Power Boards / Undertakings / PSU Closing in 14 days TDR #57055090

Bids Are invited for Custom Bid For Services - Annual Inspection, Ibr Boiler Repair Work And Allied Work - Annual Ibr Inspection Related Works Of Horizontal, Smoke Tube, Oil Fired Package Boilers Of 6Tph Capacity F&At 100O C, Working Pressure 10.54 K

Issued by Boards / Undertakings / PSU · Mumbai Suburban, Maharashtra
Tender Value
25.54 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
14 days left
EMD
51082
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Custom Bid For Services - Annual Inspection, Ibr Boiler Repair Work And Allied Work - Annual Ibr Inspection Related Works Of Horizontal, Smoke Tube, Oil Fired Package Boilers Of 6Tph Capacity F&At 100O C, Working Pressure 10.54 Kg/Cm2 (G) (Make: Thermax Ltd, Model: Shellmax Sm60a) Complete As Per Ibr Guidelines. 1) Dismantling Of Mountings, Fittings, Accessories As Required For This Work. 2) Supply Of Turkish Head Wire Brush And Cleaning Of Smoke Side Water Side, Furnace Tubes Reverting Chamber, Etc, By Mechanical Means Using Wire Brush And Flexible Shaft Attachements. 3) Supply Of Descaling Chemical Of 100 Kg Each/ Boiler And Chemical Descaling Of Boiler Water Side Internals With Approved Make Sulphamic Acid With Corrosion Inhibitors As Per Approved Procedure & Manual Means. 4) Preparation And Offering The Boiler For Open And Hydrostatic Annual Inspection To The Directorate Of Steam Boilers, Maharashtra State, Complete As Per Scope Of The Work In Tender Specifications. , For Boiler No.1 Reg No: Mr 13426 , For Boiler No.2 Reg No: Mr 13496 , Supply And Application Of Refractory Cement 100 Kg (Approx) Of Approved Make And Repair, Application & Shape As Per Existing Profile In-Side The Furnace Around A) Burner And B) Access Rind Door , For Boiler No.1 Reg No: Mr 13426 , For Boiler No.2 Reg No: Mr 13496 , Replacement Of Plain Tubes/ Stay Tubes For Boiler No. Mr 13426 And / Or Boiler No. Mr 13496, Complete With A) Removal Of Existing Boiler Tubes Of Size As Given Below: With Mechanical Means Carefully Without Causing Any Damages To End Plates Seat; B) Measurement & Cutting, Grinding/Chamfering, Laying In Seat Holes Of Tubes; C) Expanding Of Tube Ends With Suitable Tube Flaring Tools; D) Seal Welding/ Fillet Welding Of Both The End With Endplates Along With All Required Ibr Stagewise Inspections As Recommended By Ibr Authorities. All Consumables Viz. Welding Electrode E7018-1 Or Equivalent, Other Consumables As Required Complete As Per Scope Of The Work In Tender Specifications. **Note: - Boiler Tubes Of Following Sizes Confirming To Bs 3059 Part-Ii, Gr. 360, Will Be Supplied By Barc As Free Issue Material. All Other Required Material For This Work Will Be In The Scope Of Contractor. , 2Nd Pass Plain Tubes Of Size: - Od 63.5Mm X Thickness 3.66Mm X Length 4.5M , 2Nd Pass Stay Tubes Of Size: - Od 63.5Mm X Thickness 6.35Mm X Length 4.5M , 3Rd Pass Plain Tubes Of Size: - Od 63.5Mm X Thickness 3.66Mm X Length 4.5M , 3Rd Pass Stay Tubes Of Size: - Od 63.5Mm X Thickness 6.35Mm X Length 4.5M , Fabrication, Supply, And Installation Of Furnace Safety Door Of Size 12 X 8 (Approx) With Required Bottom Or Top Frames, Nut & Bolts And Four Number Of Springs Complete As Per Design At Available On Boiler Front Main Door. , Supply And Testing At Site Of Ibr Approved 1/2 Bronze Globe Valve Confirming To Bronze Ibr 282(A)(Iv) Gr.B With Ibr Approval , Supply And Testing At Site Of Ibr Approved 3/4 Bronze Globe Valve Confirming To Bronze Ibr 282(A)(Iv) Gr.B With Ibr Approval , Supply, Installation, Testing, Ibr Approval Of Ibr Boiler Feedwater Stand Pipe Complete With The Following Works. 1) Preparation Of Proposed Drawing For The Work & Obtaining The Necessary Permission For Repair Of Crack Developed In 14Mm Thick Boiler Shell Plate Around Feed Water Standpipe (Based On The Ndt Conducted By Barc & Its Reports For A) Ut Flaw Detection, B) Metallography, C) Eddy Current And D) Ut Thickness Measurements). 2) Carrying Out The Repair On Shell Plate As Directed By Ibr Authorities Along With All Necessary Ndt As Suggested By Them With Final Approval. 3) Supply, Installation, Welding Ibr Inspection, Testing Of Seamless Carbon Steel 40Mm Nb Pipe Of Schedule-80 Feed Water Stand Pipe As Per Existing Profile/ Drawing Specifications Alongwith Suitable End Flanges, Gaskets, Fasteners As Required. 5) Arrangement For All Necessary Inspections, Lpt, Ut, Rt, Hydrotest, Etc As Recommended By Ibr Authority During This Work Around The Working Location I.E. Boiler Shell Around Feed Stand Pipe) 6) The Work Also Involves A) Dismantling Of Existing Nozzles, Supply Of All Required Materials For The Work, Stagewise Inspection By Ibr Authoritities, Carrying Out Any Additional Ndt Test As Recommended By The Inspector Around The Area Of Work, Submission Of All Test Reports Viz.Lpt, Ut, Hydro Test,Etc. As Requested By Ibr Authorities And Obtainnig Final Approval /Fitness Certificate For Operating The Boiler From Ibr And Submission To Barc. The Work Shall Be Carried Out By Authorised Class-1 Boiler Repairer By Ibr Authorities. , Removal Of Old Refractory, Metal Stiffeners In Furnace, Supply, Installation, Testing Of Metal Stiffeners, Refractory Cement As Per The Existing Profile Of Boiler Furnace Front And Back Side, Removal And Disposal Of Scrap/Debris Within 100M Lead. , Supply , Installation, Testing Of 15Mm Dia, 10M Length With 1/2 Bsp Thread And Metallic Cover Of 33 Mm Dia For The Tube Cleaning Machine. Cleaning Of 2Nd Pass & 3Rd Pass Tubes Of The Boiler And Complete Cleaning. , Supply, Erection, Testing And Commissioning Of 6Nb Cast Steel Non Return Valve On Main Steam Headers Line Confirming To A216 Gr.:Wcb, Trim-8, Ansi Pressure Class-150, With Flanged End Connections Of Reputed Make:/Ibr Well Known Foundaries/ Forges Recogonised By Central Boiler Board; Complete With Ibr Approval , Supply, Erection, Testing And Commissioning Of 6Nb Cast Steel Globe Valve Confirming To A216 Gr.:Wcb, Trim-8, Ansi Pressure Class-150, With Flanged End Connections Of Reputed Make:/Ibr Well Known Foundaries/ Forges Recogonised By Central Boiler Board; Complete With Ibr Approval

BOQ

Sl. No. Item TitleItem Description
1Annual IBR inspection related works of Horizontal, smoke tube, oil fired package boilers of 6TPH capacity F&at 100o C, working pressure 10.54 Kg/cm2 (g) (Make: Thermax Ltd, Model: Shellmax SM60A) complete as per IBR guidelines. 1) Dismantling of mountings, fittings, accessories as required for this work. 2) Supply of turkish head wire brush and cleaning of smoke side water side, furnace tubes reverting chamber, etc, by mechanical means using wire brush and flexible shaft attachements. 3) Supply of descaling chemical of 100 Kg each/ boiler and chemical descaling of boiler water side internals with approved make sulphamic acid with corrosion inhibitors as per approved procedure & manual means. 4) Preparation and offering the boiler for open and hydrostatic annual inspection to the Directorate of Steam Boilers, Maharashtra state, complete as per scope of the work in tender specifications.Annual IBR inspection related works of Horizontal, smoke tube, oil fired package boilers of 6TPH capacity F&at 100o C, working pressure 10.54 Kg/cm2 (g) (Make: Thermax Ltd, Model: Shellmax SM60A) complete as per IBR guidelines. 1) Dismantling of mountings, fittings, accessories as required for this work. 2) Supply of turkish head wire brush and cleaning of smoke side water side, furnace tubes reverting chamber, etc, by mechanical means using wire brush and flexible shaft attachements. 3) Supply of descaling chemical of 100 Kg each/ boiler and chemical descaling of boiler water side internals with approved make sulphamic acid with corrosion inhibitors as per approved procedure & manual means. 4) Preparation and offering the boiler for open and hydrostatic annual inspection to the Directorate of Steam Boilers, Maharashtra state, complete as per scope of the work in tender specifications.
2For boiler no.1 Reg No: MR 13426For boiler no.1 Reg No: MR 13426
3For boiler no.2 Reg No: MR 13496For boiler no.2 Reg No: MR 13496
4Supply and application of Refractory cement 100 Kg (Approx) of approved make and repair, application & shape as per existing profile in-side the furnace around a) burner and b) access rind doorSupply and application of Refractory cement 100 Kg (Approx) of approved make and repair, application & shape as per existing profile in-side the furnace around a) burner and b) access rind door
5For boiler no.1 Reg No: MR 13426For boiler no.1 Reg No: MR 13426
6For boiler no.2 Reg No: MR 13496For boiler no.2 Reg No: MR 13496
7Replacement of Plain tubes/ Stay tubes for Boiler no. MR 13426 and / Or Boiler No. MR 13496, complete with a) Removal of existing boiler tubes of size as given below: with mechanical means carefully without causing any damages to end plates seat; b) Measurement & cutting, grinding/chamfering, laying in seat holes of tubes; c) Expanding of tube ends with suitable tube flaring tools; d) Seal welding/ fillet welding of both the end with endplates along with all required IBR stagewise inspections as recommended by IBR authorities. All consumables viz. Welding electrode E7018-1 or equivalent, other consumables as required complete as per scope of the work in tender specifications. **Note: - Boiler tubes of following sizes confirming to BS 3059 part-II, Gr. 360, will be supplied by BARC as free issue material. All other required material for this work will be in the scope of contractor.Replacement of Plain tubes/ Stay tubes for Boiler no. MR 13426 and / Or Boiler No. MR 13496, complete with a) Removal of existing boiler tubes of size as given below: with mechanical means carefully without causing any damages to end plates seat; b) Measurement & cutting, grinding/chamfering, laying in seat holes of tubes; c) Expanding of tube ends with suitable tube flaring tools; d) Seal welding/ fillet welding of both the end with endplates along with all required IBR stagewise inspections as recommended by IBR authorities. All consumables viz. Welding electrode E7018-1 or equivalent, other consumables as required complete as per scope of the work in tender specifications. **Note: - Boiler tubes of following sizes confirming to BS 3059 part-II, Gr. 360, will be supplied by BARC as free issue material. All other required material for this work will be in the scope of contractor.
82nd pass plain tubes of size: - OD 63.5mm x thickness 3.66mm x length 4.5m2nd pass plain tubes of size: - OD 63.5mm x thickness 3.66mm x length 4.5m
92nd pass Stay tubes of size: - OD 63.5mm x thickness 6.35mm x length 4.5m2nd pass Stay tubes of size: - OD 63.5mm x thickness 6.35mm x length 4.5m
103rd pass plain tubes of size: - OD 63.5mm x thickness 3.66mm x length 4.5m3rd pass plain tubes of size: - OD 63.5mm x thickness 3.66mm x length 4.5m
113rd pass Stay tubes of size: - OD 63.5mm x thickness 6.35mm x length 4.5m3rd pass Stay tubes of size: - OD 63.5mm x thickness 6.35mm x length 4.5m
12Fabrication, supply, and installation of furnace safety door of size '12\\" x 8\\" (Approx) with required bottom or top frames, nut & bolts and four number of springs complete as per design at available on boiler front main door.Fabrication, supply, and installation of furnace safety door of size '12\\" x 8\\" (Approx) with required bottom or top frames, nut & bolts and four number of springs complete as per design at available on boiler front main door.
13Supply and testing at site of IBR approved 1/2'' Bronze globe valve confirming to Bronze IBR 282(a)(iv) Gr.B with IBR approvalSupply and testing at site of IBR approved 1/2'' Bronze globe valve confirming to Bronze IBR 282(a)(iv) Gr.B with IBR approval
14Supply and testing at site of IBR approved 3/4'' Bronze globe valve confirming to Bronze IBR 282(a)(iv) Gr.B with IBR approvalSupply and testing at site of IBR approved 3/4'' Bronze globe valve confirming to Bronze IBR 282(a)(iv) Gr.B with IBR approval
15Supply, installation, testing, IBR approval of IBR boiler feedwater stand pipe complete with the following works. 1) Preparation of proposed drawing for the work & Obtaining the necessary permission for repair of crack developed in 14mm thick boiler shell plate around feed water standpipe (based on the NDT conducted by BARC & its reports for a) UT flaw detection, b) Metallography, c) Eddy Current and d) UT Thickness measurements). 2) Carrying out the repair on shell plate as directed by IBR Authorities along with all necessary NDT as suggested by them with final approval. 3) Supply, installation, welding IBR inspection, testing of seamless Carbon steel 40mm NB pipe of Schedule-80 feed water stand pipe as per existing profile/ Drawing specifications alongwith suitable end flanges, gaskets, fasteners as required. 5) Arrangement for all necessary inspections, LPT, UT, RT, Hydrotest, etc as recommended by IBR authority during this work around the working location i.e. Boiler shell around feed stand pipe) 6) The work also involves a) dismantling of existing nozzles, supply of all required materials for the work, stagewise inspection by IBR authoritities, carrying out any additional NDT test as recommended by the inspector around the area of work, submission of all test reports viz.LPT, UT, Hydro test,etc. as requested by IBR authorities and obtainnig final approval /fitness certificate for operating the boiler from IBR and submission to BARC. The work shall be carried out by authorised Class-1 boiler repairer by IBR authorities.Supply, installation, testing, IBR approval of IBR boiler feedwater stand pipe complete with the following works. 1) Preparation of proposed drawing for the work & Obtaining the necessary permission for repair of crack developed in 14mm thick boiler shell plate around feed water standpipe (based on the NDT conducted by BARC & its reports for a) UT flaw detection, b) Metallography, c) Eddy Current and d) UT Thickness measurements). 2) Carrying out the repair on shell plate as directed by IBR Authorities along with all necessary NDT as suggested by them with final approval. 3) Supply, installation, welding IBR inspection, testing of seamless Carbon steel 40mm NB pipe of Schedule-80 feed water stand pipe as per existing profile/ Drawing specifications alongwith suitable end flanges, gaskets, fasteners as required. 5) Arrangement for all necessary inspections, LPT, UT, RT, Hydrotest, etc as recommended by IBR authority during this work around the working location i.e. Boiler shell around feed stand pipe) 6) The work also involves a) dismantling of existing nozzles, supply of all required materials for the work, stagewise inspection by IBR authoritities, carrying out any additional NDT test as recommended by the inspector around the area of work, submission of all test reports viz.LPT, UT, Hydro test,etc. as requested by IBR authorities and obtainnig final approval /fitness certificate for operating the boiler from IBR and submission to BARC. The work shall be carried out by authorised Class-1 boiler repairer by IBR authorities.
16Removal of old refractory, metal stiffeners in furnace, Supply, installation, testing of metal stiffeners, refractory cement as per the existing profile of boiler furnace front and back side, removal and disposal of scrap/debris within 100m lead.Removal of old refractory, metal stiffeners in furnace, Supply, installation, testing of metal stiffeners, refractory cement as per the existing profile of boiler furnace front and back side, removal and disposal of scrap/debris within 100m lead.
17Supply , installation, testing of 15mm dia, 10m length with 1/2\\" BSP thread and metallic cover of 33 mm dia for the tube cleaning machine. Cleaning of 2nd pass & 3rd pass tubes of the boiler and complete cleaning.Supply , installation, testing of 15mm dia, 10m length with 1/2\\" BSP thread and metallic cover of 33 mm dia for the tube cleaning machine. Cleaning of 2nd pass & 3rd pass tubes of the boiler and complete cleaning.
18Supply, erection, testing and commissioning of 6\\"NB Cast steel Non Return valve on main steam headers line confirming to A216 Gr.:WCB, Trim-8, ANSI pressure class-150, with flanged end connections of reputed make:/IBR well known foundaries/ forges recogonised by Central Boiler Board; complete with IBR approvalSupply, erection, testing and commissioning of 6\\"NB Cast steel Non Return valve on main steam headers line confirming to A216 Gr.:WCB, Trim-8, ANSI pressure class-150, with flanged end connections of reputed make:/IBR well known foundaries/ forges recogonised by Central Boiler Board; complete with IBR approval
19Supply, erection, testing and commissioning of 6\\"NB Cast steel Globe valve confirming to A216 Gr.:WCB, Trim-8, ANSI pressure class-150, with flanged end connections of reputed make:/IBR well known foundaries/ forges recogonised by Central Boiler Board; complete with IBR approvalSupply, erection, testing and commissioning of 6\\"NB Cast steel Globe valve confirming to A216 Gr.:WCB, Trim-8, ANSI pressure class-150, with flanged end connections of reputed make:/IBR well known foundaries/ forges recogonised by Central Boiler Board; complete with IBR approval

AI Tender Summary

OUR REF NO 57055090
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 25.54 Lakhs
LAST DATE 07-09-2026
Authority
Authority Name Bhabha Atomic Research Centre
Work Description Bids Are invited for Custom Bid For Services - Annual Inspection, Ibr Boiler Repair Work And Allied Work - Annual Ibr Inspection Related Works Of Horizontal, Smoke Tube, Oil Fired Package Boilers Of 6Tph Capacity F&At 100O C, Working Pressure 10.54 Kg/Cm2 (G) (Make: Thermax Ltd, Model: Shellmax Sm60a) Complete As Per Ibr Guidelines. 1) Dismantling Of Mountings, Fittings, Accessories As Required For This Work. 2) Supply Of Turkish Head Wire Brush And Cleaning Of Smoke Side Water Side, Furnace Tubes Reverting Chamber, Etc, By Mechanical Means Using Wire Brush And Flexible Shaft Attachements. 3) Supply Of Descaling Chemical Of 100 Kg Each/ Boiler And Chemical Descaling Of Boiler Water Side Internals With Approved Make Sulphamic Acid With Corrosion Inhibitors As Per Approved Procedure & Manual Means. 4) Preparation And Offering The Boiler For Open And Hydrostatic Annual Inspection To The Directorate Of Steam Boilers, Maharashtra State, Complete As Per Scope Of The Work In Tender Specifications. , For Boiler No.1 Reg No: Mr 13426 , For Boiler No.2 Reg No: Mr 13496 , Supply And Application Of Refractory Cement 100 Kg (Approx) Of Approved Make And Repair, Application & Shape As Per Existing Profile In-Side The Furnace Around A) Burner And B) Access Rind Door , For Boiler No.1 Reg No: Mr 13426 , For Boiler No.2 Reg No: Mr 13496 , Replacement Of Plain Tubes/ Stay Tubes For Boiler No. Mr 13426 And / Or Boiler No. Mr 13496, Complete With A) Removal Of Existing Boiler Tubes Of Size As Given Below: With Mechanical Means Carefully Without Causing Any Damages To End Plates Seat; B) Measurement & Cutting, Grinding/Chamfering, Laying In Seat Holes Of Tubes; C) Expanding Of Tube Ends With Suitable Tube Flaring Tools; D) Seal Welding/ Fillet Welding Of Both The End With Endplates Along With All Required Ibr Stagewise Inspections As Recommended By Ibr Authorities. All Consumables Viz. Welding Electrode E7018-1 Or Equivalent, Other Consumables As Required Complete As Per Scope Of The Work In Tender Specifications. **Note: - Boiler Tubes Of Following Sizes Confirming To Bs 3059 Part-Ii, Gr. 360, Will Be Supplied By Barc As Free Issue Material. All Other Required Material For This Work Will Be In The Scope Of Contractor. , 2Nd Pass Plain Tubes Of Size: - Od 63.5Mm X Thickness 3.66Mm X Length 4.5M , 2Nd Pass Stay Tubes Of Size: - Od 63.5Mm X Thickness 6.35Mm X Length 4.5M , 3Rd Pass Plain Tubes Of Size: - Od 63.5Mm X Thickness 3.66Mm X Length 4.5M , 3Rd Pass Stay Tubes Of Size: - Od 63.5Mm X Thickness 6.35Mm X Length 4.5M , Fabrication, Supply, And Installation Of Furnace Safety Door Of Size 12 X 8 (Approx) With Required Bottom Or Top Frames, Nut & Bolts And Four Number Of Springs Complete As Per Design At Available On Boiler Front Main Door. , Supply And Testing At Site Of Ibr Approved 1/2 Bronze Globe Valve Confirming To Bronze Ibr 282(A)(Iv) Gr.B With Ibr Approval , Supply And Testing At Site Of Ibr Approved 3/4 Bronze Globe Valve Confirming To Bronze Ibr 282(A)(Iv) Gr.B With Ibr Approval , Supply, Installation, Testing, Ibr Approval Of Ibr Boiler Feedwater Stand Pipe Complete With The Following Works. 1) Preparation Of Proposed Drawing For The Work & Obtaining The Necessary Permission For Repair Of Crack Developed In 14Mm Thick Boiler Shell Plate Around Feed Water Standpipe (Based On The Ndt Conducted By Barc & Its Reports For A) Ut Flaw Detection, B) Metallography, C) Eddy Current And D) Ut Thickness Measurements). 2) Carrying Out The Repair On Shell Plate As Directed By Ibr Authorities Along With All Necessary Ndt As Suggested By Them With Final Approval. 3) Supply, Installation, Welding Ibr Inspection, Testing Of Seamless Carbon Steel 40Mm Nb Pipe Of Schedule-80 Feed Water Stand Pipe As Per Existing Profile/ Drawing Specifications Alongwith Suitable End Flanges, Gaskets, Fasteners As Required. 5) Arrangement For All Necessary Inspections, Lpt, Ut, Rt, Hydrotest, Etc As Recommended By Ibr Authority During This Work Around The Working Location I.E. Boiler Shell Around Feed Stand Pipe) 6) The Work Also Involves A) Dismantling Of Existing Nozzles, Supply Of All Required Materials For The Work, Stagewise Inspection By Ibr Authoritities, Carrying Out Any Additional Ndt Test As Recommended By The Inspector Around The Area Of Work, Submission Of All Test Reports Viz.Lpt, Ut, Hydro Test,Etc. As Requested By Ibr Authorities And Obtainnig Final Approval /Fitness Certificate For Operating The Boiler From Ibr And Submission To Barc. The Work Shall Be Carried Out By Authorised Class-1 Boiler Repairer By Ibr Authorities. , Removal Of Old Refractory, Metal Stiffeners In Furnace, Supply, Installation, Testing Of Metal Stiffeners, Refractory Cement As Per The Existing Profile Of Boiler Furnace Front And Back Side, Removal And Disposal Of Scrap/Debris Within 100M Lead. , Supply , Installation, Testing Of 15Mm Dia, 10M Length With 1/2 Bsp Thread And Metallic Cover Of 33 Mm Dia For The Tube Cleaning Machine. Cleaning Of 2Nd Pass & 3Rd Pass Tubes Of The Boiler And Complete Cleaning. , Supply, Erection, Testing And Commissioning Of 6Nb Cast Steel Non Return Valve On Main Steam Headers Line Confirming To A216 Gr.:Wcb, Trim-8, Ansi Pressure Class-150, With Flanged End Connections Of Reputed Make:/Ibr Well Known Foundaries/ Forges Recogonised By Central Boiler Board; Complete With Ibr Approval , Supply, Erection, Testing And Commissioning Of 6Nb Cast Steel Globe Valve Confirming To A216 Gr.:Wcb, Trim-8, Ansi Pressure Class-150, With Flanged End Connections Of Reputed Make:/Ibr Well Known Foundaries/ Forges Recogonised By Central Boiler Board; Complete With Ibr Approval
Basic Detail
Tender No GEM/2026/B/7920485
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 17 Aug 2026
Submission Date 07 Sep 2026
Open Date 07 Sep 2026
Finance
Tender Value 25.54 Lakhs
Tender Fee Ref. Documents
EMD 51082
Exemption Available
Document List
603b585b-8204-4331-8a9b-aff57ceff715.pdf
1786707706.xlsx
1786707744.pdf
1786707749.pdf
1786707783.pdf
1786707792.pdf
1786707798.pdf
1786707919.pdf
1786708013.pdf
1786708021.pdf
1786959643.pdf
1786960379.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

603b585b-8204-4331-8a9b-aff57ceff715.pdf

xlsx

1786707706.xlsx

pdf

1786707744.pdf

pdf

1786707749.pdf

pdf

1786707783.pdf

pdf

1786707792.pdf

pdf

1786707798.pdf

pdf

1786707919.pdf

pdf

1786708013.pdf

pdf

1786708021.pdf

pdf

1786959643.pdf

pdf

1786960379.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders