Tender for Construction Of Artificial Synthetic Turf Football Ground With Fifa Certification At Govt. College, Bhuna, Dist. Fatehabad.
BOQ
| Sl. No. | Item Description |
| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish as per direction of Engineer-In-Charge. |
| 2 | EXCAVATION :- Earth work in excavation by mechanical means (Hydraulic excavator) / manual means (exceeding 30 cm in depth, 1.5 m in width) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as per direction of Engineer-In-Charge. |
| 3 | EXCAVATION (FOUNDATION) :- Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 30 cm in depth), including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed by Engineer-In Charge. |
| 4 | BACKFILLING-EXCAVATED EARTH :- Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering as per direction of Engineer-In-Charge. |
| 5 | BACKFILLING -GOOD EARTH:-Supplying and consolidating of earth free from weeds, roots, pebbles and other foreign material including royalty and carriage and filling the earth wherever required in layers not exceeding 20cm in depth, consolidating each deposited layers using power road roller of min 8 Ton capacity including density testing of soil as per specifications complete as directed by Engineer-Incharge (only consolidated fill shall be paid). |
| 6 | Providing and laying as per the standard procedure, polypropylene fiber Geotextile separation barrier of min.200 GSM, complete as per manufactures specification and directions of EIC.No Separate payment for overlap is payble and overlapping will be done as per standard practices. |
| 7 | Providing, fixing and laying 100mm internal diameter perforated CPVC pipe (pressure >=10 kg/cm2) , including jointing,perforation & providing end caps, as per directions of Engineer-in-charge. |
| 8 | Supplying, filling and compacting stone aggregates of following sizes: Only compacted volume is taken for payment purpose. |
| 9 | 40mm nominal size |
| 10 | 20mm nominal size |
| 11 | 10mm nominal size |
| 12 | 6mm nominal size / Stone dust |
| 13 | Providing and laying in position cement concrete 1:3:6 [1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size] for all works excluding the cost of centering and shuttering |
| 14 | CONCRETE (M25) :- Providing and laying structural reinforced cement concrete work, machine batched and machine mixed, design mix M-25 grade cement concrete conforming to IS:456 at all heights and depth for construction of beams, columns, staircases chajja, roof slabs, facia, canopies, fins, porch, water tank etc. excluding the cost of centering, shuttering and reinforcement, including cost of staging, scaffolding, finishing, compaction, curing and mixing approved chemical admixtures (if required) conforming to IS 9103 in recommended proportions to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge complete in all respects, inclusive of cost of all labour, materials, tools, tackles etc. |
| 15 | Providing and laying Thermo-Mechanically Treated reinforcement bars of grade Fe 500D or more and as directed by engineer conforming to IS : 1786 latest revision or the latest relevent code for RCC work including placing , straightening, cutting, bending, placing in position and binding with binding wire and cement mortar cover block of all size all complete as per drawings , specifications & direction of engineer in charge. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 17 | Foundations, footings, bases of columns etc. |
| 18 | Suspended floors, roofs, landings, balconies and access platform etc. |
| 19 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 20 | STRUCTURAL STEEL (TUBULAR SECTION ) :-Steel work in built up tubular Hot finished type tubes ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying two coats of synthetic enamel paint of approved make and shade over a coat of primer, including welding and bolted with washers etc. complete. |
| 21 | STRUCTURAL STEEL (BUILT-UP SECTION ) :- Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and and applying two coats of synthetic enamel paint of approved make and shade over a coat of primer. |
| 22 | STRUCTURAL STEEL (Wnidow farmes):- Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including 2 coats of synthetic enamel paint and 1 priming coat with approved steel primer all complete. |
| 23 | STRUCTURAL STEEL (DOOR FRAMES) Using M.S. angels 40x40x6 mm for diagonal braces :- Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying two coats of synthetic enamel paint of approved make and shade over a coat of primer.(Using M.S. angels 40x40x6 mm for diagonal braces) |
| 24 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and ventilators using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. |
| 25 | Manufacturing , supplying and fixing retro reflective sign board made up of 4 mm thick Aluminium Composite panel sheet, face to be fully covered with retro reflective sheeeting in any colour combination as decided by EIC including subject matter, message (bilingual) , symbols and border etc. pasted on substrate by an adhesive backing complete as per direction of EIC. |
| 26 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire & nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm PVC coated to achieve outer dia not less than 5 mm in required colour and shade. |
| 27 | M.S SLIDING DOOR BOLT :- Providing and fixing 300x16 mm oxidised M.S. sliding door bolts with nuts and screws etc. complete : |
| 28 | BRICK MASONRY (CLAY BURNT BRICKS) :- Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Cement mortar 1:6 (1 cement : 6 coarse sand) at all heights and depths laid to proper position line, level as per the drawings and specifications including providing necessary scaffolding, staging, raking out of joints, curing etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. |
| 29 | Ceramic Floor Tiles :- Providing and laying branded (Kajaria,NITCO,Johnson or Somany) Ceramic floor tiles conforming to IS : 15622 of approved make in all colours and shades laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with cement slurry including pointing as per directions of Engineer-Incharge. |
| 30 | Ceramic Glazed Wall Tiles :- Providing and fixing ceramic glazed wall tiles conforming to IS: 15622 of approved make, in all colours and shades of any size as approved by Engineer-in-Charge, in walls, skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry including pointing in white cement mixed with pigment of matching shade complete. |
| 31 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment).24 |
| 32 | PAVER BLOCK (M-30) :- Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 33 | Providing and fixing 20mm thick black Granite stone plaque of required size engraved with specified text, NPCIL logo, etc. inside a decorative border and inscription coated with indelible ink/paint all complete as per direction of EIC. |
| 34 | 15MM CEMENT PLASTER :- Providing 15 mm thick cement plaster 1:4 (1 cement : 4 coarse sand) with sand and cement mortar in drains including raking out joints, with finished coat of neat cement punning including curing etc. inclusive of cost of all labour, materials etc., complete as per direction of Engineer-In-Charge. |
| 35 | 6MM CEMENT PLASTER :- Providing 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) with cement mortar to soffits of slab, sides of beams, columns faces and all exposed concrete surfaces at all heights, roughening of concrete surface including rounding off and chamfering corners if required, curing etc. complete as per specifications. |
| 36 | WALL PUTTY :- Providing and applying cement based wall putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 37 | OIL BOUND DISTEMPER- Distempering with oil bound washable distemper of approved brand to give an even shade on New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 38 | ACRYLIC SMOOTH EXTERIOR PAINT :- Finishing walls with Acrylic Smooth exterior paint of required shade on New work as per manufacturer's specifications (Two or more coat and including priming coat of exterior primer). |
| 39 | SYNTHETIC ENAMEL PAINT :- Painting with synthetic enamel paint of approved brand and manufacture to give an even shade with Two or more coats on new work after application of primer coat. |
| 40 | CEMENT BASED WATER PROOFING :- Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with waterproofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d)Finishing the surface with 20 mm thick joint less cement mortar of mix1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 41 | RECTANGULAR CHINA CLAY BASIN:-Providing and fixing white vitreous china wash basin size 630X450mm (H&R JOHNSON' or equivalent in 'HINDWARE,' 'PARRY, CERA) with a single 15mm C.P.brass pillar tap (of jaquar CLARION/ CONTINENTAL or eqivalent qulaity of MARK/ HINDWARE) with C.I. brackets, Pedestal, 32mm C.P. brass waste of standard pattern , including painting of fittings and brackets , cutting and making good the walls wherever requird. |
| 42 | W.C. PAN :- Providing and fixing white vitreous china orissa pattern W.C.Pan (OP 23 of H&R Johnson or equivalent in HINDWARE /PARRY /CERA ) of Size 580X440mm with integral type foot rests (Indian type W.C. Pan) with 100mm sand cast Iron P or S trap,10 litre low level white P.V.C. flushing cistern , including bflush pipe , with manually controlled device (handle lever) confirming to IS : 7231, with all fittings and fixture complete,including cutting and making good the walls and floors wherever required. |
| 43 | SOAK PIT:- Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100mm diameter, 1.8m long complete as per standard design: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 and providing adequate manholes and layign arrangements for sewage pipelines. (manhole and pipeline to be paid in relevent items) |
| 44 | URINAL (Single half stall urinal with 5 litre P.V.C. automatic flushing cistern) Providing and fixing white vitreous china flat back urinal of size 580x380x350 mm, with white PVC automatic flushing Cistern , standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass , including urinal partition , flushing system and painting of fittings and cutting and making good the walls and floors wherever required. |
| 45 | BRASS BIB COCK:-Providing and fixing 15 mm nominal bore C.P. brass bib cock/ long nose bib cock of approved brand as per directions of EIC. |
| 46 | BRASS STOP COCK :-Providing and fixing 15mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make confirming to IS:8931 |
| 47 | 20MM CPVC PIPE CONCEALED:-Providing and fixing 20mm nominal dia.m nominal bore Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,i/c fixing the pipe with clamps as required. This includes jointing of pipes & fittings with one step CPVC solvent and the cost of cutting chases and making good the same including testing of joints complete as per direction of Enginner in Charge: Concealed work, including cutting chases and making good the walls etc. |
| 48 | 25MM CPVC PIPE EXPOSED :- Providing and fixing 25mm nominal dia. Pipes Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply , including all CPVC plain & brass threaded fittings , including fixing the pipe with clamps at 1.00mtr. spacing. This includes jointing of pipes & fittings with one step CPVC solvent cemnet and testing of joints complete as per direction of Enginner in Charge.Internal work -Exposed on wall. |
| 49 | 110MM UNPLASTICIZED SINGLE SOCKETED PVC RAIN WATER PIPE:- Providing and fixing on wall face 110 mm diameter unplasticised Single socketed Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap, for thermal expansion, necessary fittings(Bends, Tees, Joints ,Traps,Elbows,clamps) and other accessories, as required |
| 50 | BEVELED EDGE MIRROR :-Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 51 | PVC WATER TANK :-Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Note-1. 4 nos. of tank 500ltr. capacity each. |
| 52 | BORE BALL VALVE :-Providing and fixing 25 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 53 | 300MM RCC NP02 PIPES-Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe |
| 54 | 450MM RCC NP02 PIPES-Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 450 mm dia. R.C.C. pipe |
| 55 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 750 x 600x50 mm, reinforced with 8 mm dia 5 nos longitudinal & 7 nos cross sectional T.M.T. hoop bars, including providing 40 mm dia perforations @ 100 to 125 mm c/c, all as per direction of Engineer-in-charge. |
| 56 | BRICK SOILING :-Providing and laying 150 mm thick Brick soling under floors using 25 mm to 115 mm common burnt clay FPS (Non modular ) bricks of class designation 7.5, filling interstices with spalls and binding material consolidating to required gradient and camber ,spreding ,watering etc. complete as per drawings ,specifications and direction of enginner. |
| 57 | CC CHEQUERED TILES :- Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath& courtyard , jointed with neat cement slurry mixed with Light shade pigment using white cement to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) . |
| 58 | GRANITE WORKS (Area of slab upto 0.50sqm):- Providing and fixing 18 mm thick gang saw cut Granite of any colour and shade, mirror polished, premoulded and prepolished , machine cut for kitchen platforms vanity counters , window sills and ventillator sill ,facias and similar locations of required size , approved shade ,colour and texture laid over 20 mm thick base cement morter 1:4 (1 cement : 4 corase sand ) joints treated with white cement , mixed with matching pigment, including rubbing , curing , moulding and polishing to give high gloss finish etc. complete at all levels. |
| 59 | LIQUID SOAP DISPENSER: Providing and fixing the following washroom fittings, PTMT liquid soap container (spring loaded push type) with lid and brackets fixed to PVC cleats with C.P. brass screws etc. complete in all respects, inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and direction of EIC. |
| 60 | TOILET PAPER HOLDER: Providing and fixing the following No's washroom fittings, CP brass Toilet Paper Holder approved equivalent make, inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and direction of EIC. |
| 61 | GLASS SHEIF:- Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 62 | TOWEL RAIL:-Providing and fixing min. 600 mm lengh satinless steel , standard size (ACN-CHR-1111SM or equivalent) wall mounted towel rail including all other accessories complete as per direction of EIC. |
| 63 | DEMOLISHING RCC:- Demolishing R.C.C. work in existing building structures at all heights and depths using pnuematic tools or chemicals or core cutter as approved by Engineer-in-charge including following all safety requirements, ensuring adequate precaution to the neighbourhood structures & equipment, putting necessary cover, stacking of reinforcement bars and disposal of unserviceable material within station area limit all complete as directed by Site Engineer.Note:-1. Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained.2. Providing of necessary covers/barricades around the work area is to be done prior to dismantling operations.3.Cutting of all reinforcement shall be done using hack saw or chisiel or any other method as approved by Engineer-in-charge. |
| 64 | DEMOLISHING PCC:- Demolishing P.C.C. work in existing building structures at all heights and depths using pnuematic tools or as approved by Engineer-in-charge including following all safety requirements, ensuring adequate precaution to the neighbourhood structures & equipment, putting necessary cover, and disposal of unserviceable material within station area limit all complete as directed by Site Engineer.Note:1. Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained.2. Providing of necessary covers/barricades around the work area is to be done prior to dismantling operations |
| 65 | DEMOLISHING BRICKWORK:- Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 66 | DEMOLISHING STRUCTURAL STEEL WORKS:- Dismantling of structural steel consisting of frames/built up sections in angles, tees, flats, tubes, plates, Joists, channels,, struts, bars etc. at all heights and depths as directed including cutting, welding/rivets. etc., following all safety requirements, ensuring adequate precaution to the neighbourhood structures & equipments, putting necessary cover, dismembering & stacking of all serviceable materials and disposal of unserviceable materials within station area limit as ditrected by Site Engineer inclusive of all labour, material, tools etc. complete.Note:-1. Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained.2. Providing of necessary covers/barricades around the work area is to be done prior to dismantling operations.3. Cutting of all steel shall be done using hack saw or any other method as approved by Engineer-in-charge. |
| 67 | Supplying and fixing movable type football goal post of size 7.32m x 2.44m (inside clear size) made of 100mm dia heavy duty MS pipe with epoxy paint of approved brand with back supports made of 40mm dia MS pipe with epoxy paint , fully welded corner joints including fixing Co Polymer wheels complete as per directions of Engineer-Incharge.NOTE: 1. The goal post should have special net lock made of PVC for hanging the net. 2. The goal post shall be made in accordance with FIFA approved design and specifications. |
| 68 | Supply and Installation of synthetic football turf having 50mm pile height with UV resistance from FIFA Preferred Producer conforming to FIFA Quality Standard as per their Latest Technical Specification, including SBR Rubber granules & Silica Sand infilling, as per manufacturer’s recommended quantities, unloading and staging of rolls, sewing of seams, infilling with appropriate dispensing, spreading and leveling equipment, brushing of fibers with all poly hydraulic controlled equipment, painting and marking of any lines as per FIFA guidlines if any with approved synthetic turf paint including Field Testing and certification by FIFA.1. No seperate payment for testings and overlab shall be payble.2.No seperate payment for Termination of turf with the RCC drains.3.The work will be done as per FIFA /industry standards with approval of Enginner-In-charge(EIC). |
| 69 | Wiring for light point/ fan point/ exhaust point/ call bell point with 1.5 sqmm FRLS PVC Insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C ( single controlled) |
| 70 | Wiring for group controlled (looped) light point/ fan point/ exhaust point/ call bell point (without independent switch etc.) with 1.5 sqmm FRLS PVC Insulated copper conductor single core cable in surface / recessed PVC conduit and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 71 | Supplying and fixing of 8 way double door, single pole and neutral, STEEL sheet, MCB distribution board, 240V on surface or recess, complete with tinned copper busbar, neutral bus bar, earth bus bar, Din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) |
| 72 | 25 A rating, 2 pole RCCB, 30 mA sensitivity. |
| 73 | 10 A rating, SPN, MCB \\"C\\" Curve, 10 kA breaking capecity |
| 74 | Wiring for circuit/submain wiring alongwith earthwire with the following sizes of FRLS PVC insulated copper conductor, single core cable in Surface/Recessed medium class PVC conduit as required. 2 x 4 +1 x 4 (E) sq. mm. |
| 75 | Supply and installation of 40W LED batten, 230V, 50Hz, with output of 4200 lumens and system efficacy of 105 lumne/watt surface/ recess mounting tube light with fitting and all other accessories. Similar to philips make Endureld batten BN108CLED40SPSUCDLWH or as per EIC instruction. |
| 76 | Supply and installation of 20W LED batten, 230V, 50Hz, with output of 2100 lumens and system efficacy of 105 lumne/watt surface/ recess mounting tube light with fitting and all other accessories. |
| 77 | Supply and installation of air exhaust fan of light duty, 230 volts(AC) 200mm sweep, plastic body, with louvers. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender