Housing Urban and Rular Development Government Departments Closing in 7 days TDR #57059669

Tender For Annual Maintenance Estimate Of The electrical installation Work At Pmssy -Iii Building Of Bankura Sammilani Medical College And Hospital Under Bsmc And H Electrical Section -Ii , P.W.Dte. For The Period Of The Year Of 2024-25-----Repair, R

Issued by Government Departments · Bankura, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Aug 2026
7 days left
EMD
8500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bankura → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Annual Maintenance Estimate Of The electrical installation Work At Pmssy -Iii Building Of Bankura Sammilani Medical College And Hospital Under Bsmc And H Electrical Section -Ii , P.W.Dte. For The Period Of The Year Of 2024-25-----Repair, Renovation And Necessary Improvement Of Electrical Installation For Smooth Functioning Of Hospital Services And Better Patient Care Under Bankura Sammilani Medical College , Bankura.

BOQ

Name of Work:- Annual Maintenance Estimate of the E.I Work at PMSSY -III Building of Bankura Sammilani Medical College and Hospital under BSMC and H Electrical Section -II , P.W.Dte. For the period of the year of 2024-25-----Repair, Renovation and Necessary Improvement of Electrical Installation for Smooth Functioning of Hospital Services and Better Patient Care under Bankura Sammilani Medical College , Bankura.
Sl. No. Item Description
1Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 9 mtr
2Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish On board
3Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
4Supplying & Fixing of 240/415 Volt MCB of Breaking Capacity 10 kA & C characteristics on din rail of existing DBs & necessary connection.[ Fixing on existing HTPN & SPN DB] 6-32 Amp SP MCB
5Supply & Fixing angular batten holder (Anchor) on 75 mm dia PVC round block / round bakelite on wall/ceiling.
6Supply & Fixing 3 Way Ceilling rose with necessary connection .
7Supply & fixing of one way Circular box & Cover
8Supply & Delivery of daily weekly programmable electronic 240v 50 Hz Digital timer ( Make:- GIC Model:-67DDT0) on existing SS enclosure including necessary connections and time settings as per direction of EIC. [NS]
9Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 2.5 sq mm + 1 x 1.5 sq mm (For Power Board)
10Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
112.5 sq mm
12Supply & Delivery of 240 volt , 50 Hz , 12 '' inch (300 mm), 920 r.p.m. 48 Watt exhaust fan. with necessary bolts & nuts. ( Make-E.P.C Heavy Duty)
13Fixing only exhaust fan making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia incl. Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 12\\" (30 cm)
14Supply & Delivery of 240 V , 50 Hz , 36 W , 18 inches dia , full metal body wall bracket Fan ( Make - Crompton Model.- Storm 2 Plus or as approve by E.I.C.)
15Fixing of Wall Bracket on wall with necessaryS&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length etc to complete the installation and mending good the damages as per direction of EIC
16Supply & Fixing of 240 Volt ,50 Hz , Outdoor Type Street Light 90 Watt (Make -Phillips Model -BVP192 LED 132 CW HO NB FG A1 PSU GR SPD /Wipro or approved by EIC)
17Replacemnt of deffective main switch by supplying and fixing 415V, TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating as per direction of EIC. 400/415A
18Replacement of burnt out copper bar from LT panel by supply & fixing 50x6mm copper bar on existing insulator after dismantling the existing incl. making sufficent holes and necessary connections as per direction of EIC. [6 meter X 3.044 Kg/Mtr]
19Replacement of old deffective ML3 type contactor by supply & fixing new 415V, 40A ML3 type contactor on existing timer db and making necessary connections incl. buyback the deffective one as per direction of EIC. [Make: L&T, Model- SS9072]
20Supply of XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make:- Polycab/Havells/RR/Gloster/KEI] 4 Core 10 Sqmm
21Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as per GS.
22Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below as per GS. 4 core 10 sqmm
23Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials as per GS. 4 core 10 sqmm cable
24Replacement of old deffective rotery compressor by supply & fixing new 30000 Btu/Hr. capacity rotery compresor for 7.5 tr. AC machine incl. buyback the deffective one as per direction of EIC. [Make: L&T]
25SITC of AC Machine Supply , Delivery , Installation & Commissioning of 230V, 50Hz, 2 star , 2.0 TR capacity Non-Inverter , type Split Air-conditioner with 6200 watt coolining capacity ( Make- Hitachi Model no -IZEN ) or equvalent model of O-General/Daikin/ PWD Appvd ) with Remote , fitting accessories etc.
26Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ KEI / Gloster /approved by EIC) in suitable size ( 40/32/25 mm ) PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 4 sqmm + 1 x 2.5 sqmm [for AC ]
27Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
28Supply & Fixing 240 V, 25A Modular starter (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
29Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl.making earthing attachment, painting and mending good damages to building works
30Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
31S& F laying of -(i) gauge copper pipe 5/8\\" 0.7 mm thick for suction .(ii) copper pipe 1/4\\" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC(extra length for distance of ODU & IDU exceed 3 mtr.)
32S& Laying 3 core 4.0 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
33S & Laying 3 core 1.5 sqmm PVC insulated & unarmoured copper wire (make-- Gloster/Finolex/Havells/KEI) as per direction of EIC.
34S & F of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC. Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57059669
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 27-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Annual Maintenance Estimate Of The electrical installation Work At Pmssy -Iii Building Of Bankura Sammilani Medical College And Hospital Under Bsmc And H Electrical Section -Ii , P.W.Dte. For The Period Of The Year Of 2024-25-----Repair, Renovation And Necessary Improvement Of Electrical Installation For Smooth Functioning Of Hospital Services And Better Patient Care Under Bankura Sammilani Medical College , Bankura.
Basic Detail
Tender No WBPWDTE/AE/BMCESD/NIQ-13/Q of 2026-2027
Bidding Type Tender
Location
City Bankura
State West Bengal
Key Dates
Publish Date 17 Aug 2026
Submission Date 27 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 8500
Exemption Available
Document List
2911.pdf
BOQ_5090537.xls
c9b32bd7-3614-4b52-91a0-e4a79c5963ba.html
OID.pdf
Tendernotice_1 (25).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
pdf

2911.pdf

xls

BOQ_5090537.xls

html

c9b32bd7-3614-4b52-91a0-e4a79c5963ba.html

pdf

OID.pdf

pdf

Tendernotice_1 (25).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders