Tender For Special Repair To Bldg No T- 368 In Zone P At Agartala Military Station
Tender Value
8.93 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
15 days left
EMD
17860
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
agartala → Tripura
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No T- 368 In Zone P At Agartala Military Station
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of old plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed |
| 2 | M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified and as directed. |
| 3 | S&F of 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip & straight flashings (length & girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 5 | S&F Steel work in tubular trusses and vertical posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as specified and as directed. |
| 6 | S&F Rolled mild steel purlins ,crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc.Gde Fe410-0 or Fe 310-O complete as specified and as directed. |
| 7 | S&F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends;screwed end to be fitted with washers and one hexagonal or square nut.dia of bolt 11 to 15mm & length exc 5cm long and n exc10cm complete as specified and as directed. |
| 8 | M&L for two coat of synthetic enamelled paint over coat of red oxide zinc chrome on steel surfaces and roof sheets over 10 cm width or girth including preparation of new surfaces. |
| 9 | Demolition of brick work or stone/boulder masonry, built in CM including all quoins, pillars etc. |
| 10 | M&L for Brick work with locally available best quality subclass B bricks, straight or curved on plan exc 6m mean radiun built in CM 1:4 complete all as specified and as directed. |
| 11 | M&L Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls, built in cm 1:4 complete all as specified and as directed. |
| 12 | Taking down plaster on brick or stone wall, ceiling etc incl racking out joints hacking for keys scrubbing down with water etc complete all as specified and directed.etc. |
| 13 | M&L 15mm thick rendering in CM (1:4) on brick work/ concrete surfaces in two layers (10mm backing coat and 5mm finishing coat mixed with WPC @ 200ml/bag of cement,) finished even and fair complete all as specified and as directed.(Note: Water proofing compound measured & paid separately) |
| 14 | M&L 10 mm thick rendering in CM (1:6) on than fair faces of brick work or concrete surfaces without using extra cement complete all as specified and as directed. |
| 15 | M&L applying Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) after applying 1mm thick wall care putty with preparation of new plastered surfaces complete all as specified and as directed. |
| 16 | M & L for preparation of new plastered surfaces by applying 2mm thick wall care putty and applying two coats of oil bound distemer over a coat of primer on new plastered surfaces complete all as specified and as directed . |
| 17 | M&L complete removal of internal wall finishes by scrapping down and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) after applying 1mm thick wall care putty on old plastered surfaces complete all as specified and as directed. |
| 18 | M & L complete removal of internal wall finishes by scrapping down and preparation of old plastered surfaces by applying 2mm thick wall care putty and applying two coats of oil bound distemer over a coat of primer on old plastered surfaces complete all as specified and directed. |
| 19 | Dismantling wall / ceiling board (fibre pulp insulation) or insulation boards any thickness including cover fillets etc complete all as specified and directed. |
| 20 | S&F asbestos fibre cement building board 4 mm thick for fixed or laid to GI frame work with screws as in ceiling complete as specified and as directed. |
| 21 | M & L Preparing new surfaces of ceiling and applying two coats of oil emulsion distempering complete as specified and as directed. |
| 22 | Material & Labour for writing letters or figures (block, Roman, Italic or Indian) n.exc.30 cm high complete all as specified and directed. |
| 23 | Supply only liquid water proofing compound |
| 24 | Taking down chowkat with shutter/without taking off shutter from the frame n exe 1.50 Sqm each complete all as specified and directed. |
| 25 | S&F powder coated (minimum 50 micron thick) aluminium window sliding type three track (2 glazed & one gauze shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing , screws, handle, locking arrangement and 4.0mm thick plain/tinted glass with stainless steel mosquito proof gauge 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and making good disturbed surface of wall complete all as specified and as directed. (Note: Window opening size to be measured.) |
| 26 | S&F Powder coated aluminium louvered ventilators of size 600X600mm with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazing cleats, rubber packing , anodised aluminium snap beading,screws, anodised aluminium fittings and 5.5mm thick Frosted tinted glass fixed in panels with suitable locking arrangements and making good the surface complete all as specified and as directed. |
| 27 | M & L for anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design /pattern with approved standard section and fixed to the existing window frame with cp brass/stainless steel screws @ 200 mm centre to centre including cutting the grill to proper opening of size for fixing and operation of hAndles and fixing approvedanodised aluminium standard section around the opening all complete as reqdete all as specified and as directed. (Aluminium grill Weight per sqm is not less than 1kg) |
| 28 | Taking down chowkat with shutter/without taking off shutter from the frame exe 1.50 Sqm but n.exc 4.00 Sqm each complete all as specified and directed. |
| 29 | S&F pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125 x60 mm complete all as specified and as directed. |
| 30 | M&L Plain cement concrete in bed block and filling of door frame type C-1 1:3:6 (20 mm graded stone aggregate) complete all as specified and as directed. |
| 31 | S&F 35mm thick Factory made Flush shutter solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed. |
| 32 | S&F 35mm thick2nd class hard wood for Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed. |
| 33 | M&L for two coats of synthetic enamel paint over one coat of pink primer on wooden surfaces of any description, not otherwise described, over 10cm width or girth incl preparation of new surfaces complete as specified and directed. |
| 34 | S&F Butt hinges, extruded aluminum alloy with galvanized MS sheet hinges pin anodized of100 mm size type B-21. |
| 35 | S&F 150mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and as directed. |
| 36 | S&F 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed. |
| 37 | S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 38 | Demolition of cement concrete(un Reinforced) of any description in any position not otherwise specifically provided for etc. complete all as specified and directed. |
| 39 | Material and labour 75 mm thick PCC 1:3:6 type C2 using 40 mm graded aggregate as in plinth protection finished fair and even w/o using extra cement and making groove of 10mm width at every 3m intervals and at diagonals and filling the joints with bitumen mastic( a mix of bitumen and sand in 1:1 by weight) complete all as specified and directed. |
| 40 | Supply & Fix in repair 25mm dia mild steel chromium plated curtain rod fixing with brackets, stop, rollers complete all as specified and as directed. |
| 41 | Supply and fix in repairs 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls only integral water proofing compound complete all as specified and as directed |
| 42 | Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, Bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holder etc by unscrewing from board carefully and keep aside for schedule of credit to contactor including making good of the disturbed surfaces, all as specified and directed. |
| 43 | Material and labour for point wiring (surface type) with PVC insulated, 1100 volts FRLS grade, unsheathed, single core, multistranded copper conductors 1.5 sq mm (nominal area) for phase, neutral and continuous earth wire drawn through and including PVC Casing -N- capping (medium duty) double lock type of 20mm size with fittings & accessories, pressed steel sunken terminal box(Consealed in wall) made out of 1.6 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 0.8 mm thick bakelite sheet for fixing switches, regulator etc and earth continuity conductor shall be connected to common earth and earth dolly for one light / fan point controlled by one 1 way switch complete all as specified & directed. Note : Cost of cutting of wall, if any, for housing of pressed steel sunken terminal box and also making good the disturbed surfaces are deemed to be included in the unit rate. |
| 44 | All as per item No 43 above but for one 3/5 pin 6 Amps socket outlet on the same board with other switches. |
| 45 | All as per item No 43 above but for one 3/5 pin 6 Amps socket outlet on the independent board. |
| 46 | Material and labour for point wiring (surface type) with PVC insulated, 1100 volts FRLS grade, unsheathed, single core, multistranded copper conductors 2.5 sqmm (nominal area) for phase & neutral and 2.5 Sqmm (nominal area) continuous earth wire drawn through and including PVC Casing -N- capping double lock type of 20mm size with fittings & accessories, pressed steel sunken terminal box (Consealed in wall) made out of 1.6mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3mm thick bakelite sheet for fixing switches, sockets, regulator etc and earth continuity conductor shall be connected to common earth and earth dolly for 3/5 pin 16 Amps socket outlet complete all as specified & directe. |
| 47 | Material and labour for switch socket combination multi purpose 2 in 1, 5 Pin,5 and 15 Amps, flush type ISI marked complete all as specified and as directed. |
| 48 | Materials & labour for switch piano flush button 5/6 Amps single pole, 1 way 240 V ISI marked complete all as specified and as directed. |
| 49 | Material and labour for switch socket combination 5 Pin, 6 Amps flush type ISI marked complete all as specified and as directed |
| 50 | Materials and labour for socket out let 5 Pin, 6 Amps flush type complete all as specified and as directed. |
| 51 | Materials and labour for ceiling rose surface bakelite,PVC/poly 65 x 50mm, three terminals complete all as specified and as directed. |
| 52 | Materials and labour for electronic fan regulator (step rotary type), AC 240 volt complete all as specified and as directed. |
| 53 | Material and labour for sub main wiring with two single core PVC insulated cable with Copper conducter unsheathed cable (FRLS) of size 4.0 sqmm drawn through & including PVC conduit with 4.0 sqmm PVC insulated copper wire single core for continuous earthing after taking out old unservicable submain wiring complete all as directed. |
| 54 | Supply & fixing MCB DB (Double door) SPN, 8 way sheet steel with bus bar, din rail, neutral link and earth bar with fitting & fixtures including taking down old one all as specified and directed. |
| 55 | Supply and fix sheet metal enclosure /TPN DBs (Double door) 4 way with 200 amps rated busbar suitable for MCB including taking down old unserviceable enclosure one complete all as specified as directed. |
| 56 | Supply and fix MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'B' series with all incoming / outgoing connections with proper size of lugs complete inculding taking down the old unserviceable one all as specified as directed. |
| 57 | Supply and fix MCB single pole & neutral 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete inculding taking down the old unserviceable one all as specified as directed |
| 58 | Supply and fix in repairs MCB triple pole & neutral 63 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections suitable for 4 way type TPN DB in double door with proper size of aluminium lugs complete all as specified as directed . |
| 59 | Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100mm C/C both way and two Nos lifting handle made of 12mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete all as specified in electrical plate No 3 of SSR Part-I including taking down old earthing. |
| 60 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Including taking down old unserceable light fitting complete all as specified and as directed. |
| 61 | Taking down ceiling fans/ of any size and kept in store complete all as specified and directed. |
| 62 | Hanging/refixing ceiling fans of any size complete all as specified and directed. |
| 63 | NOTES :-1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule 'A' notes for details. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender