Tender For Construction Of Faecal Sludge Treatment Plant (Fstp) Of Capacity 6Kld At Seraikella Nagar Panchayat And Operation And Maintenance Of Fstp For 5 Years
Tender Value
4.06 Crore
Estimated cost
Bid Submission
08 Sep 2026
8 days left
EMD
4.06 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Saraikela Kharsawan → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Faecal Sludge Treatment Plant (Fstp) Of Capacity 6Kld At Seraikella Nagar Panchayat And Operation And Maintenance Of Fstp For 5 Years
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.Ordinary rock |
| 2 | Hard rock (requiring blasting) |
| 3 | Excavation in Soil using Hydraulic Excavator and Tipperswith Disposal upto 1000 metres. |
| 4 | Filling in foundation trenches & plinth in layers not exceeding 150mm thick, well watered, rammed, fully compacted & fine dressed with earth obtained from excavation of foundation within a lead of 50m & lift of 1.50m all complete as per buiding specification and direction of E/I |
| 5 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 6 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 7 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge |
| 8 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 9 | Providing PCC in nominal mix of 1:3:6 in foundation with approved quality of stone chips with 20mm to 6mm size graded and clean coarse sand of FM of 2.5 to 3 including screening , shuttering, mixing cement concrete & placing in position , striking, vibrating, curing, taxes & royalty all complete as per building specification & direction of Engineer in charge |
| 10 | Providing PCC in nominal mix of 1:2:4 in foundation with approved quality of stone chips with 20mm to 6mm size graded and clean coarse sand of FM of 2.5 to 3 including screening , shuttering, mixing cement concrete & placing in position , striking, vibrating, curing, taxes & royalty all complete as per building specification & direction of Engineer in charge |
| 11 | Providing PCC in nominal mix of 1:4:8 in foundation with approved quality of stone metal grade -III( with 50mm to 25mm) size and clean coarse sand of FM of 2.5 to 3 including screening , shuttering, mixing cement concrete & placing in position , striking, vibrating, curing, taxes & royalty all complete as per building specification & direction of Engineer in charge |
| 12 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 13 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern |
| 14 | Cast-in-Situ Cement Concrete M20 Kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) |
| 15 | Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed material to work site, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401for grading - III material |
| 16 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechnical plant carriage of mixed material by tipper to site , for all leads & lifts, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. |
| 17 | Providing and laying bituminous macadam with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site , laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction |
| 18 | Providing and laying bituminous macadam with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed stone aggregates of specified grading premixed with bituminous binder@ 5.4 to 5.6% of mix and filler, transporting the hot mix to site , laying with a hydrostatic paver finsher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory & tandom rollers to achieve the desired compaction as per MORTH specification clause No 509 complete in all respects.for grading -I (13mm nominal size) |
| 19 | Providing and laying in position specified grade of reinforced cement concrete..All work upto plinth level excluding cost of centering, shuttering finishing and reinforcement:1:1.5:3 ( 1cement : 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size) |
| 20 | Reinforced cement Concrete work in walls any thickness including attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level up to floor level excluding cost of centering, shuttering finishing and reinforcement:1:1.5:3 ( 1cement : 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size) |
| 21 | Providing Tor steel reinforcement of 10mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 22 | 8 MM dia |
| 23 | 12,16,20 MM dia |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 25 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.. |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 27 | Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) |
| 28 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 29 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 30 | providing designation 75 B brickwork in C M ('1 :6 ) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of E/l. |
| 31 | Providing designation 75A brickwork in CM (1:3) in superstructure with approved quality of clean coarse sand of FM 2 to 2,5 including providing 10mm thick mortar joints , cost of screening, materials, scaffolding, raking out joints to 15mm depth curing, taxes and royalty all complete as building specification and direction of E/I |
| 32 | Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete |
| 33 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement plaster (!:3) and jointed with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/Iwith \\"A\\" grade white 15 X 15cm tiles |
| 34 | Providing 1.5mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 35 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound including screening, curing, with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 36 | Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound including screening, curing, with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/INote :- Cement used is sulphate resistant cement |
| 37 | Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. |
| 38 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 39 | 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 40 | Providing and fixing ball bearing for rolling shutters. |
| 41 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 42 | Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming toIS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal completeupto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses. 0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm. |
| 43 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete |
| 44 | Providing and laying of coarse aggregate size as below after washing & sieving to make it free from fines & dust. |
| 45 | Stone Aggregate (Single size) : 40 mm nominal size |
| 46 | Stone Aggregate (Single size) : 12.5 mm nominal size |
| 47 | Stone Aggregate (Single size) : 06 mm nominal size |
| 48 | Coarse sand (zone III) |
| 49 | Coarse sand (zone III) (at 70% openings) |
| 50 | Hollow Blocks (200mm X 200mm X 100mm) at 600 Nos/bed |
| 51 | Providing and laying Cinders as a Filter Material In AF as per the instruction given by the site engineer in charge. |
| 52 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 53 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 54 | Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses. 0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm. |
| 55 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment |
| 56 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 57 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 58 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 59 | Inside size 90x80 cm and 45 cm deep including C.I. coverwith frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 60 | Extra for depth for manholes |
| 61 | Size 90x80 cmWith common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 62 | Providing & fixing of CI manhole cover of size 600mm dia ID(5116877-83531042841) |
| 63 | Unbranded Plain ended pipe Unplasticized Pvc Pipes For Potable Water Supplies-Is 4985, Length 3 Meter ID (5116877-75057965346) |
| 64 | Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per building specification and direction of E/I. |
| 65 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or sand paper , applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I |
| 66 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 67 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 68 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 69 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 70 | Providing and stacking Canna dwarf of height 25 to 30 cm., 2 to 3 suckers in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 71 | Providing and Stacking of Lemon grass of ht. 30 cm with multi branches in Poly bag of size 20cm. as per direction of the officer-in-charge. |
| 72 | Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :- (a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with theslurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete (b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat For the purpose of measurernent tte entire treated surface will be measured.\\" |
| 73 | (e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc |
| 74 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 75 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 76 | Supply at site well decayed farm yard manure (supply at site of work well decayed farm yard manure from any available source , approved by engineer in charge including cleaning and stacking) |
| 77 | Turfing lawns with fine grassing including ploughing, dressing (Turfing lawns with fine grassing including ploughing, dressing, including breaking of clods, removal of rubbish, dressing and supplying of doobs grass roots at 10cm apart including supplying and spreading of fam yard manure at rate 0f 0.6 cum per 100sqm) |
| 78 | Maintenance of lawns with fine grassing for one year |
| 79 | Planting flowering plants and shrubs in central verge |
| 80 | Maintenance of flowering plants and shrubs in central verge for 1 year |
| 81 | Planting of trees and their maintenance for one year (planting of trees by the road side (avenue trees) in 0.60m dia holes, 1m deep dug in ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench , watering , fixing the tree guard and maintaining the plants for one year) |
| 82 | Supplying and fitting vitreous white glazed earthen ware wash hand basin of parry or Hindusthan or any other I.S.S. approved make supported on CI or R.S. brackets 32mm C.I brass waste, 15mm dia CI body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc, all complete as per specification and direction of E/I |
| 83 | Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C with 'P' trap of parry hindusthan or any other approved I.S.S make including supplying and fixing 15 litres CI mosquito proof low down flushing cistern of approved make with complete fittings with C.I handle and R.S or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams 15mm P.V.C alkathene pipe 45cm long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S make with hinges or screws etc painting pipe and cistern etc with 2 coats of approved paint over a coat of red oxide priming , all complete as per specification and direction of E/I. with 'P' trap, 12.5 lit low level C.I cistern |
| 84 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece. |
| 85 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 86 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) erge |
| 87 | Providing 50mm thick cement concrete flooring (1:2:4) with 20mm-6mm size graded stone chips finished with floating coat of neat cement in panels including cost of curing, finishing the surface smooth, taxes & royalty with all complete as per building specification and direction of E/I |
| 88 | Providing, fabricating and erecting MS ladder of 450mm wide made of 65 x 65 x 6mm angle iron and 20mm MS bars for walkway to top of the room including cutting, hoistng, fixing in position and applying a priming coat of approved steel primer complete in all respect as per specifications and the direction of the Engineer. |
| 89 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 90 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 91 | Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble.Area of slab over 0.50 sqm |
| 92 | Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses. 0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm |
| 93 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 94 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter |
| 95 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete .150MM PIPE |
| 96 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 300 mm dia. R.C.C. pipe |
| 97 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge100 mm nominal size dia |
| 98 | DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates)Drilling upto 30 mtr. Depth below G.L. in Rural Area |
| 99 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square ba |
| 100 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. |
| 101 | (a) From 0.00 M to 50.00 M below G.L. |
| 102 | (b) From 51.0 M to125.00 M |
| 103 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 104 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 105 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 106 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 107 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages2 HP |
| 108 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I. |
| 109 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 110 | Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. |
| 111 | Providing, fixing, testing and commissioning of Screening constructed from Steel of suitable size for screening out the larger particles from the faecal sludge.Size: 600 mm x 800 mm |
| 112 | Providing, fixing, testing and commissioning of submersible Pumps for feeding Sludge to Stabilization reactor to Sludge drying bed. The pumps shall be complete with motor and required accessories. (Cutter pump)Flow: 1.2 m3/hr.@8-10 m head. |
| 113 | Providing, fixing, testing and commissioning of Filter Feed Pumps (Submersible type) in the storage tank. The pumps shall be complete with motor and required accessories.Flow: 1.4 m3/hr.@25-30 m head. Make: WILO/Kirloskar, KOSM -1.540 M |
| 114 | Providing, fixing, testing and commissioning of treated water transfer Pumps. The pumps shall be complete with motor and required accessories.Flow: 1.4 m3/hr.@10-20 m head. Make: WILO/Kirloskar, KDS GMC-123 |
| 115 | Providing, fixing, testing and commissioning of Interconnecting Piping and valves with all other accessories required to complete the FSTP system.uPVC pipes Supply of UPVC piping of following sizes for FSTP installation |
| 116 | Size: 150 mm |
| 117 | Size: 100 mm |
| 118 | Size: 50 mm |
| 119 | Size: 40 mm |
| 120 | BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified |
| 121 | Size: 25 mm |
| 122 | Size: 40 mm |
| 123 | Size: 50 mm |
| 124 | Size: 100 mm |
| 125 | FITTINGS |
| 126 | ELBOW 50MM |
| 127 | ELBOW 100MM |
| 128 | ELBOW 150MM |
| 129 | TEE 50MM |
| 130 | TEE 100MM |
| 131 | TEE 150 MM |
| 132 | SOCKET 50MM |
| 133 | SOCKET 100MM . |
| 134 | SOCKET 150MM |
| 135 | G.M Non return valve (ISI marked) |
| 136 | Size: 50 mm dia wt. not less than 1.0 kg |
| 137 | Size: 40 mm dia wt. not less than 700 gms |
| 138 | Size: 100 mm dia wt. not less than 1.80 |
| 139 | Y - STRAINER of Ductile CI Body flanged ends with stainless steel50 mm |
| 140 | Providing, fixing, testing and commissioning of Filtration system with Multigrade Sand Filter in FRP construction and comprising of fine and coarse sand, pebbles and gravels as supporting media along with distribution system and all other accessories required to complete the system.Dia- 350 mmHOS: 1500 mm |
| 141 | Providing, fixing, testing and commissioning of GRA-Filtration system with Activated carbon Filter in FRP construction and comprising of activated carbon and coarse sand, pebbles and gravels as supporting media along with distribution system and all other accessories required to complete the system.a- 350 mm |
| 142 | Providing, fixing, testing and commissioning of Chlorine Dosing with dosing pump and tank. Make: Impel |
| 143 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. |
| 144 | 110mm nominal dia |
| 145 | 110mm nominal dia |
| 146 | 110 mm dia U-PVC equal Tee (class III, 6kg/sqcm) confirming to IS:7834 (tee fixing at SR inlet) |
| 147 | 160mm nominal dia (CH3 inlet pipe) |
| 148 | 160 mm dia U-PVC equal Tee (class III, 6kg/sqcm) confirming to IS:7834 (tee fixing at CH3 pipe) |
| 149 | Slotted cowl (terminal guard) 100 mm dia |
| 150 | Unbranded Plain ended pipe Unplasticized Pvc Pipes For Potable Water Supplies-Is 4985, Length 3 Meter ID (5116877-75057965346) |
| 151 | Unbranded PN 16 Commercial UPVC Fittings, Size 1/2\\" - 14\\" TEE (ID 5116877-28301669646) |
| 152 | Unbranded PN 16 Commercial UPVC Fittings, Size 1/2\\" - 14\\"ELBOW.ID (5116877-5114595915) |
| 153 | Single Pipe Clamps SARALR (MS-65)ID ( 5116877-54564818304) |
| 154 | 160mm nominal dia (perforated pipe at bottom) |
| 155 | 160mm nominal dia (vent pipe) |
| 156 | Slotted cowl 160 mm dia |
| 157 | 160 mm dia U-PVC double/ single socketed 90° bend (class III, 6kg/sqcm) confirming to IS:7834 ( elbow at vent pipe , perforated pipe) |
| 158 | 160 mm dia U-PVC equal Tee (class III, 6kg/sqcm) confirming to IS:7834 (tee fixing at vent pipe , perforated pipe) |
| 159 | Ceiling fan 1200mm |
| 160 | P & F 1.6 mm thick M.S. Recessed fan box, hexagonal/ round of size 100 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . |
| 161 | S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required. (Make:- Havells/Philips/Crompton/Wipro.) |
| 162 | 20/22 W LED Tube Light |
| 163 | 12W LED Round Down Light (Recess / Surface ) |
| 164 | G.I. Earth pipe electrode with salt/charcoal: earthing with GI earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required. |
| 165 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. |
| 166 | Group C |
| 167 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 168 | 5/6 amps one way switch |
| 169 | S/F Piano type switch socket:- Supplying and fixing of following piano type switch /socket on the existing switch box cover including connections etc as required |
| 170 | Electronic step fan regulator,deluxe |
| 171 | P & F 18 SWG Sheet steel boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surface or in recessed as required. Size: 150 x 75 x 60 mm |
| 172 | S/F 'C' series, MCB:- Supplying and fixing following, 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 173 | 40 amps,SPN |
| 174 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2x2.5 sq mm + 1x2.5 sq mm earth wire |
| 175 | Providing, fixing, testing and commissioning of MCC panel and Electrical Accessories for all the feeders of FSTP and associated work to complete the system |
| 176 | 4 Core X 10 sq. mm |
| 177 | 3 Core X 1.5 sq. mm |
| 178 | 3 Core x 2.5 sq. mm |
| 179 | 300 mm Width x 50 mm , 1.6 mm thickness |
| 180 | 100 mm width x 40 mm, 1.6 mm thickness |
| 181 | 4x40 watt patty type single tubelight fitting |
| 182 | Recess Mounting LED Round Down Light (12 W) |
| 183 | Ceiling Fan (1200 mm) |
| 184 | LED Street Light (20 W) |
| 185 | G.I. Earth pipe electrode with salt/charcoal: earthing with GI earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required. |
| 186 | SITC of Silent type, Diesel Generator Set of Capacity 10 KVA three phase with with AFM |
| 187 | Change over switch 32 amp |
| 188 | Fire exitinguisher set of 3 (Including transportation, excluding taxes) |
| 189 | Electro-Magnetic Flow Meter |
| 190 | SITC GI Sheet .8 mm thick |
| 191 | SITC Alu U beadings |
| 192 | SITC EPDM Rubber (Above 60 G/M ) |
| 193 | SITC Door/Polycarbonate sheet door with Alu frame 1 1/2\\" GI Sq pipe of 1.4mm thick |
| 194 | SITC Polycarbonate sheet of 6mm thick Double sided UV coated Transparent sheet |
| 195 | SITC GI Fasteners |
| 196 | 100W Solar PV modules with mounting structure , Automatic Temperature And Humidity Controlling System with all internal Electrical wiring materials |
| 197 | SITC 9\\" (230mm) Metal Exhaust fan |
| 198 | SITC 12\\" (300mm) Exhaust fan |
| 199 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 200 | 2 X1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre |
| 201 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Metre |
| 202 | Solar Offgrid Power Plant with accessories5KVA Offgrid Inverter - 1 nos150Ah Solar Battery - 4 nos335W Solar PV Module - 12Mounting Structure - 1Set |
| 203 | Engineering, Supply Installation, Testing & Commissioning of 21.8kW Solar On Grid System power plant SOLAR MODULE 545Wp Solar MonoPERC, 144 cells module SOLAR ON GRID INVERTER Enviro GTi 24 KT - NG DC DISTRIBUTION BOX DC DISTRIBUTION BOX DCDB 4 In 4 Out with Fuse AC DISTRIBUTION BOX 1X63A IN/OUT CABLE SOLAR MODULE TO INVERTER 1C, 4 sqmm Solar DC cable- (Black & Red) INVERTER TO ACDB 4 C X 25 Sq mm, Aluminium Conductor, XLPE Insulated, armoured ACDB TO LT PANEL 3.5 C X25 Sq mm Al conductor, XLPE insulated, Armoured Cables EARTHING SYSTEM FOR STRCUTRE, INVERTER, ACDB GI Strip 25x5 mm for Module Mounting Structure 1C X 50sqmm, Copper Cable GI Strip 25x5 mm MODULE MOUNTING STRUCTURE Mono Rail type shed structure CONDUIT/ CABLE TRAY HDPE Conduit 40 mm (DC Cable interconnections NormalPerforated type Cable trays -with Cover 1.2 Pre Galvanised ) MODULE CLEANING ARRANGMENT Cleaning arrangement accessories & 1 hp mini water pump single phase with water pressure boostinG INSTALLATION & COMMISSIONING Installation & Commissioning Net Metering (If Applicable) Total cost of Job |
| 204 | 1000 Mm X 600 Mm X 750 Mm Unbranded Computer Table consists of Computer table with key board drawer and table top ID (5116877-26677851254) |
| 205 | Revolving Chair with Only Revolving without tilting mechanism (5116877-34440031805) |
| 206 | Nilkamal Plastic Moulded Chair With Arms Without Cushion Single Piece Plastic Moulded ID (5116877-99333142954) |
| 207 | office seating collection Almirah Steel shelving cabinets ID(5116877-86269445252) |
| 208 | Carraige of materials Sand (10km) |
| 209 | Local sand (3 km) |
| 210 | chips (22km) |
| 211 | Bricks |
| 212 | metal (22km) |
| 213 | Operation and maintenance cost(includes manpower cost,Electricity cost,Tool maintence,cesspool vehicle maintence,Electromechanical item maintence,Desludging of settled solids from settler and AF,Maintence Of Gardens,Screen Chamber Maintenance Etc) |
| 214 | Annual Cost (Year-1) |
| 215 | Year-2 Cost@5% escalation |
| 216 | Year-3 Cost@5% escalation |
| 217 | Year-4 Cost@5% escalation |
| 218 | Year-5 Cost@5% escalation |
| 219 | Goods & Service Tax (G.S.T.) - 18 % |
| 220 | Labour Cess - 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysSep 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender