Housing Urban and Rular Development Government Departments Closing in 0 days TDR #57057880

Tender For B.O.Q For Construction Of Acr At High School Cherpora, Anantnag B.W.O Electric Work

Issued by Government Departments · Anantnag, Jammu and Kashmir
Tender Value
97176
Estimated cost
Bid Submission
29 Aug 2026
0 days left
EMD
1943
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for B.O.Q For Construction Of Acr At High School Cherpora, Anantnag B.W.O Electric Work

BOQ

Name of Work:- B.O.Q for Construction of ACR at High School Cherpora, Anantnag B.W.O Electric work
Sl. No. Item Description
1Wiring for light point/fan point/exhaust fan point/call bell point with 2 × 1.5 sq.mm PVC insulated, FRLS copper conductor, 1100 V grade wires, conforming to IS 694, with conductors as per IS 8130 and insulation as per IS 5831, and having fire performance in accordance with IEC 60332, ISI marked with valid BIS license, complete with all accessories , ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor or OEMs/ firms holding ISO 9001 certification (Quality Management System) and shall be supplied with routine test certificates, and any material not conforming to the specified standards shall be rejected , complete with all accessories as required; . single core cable in surface / recessed medium class PVC conduit ( including cost of conduit), with modular switch ( Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Group-A
3Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit ( including cost of conduit)
4Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider LIvia /Crabtree athena make.)
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make ) single core cable in surface/ recessed medium class PVC conduit as required.
72 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
82 X 10 sq. mm + 1 X 6 sq. mm earth wire
9S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve ,Schneider / Legrand /ABB, / Havells ,/ Siemens/ L&T / Hager /BCH make OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge.
106-32 Amp SP MCB
1132amp DP MCB
1263amp DP MCB
13Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates.
14Supplying and fixing following way, Single pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager/ABB make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
1512 way , Double door
16Supply installation testing and commissioning of 9/10 W LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminum Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, separate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from Govt. approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Havel's /Wipro make / sample to be approved before installation..
17Supply, installation, testing and commissioning of exhaust fan of 150-200 mm sweep suitable for wall/window mounting, complete with necessary frame, mounting arrangement, louvers/shutter, and all accessories as required; the fan shall be of robust construction with high-grade engineering plastic/metal body, aerodynamically designed blades, and heavy-duty copper motor suitable for continuous operation, conforming to relevant Indian Standards and safety requirements of Havell /Bajaj/Crompton/ USHA/Orient OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge as per site requirement and necessary connections.
18Supply, installation, testing and commissioning of 1 star 1200 mm sweep ceiling fans of Havells / Crompton Greaves/Bajaj/ Usha , incl. cost of extension of GI rod (if required) and making of necessary connections.
19Supply installation testing and comm. of flood light 100 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell /Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job.
20Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular plate etc. as reqd.
21S/Laying ( partly overhead/ partly underground) , testing and commissioning of XLPE alluminum armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and al. lugs of required size.
2216 sq.mm 2 core ( armoured)
23Supply, installation, testing and Commissioning of 100 A Connector Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57057880
AUTHORITY Government Departments
TENDER VALUE 97176
LAST DATE 29-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for B.O.Q For Construction Of Acr At High School Cherpora, Anantnag B.W.O Electric Work
Basic Detail
Tender No NIT No.130//2026-27 Dt/17/08/2026
Bidding Type Tender
Location
City Anantnag
State Jammu and Kashmir
Key Dates
Publish Date 17 Aug 2026
Submission Date 29 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 97176
Tender Fee 200
EMD 1943
Exemption Not Available
Document List
BOQ_1071878.xls
d5416031-3b5d-4698-875e-4dd132d7be7e.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1071878.xls

html

d5416031-3b5d-4698-875e-4dd132d7be7e.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders