Power Boards / Undertakings / PSU Closing in 22 days TDR #57060852

Tender for Supply of Auxiliary Contactors, Timers and MCBs for 18Nos Compressors of BOP area

Issued by Boards / Undertakings / PSU · , Telangana
Tender Value
39302
Estimated cost
Bid Submission
15 Sep 2026
22 days left
EMD
0
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Telangana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Auxiliary Contactors, Timers And Mcbs For 18Nos Compressors Of BOP Area , TIMER MODEL:2ANDTO,PRODUCT CATEGORY:TIMER SWITCHES VOLTAGE:24 - 240 V AC/DC, Control Circuit Voltage 240 V AC 50/60 Hz TOLERANCE:-20% To +10% Duty Type:Continuous Duty(S1) Contact:5A 240VAC/28V DC Timer(Ts):0.1S-10H TMOUNTING TYPE:ON SYMMETRIC RAIL EN/IEC 60715 OR DIN 35 RAIL,CERTIFICATION :CE, ROHS Suitable To Lauritz Knudsen GIC Make Timer , AIR BREAK(POWER)CONTACTORPOWER , CURRENT Rating:20A VOLTAGE Rating:415V AC AUXILIARY CONTACT ARRANGEMENT:1NC Duty Type:Continuous Duty(S1) Control Circuit Voltage 240 V AC 50/60 Hz Suitable To SIEMENS MODEL:3TF30 01-0A, Operational Currents: Ie/AC3:9A, Ie/AC1:20A , Air Break(Aux) CONTACTOR: POWER AUX CONTACTS:2NO+2NC Duty Type:Continuous Duty(S1) Suitable To Siemens Model: 3TH3022-0AB0 SYSTEM VOLTAGE Rating:550VAC,50HZ Control Circuit Voltage 240 V AC 50/60 Hz Operational Current Rating Ie/AC15:10A , CONTACTOR,Suitable To Schneider MODEL CODE:LC1D12B7,1NO+1NC,24V DC 1.Oerational Current 25 A (At 140 Deg F (60 Deg C)) For Power Circuit 2. Rated Insulation Voltage Power Circuit 690 V IEC 60947-4-1 3. Rated Impulse Withstand Voltage 6 Kv IEC 60947 4. Auxiliary Contacts Type Mechanically Linked 1 NO + 1 NC 5. Control Circuit Voltage 24 V AC 50/60 Hz 6. Duty Type:Continuous Duty(S1) , CONTACTOR,Suitable To ABB MODEL CODE:NL22E, Auxiliary Contacts Type : 2NO+2NC,24V DC Rated Insulation Voltage Power Circuit: 690 V, Operational Current:16 A, . Control Circuit Voltage:24 V DC Duty Type:Continuous Duty(S1) , Industrial Operation Standard MCB, 230V AC/24V DC, 6A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 230V AC, 10A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 230V AC, 16A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 24V DC, 10A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 24V DC, 6A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 24V DC, 2A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 24V DC, 4A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens

BOQ

Sl. No. Item Name
1TIMER MODEL:2ANDTO,PRODUCT CATEGORY:TIMER SWITCHES VOLTAGE:24 - 240 V AC/DC, Control Circuit Voltage 240 V AC 50/60 Hz TOLERANCE:-20% to +10% Duty Type:Continuous Duty(S1) Contact:5A 240VAC/28V DC Timer(Ts):0.1s-10h TMOUNTING TYPE:ON SYMMETRIC RAIL EN/IEC 60715 OR DIN 35 RAIL,CERTIFICATION :CE, ROHS Suitable to Lauritz Knudsen GIC Make Timer
2AIR BREAK(POWER)CONTACTORPOWER , CURRENT Rating:20A VOLTAGE Rating:415V AC AUXILIARY CONTACT ARRANGEMENT:1NC Duty Type:Continuous Duty(S1) Control Circuit Voltage 240 V AC 50/60 Hz Suitable to SIEMENS MODEL:3TF30 01-0A, Operational Currents: Ie/AC3:9A, Ie/AC1:20A
3Air Break(Aux) CONTACTOR: POWER AUX CONTACTS:2NO+2NC Duty Type:Continuous Duty(S1) Suitable to Siemens Model: 3TH3022-0AB0 SYSTEM VOLTAGE Rating:550VAC,50HZ Control Circuit Voltage 240 V AC 50/60 Hz Operational Current Rating Ie/AC15:10A
4CONTACTOR,Suitable to Schneider MODEL CODE:LC1D12B7,1NO+1NC,24V DC1.Oerational current 25 A (at 140 Deg F (60 Deg C)) for power circuit2. Rated insulation voltage Power circuit 690 V IEC 60947-4-13. rated impulse withstand voltage 6 kV IEC 609474. Auxiliary contacts type Mechanically linked 1 NO + 1 NC5. control circuit voltage 24 V AC 50/60 Hz6. Duty Type:Continuous Duty(S1)
5CONTACTOR,Suitable to ABB MODEL CODE:NL22E,Auxiliary contacts type : 2NO+2NC,24VDC Rated insulation voltage Power circuit: 690 V,Operational current:16 A, .control circuit voltage:24 V DCDuty Type:Continuous Duty(S1)
6Industrial operation standard MCB, 230V AC/24V DC, 6A Double Pole Suitable to make: Schneider Electric/ABB/Siemens
7Industrial operation standard MCB, 230V AC, 10A Double Pole Suitable to make: Schneider Electric/ABB/Siemens
8Industrial operation standard MCB, 230V AC, 16A Double Pole Suitable to make: Schneider Electric/ABB/Siemens
9Industrial operation standard MCB, 24V DC, 10A Double Pole Suitable to make: Schneider Electric/ABB/Siemens
10Industrial operation standard MCB, 24V DC, 6A Double Pole Suitable to make: Schneider Electric/ABB/Siemens
11Industrial operation standard MCB, 24V DC, 2A Double Pole Suitable to make: Schneider Electric/ABB/Siemens
12Industrial operation standard MCB, 24V DC, 4A Double Pole Suitable to make: Schneider Electric/ABB/Siemens

AI Tender Summary

OUR REF NO 57060852
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 39302
LAST DATE 15-09-2026
Authority
Authority Name Telangana Power Generation Corporation Limited
Work Description Supply Of Auxiliary Contactors, Timers And Mcbs For 18Nos Compressors Of BOP Area , TIMER MODEL:2ANDTO,PRODUCT CATEGORY:TIMER SWITCHES VOLTAGE:24 - 240 V AC/DC, Control Circuit Voltage 240 V AC 50/60 Hz TOLERANCE:-20% To +10% Duty Type:Continuous Duty(S1) Contact:5A 240VAC/28V DC Timer(Ts):0.1S-10H TMOUNTING TYPE:ON SYMMETRIC RAIL EN/IEC 60715 OR DIN 35 RAIL,CERTIFICATION :CE, ROHS Suitable To Lauritz Knudsen GIC Make Timer , AIR BREAK(POWER)CONTACTORPOWER , CURRENT Rating:20A VOLTAGE Rating:415V AC AUXILIARY CONTACT ARRANGEMENT:1NC Duty Type:Continuous Duty(S1) Control Circuit Voltage 240 V AC 50/60 Hz Suitable To SIEMENS MODEL:3TF30 01-0A, Operational Currents: Ie/AC3:9A, Ie/AC1:20A , Air Break(Aux) CONTACTOR: POWER AUX CONTACTS:2NO+2NC Duty Type:Continuous Duty(S1) Suitable To Siemens Model: 3TH3022-0AB0 SYSTEM VOLTAGE Rating:550VAC,50HZ Control Circuit Voltage 240 V AC 50/60 Hz Operational Current Rating Ie/AC15:10A , CONTACTOR,Suitable To Schneider MODEL CODE:LC1D12B7,1NO+1NC,24V DC 1.Oerational Current 25 A (At 140 Deg F (60 Deg C)) For Power Circuit 2. Rated Insulation Voltage Power Circuit 690 V IEC 60947-4-1 3. Rated Impulse Withstand Voltage 6 Kv IEC 60947 4. Auxiliary Contacts Type Mechanically Linked 1 NO + 1 NC 5. Control Circuit Voltage 24 V AC 50/60 Hz 6. Duty Type:Continuous Duty(S1) , CONTACTOR,Suitable To ABB MODEL CODE:NL22E, Auxiliary Contacts Type : 2NO+2NC,24V DC Rated Insulation Voltage Power Circuit: 690 V, Operational Current:16 A, . Control Circuit Voltage:24 V DC Duty Type:Continuous Duty(S1) , Industrial Operation Standard MCB, 230V AC/24V DC, 6A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 230V AC, 10A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 230V AC, 16A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 24V DC, 10A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 24V DC, 6A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 24V DC, 2A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens , Industrial Operation Standard MCB, 24V DC, 4A Double Pole Suitable To Make: Schneider Electric/ABB/Siemens
Basic Detail
Tender No 202/2026-27/CE/O&M/KTPP/C&I-II/ Supply of Auxiliary Contactors, Timers and MCBs for 18Nos Compressors of BOP area
Bidding Type Tender
Location
City
State Telangana
Key Dates
Publish Date 17 Aug 2026
Submission Date 15 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 39302
Tender Fee Ref. Documents
EMD 0
Exemption Not Available
Document List
b4cefbfd-a1a9-4260-846d-cd2650d33cc7.html
DocumentsList.zip
download.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

b4cefbfd-a1a9-4260-846d-cd2650d33cc7.html

zip

DocumentsList.zip

xls

download.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders