Tender For Upgradation Of Water Supply Distribution System At Industrial Estate Baramulla.
Tender Value
9.13 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
18 days left
EMD
18260
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Upgradation Of Water Supply Distribution System At Industrial Estate Baramulla.
BOQ
| Sl. No. | Item Description |
| 1 | Boring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800(part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipment tools plants and machineries required for the job, all complete as per direction of Engineer-in-charge upto 90 m depth below ground level. All types of soil 300 mm dia Rocky strata including boulders |
| 2 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and accessories etc all complete for all depths as per direction 50 TO 65 mm nominal size dia |
| 3 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/medium/coarse in required grading and sizes as per actual requirement all complete as per direction of Engineer |
| 4 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x450x50 mm reinforced with 8 mm dia four nos longitudinal and 9nos cross sectional T.M.T hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S flats of size 50mmx1.6mm complete all as per direction of Engineer-in-charge |
| 5 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socket/plain ended casing pipes of required dia, conforming to IS: 4270 of reputed & approved make, including painted with outside surface with two coats, of anticorrosive paint of approved brand and manufacture including required hire &labour charges, fitting and accessories, all complete for all depths, as per direction of Engineer-incharge. 125 mm nominal size dia having minimum wall thickness 5.00 mm |
| 6 | Development to tube well in accordance with IS: 2800(part 1) and IS:11189 to establish maximum rate of usable water yield without sand content ( beyond permissible limit) with required capacity air compressor, running the compressor for required time till well is fully developed measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete including required hire &labour charges of air compressor tools & accessories, etc. all, as per direction of Engineer-in-charge. |
| 7 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe removable as per requirement all complete for bore well of 100 mm dia |
| 8 | Providing and fixing M.S clamp of required dia to the top of casing/ housing pipe of tube well as per IS:2800 (part 1), including necessary bolts & nuts of required size complete 100 mm clamp |
| 9 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS: 2800 (part 1). 100 mm dia |
| 10 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 11 | SITC of 6.0 hp 3phase submerssible pump and motor assembly with started panel of approved make and brand including lowering of pump ,cable connections etc |
| 12 | P/L of 3 phase 10sqmm 3 core copper submerssible fixable cable |
| 13 | P/L of 3 phase 50sqmm 4 core copper fixable cable from main to starter panel |
| 14 | SITC 30 KVA servo voltage stablizer voltage range for 120-460 with 200 A AL bus BARwith main switch.Oil cooled with copper winding,MS sheet body,prime grade power coating,driven type motor insulation-class A,greater than 6 mega ohms micro processorbasewd digital control panel including all civil works complete |
| 15 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) carriages up to site of work complete65mm dia. nominal bore |
| 16 | S/F of 2hp motor of approved make of Crompton or havells with all necessary fitting complete job |
| 17 | Supply, installation, testing and commissioning of 3 phase energy meter complete with connection as required |
| 18 | Wiring for the following light points with 1.5Sqmm PVC insulated copper conductor 1100 volts grade standard flexible FRLS wires of approved make in concealed or surface mounted PVC conduit including providing and fixing of 6 Amp single pole rocker operated flush mounted switch of approved quality, color make and design in 1.6mm thick GI box and earthing of fixtures and the outlet box with 1.5sqmm PVC insulated copper conductor stranded flexible FRLS wire.a). One light controlled by 6 Amp Switch . |
| 19 | Wiring for 250 volts single phase and neutral 16 Amps switched socket outlet with 4 Sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in concealed or Surface mounted 25mm dia 2mm thick PVC conduit including providing and fixing of 16 Amps 3 pin switched socket of approved make and design in 1.6mm thick G1 boxes with grid plates and earthing the third pin of socket outlet with 4 Sq.mm PVC insulated copper conductor stranded flexible FRLS wire. |
| 20 | Supplying and installation testing and commissioning of following mccb,sa)10 to 32 amp mcbSp |
| 21 | b)40 to 63 amp DP |
| 22 | Supplying installation testing and commissioning ofchange over of approved make Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender