Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #57052475

Tender For Special Repair To Bldg No P-04 (Otm Accn) And Allied Wks At 410 (I) Engrs Sqn At Akhnoor Mil Stn Under Ge (S) Akhnoor

Issued by Statutory Bodies & Commissions/Committees · Jammu, Jammu and Kashmir
Tender Value
57.55 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
21 days left
EMD
1.11 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Bldg No P-04 (Otm Accn) And Allied Wks At 410 (I) Engrs Sqn At Akhnoor Mil Stn Under Ge (S) Akhnoor

BOQ

Name of Work:- SPECIAL REPAIR TO BLDG NO P-04 (OTM ACCN) AND ALLIED WKS AT 410 (I) ENGRS SQN AT AKHNOOR MIL STN UNDER GE (S) AKHNOOR
Sl. No. Item Description
1Demolition of cement concrete (unreinforced) concrete in ground floors and paving n-exc 15cm thickness ( below or above ground floors.) , complete all as specified and as directed.
2M&L for 75mm thick cement conc one 1:3:6 type C2 using 20mm graded stone aggregate as in plinth protection joint filled with bitumen sand mixer finished even and smooth without using extra cement, complete all as specified and as directed.
3M&L cement concrete type B1 1:2:4 using 20mm graded stone aggregate 25mm thick as in flooring etc, complete all as specified and as directed.
4M&L screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement 1:6, complete all as specified and directed.
5M&L non-skid ceramic coloured designer pattern tiles 300x300mmx7mm thick in floors etcset jointed in neat cement slurry and pointed in white cement or coloured cement to match etc, complete all as specified and as directed.
6Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed.
7Rendering 10mm thick on fair faces of brick work or concrete surface in cm 1:4 as for tiles screed bed , complete all as specified and as directed.
8S&F Non Skid (coloured) ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15 mm thick screed bed in cement mortar (1:6) complete all as specifed and as directed.
9M&L glazed ceramic coloured designer pattern tiles 450mmx 300mmx7mm thick on vertical surface such as skirt, Dado etc. set and jointed in white colour cement, complete all as specified and directed.
10S&F Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,on vertical surface such as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by engineer in charge
11M&L for Machine cut kota stone slab flooring 18-20 mm thick over and included cement screed base of 20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
12M&L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick rendering and jointed with jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingcomplete all as specified and as directed.
13M&L for granite 18-20 mm thick(table rubbed and polished) in cooking platform and like in cement mortar 1:4 including pointing in white cement(1:2) using marble dust making holes in RCC shelves suitable for gas pipe with round edges where required complete all as specified and as directed.
14Demolition for cement conc exc 15cm thickness but above ground floor as sunken floor , complete all as specified and as directed .
15M&L for 15mm thick rendering in 1:3 CM with using 3% WPC as in sunken portion complete all as directed.
16M&L for applying evenly a tack coat of industrial bituminous 85/25 @ 1.20 Kg per square mtr including cleaning surfaces, complete all as specified and as directed.
17M&L cement concrete type B1 1:2:4 using 20mm graded stone aggregate 25mm thick as in flooring with using 3% WPC etc. ,complete all as specified and as directed. (Note water proofing compound shall be measured and paid separately).
18M&L PCC 1:5:10 type E-2 using 40mm graded stone aggregates as filling under (sunken slab) floors, complete all as specified and as directed.
19M&L for 40mm thick Plain Cement concrete type B0 1:2:4 using 12.50mm graded stone aggregate as in floor etc complete laid finished even and rough to receive plaster without using extra cement complete all as specified and as directed.
20M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregates as sides of rounded or chamfered on edges of sunken floor complete all as specified and directed.
21S&F 32mm dia G I pipe beveled cut at both ends by making hole in walls sunken portion approx above the R C C slab and ceiling finished the hole with cement mortar 1:3,n.exc to match with existing surfaces complete etc, complete all as specified and as directed.
22M&LGrubbing up bushes , tree trunks portion not exc 30CM girth including cutting of trees/bushes grown in over wall and roofs digging out roofs and making good disturbed area of walls and roofs with PCC type C-1 , 1:3:6 using 20mm graded crushed stone aggregates and matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
23M&L for repairing RCC projection chajjas, roof, facia etc. by necessary preparation, scraping, cutting, chiseling derusting and cleaning exposed reinforcement surfaces of damaged, loose RCC surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregates and reinforcement with welded mesh of weight exc 2Kg per Sqm but n.exc 3Kg/Sqm with or without facia and finished with cement mortar 1:3 using coarse sand and work in patches area n.exc 5 Sqm and thickness RCC member n.exc 100mm incl necessary formwork and applying two coats of finishes to match with the existing surfaces at any height complete. (note: welded mesh to be paid separately)
24S&F for Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement ,n.exc 4 Kg per Sqm by weight, complete all as specified and as directed by Engineer-In-Charge.
25Taking down of existing roof treatment from roof and terrance roughening surface of old concrete roof by picking sweeping clean and washing down with water to remove dust etc and applying roof treatment with the following specification(a) Applying cement slurry over concrete surfaces @ 3Kg/Sqm.(b) Rendering 15mm thick in cement mortar (1:4) mixed with water proffing compound as per manfactures instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and evn including curing the plastered surfaces for 7 days by ponding of water over the roof (leveling course).(c) Applying evenly one coat of cold bituminous primer conferming to IS 3384-1986 @ 0.30 liter per Sqm on the cleaned plastered surfaces.(d) Applying evenly one coat of blown hot bituminof grade 85/25 @1.2Kg per Sqm primed surfaces.(e) Applying a layer of APP base polymerie membrane, 3mm thick (minimum) weighing 3.50 Kg per sqm reinforces) with polyster non woven fabric wighing not les than 160 gms per Aqm by torch application. The overlap shall be not less than 100mm on transverse direction and 75 mm on longitudinal direction and sealing oversaps.(f) Applying evenly one coat of aluminium paint @ 0.10 litre per Sqm over the APP based polymeric membrane.
26M&L for Providing 20mm thick precast PCC tiles jointed & pointed flush in CM 1:6 over 15mm thick bedding layer of CM (1:6) using 5% creosote oil ,complete all as specified and as directed.
27Taking down or up steel tubing and connections including cleaning for re-fixing or removal to store 15mm bore , complete all as specified and directed.
28Taking down or up steel tubing and connection s including cleaning for re-fixing or removal to store 20mm bore , complete all as specified and directed.
29S&F for Tube 'medium grade' galvanized, with all fitting and fixed complete to walls and ceiling etc 15mm bore, complete all as specified and directed.
30-ditto- all as item No 29 but 20mm bore.
31S&F Bib taps chromium plated fancy type, cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed in repair 15mm bore , complete all as specified and directed.
32S&F for wall mixer with provision of shower for mixing hot and cold water 3 in 1 fancy type brass chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed 15mm bore fixed.
33S&F 15mm angular stop cock with wall flange stainless steel/Brass chromium plated,screwed down high pressure with or without lathered hot and cold with long screwed shanks and fly nuts complete all as specified and directed.
34S&F for basin mixer, 2 in 1 , cast copper alloy, with capstan head chromium plated screwed down high pressure with or without lathered hot or cold with long screwed shanks and fly nuts screwed for iron pipe 15mm bore, complete all as specified and directed.
35S&F for PVC connection 15mm bore size with PTMT nuts of length 45cm, complete all as specified and directed.
36S&F as in repairs PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle including brackets. 10 ltr capacity, complete all as specified and directed.
37S&F in repair oval type with WHB counter type, size 550x400mm including complete fittings and fixtures complete all as specified and directed .
38S&F for fancy brass chromium plated shower rose 125mm fixed in repair , complete all as specified and directed.
39S&F in repair ball valve high pressure of PTMT with epoxy coated Aluminum rod & high density plastic ball screwed for iron pipe or brass ferrule and fixed in repair 20mm bore, complete all as specified and directed.
40S&F in repair 600x450mm beveled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and aluminium desiner frame fixed to with chromium plated brass screws and cup waste washer, complete all as specified and directed.
41S&F CP grating 150mm dia with centre hole , complete all as specified and directed.
42Disconnecting existing tanks, capacity exceeding 250 liters but not exceeding 500 liters setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (cleaning repairing, etc. measured separately), complete all as specified and directed .
43S&F Rotational moulded polythene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I 1000 ltr capacity incl dismantling water tanks and removing to store , complete all as specified and directed.
44S&F in repair for Gun-metal, globe or gate valves, for20mm bore dia of pipe in mm with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
45Supply and fixing in repairs vitreous China squatting pattern Orissa pattern WC size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) but including lime concrete bedding complete all as specified and as directed.
46S&F brass in repair chromium plated tubular towel rail 20mm dia(D) type 60cm long between flanges complete.
47S&F 32mm /40mm dia waste pipe for WHB,/urinals complete all as specified and directed.
48Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each, complete all as specified and directed.
49Taking down chokats or frames with shutters (without taking off shutters from frames) exceeding 1.5 Sqm but n.exc 4 Sqm each , complete all as specified and directed.
50M&L Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, size of frame 125x60mm, complete all as specified and as directed .
51Plain cement concrete M-10(1:3:6), type C-0, (using 12.50mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed.
52S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rein forced with M.S. square tube supplying and fixing in opening as per specification and drawing.
53Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter, jointed internally with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed.
54S&F for factory made steel ventilator, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter, jointed internally with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs, Galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and 3mm thick ordinary sheet glass pans with oil putty and clips etc, complete all as specified and as similar to shown in drawing No- CEUZ/TD-1517.15, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge.
55Supply and fixing of cupboard shutter 20mm thick (style) factory made panel PVC incl chowkat frame made out of m.s tubes 19 gauge for top and bottom rails m.s frame shall be covered with heated moulded plain colour PVC © channel having a PVC sheet strip of 10mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side 10mm (5mmx2) thick of 20mm and 20mm cross PVC sheet and as gap insert for top and bottom rail. Panelling for plain colour PVC sheet to be fitted in the m.s frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying fixing in the frame at site as per specification and drawing.
56S&F sheet glass ordinary quality and glazing with oil putty in square nexc 0.5 Sqm Each pane 3mm thick, complete all as specified and directed.
57Figured glass pin head type glazed with oil putty in square n-exc 0.5 Sqm in Each pane 4mm thick, complete all as specified and directed. .
58S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail lock rail and bottom rail and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded etc. with suitable PVC sheet beading including hinges etc complete all as specified.
59Factory made, 40 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
60Glazed and Skelton shutters using 2nd class hard wood 30mm thick open rebated and prepare to receive glass or gauge etc edges of framing plain and chamfered or fitted cut or mitered beads for securing glass size of member of shutter as specified in SSR Part-I section 8, clause 8.23(a) and divided in square complete all as specified.
61S&F for glavanised Mild steel wire cloth. 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvnaised wire staples, complete all as specified and directed.
62S&F of Framedwork such as grills, gratings, etc.; with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework/ caging of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed.
63M&L for MS flat iron 40x6mm and struts in fencing including cutting tops to shape as directed,drilling holes, Fe 290 gde E-165 complete all as specified. .
64Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed.
65Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome primer, complete all as specified and as directed .
66S&F aluminium anodised barrel tower bolt of extruded section and fixed, length of bolt 150mm, complete all as specified and directed.
67S & F Aluminum alloy, anodized sliding door bolt with hasp staple( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolt of extruded section or cast aluminium alloy 250 mm long , complete all as specified and directed.
68S&F extruded aluminum alloy handles 150mm size fabricated type anodized all as specified.
69300mm ordinary rat rail rod pattern spring including roller plate complete fixing mild steel spring, complete all as specified and directed.
70Floor doors stoppers of aluminium alloy body and tenque anodisede with hard drawn steel spring fixed in floor 150mm long, complete all as specified and directed.
71S & F Butt hinges, medium weight cold rolled stainless steel 100mm long to PVC Door etc, complete all as specified and directed.
72S&F epoxy powder coated pelmet rods of mild steel 25 mm with and including pair of fancy type finnals complete fixed as in repair, complete all as specified and directed.
73M&L for GI wire 6mm dia including fixing with straining bolt and nuts with hook and necessary PCC and form work for mosquoito net equal to length of barrack and 4 Nos line in each barrack , complete all as specified and directed.
74Demolition of brick built in cm including all quoins arches pillars etc, complete all as specified and directed.
75M&L Brick work with sub class 'B' bricks straight or curved in plane exc 6cm mean radius built in cm 1:6, complete all as specified and directed.
76Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
77M&L 15mm thick plastering on fair faces of bricks or cone surfaces finished even and smooth w/o using extra cement in cm1:6, complete all as specified and directed.
78M&L 5mm thick plastering on fair faces for cone surfaces finished even and smooth w/o using extra cement in cm1:3 on ceiling , complete all as specified and directed.
79M&L 15mm thick plastering on fair faces of bricks or cone surfaces finished even and smooth w/o using extra cement in cm1:4, mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed. (Note water proofing compound shall be measured and paid separately).
80Preparation of new surface of wall on plastering surface and applying two coat of oil emulsion white or coloured over a coat of primer of chalk wihiting or priming of OBD on walls complete all as specified and as directed.
81Complete all as above Item No 80 but in old surface, complete all as specified and directed.
82M&L for preparation of new surfaces of walls and applying two coats of cement based paint over one coat of primer complete all as specified and as directed
83M&L Preparing of new surface of plaster and applying three coats of white wash on ceiling completed all as specified and as directed.
84M&L Preparing of old surface of plaster and applying two coats of white wash on ceiling completed all as specified and as directed.
85M&L for Preparing new plastered wall and finishing to walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) , complete all as specified and directed.
86Dismantling of 100mm dia cast iron or reinforced concrete drain pipes, jointed in cement motar and taking out from floors or walls complete , complete all as specified and directed.
87Dismantling of 75mm dia cast iron or reinforced concrete drain pipes, jointed in cement motar and taking out of trenches , if required, complete all as specified and directed.
88S&F 100mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, complete all as specified and directed.
89S&F 100mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, in floors, complete all as specified and directed.
90S&F 75mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed.
91S&F 75mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, complete all as specified and directed.
92S&F bend (any radius ) with ducks foot or heel rest of 100mm bore, complete all as specified and directed.
93S&F bend (any radius ) with ducks foot or heel rest of 75mm bore, complete all as specified and directed.
94S&F branch pieces single ( equal or unequal, ordinary or inverted with parallel branch of bore 100mm, complete all as specified and directed.
95S&F branch pieces single ( equal or unequal, ordinary or inverted with parallel branch of bore 75mm , complete all as specified and directed.
96S&F Bends of 100mm diminishing pieces or tapers (larger bore measured), complete all as specified and directed.
97S&F Bends of 75mm diminishing pieces or tapers (larger bore measured), complete all as specified and directed.
98S&F branch pieces double ( equal or unequal, ordinary or inverted with parallel branch of bore 100mm, complete all as specified and directed.
99S&F 100mm dia CI P or S trap, complete all as specified and directed.
100S&F 100mm CI floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed.
101S&F 150 x 100 mm dia SWG Gully trap setting and jointing with cement mortar 1:1 complete all as specified and directed .
102Supply only Integral waterproofing compound
103Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil cimplete all as specified.
104M & L for hard core of broken stone guage n exc 63mm depositing spread and levelled in layers n exc 15cm thick watered and rammed to atrue surface .
105M&L 75 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate complete all as specified
106M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2021 of 60 mm thickness, M-35 grade with gray cement and pigment etc, complete all as specified and as directed by Engineer-In- Charge.
107M&L for sand (cushioning) filling under floors including watering and consolidation all as specified and as directed by Engr- in -charge.
108Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
109Pre-cast reinforced cement concrete 1:2:4 type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009), set in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
110TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engineer-In-Charge.
111Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; for laying electric cable, not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in soft/hard soil, complete all as specified and as directed by Engineer-In-Charge.
112Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm/200mm bore, set in cement mortar, complete all as specified and as directed by Engineer-In-Charge.
113Plain cement concrete M-10(1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge.
114Salt-glazed stoneware drain pipes, internal 150 mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-In-Charge.
115Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
116Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
117Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
118Plain cement concrete M-15(1:2:4), type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
119Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical/horizontal for crumple joint of surfaces/plith portion
120S&F in repairsVitreous China urinals, half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe
121S&F for Vitreous china urinal partition white of size 310x700 mm all as specified.
122Supply only Integral waterproofing compound .
123Taking down carefully copper/aluminium point wiring (light,fan,bell,socket or power, Sec light) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement for smooth finishing of holes,small patches etc complete all as specified and directed.
124Taking down unserviceable sub main wiring concealed type of any description along with PVC conduit including conduit accessories and made good the disturbed surfaces where ever necessary complete all as specified.
125Taking down U/S sheet metal enclosure concealed type with MCBs including making good the disturbed suface complete all as specified.
126Taking down Exhaust fan, dismantling blades, cleaning the same with cleaning material, re-assembling fan and blade, deposite Ex-Fan to MES store yard complete all as specified and directed.
127Taking down C/Fan, Seailing cable end, dismantling blades and removing fan and blades and deposite to MES store and re-fixing the same including provision of cable from ceiling rose or connector to fan and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed by Engr in Charge.
128Taking up/down old Under Ground cable of any size/type including complete all as specified and directed.
129Taking down of old U/S GI bracket set fixed on wall including making good the suface complete all as specified and directed. Please Enable Macros to View BoQ information
130Taking down of old U/S GI bracket set fixed on wall including making good the suface complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57052475
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 57.55 Lakhs
LAST DATE 14-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Bldg No P-04 (Otm Accn) And Allied Wks At 410 (I) Engrs Sqn At Akhnoor Mil Stn Under Ge (S) Akhnoor
Basic Detail
Tender No CWE/JA-21/2026-27
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 17 Aug 2026
Submission Date 14 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 57.55 Lakhs
Tender Fee 1000
EMD 1.11 Lakhs
Exemption Available
Document List
47ea4c1f-814b-424a-808f-17854f973782.html
BOQ_879270.xls
TENDER21.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

47ea4c1f-814b-424a-808f-17854f973782.html

xls

BOQ_879270.xls

pdf

TENDER21.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders