-in-Charge
33SITC of 3 mm thick phenolic laminated Bakelite board (100 mm X 100 mm) with proprly grooved for attaching switches/sokets with all accessories on existing box as per direction of Engineer-in-Charge
34Supplying and fixing 40A, Double Pole, 415V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
35Supplying and fixing in position DP sheet steel enclosure on existing panel along with 40 A 415 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. The job inclusive of dismainteling of old unserviceable SFU as per instruction of E/C.
36Supplying and fixing of PVC housing 10 Watt LED Bulkhead (CCT: 5500-6500K, Luminous Efficacy : 100 Lumen/Watt or higher) with IP65 protection and IK08 impact resistance suitable for surface and wall mounting applications.. Make: WT090W LED10S PSU PC of Philips or equivalent from Crompton/BajajWarranty: Comprehensive 02 (Two) years from OEM
37Supply and fixing of 1200 mm sweep, 230 Volt, Metallic Ivory colour, full copper motor and aluminium blades Ceiling mounted fan with safety wire, suitable suspension rod, nut-bolt, with connection alongwith 3x1.5 sq.mm FRLS PVC insulated copper conductor single core wire, testing, commissioning etc as required. job inclusive of dismentling of unserviceable ceiling fan.Make: GRATIA of Orient or equivalent from Khaitan/CG)Warranty: Comprehensive 02 (Two) years from OEM
38Supply and Fixing of 45 watts, High performance street light luminaire (CCT: 5500-6500°K, Efficacy: Minimum120 Lumen/ watt or higher) with SPD, IP66 protection, PDC housing with and street light optics to ensure uniform distribution (IK08). The luminaire family comes with dedicated street optics fixing dia 32-40 mm for fixing/mounting in existing roof perapit wall with supply of L shape new GI pipe, connection, testing, commissioning as required. Make: BRP331 LED54 CW R5N PC PSU S1 V1 of Philips or equivalent from Crompton/BajajWarranty: Comprehensive 02 (Two) years from OEM for luminire including driver.
39Dismantling of all the unserviceable old wiring, cable, conduit, DB, switch box, JB, light, fan etc as required for 32 qtr and surrounding common space area. The job inclusive of refixing the serviceable electrical materials as per direction of Engg.- in Charge.
40Supply of XLPE insulated, core laid up, thermoplastic tape inner sheathed, armoured and extruded PVC type ST2 outer sheathed, strended aluminium conductor 1.1 KV grade power cables, conforming to IS 7098 ( Part - 1) 2011,and ISI marked of following sizes.Make- Gloster/Polycab/ Havells/eqv
413 Core 10 sq mm A2XWY/A2XFY cable.
424 Core 16 sq mm A2XWY/A2XFY cable.
433½ Core 70 sq mm A2XWY/A2XFY cable.
44SITC of XLPE insulated, core laid up, thermoplastic tape inner sheathed, un-armoured and extruded PVC type ST2 outer sheathed, strended Copper conductor 1.1 KV grade power cables, conforming to IS 7098 (Part - 1) 2011,and ISI marked of following sizes with both side termination with brass Compression gland and Copper lugs.Make- Gloster/Polycab/ Havells/equivalent
4516 sq mm 2XY cable.(1 meter cable with both side End termination-32 nos)
4625 sq mm 2XY cable.(1 meter cable with both side End termination-16 nos)
47SITC of 1 nos 15A Piano type switch and 1 no 15A Socket combined as a single unit on existing boxes as per instruction of E/C.
48Supply and fixing in position of 16KA,125A FP, MCCB with thermal magnetic pritection unit. The MCCB should be operated with supply and fixing of rotary type handle, both side speeder link for termination alongwith supply & installation of DPX3 160 MCCB enclosures on existing LT panel as a main including necessary connections testing and commissioning etc. as required. This job is inclusive dismentaling of old unserviceable SFU /Main switch as per instruction of E/CMake: Legrand Model - 4200 16 (MCCB) and 5078 02 (enclosure)/eqv.)Warranty: Comprehensive 02 (Two) years from OEM
49Supply and fixing in position of 10-60A, Class-1 base mounting Single Phase kWh meter with LCD display. The meter should be fixing on existing LT panel including necessary connections testing and commissioning etc. as required. This job is inclusive dismentaling of old unserviceable meter as per instruction of E/C.Make: WM101BC7DL0 of L&T/eqivalentWarranty: Comprehensive 02 (Two) years from OEM
50Servicing, scrapping, sand papering and preparing the surface smooth including necessary repairs, Two or more coats painting along with one coat primer and along with Supply and fixing of front MS cover of busbur, nut bolt, necessary connection of incomer and out going feeders with suitable size cable/busber for full functioning of LT panel etc. as required as per instruction of E/C.
51Supply and Fixing of mounting rail for LED tubelight with batten along with LED Lamp 20 W (CCT: 5500-6500°K, Efficacy: Minimum120 Lumen/ watt or higher), Clamp, nut bolts and all accessories for fixing wall mounting, connection, testing, commissioning etc as required Make: TMC 502 1xT- LED 22W and Essential LED Tube 1200mm 20W865 T8 IND Iof Philips or equivalent from Crompton/Bajaj)Warranty: Comprehensive 02 (Two) years from OEM for luminire including driver.
52Supply and Fixing of LED Down light (Round)12 Watt (CCT: 5500-6500°K, Efficacy: Minimum100 Lumen/ watt or higher) with all accessories on wall with necessary connection, testing, commissioning etc as required.Make: SM250/260 LED12S 6500 PSU WH of Philips or equivalent from Crompton/Bajaj)Warranty: Comprehensive 02 (Two) years from OEM for luminire including driver.
53Supply and Fixing of 10W, Warm White, IP-44, 1000 lumen in built LED Bathroom Wall Light for Mirror light application, including Clamp, nut bolts and all accessories for fixing ceiling mounting, connection, testing, commissioning etc as required (Philips or equivalent.)Make: 919215851242 of Philips or equivalent from Crompton/Bajaj.Warranty: Comprehensive 02 (Two) years from OEM for luminire including driver.
54CIVIL PARTChipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge-50 mm average thickness.
55Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.-Bars upto 12 mm diameter
56Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
57Providing and laying SBR Polymer modified (of approved make @ minimum 2% by wt. of cement used) plain/reinforced concrete jacket for the structural members e.g. columns, pillars, piers, beams etc with concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] with specified average thickness all-round existing core of RCC member. -50 mm thick in Grade M25 with cement content not less than 330 kg per cum.Note: Rates shall be for finished surface area of concrete and shall include the cost of making holes in existing RCC slab, if required, for pouring concrete in shuttering mould of jacket and appropriate approved Super-Plasticiser for rendering concrete as flowable self compacting and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument)
58Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within Institute campus as per direction of Engineer - in- charge.
59Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
60Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
61Centering & shuttering including strutting, propping etc & removal of form for lintels, beams, cantilevers etc.
62Centering & shuttering including strutting, propping etc & removal of form for suspended floor, roofs, landings, balconies, and access platform.
63Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more..
64Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
6515mm cement plaster on rough side of mix 1:4 (1cement: 4coarse sand)
66Demolishing brickwork manually/ by mechanical means including stacking of serviceable materials and disposal of unserviceable materials within Institute campus in cement mortar.
67Brick work with FPS bricks of class designation 75 upto plinth level in 1:6 grade (1 cement: 6 coarse sand).
68Taking out doors, windows and clereystorey window shutters (steel or wood) including stacking within Institute campus as per direction of Engineer - in - charge: Of area 3 sq. metres and below
69Providing and fixing ISI marked flush door shutters 30 mm thick including ISI marked Stainless Steel butt hinges, necessary screws conforming to IS :2202 (Part I) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
70Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials (within within Institute campus as per direction of Engineer - in - charge) as per direction of engineer in charge.
71Providing and fixing PVC low level flushing cistern with manually controlled device (handle lever) conforming IS :7231 with all fittings and fixtures complete.: 10 ltrs capacity -white.
72Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in charge.-Long pattern W.C Pan of size 580x440 mm
73Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:-White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
74Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall -15 mm nominal dia Pipes
75Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes
76Providing and fixing brass bib-cock of approved quality: 15 mm nominal bore
77Providing and fixing brass stop cock of approved quality 15 mm nominal bore.
78Providing and fixing PVC flexible waste pipe for sink and wash basin : 32 mm dia
79Providing and fixing 100 mm sand cast iron grating for gully, floor or Nahani trap.
80Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
81Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre :Upto 16m height. (No separate payment shall be made for scaffolding).
82Wall painting with acrylic emulsion paint of Royale Luxury emulsion paint of Asian Paints/ Silk Luxury emulsion of Berger or equivalent product of approved brand and manufacture to give an even shade. Two or more coats on new work. Upto 16m height. (No separate payment shall be made for scaffolding).
83Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
84Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work
85Providing and fixing ISI marked oxidised M.S. handles conforming to 1S:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378)-125 mm
86Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
87Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter.
88Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 100X58X1.90 mm
89Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) of size 200x10 mm
90Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) of size 100x10 mm
91Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm
92Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378)- 300x16 mm
93Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
94Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
95Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge.The cleaning shall consist following operations:- (i) Tank shall beemptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
96Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
97Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
98Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
99Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 and lift up to 1.5 m. All kinds of soil
100Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
101Repairing of the cistern by providing of syphon/washer/internal ballcock/flush pipe/handle, which ever is needed to make the cistern complete working condition.
102Providing and fixing six levers Godrej / Link door lock, Kadi Tala-275mm Pack of 1 key lock with 3 keys for double door-steel finish brown in colour or equivalent.
103Cleaning the roofs of building and sheds, G.I / A.C gutter etc including removing dry leaves, green growth, uprooting plants, etc. mending the damages and removing the debris to a safe distance as directed. (Roof area will be consider for payment) .
104Dismantling wash basin with brackets with or without waste fittings.
105Rewashering stop cock/bib cock/push cock/pillar cock including gland packing if necessary (15mm).
106Cleaning and removing conservancy garbage mixed with rubbish & other filthy materials from the road side flank, drain and compound including sutting, loading, unloading to and from truck or cart by Mathor labour & removing the same to any distance.
107Cleaning I.P.W.C. with acid.
108Cleaning glazed tiles/mosaic/channels with acid.
109Removing chokage of G.I., CPVC, H.C.I. or S.W. pipe of any dia ( Underground ) with split bamboo or any other suitable method as directed.
110Removing chokage of G.I., CPVC, H.C.I. or S.W. Of any dia ( overground ) with split bamboo or any other suitable method as directed.
111Uprooting and removing plants from the surface of walls parapet etc and making good damages. Repairing of damages to be paid separately. a) Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr.
112Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987: 4mm thick clear glass as per instruction of Engineer-in Charge.
113Supplying, fitting & fixing 100 mm dia. (internal) Cast iron soil pipe only conforming to I.S. 3989 / 1970 and I.S. 1729/1964, With lead caulked joints with bobbins, nails etc. with lead caulked joints including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the center line of the total pipe line in fitted condition including specials,payment for specials & Painting will however be paid seperately).
114Supplying,fitting and fixing cast iron 100 mm dia 'P' trap conformimg to I.S. 3989 /1970 and 1729 / 1964 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately).
115Easing door and windows.
116Supplying, fitting and fixing Waste fittings of 32 mm for basin/sink complete.
117Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts) , reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 73 will be made once only).
118Styles and rails of wooden shutters fitted and fixed complete. (Payment to be made on area of new work only)-For 25mm. Thick shutter of Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
119Panel (made of single plank) of door and window shutters to design as directed:(Payment to be made on area of exposed new work). (In case of non-supply of single plank penal rate of reduction to a maximum of 30% will be made).-19mm thick panel of 30cm to 45cm width- of Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
120Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. (In case of non-supply of single plank, penal rate of reduction of 20% will be made)-35mm thick shutters with 19mm thick panel of size 30 to 45 cm. of Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak
121Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.- (iii) 600 mm long
122Supplying, fitting and fixing glass shelf with aluminium guard rails.(a) Ordinary type with 5.5 mm sheet glass 450 mm X 125 mm
123Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (i) 530 mm X 430 mm x 180 mm
124Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge: 6mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57062830
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 70.90 Lakhs
LAST DATE 29-08-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Civil And Electrical Rehabilitation & Repair Of 32 Quarters At The Scientist Apartments
Basic Detail
Tender No 11/420/26-27/Composite (Col)/Capital/ESD
Bidding Type Tender
Location
City Paschim Bardhaman
State West Bengal
Key Dates
Publish Date 20 Aug 2026
Submission Date 29 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value 70.90 Lakhs
Tender Fee Ref. Documents
EMD 1.41 Lakhs
Exemption Not Available
Document List
7ad22f9d-0e0a-4bdc-b639-7080f7f0c64f.html
BOQ_335761.xls
GCCscientistapartment.pdf
ScopeandMakeScientistapartment.pdf
TenderAcceptenceUndertaki_1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

7ad22f9d-0e0a-4bdc-b639-7080f7f0c64f.html

xls

BOQ_335761.xls

pdf

GCCscientistapartment.pdf

pdf

ScopeandMakeScientistapartment.pdf

pdf

TenderAcceptenceUndertaki_1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders