Tender For Waterproofing Of Buildings In Gail Vijaipur Plant Premises And Township
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Sep 2026
12 days left
EMD
5.42 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Guna → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Waterproofing Of Buildings In Gail Vijaipur Plant Premises And Township
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing CC: Demolishing cement concrete, brick work, brick bat, foam concrete by manually/ mechanical means Including removal of existing waterproofing / APP membrane, including stacking of serviceable material along with disposal of material at any lead and level as per the direction of Engineer-in-charge. |
| 2 | Dismantling Plaster: Dismantling old plaster or skirting raking out joints and cleaning the surface including removal of existing waterproofing / APP membrane including disposal of rubbish to the dumping ground within GAIL plant premises at any lead and level as per direction of Engineer-in-charge. |
| 3 | Cement Concrete: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) at all level and depth as per the direction of Engineer-in-charge. |
| 4 | Brickbat Waterproofing: Providing and laying integral cement based BrickBat Coba layer With average thickness of 120 mm and minimum thickness at khurra as 65 mm consisting of following operations:1. Applying a slurry coat of neat cement using 2.75 kg/sqm of cment admixed with water proofing compound over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.2. Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.3. After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound.4. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.5. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order, confirming to IS 2645 and as directed and specified by the Engineer-in-Charge |
| 5 | Water proofing material: Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (EA = qty. used for per 50 kg cement bag.) as per the direction of Engineer-in-charge. |
| 6 | Cement Plaster 12mm: Providing and laying 12 mm thick cement plaster of mix : 1:4 (1 cement: 4 fine sand) at all level and depth as per direction of Engineer-in-charge |
| 7 | Cement Plaster 18mm: Providing and laying 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) at all level and depth as per the direction of Engineer-in-charge. |
| 8 | Crack Repair: Making V grove of 5 mm wide and 5 mm deep over crack line, cleaning the grove and sealing of prepared V grove with solvent free, moisture tolerant, thixotropic, two part structural adhesive and epoxy repair mortar cum surface levelling mortar . The compressive strngth of mortar shall be >= 60 N/mm2 and bond strength >=10 N/mm2. (Make: NitoMortar S Fosroc/ Sikadur -31 of SIka or equivalent) complete as per direction of EIC. |
| 9 | Waterproofing Coat:1. Surface preparation prior to waterproofing application as per detailed technical specification.2.Providing and applying one coat of PU/Epoxy based primer of approved make (Asian Paint Smart Care/Berger Home Shield/Nerolac Perma/Sika) as per product specification.3. Providing and applying first coat of PU based waterproofing liquid membrane of approved make (Asian Paint Smart Care/Berger Home Shield/Nerolac Perma/Sika) as per product specification.4. Providing and fixing of corner joint tape of approved make (AsianPaint /Berger/Nerolac Perma/Sika) as per product specification.5. Providing and applying second coat of PU based waterproofing liquid membrane of approved make (Asian Paint Smart Care/Berger Home Shield/Nerolac Perma/Sika) perpendicular to first coat as per product specification.Work to be executed as per product specs. and direction of EIC.The product may be applied in both vertical surface (wall/parapet) and horizontal surface (roof/chhajja/shade, etc.) as per requirement and as per technical specs. without any extra payment.Note: All the above-mentioned products must be of same make. E.g. Primer+ Waterproofing coat must be of same brand.\\" |
| 10 | UPVC pipe 110 mm Dia: Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter. including removal of old Rain water pipe if required, as per direction of Engineer in charge. |
| 11 | Gola: Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75 mm deep chase as per direction of Engineer-in-charge. |
| 12 | Khurra: Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. as per the direction of Engineer-in-charge. |
| 13 | Weather Silicon Sealant: Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender