Tender For repair maintenance Various E&M Services In Various Delhi Govt. Offices Under Ae (E) Emsd-Iii, South East, Sunlight Colony, New Delhi.(Sh:- E&M Renovation Work At Shiv Kutiya Mandir Community Center, Hari Nagar, Ashram Under The Nehru Nagar
Tender Overview
Project Description
Tender for repair maintenance Various E&M Services In Various Delhi Govt. Offices Under Ae (E) Emsd-Iii, South East, Sunlight Colony, New Delhi.(Sh:- E&M Renovation Work At Shiv Kutiya Mandir Community Center, Hari Nagar, Ashram Under The Nehru Nagar Fob.)
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | a) Group C |
| 3 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 4 | a) 20 mm |
| 5 | b) 25 mm |
| 6 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. |
| 7 | a) 3 x 1.5 sq.mm |
| 8 | b) 6 x 1.5 sq.mm |
| 9 | c) 3 x 4 sq.mm |
| 10 | d) 6 x 4 sq.mm |
| 11 | e) 3 x 6 sq.mm |
| 12 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 13 | 3 Module (100mmX75mm) |
| 14 | 6 Module (200mmX75mm) |
| 15 | 8 Module (125mmX125mm) |
| 16 | 12 Module (200mmX150mm) |
| 17 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 18 | a) 5/6 amp switch |
| 19 | b) 3 pin 5/6 amp socket outlet |
| 20 | c) 15/16 amp switch |
| 21 | d) 6 pin 15/16 amp socket outlet |
| 22 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 23 | Supplying and fixing of two module stepped type electronic fan regulator on the existing modular plate switch box i/c connections but excluding modular plate etc as reqd. |
| 24 | Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting CBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 25 | a) 8 way (4 + 24), Double door |
| 26 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 27 | a) Single pole |
| 28 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required. |
| 29 | a) 100 A, 16 KA,TPMCCB |
| 30 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 31 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 32 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 33 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximumpower consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 34 | 70 watt |
| 35 | Supplying and fixing of suitable H-shape angle iron suitable for fixing/mounting LED flood light on terrace etc as reqd. |
| 36 | Supplying and fixing of pole box (200mmx140mmx95/100 deep) made out hot moulded SMC with 01no 16amp 3pole connector, din channel and 01 No. 6 Amp SPMCB complete with connections earthing testing etc as reqd. |
| 37 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 38 | 36 watt |
| 39 | Supplying installation, testing and commissioning of 120mm x 1200mm, 22watt LED fitting minimum luminous 2600lm, THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.) along with suspended type suitable fastener for height upto 20mtr i/c connection with 1.5sqmm FRLS copper conductor single core cable suitable for 230volt 50Hz AC supply etc as reqd. |
| 40 | Supplying. Installation, testing and commissioning of 300 mm sweep metallic heavy duty 900 rpm exhaust fan suitable for operation on 230V, 50 Hz single phase AC supply complete with louvers / shutters in the existing opening including making the hole to suit the size of the above fan making good the damage and connections etc. as reqd. |
| 41 | Supplying & Intallation of fresh air fan 250 mm sweep with shutter and louver in the existing opeining , including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 42 | Supplying. Installation, testing and commissioning of 600 mm sweep wall mounted heavy duty industrial fan suitable for operation on 230V, 50 Hz single phase AC supply and connections etc. as reqd. |
| 43 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 44 | a) 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) |
| 45 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 46 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 47 | Supplying, Installation, Testing and Commissioning of Air Cooled Floor standing Tower type split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5 Mtr (IDU to ODU), copper power cable upto 5.5 Mtr (IDU to ODU), i/c drain pipe of suitable length and size. R-32/R-410/R-407C Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). asspecified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required. (a) 3.8 TR BEE 5 Star Rating |
| 48 | Providing and fixing Steel D-Hook Hanger (Heavy Duty) with M10X75mm Fasteners for Hanging Ceiling Fan complete etc as reqd. |
| 49 | Supplying and fixing 125 amps on load change over switch 4 pole, 415 volt 50Hz with sheet steel enclosure i/c connection with suitable size of thimbles / wires etc as reqd. |
| 50 | Supplying Installation Testing and commissioning of water cooler with 150/150ltr storage capacity suitable for operation on 230Volts 10%, 50Hz, single phase AC supply with high efficiency compressor faster cooling, ergonomically desgined for greater safety and operational convenience low power consumption, superior quality grooved copper tubes in heat exchager, ISI marked blue fins on condensor coil, stainless steel body for longer product lift, stainless steel tank food grade water piping float valve and other components which come in contact with drinking water, water inlet, hosepipe, overflow pipe to be provided with water cooler packing adjustable pedestal made of high non corrosive strong material minimum two number faucets etc complete as reqd. |
| 51 | Supplying Installation Testing and Commissioning of 50LPH RO System design to deliver upto 50ltrs of purified water per hour through a 6 stage purification process. its membrane should have a pore size of 0.0001 micron size which prevents the passage the micro organisms and total dissolved salts making the water lighter test natural and save to drink. the RO system should have 04nos of 75 GPD membrane, system operating voltage 48volt DC suitable for operating temperature 5 degree to 45 degree, suitable for 230volt 50Hz AC supply i/c making plubming connection and interconnection with pipe, pipe accessories complete etc as reqd. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender