Tender For Providing Air Conditioning System Including Power Connection And Necessary Electrical Work For The Newly Constructed Auditorium Building At Dumurjola Stadium Under Wbhidco.
Tender Value
8.65 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
3 days left
EMD
17315
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Howrah → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Air Conditioning System Including Power Connection And Necessary Electrical Work For The Newly Constructed Auditorium Building At Dumurjola Stadium Under Wbhidco.
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Cooling Only Top Discharge Modular VRF ODU running on full inverter twin rotary compressor having R410a refrigerant and EER not less than 4.5, Unit should have 6 stageintelligent oil control, inspect proof control box.8 HP Outdoor (for 2nd and 3rd) (Make-LG/Trane/Mitsubishi Heavy) |
| 2 | Supply of Hi-Wall Type VRF Indoor Unit along with Wireless Controller. a) 1.6 TR Hi-Wall. (Make-LG/Trane/Mitsubishi Heavy) |
| 3 | b) 2.0 TR Hi-Wall. (Make-LG/Trane/Mitsubishi Heavy) |
| 4 | Supply, Installation, Testing and Commissioning of Refrigerant piping, Insulation, Drain Piping, Cabling, Lifting and Shifting, Pressure Testing, Gas Charging. |
| 5 | Supply and Delivery 1.1 Kv grade XLPE insulated Copper flexible cable of the following size. i) 4 core x 10.00 sq.mm(Make- KEI/Mescab/Gloster) |
| 6 | Supply and Delivery 1.1 Kv grade XLPE insulated Copper flexible cable of the following size. ii) 4 core x 6.00 sq.mm(Make- KEI/Mescab/Gloster) |
| 7 | Supply and Delivery 1.1 Kv grade XLPE insulated Copper flexible cable of the following size. iii) 3 core x 4.00 sq.mm(Make- KEI/Mescab/Gloster) |
| 8 | Laying of cable as below, floor/ pavement /wall/ and making holes incl.,Sadel with necessary accessaries below and mending good the damages to original finish incl. removing the rubbish i) 4 core x 10.00 sq.mm=60 mtr. ii) 4 core x 6.00 sq.mm=40 mtr. iii) 3 core x 4.00 sq.mm=30 mtr. |
| 9 | Supply & Fixing of 4 module IP65 box with necessary fixing accessaries as required. (Make-Legrand/L&T/ABB) |
| 10 | Supply & Fixing of 415V,50Hz,40Amp,4 pole MCB with necessary accessaries as required. (Make-Legrand/L&T/ABB) |
| 11 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-Mescab/Gloster/KEI) incl. necy. fittings as required. i) 2 x 4.00 sq.mm + 1 x 2.50 sq.mm |
| 12 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-Mescab/Gloster/KEI) incl. necy. fittings as required. ii) 2 x 2.50 sq.mm + 1 x 1.50 sq.mm |
| 13 | S/F 240V 1 No. 16A. 5 pin Modular type plug socket with 1 no 16A modular type switch without top on 3 modular GI modular type switch board incl. metal box with top cover plate flushed in wall incl. making connection as per GS.(Make –Legrand/Anchor/Cabtree) |
| 14 | S/F 240V 1 no. 25A modular type Starter,1 no. 25A MCB with 1 module plant plate without top on 4 modular GI modular type switch board incl. metal box with top cover plate flushed in wall incl. making connection as per GS. (Make –Legrand/Anchor/Cabtree) |
| 15 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buriedinside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.No. 6 SWG |
| 16 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below.By ISI-Medium GI pipe |
| 17 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. 4 Core x 10 sq.mm. |
| 18 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.i) 10.00 sq.mm |
| 19 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.ii) 6.00 sq.mm |
| 20 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.iii) 4.00 sq.mm |
| 21 | Add GST @18% and Cess @1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender