Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #57050534

Tender For Repair / Replacemnet Of Lt Panel Including Allied Works Of Water Supply Installation At Agra

Issued by Statutory Bodies & Commissions/Committees · Agra, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Sep 2026
14 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair / Replacemnet Of Lt Panel Including Allied Works Of Water Supply Installation At Agra

BOQ

Name of Work:- REPAIR / REPLACEMNET OF LT PANEL INCLUDING ALLIED WORKS OF WATER SUPPLY INSTALLATION AT AGRA
Sl. No. Item Description
1Supply, installing, testing & commissioning of LT starter panel of cubical indoor type 3 phase 4 wire bus bar chamber & aluminum bus bar of rating 1000 amps for phases and neutral with sleeves including panel wiring with totally enclosed,(CPRI approved) 1100 volts, AC supply, factory made fully compartmentalized made out of 2 mm thick CRCA steel sheet for load bearing and 2 mm thick for non-load bearing of size not less than 1800x1475x400mm and portions vermin proof, protection of enclosure IP:54 class protection complete with powder coating paint including suitable angle iron size 75x75x5mm for mounting stand with suitable configuration multi-function digital meter with CT & selector switches for measuring current, voltage, PF & indicating lamps for each phase including taking down old U/S LT panel with accessories complete all as specified and directed, comprising with the following MCCB/ ACB’s duly mounted and inter connected. (Note: -All Type Test Certificates and Design verification with switch gears (ACB & MCCB) as per confirming to IS:61439/2011 Part-1 and part -2, short circuit test 4000 AMP 65 KA. from CPRI shall be submitted by the contractor before executing the job.) INCOMER: -(a) MCCB 630 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 50 KA - 1NoOUTGOING: -(a) MCCB 350 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 36 KA - 3 Nos(b) MCCB 63 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 30 KA - 1 Nos(c) MCB 40A SPN 10kA – 03 Nos(d) Fully Automatic Star Delta Starter 150HP – 03Nos (each starter contains)(i) Contactor 300A 3 pole - 02Nos(ii) Contactor 250A 3 pole - 01No(iii) MPR protection relay (protection against Thermal, Overload, Earth Fault, single Phasing, Current unbalance, Phase sequence reversal, Locked Rotor, Under Current, LED's for trip indication for each fail safe) – 01No(iv) Add on Block 2NO-2NC – 03Nos(v) Star Delta Timer – 01No(vi) MCB 10A SP 10kA – 01No(vii) MCCB 250 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 25 KA -1NoMetering: -(a) Digital Volt meter 0-500 volt with selector switch with MCBs - 01 No(b) Digital Amp meter with selector switch of CT ratio 400/5 - 01 No(c) Indication lamps R, Y, B LED type with 3 Nos of 2A MCBs - 1 set(d) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.
2Supply, installing, testing & commissioning of LT starter panel of cubical indoor type 3 phase 4 wire bus bar chamber & aluminum bus bar of rating 1600 amps for phases and neutral with sleeves including panel wiring with totally enclosed, 1100 volts, AC supply, factory made fully compartmentalized made out of 2 mm thick CRCA steel sheet for load bearing and 2 mm thick for non-load bearing of size not less than 1800x1475x400mm and portions vermin proof, protection of enclosure IP:54 class protection complete with powder coating paint including suitable angle iron size 75x75x5mm flat iron frame work/supports with suitable configuration multi-function digital meter with CT & selector switches for measuring current, voltage, PF & indicating lamps for each phase including taking down old U/S LT panel with accessories complete all as specified and directed, comprising with the following MCCB & ACB’s duly mounted and inter connected. (Note: -All Type Test Certificates and Design verification with switch gears (ACB & MCCB) as per confirming to IS:61439/2011 Part-1 and part -2, short circuit test 4000 AMP 65 KA. from CPRI shall be submitted by the contractor before executing the job.) INCOMER: - (a) MCCB 630 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 50 KA - 1NoOUTGOING: - (a) MCCB 350 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 36 KA - 04 Nos(b) MCCB 63 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 30 KA - 01 Nos(c) MCB 40A SPN 10kA – 02 Nos(d) Fully Automatic Star Delta Starter 120HP – 04Nos (each starter contains)(i) Contactor 250A 3 pole - 02Nos(ii) Contactor 200A 3 pole - 01No(iii) MPR protection relay (protection against Thermal, Overload, Earth Fault, single Phasing, Current unbalance, Phase sequence reversal, Locked Rotor, Under Current, LED's for trip indication for each fail safe) – 01No(iv) Add on Block 2NO-2NC – 03Nos(v) Star Delta Timer – 01No(vi) MCB 10 A SP 10kA – 01No(vii) MCCB 250 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 25 KA -1NoMetering: -(a) Digital Volt meter 0-500 volt with selector switch with MCBs - 01 No(b) Digital Amp meter with selector switch of CT ratio 400/5 - 01 No(c) Indication lamps R, Y, B LED type with 3 Nos of 2A MCBs - 1 set(d) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.
3Supply, installing, testing & commissioning of LT starter panel of cubical indoor type 3 phase 4 wire bus bar chamber & aluminum bus bar of rating 400 amps for phases and neutral with sleeves including panel wiring with totally enclosed, 1100 volts, AC supply, factory made fully compartmentalized made out of 2 mm thick CRCA steel sheet for load bearing and 2 mm thick for non-load bearing of size not less than 1000x1275x400mm and portions vermin proof, protection of enclosure IP:54 class protection complete with powder coating paint including suitable angle iron size 75x75x5mm /flat iron frame work/supports with suitable configuration multi-function digital meter with CT & selector switches for measuring current, voltage, PF & indicating lamps for each phase including taking down old U/S LT panel with accessories complete all as specified and directed, comprising with the following MCCB & ACB’s duly mounted and inter connected. (Note: -All Type Test Certificates and Design verification with switch gears (ACB & MCCB) as per confirming to IS:61439/2011 Part-1 and part -2, short circuit test 4000 AMP 65 KA. from CPRI shall be submitted by the contractor before executing the job.) INCOMER: - (a) MCCB 250 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 50 KA - 1NoOUTGOING: - (a) MCCB 100 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 36 KA - 03 Nos(b) MCCB 63 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 30 KA - 01 Nos(c) MCB 40A SPN 10kA – 02 Nos(d) Fully Automatic Star Delta Starter 20HP – 03Nos (each starter contains)(i) Contactor 60A 3 pole - 02Nos(ii) Contactor 40A 3 pole - 01No(iii) MPR protection relay (protection against Thermal, Overload, Earth Fault, single Phasing, Current unbalance, Phase sequence reversal, Locked Rotor, Under Current, LED's for trip indication for each fail safe) – 01No(iv) Add on Block 2NO-2NC – 03Nos(v) Star Delta Timer – 01No(vi) MCB 10 A SP 10kA – 01No(vii) MCCB 160 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 36 KA - 01 NosMetering: -(a) Digital Volt meter 0-500 volt with selector switch with MCBs - 01 No(b) Digital Amp meter with selector switch of CT ratio 400/5 - 01 No(c) Indication lamps R, Y, B LED type with 3 Nos of 2A MCBs - 1 set(d) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.
4Supply, installing, testing & commissioning of LT starter panel of cubical indoor type 3 phase 4 wire bus bar chamber & aluminum bus bar of rating 400 amps for phases and neutral with sleeves including panel wiring with totally enclosed, 1100 volts, AC supply, factory made fully compartmentalized made out of 2 mm thick CRCA steel sheet for load bearing and 2 mm thick for non-load bearing of size not less than 1000x1275x400mm and portions vermin proof, protection of enclosure IP:54 class protection complete with powder coating paint including suitable angle iron size 75x75x5mm /flat iron frame work/supports with suitable configuration multi-function digital meter with CT & selector switches for measuring current, voltage, PF & indicating lamps for each phase including taking down old U/S LT panel with accessories complete all as specified ans directed, comprising with the following MCCB & ACB’s duly mounted and inter connected. (Note: -All Type Test Certificates and Design verification with switch gears (ACB & MCCB) as per confirming to IS:61439/2011 Part-1 and part -2, short circuit test 4000 AMP 65 KA. from CPRI shall be submitted by the contractor before executing the job.) INCOMER: - (a) MCCB 160 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 50 KA - 1NoOUTGOING: -(a) MCCB 63 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 36 KA - 03 Nos(b) MCB 40A SPN 10kA – 02 Nos(c) Fully Automatic Star Delta Starter 05 HP – 03Nos (each starter contains)(i) Contactor 32A 3 pole - 02Nos(ii) Contactor 25A 3 pole - 01No(iii) MPR protection relay (protection against Thermal, Overload, Earth Fault, single Phasing, Current unbalance, Phase sequence reversal, Locked Rotor, Under Current, LED's for trip indication for each fail safe) – 01No(iv) Add on Block 2NO-2NC – 03Nos(v) Star Delta Timer – 01No(vi) MCB 10 A SP 10kA – 01No(vii) MCCB 160 AMPS 4 pole suitable for 3 phase AC Supply,50 HZ, 36 KA - 01 NosMetering: -(a) Digital Volt meter 0-500 volt with selector switch with MCBs - 01 No(b) Digital Amp meter with selector switch of CT ratio 400/5 - 01 No(c) Indication lamps R, Y, B LED type with 3 Nos of 2A MCBs - 1 set(d) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.
5M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm size, buried directly in ground (earth pit not less than 3.25M deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to and including galvanized steel earth strip 32 x 6mm, including 40mm bore GI light grade protection pipe as earth lead strip connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150mm thick alternate layers of charcoal or cock dust & common salt 20mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) cover 50mm thick of precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) duly reinforced with 8mm deformed or twisted bars @ 100mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/loose soil and deposited the surplus soil to a distance n.exc 50mtr away from starting point complete all as specified and shown in electrical plate No 3 of MES standard schedule of rates 2009 Part-I all as specified and directed.
6S&F in replacement for XLPE unarmoured, LT 1100V grade (heavy duty) copper conductor cable 3 core 95 sqmm confirming to IS7098(Part-I) 1988, laid in existing RCC covered duct/Sub way/along wall/MS bracket. Note : The Cables shall be fixed to LT panel with suitable size brass/stain less steel cable glands, copper lugs and rate deemed to be included in rate quoted for respective item
7Supply, laying & testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade cross sectional area 50 Sqmm. 3.5 core Confirming to relevant IS including taking dwon old u/s cable, cable cover etc complete all as specified and directed by Engineer-in-charge. Note : The Cables shall be fixed to LT panel with suitable size brass/stain less steel cable glands, lugs and rate deemed to be included in rate quoted for respective item
8Supply, laying & testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade cross sectional area 185 Sqmm. 3.5 core Confirming to relevant IS including taking dwon old u/s cable, cable cover etc complete all as specified and directed by Engineer-in-charge. Note : The Cables shall be fixed to LT panel with suitable size brass/stain less steel cable glands, lugs and rate deemed to be included in rate quoted for respective item.
9Supply and fixing in replacment of Manual Changeover switch 630 Amps ,4 Pole, 415 Volt ,I-O-II operation supplied with bridging bars,extended shaft and IP65 pistol type handle with SS Enclosure and make electric connection complete all as specified and as directed.
10Supply and fixing in replacment of Manual Changeover switch 200 Amps ,4 Pole, 415 Volt ,I-O-II operation supplied with bridging bars,extended shaft and IP65 pistol type handle with SS Enclosure and make electric connection complete all as specified and as directed.
11Supply and fixing in replacment of Manual Changeover switch 125 Amps ,4 Pole, 415 Volt ,I-O-II operation supplied with bridging bars,extended shaft and IP65 pistol type handle with SS Enclosure and make electric connection complete all as specified and as directed.
12Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation etc for shaft, wells, cesspits, manholes, pier holes,taking out cable, etc not exceeding 10 sqm on plan and n exc 1.5m in depth and getting out, for each additional 1.5m or part therefore in depth beyond the first 1.5m in any type soil complete all as specified & directed by Engineer-in-Charge.
13M&L sand cushioning to PVC cable with river sand and punning to provide required cover complete all as directed by Engineer-in-Charge. (Note :- For the purpose of payment only punned thickness will be measured).
14Supply & laying Precast concrete cable cover class LV, Type 1, flat, size 250mm x 150mm x 40mm complete all as specified & directed by Engineer-in-charge.
15Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any soil complete all as specified & directed by Engineer-in-Charge.
16Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
17S&F in replacement for GI tubing of size 40 mm light grade with all fittings laid undur road for cable protection complete all as specified and directed by Engineer-in-charge.
18M & L for road cutting for laying of cable and making good after laying to match with surrounding area with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate for a depth of 30 cm from top and balance portion shall be filled with approved earth complete all as specified and directed by Engr-in-Charge.
19M&L for boring of holes under road, pavement, hard standing by trenchless technology using necessary machinery and labour for laying underground cable through Gi pipe 40 mm dia complete all as specified and directed by Engr-in-Charge at site.. Note : Pipes will be measured and paid separately. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57050534
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 07-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Replacemnet Of Lt Panel Including Allied Works Of Water Supply Installation At Agra
Basic Detail
Tender No 8012/1203/E8
Bidding Type Tender
Location
City Agra
State Uttar Pradesh
Key Dates
Publish Date 17 Aug 2026
Submission Date 07 Sep 2026
Open Date 14 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 60000
Exemption Not Available
Document List
37ce8fd0-b354-42eb-b861-53b9faf419f2.html
BOQ_879344.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

37ce8fd0-b354-42eb-b861-53b9faf419f2.html

xls

BOQ_879344.xls

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders