Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - Annual Maintenance Contract Of Local Area Network At Npcil Hq For 3 Years; Lan System; Annual Maintenance Contract (Amc); Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - Supp
Tender Overview
Project Description
Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - Annual Maintenance Contract Of Local Area Network At Npcil Hq For 3 Years; Lan System; Annual Maintenance Contract (Amc); Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - Supply Installation Of Various Networking Items; Lan System; Annual Maintenance Contract (Amc); Monthly; Yes , Customized Amc/Cmc For Pre-Owned Products - License Renewal; Lan System; Annual Maintenance Contract (Amc); As Per Tender Condition; Yes - Arista 7050X3 , Juniper Ex3400-24T-Taa , Juniper Qfx5120-48Ym-Afo-T , Juniper Ex4400-24T-Taa , Brocade Icx6430 , Single Mode / Multimode Sc/Lc/St Pigtail As Per Instruction , 24 Core Indoor / Outdoor Fiber Optic Liu / Joint Enclosure Fully Loaded. Type Of Adaptor Shall Be Provided At The Time Of Supply. , 12 Core Indoor / Outdoor Fiber Optic Liu / Joint Enclosure Fully Loaded. Type Of Adaptor Shall Be Provided At The Time Of Supply. , Sm/Mm Duplex Fibre Optic Patch Chord(Length Upto 10Mtrs.) Type Of Adaptor Shall Be Provided At The Time Of Supply. , Sm/Mm Duplex Fibre Optic Patch Chord(Length Upto 3Mtrs.) Type Of Adaptor Shall Be Provided At The Time Of Supply. , Cat 6 Copper Lan Cable (1 Box=305 Meter) , Media Convertor (1 Set = 02 Mcs)(Shall Have Min. 01 Nos. Single Core Connector Sm/Mm Fiber Ports, Min. 01Nos. 10/100/1000Basetx Rj45 Ports) Type Of Fiber & Connector Shall Be Informed At The Time Of Supply Instruction As Per Requirement. Both End Fiber Patch Cords In Contractor Scope. , 12Way Adaptor Plate With Adaptors For Liu (Supply & Installation) , Mux-Demuxnos. Of Channels: Min.04, Both End Sfps To Be Supplied: Yes, Speed Of Sfps:1G, Type Of Fiber: Smpatch Cords: To Be Provided By Contractor, Sfp Compatibility: Juniper / Brocade Etc. As Per Actual Switch Installed At Site. Installation & Commissioning: Contractor Scope, Switch Configuration: Contractor Scope.Note: Npcil Will Provide The Switches Only. Link Length To Be Considered As 20Kms. Contractor Shall Be Responsible For Supply Installation, Commissioning And Providing 04 Nos. Of Links Between Identified Locations.Any Other Required Material Like Patch Cords Etc. (Other Than Switch) Shall Be In Scope Of The Contractor , Fibre Optic Power Meter , Rj45 Connector For Cat6/Cat6a , Cat 6/6A Information Outlet , 1G Lr (20Kms) Bidi/Duplex Sfp Modules For Juniper/Brocade/Cisco/Dlink/Any Other Make Switches , 3Core4sqmm Copper Cable For Datacentre Power Connection , Hv 32A 2P+E Ac Box With Hv 32A Dp Mcb , 240Vac, 2P 25A Mcb , Supply, Installation & Cable Dressing Of 30*50*50Mm(Approx) Metal Cable Channel In Various Meeting Rooms Floor By Groove Cutting Or By Screwing , Rj45 Pvc Port Lock & Dust Blocker With Key , Fiber (Ofc) Cable Core Splicing (Mm / Sm) , Otdr Of Fibre Optic Cable Core For Fault Identification (Per Core) , Installation Of Wall Rack Unit (Consumables Like Anchor Fastner Etc. In Contractor Scope) , Laying Of Fiber (Ofc) Cable (Indoor / Outdoor) , Removal Of Wall Rack Unit And Shifting Of Same To Npcil Stores At Nub/Vsb/Tvs. , Renewal Of Licenses And 03 Year Warranty Of Fortigate-60E , Renewal Of Licenses And 03 Year Warranty Of Check Point 750
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Arista 7050X3 | Arista 7050X3 |
| 2 | Juniper EX3400-24T-TAA | Juniper EX3400-24T-TAA |
| 3 | Juniper QFX5120-48YM-AFO-T | Juniper QFX5120-48YM-AFO-T |
| 4 | Juniper EX4400-24T-TAA | Juniper EX4400-24T-TAA |
| 5 | Brocade ICX6430 | Brocade ICX6430 |
| 6 | Single Mode / Multimode SC/LC/ST Pigtail as per instruction | Single Mode / Multimode SC/LC/ST Pigtail as per instruction |
| 7 | 24 core indoor / outdoor Fiber optic LIU / joint enclosure fully loaded. Type of adaptor shall be provided at the time of supply. | 24 core indoor / outdoor Fiber optic LIU / joint enclosure fully loaded. Type of adaptor shall be provided at the time of supply. |
| 8 | 12 core indoor / outdoor Fiber optic LIU / joint enclosure fully loaded. Type of adaptor shall be provided at the time of supply. | 12 core indoor / outdoor Fiber optic LIU / joint enclosure fully loaded. Type of adaptor shall be provided at the time of supply. |
| 9 | SM/MM Duplex Fibre Optic Patch Chord(Length upto 10Mtrs.) Type of adaptor shall be provided at the time of supply. | SM/MM Duplex Fibre Optic Patch Chord(Length upto 10Mtrs.) Type of adaptor shall be provided at the time of supply. |
| 10 | SM/MM Duplex Fibre Optic Patch Chord(Length upto 3Mtrs.) Type of adaptor shall be provided at the time of supply. | SM/MM Duplex Fibre Optic Patch Chord(Length upto 3Mtrs.) Type of adaptor shall be provided at the time of supply. |
| 11 | Cat 6 Copper LAN Cable (1 Box=305 meter) | Cat 6 Copper LAN Cable (1 Box=305 meter) |
| 12 | Media Convertor (1 Set = 02 MCs)(Shall have min. 01 nos. single core connector SM/MM fiber ports, min. 01nos. 10/100/1000BaseTX RJ45 ports) Type of fiber & connector shall be informed at the time of supply instruction as per requirement. Both end fiber patch cords in contractor scope. | Media Convertor (1 Set = 02 MCs)(Shall have min. 01 nos. single core connector SM/MM fiber ports, min. 01nos. 10/100/1000BaseTX RJ45 ports) Type of fiber & connector shall be informed at the time of supply instruction as per requirement. Both end fiber patch cords in contractor scope. |
| 13 | 12way Adaptor Plate with adaptors for LIU (Supply & installation) | 12way Adaptor Plate with adaptors for LIU (Supply & installation) |
| 14 | MUX-DEMUXNos. of channels: Min.04, Both end SFPs to be supplied: yes, Speed of SFPs:1G, Type of fiber: SMPatch Cords: to be provided by contractor, SFP compatibility: Juniper / Brocade etc. as per actual switch installed at site. Installation & commissioning: Contractor scope, Switch Configuration: Contractor Scope.Note: NPCIL will provide the switches only. Link length to be considered as 20kms. Contractor shall be responsible for supply installation, commissioning and providing 04 nos. of links between identified locations.Any other required material like patch cords etc. (other than switch) shall be in scope of the contractor | MUX-DEMUXNos. of channels: Min.04, Both end SFPs to be supplied: yes, Speed of SFPs:1G, Type of fiber: SMPatch Cords: to be provided by contractor, SFP compatibility: Juniper / Brocade etc. as per actual switch installed at site. Installation & commissioning: Contractor scope, Switch Configuration: Contractor Scope.Note: NPCIL will provide the switches only. Link length to be considered as 20kms. Contractor shall be responsible for supply installation, commissioning and providing 04 nos. of links between identified locations.Any other required material like patch cords etc. (other than switch) shall be in scope of the contractor |
| 15 | Fibre Optic Power Meter | Fibre Optic Power Meter |
| 16 | RJ45 Connector for CAT6/Cat6A | RJ45 Connector for CAT6/Cat6A |
| 17 | Cat 6/6A Information Outlet | Cat 6/6A Information Outlet |
| 18 | 1G LR (20Kms) BiDi/Duplex SFP modules for Juniper/Brocade/Cisco/Dlink/any other make switches | 1G LR (20Kms) BiDi/Duplex SFP modules for Juniper/Brocade/Cisco/Dlink/any other make switches |
| 19 | 3Core4Sqmm copper cable for datacentre power connection | 3Core4Sqmm copper cable for datacentre power connection |
| 20 | HV 32A 2P+E AC BOX With HV 32A DP MCB | HV 32A 2P+E AC BOX With HV 32A DP MCB |
| 21 | 240VAC, 2P 25A MCB | 240VAC, 2P 25A MCB |
| 22 | Supply, Installation & cable dressing of 30*50*50mm(approx) metal cable channel in various meeting rooms floor by groove cutting or by screwing | Supply, Installation & cable dressing of 30*50*50mm(approx) metal cable channel in various meeting rooms floor by groove cutting or by screwing |
| 23 | RJ45 pvc port lock & dust blocker with key | RJ45 pvc port lock & dust blocker with key |
| 24 | Fiber (OFC) Cable Core Splicing (MM / SM) | Fiber (OFC) Cable Core Splicing (MM / SM) |
| 25 | OTDR of Fibre Optic Cable core for fault identification (Per Core) | OTDR of Fibre Optic Cable core for fault identification (Per Core) |
| 26 | Installation of Wall Rack Unit (Consumables like Anchor Fastner etc. in contractor scope) | Installation of Wall Rack Unit (Consumables like Anchor Fastner etc. in contractor scope) |
| 27 | Laying of Fiber (OFC) Cable (Indoor / Outdoor) | Laying of Fiber (OFC) Cable (Indoor / Outdoor) |
| 28 | Removal of wall rack unit and shifting of same to NPCIL stores at NUB/VSB/TVS. | Removal of wall rack unit and shifting of same to NPCIL stores at NUB/VSB/TVS. |
| 29 | Renewal of licenses and 03 year warranty of FortiGate-60E | Renewal of licenses and 03 year warranty of FortiGate-60E |
| 30 | Renewal of licenses and 03 year warranty of Check Point 750 | Renewal of licenses and 03 year warranty of Check Point 750 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender