Housing Urban and Rular Development Government Departments Closing in 18 days TDR #57057925

Tender For Supply, Installation, Testing And Commissioning (Sitc) Of Firefighting Detection / Alarm System With Other Civil And Electrical Works At Skims Soura

Issued by Government Departments · Srinagar, Jammu and Kashmir
Tender Value
2.63 Crore
Estimated cost
Bid Submission
07 Sep 2026
18 days left
EMD
5.26 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing And Commissioning (Sitc) Of Firefighting Detection / Alarm System With Other Civil And Electrical Works At Skims Soura

BOQ

Name of Work:- Supply, installation, testing and commissioning (SITC) of Firefighting Detection / Alarm System with other Civil and Electrical Works at SKIMS Soura
Sl. No. Item Description
1Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with suitable Loops modules with hot plugabale loop cards and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8\\" Color LCD touch screen display with bright colors to indicate alarms and events, redundancy feature at CPU level, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 & VDS / UL & FM Certification.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
22 Loop Panel Expandable upto 4 Loops
34 Loop Panel Expandable upto 10 Loops
46 Loop Panel Expandable upto 20 Loops
5Supply, Installation, Testing and Commissioning of Active and networkable repeater panel with 4x20 character LCD display complete system function keys for programming and control like system reset, alarm acknowledgement, alarm silence, trouble acknowledgement etc. EN54 & VDS / UL & FM Certification.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
6Supply, Installation, Testing and Commissioning of addressable multisensor smoke/Heat detector including mounting base with LED etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. EN54 & VDS / UL & FM Certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
7Supply, Installation, Testing and Commissioning of Addressable Heat Detectors with combination of fixed type and rate of rise of temperature feature. Detetctor should have inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54 & VDS/ UL & FM Certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
8Supply, Installation, Testing and Commissioning of Intelligent Addressable smoke detector works based on Dual-Ray technology with two integrated light-scattering smoke sensors using 2 LEDs - blue & infrared. (Detector should comply to Test Fire 1). Detetctor should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. EN54 &VDS/ UL & FM certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
9Supply, Installation, Testing and Commissioning of addressable Flush mounted type Ultra slim Invisible smoke detector including mounting base, auto addressing feauture as required. Detetctor should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements.In addition the detectors are suitable for areas with heightened dust exposure, High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54 & VDS/ UL & FM Certification (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
10Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with flexible network structures with a maximun switching current of 1A @ 30V DC. EN54 & VDS / UL & FM Certification.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
11Supply, Installation, Testing and Commissioning of Addressable Monitor Module with one input & one output contacts, with inbuilt isolators & with 2 monitoring features, monitoring of a line with EOL resistor ,Potential free contact monitoring with Inbuilt isolators for flow switches, Panic Bars & other Third Party Inputs.EN54 & VDS / UL & FM Certification.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
12Supply, Installation, Testing & Commissioning of Response indicator for mounting on false ceiling at the entries of the cabin for indicating the operation for detectors in the above areas.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
13Supply, Installation, Testing and Commissioning of addessable manual break glass unit Double action with inbuilt isolators as per NFPA 72 style 7 wiring requirements, with flexible network structures & necessary fixing arrangements with key complete as required. EN54 & VDS / UL & FM Certification.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
14Supply, Installation, Testing and Commissioning of Addressable Loop Powered sounder with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with 32 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 92.1 dB(A), EN54 & VDS / UL & FM Certification.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
15Supply, Installation, Testing and Commissioning of Addressable Loop Powered Strobe with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with Strobe having Synchronized flash rate of 1 Hz and Light intensity > 2 cd, should be programmed from the panel. EN54 & VDS / UL & FM Certification.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica
16Survey, identification, tracing, cleaning, testing and reuse of existing concealed conduits of old/non-functional fire alarm system for laying new fire alarm cables, including the following works:Tracing of existing conduit routes using suitable tools such as fish tape, cable tracer, tone generator, and inspection of junction boxes- Opening and refixing of junction boxes, inspection covers, and access points as required- Removal of old/abandoned cables wherever feasible- Cleaning of conduits using air blowing, brushes, and suitable mechanical means- Checking conduit continuity and ensuring smooth passage by inserting draw wire end-to-end- Identification and marking of blocked/damaged conduits and partial rerouting wherever required- Ensuring conduit fill capacity, bend radius, and segregation from power cables as per relevant standards- Providing and inserting nylon/GI draw wire for future cable pulling- Minor repairs, sealing of conduit entries, and making good damages- Preparation and submission of as-built drawings showing traced routesComplete in all respects as required and as directed by Engineer-in-Charge.”Note:- Measurement shall be taken for the actual length of conduit successfully traced, cleaned, and certified usable for new cabling. Blocked or unusable conduit portions requiring replacement shall not be measured under this item but paid under respective new conduit items.
17Replacement of Damaged/Blocked Conduits:Providing and laying new conduit (MS; size/type as per site requirement) in place of damaged/blocked existing conduit including cutting, chasing, making good, and finishing
18Replacement of Damaged/Blocked Conduits:Providing and laying new conduit (PVC; size/type as per site requirement) in place of damaged/blocked existing conduit including cutting, chasing, making good, and finishing
19Supply, laying, fixing, testing and commissioning of 2 Core x 1.5 sq.mm twisted pair, shielded, FRLS copper cable for addressable fire alarm system loop wiring. The cable shall be laid through existing/new conduits or on cable trays/walls/ceilings using suitable saddles, clamps and accessories, including dressing, termination with glands, lugs, ferrules, testing for continuity and insulation, and complete as required.
20Fire Alarm Survival (CI) Cable (Critical Circuits)
21Power Supply Cable
22Supply, installation, fixing and laying of PVC conduits of suitable size for routing of fire alarm system cables, including all accessories such as bends, tees, couplers, inspection boxes, supports, hangers, clamps, fasteners, and hardware. The work shall include cutting, chasing, drilling, painting (if site requirement demands), and making good the surface, complete as required.
23Supply, installation, fixing and laying of MS conduits or cable trays of suitable size for routing of fire alarm system cables, including all accessories such as bends, tees, couplers, inspection boxes, supports, hangers, clamps, fasteners, and hardware. The work shall include cutting, chasing, drilling, welding (for MS tray), painting, and making good the surface, complete as required.
24Supply, Installation, Testing & Commissioning of Workstation, complete with enterprise-grade workstation, minimum Core i7/Core Ultra 7/Ryzen 7 processor, 16 GB RAM, 512 GB NVMe SSD, 24-inch Full HD monitor, licensed Windows OS, required accessories.Preferred Makes: Dell, HP, Lenovo, Asus.
25Interactive Graphics Display with OPS WorkstationSupply, Installation, Testing & Commissioning of minimum 75-inch 4K UHD Interactive Digital Display with compatible OPS Workstation, minimum Core i7/10th Gen or equivalent, 16 GB RAM and 512 GB SSD, with licensed OS complete as required.Preferred Makes: Samsung, LG, Sony, Sharp. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57057925
AUTHORITY Government Departments
TENDER VALUE 2.63 Crore
LAST DATE 07-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Supply, Installation, Testing And Commissioning (Sitc) Of Firefighting Detection / Alarm System With Other Civil And Electrical Works At Skims Soura
Basic Detail
Tender No eNIT No. HDE 31 of 2026_27 dated 17_08_2026
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 18 Aug 2026
Submission Date 07 Sep 2026
Open Date 08 Sep 2026
Finance
Tender Value 2.63 Crore
Tender Fee 5000
EMD 5.26 Lakhs
Exemption Not Available
Document List
1690cddf-0660-4b13-8afe-0e3805c30c16.html
BOQ_1072059.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

1690cddf-0660-4b13-8afe-0e3805c30c16.html

xls

BOQ_1072059.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders