Tender For Providing Flood Lighting For Athletic Track At Sports Complex, Sector-7, Chandigarh.
Tender Value
6.85 Crore
Estimated cost
Bid Submission
01 Sep 2026
10 days left
EMD
13.71 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Flood Lighting For Athletic Track At Sports Complex, Sector-7, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | Design, supply, installation, testing and commissioning of High Power LED Sports Light Luminaires with non-integral drivers of suitable wattage, complete with the following specifications.,(As per Complete Item No. 1 of the DNIT). |
| 2 | SITC of High Mast Pole with Head FrameThe firm shall carry out the complete design, supply, installation, testing and commissioning of the High Mast System in accordance with the following design parameters and the requirements of the Department.,(As per Complete Item No. 2 of the DNIT). |
| 3 | Supply, Fabrication, Erection, Testing and Commissioning of Double Door Feeder Pillar Panel, outdoor type, minimum IP54 conforming to IEC 60529/IS 12063, suitable for 415 V, 3-Phase, 4-Wire, 50 Hz AC supply system, complete with RCC foundation, cable termination and all associated accessories.,(As per Complete Item No. 3 of the DNIT). |
| 4 | FOUNDATION FOR 35 MTR. LONG HIGH MAST: Design and casting of suitable raft-type foundation for the High Mast complete with all civil works, as per the specifications under S. No. 1 above. The foundation shall be designed based on the Safe Bearing Capacity (SBC) of the soil as per the soil investigation report. (As per Complete Item No. 4 of the DNIT). |
| 5 | All kinds of soil (Size 6.2m x 6.2m x 3.3m= 126.85 cum) (4 nos. x 126.85= 507.40 cum) |
| 6 | DSR Item No. 4.1.11 (Civil Work)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 7 | 1:5:10 (1 cement: 5 fine sand derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources) Size: 6.2m x 6.2m x 0.10m =3.84 cum.(4 nos. x 3.84= 15.37 cum) |
| 8 | DSR Item No. 5.22.6 (Civil Work) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 9 | DSR Item No. 5.2.2 (Civil Work) Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 10 | 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)Size 6.0 x 6.0 x 0.6 = 21.60 cumSize 3.9 x 3.9 x 0.5 = 07.60 cumSize 1.8 x 1.8 x 1.9 = 06.15 cumTotal (21.60 + 7.60 + 6.15 = 35.35 cum.)(4 Nos. x 35.35 = 141.40 cum) |
| 11 | DSR Item No. 5.9.1 (Civil Work) Centering and shuttering including strutting, propping etc. and removal of form for: |
| 12 | Foundations, footings, bases of columns, etc. for mass ConcreteSize: 2 × (6.0 + 6.0) × 0.60 = 4.40 sq. mSize: 2 × (3.9 + 3.9) × 0.50 = 7.80 sq. mSize: 2 × (1.8 + 1.8) × 1.90 = 13.68 sq. mTotal: (14.40 + 7.80 + 13.68= 35.88 sq. m) (4 Nos. × 35.88 = 143.52 sq. m) |
| 13 | DSR item No.15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 14 | 160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 15 | DSR item No.5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 16 | DSR item No.15.15Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 17 | 160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 18 | DSR item No.5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 19 | Supply and laying of 1.1 kV grade XLPE insulated, PVC sheathed, aluminium conductor cable conforming to IS 7098 (Part-I) (latest revision | amendments), of the following sizes, to be laid in the existing RCC | Hume | DWC | Metal pipe as required at site. The item includes the cost of cable laying, testing, commissioning, (As per Complete Item No. 9 of the DNIT). |
| 20 | Size 240 Sq.mm 3.5 Core |
| 21 | Supply, Erection, Testing and Commissioning of an external Man Riding Unit for providing access to the head frame of the high mast. The Man Riding Unit shall have a minimum safe load carrying capacity of 300 kg and a climbing speed not exceeding 9 m/min. (As per Complete Item No. 10 of the DNIT). |
| 22 | Labour charges for horizontal boring by mechanical means (hydraulic excavator)/ manual means 1 Meter below the ground level for laying of DWC Pipe including cost of 2 nos. Pit digging and refilling, (As per Complete Item No. 11 of the DNIT). |
| 23 | MAIN L.T. PANEL Supplying, installation, testing and commissioning of modular, sectionalized Low Voltage (LV) Panel of Form–4B construction, suitable for 415 V, 3 Phase, 4 Wire, 50 Hz AC supply system, conforming to IEC 61439-1 and IEC 61439-2, as a Totally Type Tested Assembly/ Design Verified Assembly, fabricated in a compartmentalized design., (As per Complete Item No. 12 of the DNIT). |
| 24 | 01 No. LT Panel of approximate size 2400 mm × 1650 mm. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender