Housing Urban and Rular Development Local Bodies Closing in 2 days TDR #57050917

Tender For Ward No. Regarding Installation Of 200 Watt Led Light At The Public Place Situated Near Dukh Bhanjan Tekri Balaji Temple, Above Gol Nadi On Kila Road, 85.

Issued by Local Bodies · Jodhpur, Rajasthan
Tender Value
5 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
2 days left
EMD
10000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Ward No. Regarding Installation Of 200 Watt Led Light At The Public Place Situated Near Dukh Bhanjan Tekri Balaji Temple, Above Gol Nadi On Kila Road, 85.

BOQ

Name of Work:- वार्ड नं. 85 में किला रोड गोल नाडी के उपर दुख भंजन टेकरी बालाजी मन्दिर के पास स्थित सार्वजनिक स्थान पर चौक पर 200 वाट की एलईडी लाईट लगवाने बाबत्।
Sl. No. Item Description
1Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
2LED Street Light fixture with Minimum lumen output 25000 lm
3Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
410.0Sqmm
54 core
6Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
71 x 2.5 sq.mm
8S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
925 mm
10Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
11A) Excavation of Pit for Foundation Size upto required depth from Ground level
12B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.
13C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness
14D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.
15E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal
16F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.
17G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.
18H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.
19Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.
20Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
21Poles with Octagonal Cross Section
228 Mtr.
23Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
24Double arm overhang
25Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
26High Power LED Flood Light Minimum lumen output 18650 lm
27Providing & Fixing of ISO certified company made TP&N 415 V side handle operated double break fuse switch unit in sheet steel enclosure as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 (W/O HBC fuses) including making connections with suitable lugs, testing etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
2863 A rating
29Providing of IP66 protected High power LED Flood light system with pressure die cast housing,with suitable lenses on LED to achieve various beam angles,System lumen efficacy>=100lm/w,Drive shall be high efficiency having efficiency>85%c,CRI>70, Power factor>0.95, System life of 50,000 Burning Hours with 70% of Initial Lumens maintained.Light output in warm white.
30LED Flood Light 140W(Warm White)
31Supply & Installation of Unified Regulation System (URS) for existing street light that meets the following specification.The system must feature a 240MHz dual core processor with GSM/GPRS communication capabilities and support for OTA firmware updates.It should come with an internal class 1.0 energy metering system that can provide real time data of crucial electric load parameters along with fault and theft alerts.The URS must include remote load scheduling and control functionalities with a feedback time of less than seconds.the enclosure confirms to IP55 standards,and be fire retardant,weatherproof,and rustproof. The system should use a lightweight protocol for secure ,real-time communication and include cloud based software for comprehensive device management and remote control. it should be able to control single phase 5.5KW and 3 phase street light load upto 8.5KW and should come with 2pole/4pole MCB upto 25A/40A at output for short circuit protection .Having a 2-year warranty URS will be installed at site as per direction of engineering incharge. (Size 570*520*190mm) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57050917
AUTHORITY Local Bodies
TENDER VALUE 5 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Jodhpur Development Authority
Work Description Tender for Ward No. Regarding Installation Of 200 Watt Led Light At The Public Place Situated Near Dukh Bhanjan Tekri Balaji Temple, Above Gol Nadi On Kila Road, 85.
Basic Detail
Tender No JoDA/Nit-11/MLA-LAD/2026-27
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 17 Aug 2026
Submission Date 25 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value 5 Lakhs
Tender Fee 500
EMD 10000
Exemption Available
Document List
Binder1.pdf
BOQ_1047356.xls
ff9d08fe-9869-4756-8853-6c313aebb2c5.html
Tendernotice_1 (49).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
pdf

Binder1.pdf

xls

BOQ_1047356.xls

html

ff9d08fe-9869-4756-8853-6c313aebb2c5.html

pdf

Tendernotice_1 (49).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders