Tender For Nabard-Ridf Xxvii-Electrification Of Integrated Pack House For Fruits And Vegitables In Strawberry Parkat Munnar, Idukki District.-Electrification Works-General Electrical Work
Tender Value
37.05 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
9 days left
EMD
50000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Idukki → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Nabard-Ridf Xxvii-Electrification Of Integrated Pack House For Fruits And Vegitables In Strawberry Parkat Munnar, Idukki District.-Electrification Works-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | App. A-Electrification |
| 2 | 1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 3 | OD69110/2026-2027Wiring combined plug point together with the light point/ fan point/ exhaust fan point/ call bell point including 6 A 5 pin modular socket controlled by 6A one way modular switch in the existing switch board and giving connection to the phase,neutral and earth terminal with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable ( Green wire for earthing) etc as required. |
| 4 | 90.3.19.3Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture |
| 5 | OD69799/2026-2027Supply conveyance and installation of Vpor proof LED light fittings in the Coldstorage Philips make WT150LED 44F 6500PU 120 and giving connections etc asrequired. |
| 6 | OD69102/2026-2027Supply conveyance, installation, testing and commissioning the 17 W LED Mirror light fittings directly fixed on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required (Philips Ultron 17- Watt Wall Light (Cool White, Round, Metal) or its equivalent make. |
| 7 | OD69104/2026-2027Supply ,installation,testing and commissioning of 700lm pressure die cast housingBulk head with IP66 protection & IK 08 having efficacy not less than 105lm/Wand giving connection with 3 core flex wire as required |
| 8 | 90.15.4.2Supply Conveyance, installation, testing and commissioning of 36/40W LED streetlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coatedhousing,acrylic cover complete with THD less than 10%, power factor greater than0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Drivercompartment should be seperatly accessible for maintenance (LM 79&80 certificatesfrom NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 9 | 90.3.18.2Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bentto shape / cut and welded to shape and fixing the same to wall / parapet using clampsas noted along with each size, painting with 2 coats of synthetic enamel paint over acoat of zinc chromate primer, making good the damages, colour washing etc asrequired.32 mm dia with HG company fabricated clamps |
| 10 | 90.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as perIS 732 as required. |
| 11 | OD69117/2026-2027Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star ratedceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:sblades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copperwinding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Airdelivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD lessthan 10% including remote or electronic regulator unit for speed control and allremaining accesories including safety pin, nut and bolts , washers, temperature riseequal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm ,suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required |
| 12 | 90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mmsweep including plastering colour washing etc. as required. |
| 13 | OD69108/2026-2027Supply,conveyance, installation , testing and commissioning of 300/305 mm sweepLight Duty Exhaust fan in metal frame working on 230 V A/C in the existingopening, fixing necessary anchor bolts / bolt and nuts etc., as required includinggiving connections with the supplied wire along with the exhaust fan. |
| 14 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 15 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm |
| 16 | 1.21.3Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm |
| 17 | OD69119/2026-2027Supply and fixing 25 mm dia GI flexible conduit with accessories on surface of wallmaking good the damages etc as required |
| 18 | 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm |
| 19 | 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm |
| 20 | 1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm |
| 21 | 1.17.31 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x6 sq. mm |
| 22 | 90.6.4.53Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single corecopper conductor cables conforming to IS 694 part I 1990 in the existing surface /recess conduit as required including giving necessary connections of the followingsizes.10.00 sq.mm 3 Run |
| 23 | 90.6.4.54Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single corecopper conductor cables conforming to IS 694 part I 1990 in the existing surface /recess conduit as required including giving necessary connections of the followingsizes.10.00 sq.mm 4 Run |
| 24 | 90.16.1.2Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.65 mm copper conductor (12SWG) |
| 25 | 90.16.5.2Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.65 mm (12 SWG) |
| 26 | OD69109/2026-2027Supply and providing the following sizes of bolt and nut with washers on the existingMS box / earth bus etc. as required including drilling necessary holes as required.25 x6 mm brass bolt & nut |
| 27 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm) |
| 28 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 29 | 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 30 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch |
| 31 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 32 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet |
| 33 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet |
| 34 | 90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 35 | 90.12.7.41Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 36 | 90.12.7.29Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 50 sq mm with factory madeclamp |
| 37 | 90.12.39.22 Supply & laying of one number PVC insulated and PVC sheathed armouredcopper power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm |
| 38 | 90.12.10.4Supply & laying of DWC pipe in ordinary soil 0.75m below ground levelincluding excavation77/63 mm or nearest size |
| 39 | 9.1.32Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 10 sq. mm (25mm) |
| 40 | 9.1.33Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 16 sq. mm (28mm) |
| 41 | 9.1.22Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 1/2 X 50 sq. mm (35mm) |
| 42 | 90.11.1.18Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required4 way (8+12) - double cover TPN verticalDB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP42/43) |
| 43 | 90.11.1.11Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required6 way (8+18) - three phase double cover (IP42/43) |
| 44 | 90.11.1.20Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required8 way (8+12) - double cover TPN verticalDB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP42/43) |
| 45 | 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps |
| 46 | 2.13.3Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.100amps |
| 47 | 2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 48 | 2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 49 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 50 | 2.10.4Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 51 | OD69161/2026-2027Supply and installation of C R C A sheet steel, minimum thickness 1mmphosphatised and powder coated, dust and vermin proof FP enclosure onsurface/recess for independent mounting of MCB/RCCB/ISOLATOR |
| 52 | 90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor orwall mounting, dust and vermin proof, cubicle type MV panel board comprising ofthe following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assemblyas per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approveddesign and requirement, with front and rear access facility, bus bar chambers, hingeddoors for all switch gear compartments, earthing the doors using 4 sq mm braidedcopper conductor, providing necessary cut-outs for mounting meters, relays,indication lamps, bus bar interconnection etc, detachable covers for bus bar chamberand cable alley, powder coating the assembly after subjecting to 7 tank process etc asrequired. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted anglesetc shall not be used for the fabrication of panel assembly. The measurments will betaken the area of the complete sheets used for panel board including partitions,folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCAsheet, powder coated (excluding base frame) |
| 53 | 90.14.2.1Supply and providing 2mm SMC sheet as shrouding for bus interconnection /terminations etc. including required nut & bolt etc. |
| 54 | 90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panelboardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 55 | 90.14.4Supply and fabrication conveyance and installation of base frame of panel boardusing 75 x 40 mm rolled steel channel (ISMC) |
| 56 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel board |
| 57 | 90.14.6Supply and providing copper bus bars including finger type SMC bus bar supports inthe bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. asrequired. |
| 58 | 90.14.7Supply and providing copper earth bus in the panel board |
| 59 | 90.14.10.11Supply, conveyance and fixing the following types & current rated control gears& switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply inthe existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole,current limiting type MCCB with microprocessor based release with overload settingof 50 - 100% having adjustable OL & SC |
| 60 | 90.14.10.3Supply, conveyance and fixing the following types & current rated control gears &switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in theexisting panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, currentlimiting type MCCB having thermal setting range of 80 - 100% with thermalmagnetic release having adjustable OL |
| 61 | 90.14.11.13MCCB AccessoriesSupply and fixing rotary handle, External type (including BUChandle with door interlock ) in the existing MCCB of rating up to 250 A |
| 62 | 90.14.11.2MCCB AccessoriesSupply and fixing one number earth fault Relay up to 125A to200A with CBCT. |
| 63 | OD69139/2026-2027Supply and providing Red, Green, Black, Yellow, Orange colours LED indicators,AC/DC 22.5mm cut out dia |
| 64 | OD69140/2026-2027Supply and providing Blue colour LED indicator lamp, AC/DC, 22.5 cm cut out dia |
| 65 | OD69141/2026-2027Supply and fixing of digital type Multi function meter of 1 accuracy class with backlitLED display, built in selector switch for measuring all electrical parameters like V, A,F, PF 3 phase accuracy class 1 suitable for flush mounting complete as required |
| 66 | OD69142/2026-2027Supply, Installation, Testing and commissioning of 120/5 A, 5 VA, accuracy class0.5, Resin Cast Metering CT as required |
| 67 | OD69143/2026-2027Supply and providing spreader/terminal adapter kit extended terminal for 4 poleMCCB of rating 160A & 200A(8 pcs) |
| 68 | OD69144/2026-2027Supply and providing spreader/terminal adapter kit extended terminal for 4 poleMCCB of rating 125A(8 pcs) |
| 69 | OD69145/2026-2027Carrying out control wiring for panel with normal meters and indication lamps alonewith 650/1100 V grade PVC insulated stranded single core copper conductor cablesconforming to IS 694 part I 1990 for interconnecting the control devices/equipmentsincluding providing suitable size insulated sockets at the termination points orsoldered properly,providing numbering ferules for the proper identification of thewiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc asrequired.1.50sq mm wire single run |
| 70 | OD69148/2026-2027Supply and providing Danger 415 V, 150 x 100 mm aluminium anodised legendplates in the existing panel board as required. |
| 71 | OD69149/2026-2027Supply and providing Bus bar chamber, 100 x 40 mm aluminium anodised legendplates in the existing panel board as required. |
| 72 | OD69150/2026-2027Supply and providing Cable alley, 100 x 40 mm aluminium anodised legend plates inthe existing panel board as required. |
| 73 | OD69151/2026-2027Painting letters or figures of the size2.50 cm, 4 cm or 5 cm with enamel paint as identification mark to SB, DB, panel board etc |
| 74 | OD69152/2026-2027Supply and providing Class A (2mm thick )Elastomeric insulating mat conforming toIS 15652/2006 with maximum use voltage is 3.3 KV |
| 75 | OD69157/2026-2027Supply and providing 9 litre capacity Galvanized mild steel Fire bucket conformingto IS 2546-1974. The bucket shall be galvanized and painted with two coats of whitepaint on the inside and two coats of red paint on the outside.The handles and earsshall be painted with two coats of black paint.The word 'FIRE" shall bepainted in black centrally on the outside,its letters shall be 75 mm high andapproximately 12 mm thick.The bucket shall be water tight.The bucket shall be fixedon MS angle frame work/ wall bracket filled with fine sand . |
| 76 | OD69158/2026-2027Supply and providing First aid chart duly framed and placed in a conspicuous locationfor clear vision. |
| 77 | 7.10Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. platewith inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60cm long and fixing the same in ground as required |
| 78 | 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired. |
| 79 | 5.15Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connectionsetc. as required |
| 80 | 5.9Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as stripearth electrode, including connection/ terminating with G.I. nut, bolt, spring, washeretc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt& spring washer spaced at 50mm) |
| 81 | OD69137/2026-2027Providing and fixing 2 X 25 mm X 5 mm G.I. strip test joint for earthing system |
| 82 | 90.16.2.2Supply and laying of the following sizes ofB class GI pipe laid 0.6 m below ground level including excavating trench ofsuitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class) |
| 83 | OD69107/2026-2027supply and installation of dust and vermin proof,3 phase syntax meter board(GS MB-6535) and to fix KSEB meters, fuse units , CT etc as required including fixing it onwall, making good the damages colour washing etc. as required |
| 84 | OD69111/2026-2027Supplying and fixing 160A, HRC Fuse Base with HRC Fuse link with connections, inexisting meter board etc as required |
| 85 | OD69101/2026-2027Supply and installation of 100 A, 2 Way neutral links mounted on DMC/SMC base |
| 86 | OD69138/2026-2027Supply and providing iron hook for binding service wire |
| 87 | OD69116/2026-2027Supply and laying of Nylon transparent string for supporting service cable. |
| 88 | OD69154/2026-2027Charges for preparation Electrical scheme A3 size- First copy. |
| 89 | OD69155/2026-2027Copying charges for Electrical scheme A3 size additional coppy |
| 90 | APP B : SITC of 58.5 KVA DG Set with AMF Panel |
| 91 | OD69802/2026-2027Supply conveyance, installation, testing and commissioning of 58.5 kVA CPCB IV+Complied DG Set with ESCORTS Water Cooled Engine coupled with Three PhaseCROMPTON Brushless Alternator 415 V, 0.8 pf, 50 Hz , Standard control panelalong with standard accessories like diesel tank, Battery with Leads, Silencer &Acoustic Enclosure with the following featuresENGINEGenset Flywheel (Flywheel housing SAE suitable combination)Governor suitable for Fixed Speed Genset ApplicationStarter Motor, charging alternator and necessary wiringEngine mounted Oil Pressure sensorEngine mounted Temperature sensor Fuel filter & Air Filter and connectors Enginemounted oil filter and connectionsPusher fan with fan drive and necessary pulleysOne set of AVM pads are included and this is built along with the base frame-Mounts are suitable for genset application.Cooling package with its connections (with Radiator mounting) and auxiliary watertank12 V / 24 V Battery and Battery Leads, suitable AH as required for the engine,suitably sizedFirst fill of Lubricating OilFirst fill of CoolantALTERNATOR415V, 50Hz 1500, 4 pole 4 lead or 6 leads, Star formation, Brushless, IP 23, ClassF/H insulation, AVR controlled, Voltage regulation +/-1%, with necessary shortcircuit and overload protection, B20 foot mounting with IC01 cooling. Alternator ismounted on a common base frame and coupled directly to the Engine. Alternatorconfirms to IS ? 4722 or equivalent standards.ACOUSTIC ENCLOSUREAn acoustic enclosure of suitable size for the DG set to reduce the noise level to thetune of 75db at a distance of 1metre from the enclosure. The DG Set can be operatedfrom outside and monitored from outside. Easy to handle and store. In case the DGset has to be removed then panels can be easily removed for the removal of the DGSet. Inclusive of Exhaust silencer, necessary piping, exhaust bellows etc., should bepart of the enclosure. Structurally robust for transportation with necessary earthingconnection.FUEL TANKThis base frame contains the fuel tank also. The tank is provided with an intakebreather and fill filter. The level of the fuel tank is indicated with a fuel level gaugemounted on the monitoring panel with suitable ATS Panel for 58.5 kVA DG set.STANDARD CONTROL PANEL :Control panel is made of dust and vermin proof construction of CRCA 16SWG sheetsfor the body and the door and consists of the following, including suitable sizealuminium power cable termination arrangement for that rating for both incoming andoutgoing cables including Digital Ammeter and Voltmeter, Frequency Meter, DigitalDC Voltmeter for battery voltage, Tachometer, Hour meter, 1no: kwh meter,1no:Suitably sized MCB/MCCB with OC/SC releases, With necessary CTs formetering, Emergency Stop Push Button etc as required. |
| 92 | OD70976/2026-2027 Supply, conveyance and filling of good grade Diesel fuel. |
| 93 | 18.7.7Providing, laying, testing and commissioning of C class heavy duty M S Pipeconforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges,tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitableclamp or support frame and painting with two or more coats of synthetic enamelpaints of required shades complete as required:100mm dia |
| 94 | OD70975/2026-2027Supply and providing cladding for 100mm dia MS exhaust pipe using 50mm thickglass wool /mineral wool /rock wool density not less than 120Kg/m3 and aluminiumcladding (0.6mm thick). |
| 95 | OD70977/2026-2027Supply, laying and clamping of 1 no. 2.5 sqmm 12 core PVC/ XLPE insulatedarmoured control cables with copper conductors for working voltages up to andincluding 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I forXLPE spacing of clamps not exceeding 60cms, making good the damages , colourwashing etc. |
| 96 | APP C: SITC of Fire Fighting Works |
| 97 | 18.4.2(a) Supplying, installation, testing and commissioning of electric driven450lpm at35m Head |
| 98 | OD69804/2026-2027PUMP CONTROL PANEL Supply, installation, testing and commissioning of MotorControl Panel for Fire pumps incorporating starters and Switchgear suitable for themotor HP. The control panel shall be duly painted with 2 coats of anti-corrosiveprimer and Epoxy paint of Fire Red Color fabricated out 16SWG CRCA Sheet floormounted type with all accessories as required etc. complete with Control and Powerterminals, etc.with the following complete with all accessories as per Kerala StateElectrical Inspectorate Standards |
| 99 | 90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 100 | 9.1.32Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 10 sq. mm (25mm) |
| 101 | 90.16.1.2Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.65 mm copper conductor (12SWG) |
| 102 | 90.16.5.2Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.65 mm (12 SWG) |
| 103 | 18.22Providing and fixing of pressure switch in MS pipeline including connection etc asrequired |
| 104 | 16.8Providing and fixing in position the industrial type pressure gauges with gun metal /brass valves complete as required |
| 105 | 18.8.7Providing, laying, testing and commissioning of C class heavy duty GI pipeconforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp orsupport frame and painting with two or more coats of synthetic enamel paints ofrequired shades complete as required.100 mm |
| 106 | 18.8.6Providing, laying, testing and commissioning of C class heavy duty GI pipeconforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp orsupport frame and painting with two or more coats of synthetic enamel paints ofrequired shades complete as required.80 mm |
| 107 | 18.11.5Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 ratingwith bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers,gaskets conforming to IS 13095 of following sizes as required:100 mm dia |
| 108 | 18.14.5Providing,installation,testing and commissioning of non-return valve of followingsizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etcas required.100 mm dia |
| 109 | OD69808/2026-2027Supplying, installing, testing and commissioning of Bronze Ball valves with fittingsof screwed end type and with ISI mark. 25MM |
| 110 | OD69809/2026-2027AIR RELEASE VALVE - Supply, installation, testing and commissioning of Gunmetal Air Release valve 25 mm dia as per IS:14845 ISI Marked |
| 111 | 18.9.2Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal or stainless steel coupling of 63mm dia with cast iron wheel ISI markedconforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chainas required:Single headed stainless steel |
| 112 | 18.17.1Supplying and fixing first-aid Hose Reel with MS construction spray painted in postoffice red, conforming to IS 884 complete with the following as required.a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 asper IS:12585b) 20 mm nominal internal dia gun metal globe valve &nozzlec) Drum and brackets for fixing the equipments on wall.d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe andsocket.30 m |
| 113 | OD69810/2026-2027Supply Installation testing and commissioning of Fire fighting delivery hoses, allsynthetic fibre, circular wovan, jacketted, controlled percolating type 35.7 kg/sq cmburst pressure 22 kg/cm proof pressure 14 kg/sq cm working pressure, bearing IS8423/94 mark in 15 Mtrs, 63 mm inside coupled with atainless steel heavy duty hosecoupling instantaneous patterns pair of male and female parts, with ISI mark (IS 903)with 18 SWG copper duly wound to above hose. |
| 114 | 18.18.2Supplying and fixing 63 mm dia gun etal short metal branch pipe ith 20 mm nominalinteranal diameter size nozzle conforming to IS 903 suitable for Instantaneousconnection to Interconnect hose pipe coupling as required:Stainless steel (Grade 304 |
| 115 | OD69812/2026-2027Supply, Installation, Testing and Commissioning of Single door Hose cabinets toaccommodate one piece of hose pipes along with one pair of male and femalecouplings and one branch pipe. The cabinet is made up of MS/FRP sheet with glassfronted hinged doors and lock |
| 116 | 18.19.1Supplying and fixing fire brigade connection of cast iron body with gun metal maleinstantaneous inlet couplings complete with cap and chain as reqd. for suitable diaM.S. Pipe connection conforming to IS 904 as required:2 way-100 mm dia M.S.Pipe |
| 117 | OD69813/2026-2027Supply, installing, testing and commissioning of Y type strainers of the followingsizes complete with SS mesh, flanged end connections, GI nut & bolts, gasketsetc and made functional |
| 118 | OD69814/2026-2027Supply and fixing of Portable 4Kg ABC MAP 50%(Stored Pressure) Type FireExtinguisher. pressurized with dry nitrogen gas service pressure 15 bar. Design,construction and testing as per IS 15683 with Fire rating 3A 55B, Body Hydrotestedat 35 bar, Operating temperature -30°C to +60°C, Both internal &external surafce are pure polyester corrosion resistance powder coated with min DFT50 micron with standard accessories. Other certification CE and EN 3-7 & 8.Color band .Blue band of 25 mm width |
| 119 | OD69815/2026-2027Supply and fixing of Carbon-dioxide type fire extinguisher of 2.00Kg capacity, handwheel operated valve made out of brass conforming to IS 3224, In-built Pressurerelief device (Fusible plug and Rupture Disc Type) Design, construction and testingas per IS 15683 with fire rating 55B. operating temperature -30°C to+60°C, ISI marked CO2 cylinder conforming to IS 7285 Part 1 or Part 2 andPESO certified. Metal wire braided hose shall have minimum bursting pressure of250 Kgf/cm2 . Filled with CO2 gas having purity 99.7% complied with IS15222.Other certification CE and EN 3-7 & 8. |
| 120 | OD69816/2026-2027Supply and fixing of Carbon-dioxide type fire extinguisher of 4.5Kg capacity, handwheel operated valve made out of brass conforming to IS 3224, In-built Pressurerelief device (Fusible plug and Rupture Disc Type) Design, construction and testing as per IS 15683 with fire rating 55B. operating temperature -30°C to+60°C, ISI marked CO2 cylinder conforming to IS 7285 Part 1 or Part 2 andPESO certified. Metal wire braided hose shall have minimum bursting pressure of250 Kgf/cm2 . Filled with CO2 gas having purity 99.7% complied with IS15222.Other certification CE and EN 3-7 & 8. |
| 121 | OD69817/2026-2027Supplying, installing, testing and commissioning MAIN CONTROL PANEL of 2ZONE's capacity. The panel shall be micro processor based visual LEDindications for fire / fault alarms, single and should have stage alarm facility. Thepanel shall be fabricated with M.S.sheet with locking arrangement. 2 X 12V MF typebatteries provided for the backup power supply of panel. |
| 122 | 17.1.6FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying,installation, testing & commissioning fire alarm sounder with facility to makeannouncement, mounted in M.S. box (16 SWG) with hinged cover plate &suitable for operation with amplifier i/c line matching transformer etc. complete asrequired. |
| 123 | 17.1.3FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying,installation, testing & commissioning of manual call boxes of MS Constructionin surface/recess with stainless steel chain & hammer assembly Complete withglass and push button etc. as required. |
| 124 | 17.5.2CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarmarmoured cable, 600/1000V rated with annealed copper conductor having XLPEinsulation, steel wire armouring & FRLS outer sheath complete as required. |
| 125 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 126 | OD69819/2026-2027Supply & erection of Exit Way signages & Emergency Exit lights, LEDExit / Egress Edgelit lights with rechargeble battery, conforms to IS 9581-1981, 22SWG CRCA white powder coated housing, having input voltage of 230V 50Hz. |
| 127 | OD69820/2026-2027Supply & erection of Photo luminscent type signages with the following letters to be provided in wall for the safe movement of occupants towards and through theexits. Size 300 MM x 100 MM. FIRE STATION / HOSE REEL / FIREEXTINGUISHER |
| 128 | OD69821/2026-2027Supply & erection of Glow Sign Boardmade of 3mm thick PVC foam board for eachfloor 12\\" x 4\\" (Fire Lift, Passenger Lift, Electrical Duct, Fire Station, Main Stair, FireExit, Floor Display, & Pump Room, IN CASE OF FIRE BREAK GLASS |
| 129 | OD69823/2026-2027Supply & erection of 3mm thick PVC foam board Assembly Point sign board 16\\" x16\\" |
| 130 | OD69824/2026-2027Supply & erection of Fire Escape rout in each floor having size 12\\" x 16\\" made of3mm thick acrylic sheet with glass frame |
| 131 | OD70972/2026-2027Charges for preparation Electrical scheme A3 size- First copy. |
| 132 | OD70973/2026-2027Copying charges for Electrical scheme A3 size additional coppy |
| 133 | APP D : CCTV Works |
| 134 | OD70979/2026-2027Supply Configuration and fixing of 4MP Bullet IP Camera in suitable places andgiving connections etc. s required. Make CP Plus or equivalent. |
| 135 | OD70980/2026-2027Supply Configuration and fixing of Supply and configuration of 8 Channel 4K NVRgiving connections etc s required. Make CP Plus or equivlent |
| 136 | OD70981/2026-2027 Supply Configuration and fixing of 4 TB Hard Disk giving connections etc srequired. Make WD Purple or equivlent. |
| 137 | OD70982/2026-2027Supply Configuration and fixing of 4 Port PoE Switch giving connections etc srequired. Make TP Link or equivlent |
| 138 | OD70983/2026-2027Supply and fixing of 5 Port Giga Switch giving connections etc s required. Make DLinkor equivlent |
| 139 | 1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required1 run of Cable |
| 140 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conformingto IS 694 part I 1960 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.3 core 1.50 sq mm |
| 141 | OD70991/2026-2027Supply Configuration and fixing of Media Converter in suitble places and givingconnections etc s required. Make Syrotec or equivlent Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender