Agriculture Government Departments Closing in 8 days TDR #57050106

Tender For Special Repairs To Godown No. 1 To 5 Such As Servicing Of Rolling Shutters, Top And Bottom Ventilators Including Painting, Painting Of Walls Inside And Outside, Repairs To Road And Construction Of Labour Rest Room, Security Room, Static Ta

Issued by Government Departments · Kallakurichi, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Aug 2026
8 days left
EMD
94200
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kallakurichi → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Godown No. 1 To 5 Such As Servicing Of Rolling Shutters, Top And Bottom Ventilators Including Painting, Painting Of Walls Inside And Outside, Repairs To Road And Construction Of Labour Rest Room, Security Room, Static Tank Etc.., At Chinnasalem Warehouse.

BOQ

Name of Work:- Special Repairs to Godown No. 1 to 5 such as servicing of Rolling shutters, top and bottom ventilators including painting, painting of walls inside and outside, repairs to road and construction of Labour Rest room, Security room, Static tank etc.., at Chinnasalem Warehouse.
Sl. No. Item Description
1Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of P.C.C., depositing the debris in the low lying areas inside the campus as directed by the Engineer - Incharge.
2Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of R.C.C., depositing the debris in the low lying areas inside the campus as directed by the Engineer - Incharge.
3Clean removal of Cement plaster from walls and clearing the debris away from the site and depositing the same in the low lying areas as directed by the departmental officers.
4Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms at the site, etc., complete complying with standard specification and as directed by the departmental officers.
5Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.
6Supplying and filling in foundation, basement, etc with filing stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
7Supply and filling in foundation and basement with Red Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
8Providing, laying, spreading and compacting graded stone aggregates for Wet Mix Macadam with specified thickness, including premixing the materials with water at OMC in mechnanical mix plant, conveyance of mixed materials by tipper to site, laying in uniform layers using pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory soil compactor to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of MORTH Rev-5
9Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers - Mixing by mechanical means
10Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by mechanical means
11Providing expansion joint at 5mtr intervals across the flooring by cutting the grooves 6mm wide and full depth of concrete by contractors own mechanical means and filling the gap with polysulphide sealent and adding admixtures recron 3s for crackfree construction at the rate of 125 gms pack per 50 kg of cement with all lead, lift and other incidental works, etc complete and as directed by the Engineer-Incharge.
12Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
13Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
14Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
15Cement Concrete 1:2:4 (One Cement, Two crushed stone sand and Four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges, centering and shuttering but including Super Plasticiser, mixing charges for machine mix, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - machine mix
16For Foundation and Basement
17In Ground Floor up to 4.50m height
18Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
19Supplying and fixing colour coated galvalume profile sheets (Make- TATA/JSW) with the depth of 30 mm and pitch of corrugation 200 mm (Colour and shape of profile as approved by the Engineer-in-charge), 0.47 mm (TCT) total coated thickness (tolerance as per relevant IS code), material yield strength 550 MPa, galvalume AZ-150 GSM (both side inclusive) with regular modified polyester paint and coating of 20-25 micron RMP on exposed surface including primer and 7-10 micron epoxy coating on unexposed surface including primer. The sheet should be supplied in single length as shown in drawing or as desired by Engineer in charge and shall be fixed using stainless steel Hex cap headed self threaded drilling/ tapping stainless steel screws M6, 65 mm long with 3 mm thick EPDM seal and Stainless steel stitching screw of size 19X2.5 mm excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. All screw should be sealed with silicon sealant etc.., compete as per standard specifications and as directed by the departmental officers. (The old AC sheets / Galvalume sheets should be taken over by the contractor on buy back policy)
20Supplying assembling and Errection of Cantilever Trusses with Purlin for Rain Shelter arrangements for opening Rolling Shutters in Godown. There Candilever Trusses making with Mild Steel Hollow Tube Section of Size 50x50x2.50mm for bottom and Rafter members and cross members tie up with 25x25x2.50mm size of MS Square tube sections also the Two trusses tie up with 4 Nos of Purlins to a Length of 5.10m and size of 100x50x2.50mm Rectangular Section, the Purlins to be filled with required MS Cleat Angle, the roof shelter to be covered with Galvalume sheet of 0.47mm thick with required curved at the end of sheet and the rate inclusive of Cost of Materials like MS pipes, Angle, and Galvalume Roofing Sheet and required bolt and Nutts also including necessary masonry work to errected the candilever trusses the trusses and Purlins to be painted with two coats of synthetic enamel paint over one coat of Red Oxide Primer etc. Complete Complying with Standard Specification. ( The trusses and Roofing sheets should be got approved from the depatmental Engineers before use on Work.)
21Providing two legged scaffolding using 13-15cm dia casuarinas post of 4m over all length (3m length + 0.5m projection + 0.5m into the ground) the distance between two rows being 1.5m and the spacing of the post being 2.0m in both rows with two horizontal posts with 0.5m.Overlap on either side and braces at 2.0m center to center including longitudinal and transverse middle braces to step and providing platform with country wood planks of 40mm thick and 1m width etc., complete complying with standard specification.
22Upto 8.00m height
23Upto 8.00m to 10.5m height
24Brick work inCement Mortar 1:5 (One Cement and Five M.Sand) using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Engineer-incharge.
25For Foundation and Basement
26For Super Structure in Ground Floor
27Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
28Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
29Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers. 160mm dia PVC Pipe.
30Repairing and Servicing the existing damaged wooden / iron ventilators, etc.., including cost of replacing worn out materials labour charges etc., complete complying with standard specification.
31Replacing the existing damaged GI weldmesh with new of size 7.50 x 2.50cm of 10 gauge for Fixed Swing Ventilator to avoid the entry of Brids, the weld mesh should be fixed withTeak wood reepers of size 50mm x 25mm for required length alround the FSV and the Rate is inclusive cost of materials and all labour charges for removing the existing wOrnout wiremeshes etc., complete Complying with Standard Specification.
32Repairs and servicing the manually operated Rolling shutter of size 1.80 x 2.44m and replacing the Existing worn out spares like M.S tension spring, small lathe, empty pully and double ball bearing, locking arrangements and also servising the gear box and shutter for smoothe function and pull operation etc., including cost of replacing materials labour charges etc complete complying with standard specification.
33Supplying assembling fabricating and errecting the grill Gate of Size 8.00x1.80m using with GI rectangular pipe for outer frame of size 50mmx50mm and inner portion of gate fitted with square rod grill of size 16mm dia and also using with MS sheet of 18gauge for required size for Aesthetic apperance the design of gate got approved from the departmental Engineers before use on work etc. Complete Complying with Standard Specification.
34Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames, stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided. 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided 1no. Aldrop is provided at lock rail section in the door 2 Nos of 200mm handle are to be provided. One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters. at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf of size 1.00m x 2.10m.
35Fabricating, Supplying and fixing in position of steel sheeted windows ( Two Leaves) with the following specifications. Outer frames of windows made of ‘Z’ section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion ‘J’ section (F4B) of size 46x25x3mm at 2.28kg/m and shutter section of made of F7D of 33x25x3mm at 1.419 kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS Flat at 0.70kg/m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly. 2 numbers of Steel Offset Pivot hinges of size 3” and one number of handle-Cu.m-latch of special type made with 18x5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation. a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. each window shutter having an adjustable stay made out of 18 x 5mm at 0.70 kg/ m MS flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 200mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18x5mm at 0.70kg/m, welded to the shutter at two place equivalent from each from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS 7452/1990.The cost includes cost of all materials, labour charges and other incidental charges, etc., complete complying with standard specification and as directed by the departmental officers.
36Supplying and fixing fine polished cuddapah slab of 38 / 40mm thickness for cupboard arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed by the departmental officers
37Paving the Top of roof with Solar refelective ceramic tiles of approved quality and colour with a size of 305 x 305 x 7mm laid in Cement mortar bed in 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with water resistant tile epoxy grout for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the departmental officers before use on works)
38Flooring with ceramic tiles of size 305 x 305 x 6mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the departmental officers before use on works)
39Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors including thorough scrapping of old walls etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the departmental officers before use on works.)
40Painting Old wood work with Two coat of synthetic enamel ready mixed paint of approved quality and colour in all floors including thorough scrapping of old paint etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the departmental officers before use on works.)
41Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors including thorough scrapping of old paint etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the departmental officers before use on works.)
42Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the exising priming coat in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the departmental officers before use on works.)
43Painting the walls with two coats of cement paint over one coat of cement primer as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The colour and shade of the cement paint shall be got approved by the departmental officers before use of work).
44Colour washing two coats in all floors using best freshly burnt white shell lime and best quality of approved variety of colouring pigment including cost of lime, colouring pigments, fevicol type gum, brushes, scaffolding charges etc., complete complying with standard specification. Mineral colouring pigments not affected by lime should only be used (stainers and colour solutions should not be used.)
45Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers.
46Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications. The Frame should be fixed with cement mortar.
47Supplying and fixing in position Manhole Cover SFRC of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications
48Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making good the dismantled portion to the originalcondition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the departmental officers. before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level - 110mm dia.
49Supplying & filling 20 mm size Brick jelly for dispersion trench as directed by the Departmental officers Complying with standard specification
50Supplying & filling 40 mm size HBG stone jelly for dispersion trench as directed by the Departmental officers Complying with standard specification
51Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and redoing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the departmental officers before use on works).
52PVC 32mm dia Elbow
53PVC 32mm dia Tee
54PVC 32mm dia Coupler
55PVC 110mm dia Tee
56PVC 110mm dia Elbow
57Construction of INSPECTION CHAMBER following clear size 600 x 600mm including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of Clay burnt Bricks of size 9” x 43/8” x 23/4” with Class designation of 7.5 and Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.
58Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by the departmental officers before use on works. - Internal water supply above ground level.
59PVC pipe 32mm dia
60Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylumsheet cover with TW switch box and 5A FT switch with continuous earth wire connection of 1.5sq.mm copper wire for making good of the concealed portion with suitable colour for PVC concealed 8 light point / fan point (for electronic regulator)
61Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting
62Supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1metre down rod with fan clamp with side plates and cross arm of size 450mm (18\\")
63Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
64Supply and fixing of 30W LED street light fitting with LED (Higher end) with 25 mm dia. GI pipe (class B) with 1 no. 25 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting
65Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 2.5 sq mm copper wire with painting of suitable colour.
66Sub total
67GST in 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57050106
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 31-08-2026
Authority
Authority Name Tamilnadu Warehousing Corporation
Work Description Tender for Special Repairs To Godown No. 1 To 5 Such As Servicing Of Rolling Shutters, Top And Bottom Ventilators Including Painting, Painting Of Walls Inside And Outside, Repairs To Road And Construction Of Labour Rest Room, Security Room, Static Tank Etc.., At Chinnasalem Warehouse.
Basic Detail
Tender No 2234/2026/C1
Bidding Type Tender
Location
City Kallakurichi
State Tamil Nadu
Key Dates
Publish Date 17 Aug 2026
Submission Date 31 Aug 2026
Open Date 01 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 94200
Exemption Not Available
Document List
89211579-e33a-480b-b406-6ad87aa8b9f1.html
BOQ_835604.xls
CHINNASALEM_LSDOCUMENT.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

89211579-e33a-480b-b406-6ad87aa8b9f1.html

xls

BOQ_835604.xls

pdf

CHINNASALEM_LSDOCUMENT.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders