Chemicals and Fertilizers Government Departments Closing in 9 days TDR #57050587

Tender For Renovation And Repairing Of Cisf Barraks & Tsd(Process) At Fact-Cd, Ambalamedu.

Issued by Government Departments · Ernakulam, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
01 Sep 2026
9 days left
EMD
12000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Renovation And Repairing Of Cisf Barraks & Tsd(Process) At Fact-Cd, Ambalamedu.

BOQ

Name of Work:- Renovation and Repairing of CISF barraks & TSD(process) at FACT-CD, Ambalamedu.
Sl. No. Item Description
1Renovation and Repairing of CISF barraks & TSD(process) at FACT-CD, Ambalamedu.
2Dismantling/disconnection of existing DB and isolators from the CISF barraks, disconnection and removal of switch boards,DB, PVC duct in the technical service dept (TSD-process). The disconnected and dismantled materials shall be transported to the electrical workshop - PH1.
3Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 1.5 sq.mm copper red/yellow/blue/black/green wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco,KEI
4Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 2.5 sq.mm copper red/yellow/blue/black/green wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco,KEI
5Supply of 19/20mm medium type ivory coloured rigid ISI marked PVC electrical conduit with all accessories such as junction boxes, couplers, bends, tee, elbow ,G.I/PVC saddles, screws,wall/ceiling plugs etc. required for the surface conduit wiring.
6Installation of 1.5 sqmm copper wires. The installation scope shall include drawing of cables through rigid PVC conduits from switch board/JBs to light fittings/fan/plug points/junction boxes and termination of cables at the above points. Cables shall be jointed or tapped only at the junction box/switch boards. Care should be taken to see that not more than 6 cables are taken through a single conduit. The cables used for wiring circuit shall be standard colour pattern/ according to direction of site incharge.
7Installation of 2.5 sqmm copper wires. The installation scope shall include drawing of cables through rigid PVC conduits from switch board/JBs to light fittings/fan/plug points/junction boxes and termination of cables at the above points. Cables shall be jointed or tapped only at the junction box/switch boards. Care should be taken to see that not more than 6 cables are taken through a single conduit. The cables used for wiring circuit shall be standard colour pattern/ according to direction of site incharge.
8Installation of 19/20mm rigid PVC conduit wiring system. The installation scope shall include fixing of PVC conduits and its accessories to the walls / ceilings /columns etc. and neatly clamping at a uniform spacing of 400mm using GI saddles, providing suitable junciton boxes, drilling holes, minor civil work etc. The materials required for the installation such as GI saddles, screws, nuts and bolts, PVC Sbend, junction boxes etc shall be supplied by the contractor. The erection scope shall include, drilling holes, chipping ,plastering, minor civil works etc.
9Supply of Vertical DB (Double door IP52 or above) with accessories as per the following details Type: Surface mounting , Double door 3phase, 4way Protection: IP52 or above Incomer: 63 A,4P,MCB -1No. +36A,30ma,4p RCCB Outgoing 16A,1P,MCB -4no. 6A,1P,MCB-8nos, Busbar: 63/phase, fully insulated. Make: Legrand /equivalent
10Supply of Vertical DB (Double door IP43 or above) with accessories as per the following details Type: Surface mounting , Double door 3phase, 6way Protection: IP52 or above Incomer: 63 A,4P,MCB -1No. +36A,30ma,4p RCCB Outgoing 16A,1P,MCB -4no. 6A,1P,MCB-14 nos, Busbar: 63/phase, fully insulated. Make: Legrand /equivalent
11Installation of 3phase,4way, 415V, VDB. The scope of work include installation of VDB on the wall using slotted chanel/MS angle and anchor bolt, fixing all MCBs, wiring, dressing, connetion, cable glanding, gland earthing, cable termination,commissioning etc.The scope also include supply of hardwares and cable ties etc. required for the work.
12Installation of 3phase,6way, 415V, VDB. The scope of work include installation of VDB on the wall using slotted chanel/MS angle and anchor bolt, providing suitable cable entry box, providing \\"G\\" rail mounted connectors in the box, termination of Al-Cu wire termination, fixing all MCBs, wiring, dressing, connetion, cable glanding, gland earthing, cable termination,commissioning etc.The scope also include supply of hardwares and cable ties etc. required for the work.
13Supply of ceiling fan. The scope includes supply of BIS 5 star rated ceiling fan with following specification. Sweep:1200mm colour- white Regulator compatible
14Installation of Ceiling fan. The scope of work includes fixing ofthe ceiling fan below the false ceiling as directed by the site incharge. The materials required for the work including extending flexible cable, connectors etc are under the scope of contractor.
15Supply and erection of LED batten. The scope of work include supply of LED batten as per following specification and fix it on the wall, connection, testing of light fittings as directed by the site in charge. Supply of all materials required for the job including roun block are under the scope of contractor.Specification of LED batten: Input voltage- 140-270V, wattage 18W,Lumen2000lms, Efficacy >=110lms/W,CCT-6500K, CRI >=80, Mounting-surface Life- 1yr warranty, Power factor->0.9, Driver efficienty->85%
16Supply of surface mounting type downlighter including all accessories and having the following specifications: Power supply: 220-240V, 1 ph, 50Hz Colour: Cool day light efficacy : _> 100lm/w Luminous out put: 3600 - 3000 lumen size 1'x1' Life: Minimum 50k hrs Surge protection: up to 2.5 kV with wide voltage protection 160-360VThe fitting shall have no visible flickering, UV/IR and low glare to prevent eye strain OEM warranty: one year onsite.Make: Philips full glow G6 or equivalent
17Supply of recess mounting type downlighter including all accessories and having the following specifications: Power supply: 220-240V, 1 ph, 50Hz Colour: Cool day light efficacy : _> 100lm/w Luminous out put: 3600 - 3000 lumen size 1'x1' Life: Minimum 50k hrs Surge protection: up to 2.5 kV with wide voltage protection 160-360VThe fitting shall have no visible flickering, UV/IR and low glare to prevent eye strain OEM warranty: one year onsite.Make: Philips full glow G6 or equivalent
18Installation of downlighters. The scope of work includes fixing of 1'x1' surface mounting downlighters to the ceiling and providing power connections using suitable connectors and flexible copper wires. All accessories including suitable PVC connectors, fixing clamps/clips, screws shall be supplied by the vendor.
19Supply and installation of street light fittings. The scope of work include supply o fLED street light fittings as per following specification and installation of the same to existing pipe fixed out side of the building. Input voltage:-140-270V, Lumen 4000lms, efficacy >110lms/w CCT-6500K, CRI>-80, mounting pole(OD 50-60mm) Luminaire housing-Aluminium extrusion, rating-IP66, Life 1yr onsite warranty, Pf>-0.9, driver efficiency >-85%
20Supply of 6A 3 Pin plug Socket. Legrand Mylinc -regular white or equivalent
21Supply of 6A 3 Pin plug Socket. Legrand Myrius-regular white or equivalent
22Supply of 6A Switch 1 Way. Legrand Mylinc -regular white or equivalent
23Supply of 6A Switch 1 Way. Legrand Myrius -regular white or equivalent
24Supply of 6/16 A Socket. (2M) Legrand Mylinc - regular white or equivalent
25Supply of 6/16 A Socket. (2M) Legrand Myrius - regular white or equivalent
26Supply of 16A Switch 1 Way. (2M) Legrand Mylinc - regular white or equivalent
27Supply of 16A Switch 1 Way. (2M) Legrand Myrius - regular white or equivalent
28Supply of surface mount box with plate frame white 12 M. Legrand Mylinc regular white or equivalent
29Supply of surface mount box with plate frame white 12 M. Legrand Myrius regular white or equivalent
30Supply of surface mount box with plate frame white 8 M. Legrand Mylinc regular white or equivalent
31Supply of surface mount box with plate frame white 4 M. Legrand Mylinc regular white or equivalent
32Supply of surface mount box with plate frame white 4 M. Legrand Myrius regular white or equivalent
33Supply of surface mount box with plate frame white 3 M. Legrand Mylinc regular white or equivalent
34Installation of 12M switch box. The scope of work include fixing of boxes on wall, fixing of frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
35Installation of 8M switch box. The scope of work include fixing of boxes on wall, fixing of frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
36Installation of 4M switch box. The scope of work include fixing of boxes on wall, fixing of frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
37Installation of 3M switch box. The scope of work include fixing of boxes on wall, fixing of frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
38Supply of PVC (FRLS) cable duct of size 45 x 45 mm
39Installation of PVC cable duct. The scope includes fixing of PVC cable ducts on walls/concrete/wood etc. The materials required for fixing the duct is under the scope of contractor. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57050587
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 01-09-2026
Authority
Authority Name Fertilisers And Chemicals Travancore Limited
Work Description Tender for Renovation And Repairing Of Cisf Barraks & Tsd(Process) At Fact-Cd, Ambalamedu.
Basic Detail
Tender No 04026/2026-2027/E33998
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 17 Aug 2026
Submission Date 01 Sep 2026
Open Date 02 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 12000
Exemption Available
Document List
1f4aafee-9ddd-4b88-ae71-1f16443890bf.html
BOQ_969292.xls
ComplianceStatement.pdf
SpecialTermsandConditions.pdf
TenderDocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

1f4aafee-9ddd-4b88-ae71-1f16443890bf.html

xls

BOQ_969292.xls

pdf

ComplianceStatement.pdf

pdf

SpecialTermsandConditions.pdf

pdf

TenderDocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders