Tender For Repair/Replacement And Maintenance To Internal Wiring & Flame Proof Wiring Including Repairs To Ceiling/Exhaust/Air Circulator Fan, Ceiling Lights, Misc Repairs Of Lightning & Conductors & Its Related Works Including Certain Repairs To Fir

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Sep 2026
14 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement And Maintenance To Internal Wiring & Flame Proof Wiring Including Repairs To Ceiling/Exhaust/Air Circulator Fan, Ceiling Lights, Misc Repairs Of Lightning & Conductors & Its Related Works Including Certain Repairs To Fire Alarm System Of Various Offices Of Cqa (Ee), Cqa (Me), Cqa (Ffe) & Di Cell Of Dgqa Area Under Ge (Mh & Rh) Khadki

BOQ

Name of Work:- REPAIR/REPLACEMENT AND MAINT TO INTERNAL WIRING & FLAME PROOF WIRING INCLUDING REPAIRS TO CEILING/EXHAUST/AIR CIRCULATOR FAN, CEILING LIGHTS, MISC REPAIRS OF LIGHTNING & CONDUCTORS & ITS RELATED WORKS INCLUDING CERTAIN REPAIRS TO FIRE ALARM SYSTEM OF VARIOUS OFFICES OF CQA (EE), CQA (ME), CQA (FFE) & DI CELL OF DGQA AREA UNDER GE (MH & RH) KHADKI
Sl. No. Item Description
1Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit (credit for above items shall be made as per condition laid down under schedule of credit seprately ) and making good disturbed surfaces of walls, floors etc all as specified.
2M&L for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and unsheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade, PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories surface PVC box of suitable size (thickness not less than 2 mm) to provision of modular switches to house hold switches/regulators etc including modular plate and covers for one light/fan/bell point controlled by one switch/bell push complete including PVC insulated multistranded copper conductor 1.5 SQ mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by engr in charge for the following :-
3One fan/light /bell point controlled by one switch/bell push
4One switch socket outlet 5 Amps on independent board
5One socket outlet 5 Amps on the same board
6All as per Item No- 2 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board complete all as specified and directed by Engr- in - Charge.
7All as per Item No- 2 here-in-before but with 4.0 Sqmm PVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4 sqmm as earth continuity conductor for power socket on independent board complete all as specified and directed by Engr- in - Charge.
8M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC Cassing capping of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge..Note: Two single core cable, earth wire and PVC conduit shall be measured as one length.
9Ditto item No- 05 above but of 6 Sqmm .
10Supply and fix in repair ceiling rose surface bakelite with three terminals type in all as specified and directed.
11Supply and fix in repairs switch piano type one way 6 Amps flush type ,240volt AC all as specified and directed.
12Supply and fix in repairs socket outlet 2 in1,3 pin 5 Amps all as specified and directed.
13Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3 pin, 5 Amps flush type ,240volt AC all as specified and directed.
14Supply and fix in repairs switch piano type 16 Amps flush type ,240volt AC all as specified and directed.
15Supply and fix in repairs socket outlet 2 in 1, 3/5 pin 16 Amps flush type all as specified and directed.
16Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3/5 pin, 16 Amps flush type ,240volt AC all as specified and directed.
17Supply and fix in repairs Bell push, flush type, 6 Amp flush type ,240volt AC all as specified and directed.
18Supply and fix in repairs switch piano type two way 6 Amps flush type ,240volt AC all as specified and directed.
19Supply and fix in repairs Bell push, Modular type, 6 Amp flush type ,240volt AC all as specified and directed.
20Supply and fix in repair modular switch 1 way 6A 1 module complete all as specified and directed.
21Supply and fix in repair modular switch 16A 1 module complete all as specified and directed.
22Supply and fix in repair modular socket 6A 2/3 pin combined 2 module complete all as specified and directed.
23Supply and fix in repair modular socket 6A /16A 2/3 pin combined 2 module complete all as specified and directed.
24Supply and fix in repair modular fan regulator,120 watt - 2 module complete all as specified and directed.
25S & Fix in repair stepped type electronic fan regulator 120 watt ,240 volt flush type on the existing phenolic laminated sheet
26Supply and fix in repair electric bell Ding Dong, AC 230 volts complete all as specified and directed.
27Supply and fix in repair Modular white cover plate with frame of following size complete all as specified and directed :-
281 module
292 module
303 module
314 module
326 module
338 module
34Supply and fixing replacement of RCCB 63 A , four pole, 30 mA all as specified and directed by Engr-in-chrge. Make: Hager/L & T/Standard
35Supply and fix in repair of industrial wall mounted plug socket suitable fotr IP 44 degree of protection of 32Amps rating 2P+E all as specified and directed.
36S & F in repair of sheet metal enclosures for double door distribution board factory made duly painted of following capacity with 200 amps rated bus bar , suitable for fixing MCB /Isolators all as specified :-Make:L & T/legrand/Havells or equivalent.
3712 way SPN , 240V
388 way SPN 240V
394 way TPN ,415V
406 way TPN ,415V
41S & F in repair of MCCB 125 Amps, 4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity Make: L &T /Legrand/Indoasian/standard.
42Ditto item no 28 Above but of capacity 100 Amps.
43Supply and fixing in repair of miniature circuit breaker (MCB) of following current carrying capacity, in the MCB DB Complete with connection testing and commissioning.Make L &T /Legrand/Havells
44SP 5/6 to 32 AMP,240V, 10 KA 'B' curve
45SP 40 AMP,240V, 10 KA 'B' curve
46SPN 32 Amps,240V, 10 KA 'B' curve
47SPN 40 Amps ,240V, 10 KA 'B' curve
48TPN 63Amps,240V, 10 KA 'B' curve
49S & F in repair of wall mounted extruded aluminium housing high quality indoor batten of 20/22 watts capacity colour temperature 6500 K (4' long), lumen 2000 -3000, PF> 0.9, THD less 15% diffused connecting with suitable size flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge. Make : Havells/wipro/Halonix or eqivalent
50Ditto item No-31 but LED tubelight fitting of 10 watt, 2 feet long
51S & F in repair of lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings all as specified and directed
52S & F in repair of Recess/Surface mounting LED flat panel light fitting of wattage 36 watts, size 600mmx600mm and with efficient LEDs lumen 2000 -3000, PF> 0.9, THD less 15% and make all as specified and directed. Make : Havells/wipro/Halonix
53S & F in repair of Recess/Surface mounting LED flat panel light fitting of wattage 25 watts, size 300mmx300mm and with efficient LEDs lumen 2000 -3000, PF> 0.9, THD less 15% and make all as specified and directed. Make : Havells/wipro/Halonix
54S&F in repair of fix high efficent LEDbuilding security light 30 watt , 230 V , lumen 2000 -3000, PF> 0.9, THD less 10%, made of pressutre cast aluminuim housing with high power LEDs, lens and touughned glass IP 66 connecting with three core flexible copper wire from connecto to ceiling rose. Make Halonix ,Bajaj,Havells or equivalent.
55S & F in repair bracket for mounting building security light made out of 40 mm dia Light Grade GI pipe bend in angle with holding MS clamps two nos each bracket of size 25x3 mm including screw etc for fixing all as specidfied and directed by Engr in charge
56M & L for rewinding of Ceiling Fan, Exhaust Fan and Air circulator of any type/make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection,capacitor base and testing complete all as specified and directed by Engr-in-Charge. Note: (a) Bearing ,fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule.
57Ceiling fan of 1200/1400 mm sweep
58Exhaust Fan of sweep 275-300 mm
59Exhaust Fan of sweep 350-450 mm
60Supply only ball bearing (DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC
61Supply only ball bearing suitable for 275-450 mm exhaust fan complete all as specified and directed Make : SKF/NBC or equivalent
62Supply only fan capacitor of following capacity
63capacitor 2.5 mfd
64capacitor 4 mfd
65Supply only , rubber yoke, MS Clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and as directed by Engr-in-charge.
66Supply only gunmetal bush suitable size for ceiling fan 1200 /1400 mm sweep complete all as specifed and directed by Engr-in-Charge.
67supply only fan down rod of following length with white enammbeled painted with both side hole for hanging fan of sweep 1200/1400mm sweep all as specifeied and directed by Engr in charge
681 ft long
692 ft long
70Supply only fan canopy set off white /white coloured as per colour of ceiling fan of sweep1200/1400mm all as specified and directed.
71Supply only stator for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting rotor size all as specified and directed
72Supply only rotor for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting stator size all as specified and directed
73M & L for replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of following size make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
74100 x 100 mm and 50 mm deep
75200 x 150 x 50 mm deep
76250 x 200 x 50 mm deep
77M&L for point wiring flame proof in stove enamelled ERW steel conduit 20 mm dia medium grade on surface with ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRHR) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRHR) copper conductor cable as earth wire with all flame proof fittings such as elbow, bends, junction boxes, ceiling rose saddles , flexible metal conduits etc. incl suitable size of sheet metal box 1.6mm thick (ISI Mark), screws and rawal plug etc. and connected to light/fan and common earth dolly with necessary copper thimbels all as specified and directed by the Engr-in-charge for the following :-
78One light/fan point controlled by one, one way flame proof switch .
79-Ditto- all as per item No 48 here-in-before but for socket out let, 15/16 Amps. independent with 2.5 Sqmm size cable and 2.5 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed by Engr - in - charge.
80S&F in repair of Fluorescent tube light fitting 1x16W flameproof type FLP-WP made of aluminium alloy LM6, complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specifiede and directed. Make, Cat No. - EXTL140 Crompton Greaves/Shyaam/Sudheer.
81S&F in repair of FLP-WP flood light fittings of capacity 120 watts made of aluminium alloy LM6, complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed by Engr-in-charge. Make-Shyaam, Cat No. - SSPL/1251 or Sudhir or equivalent.
82M & L for rewinding of flame proof ceiling fan of 1200/1400 mm sweep of any make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection,capacitor base and testing complete all as specified and directed by Engr-in-Charge. Note: (a) Bearing ,fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule.
83All as per item No 55 above but Exhaust Fan of sweep 300-450 mm
84S&F in repair of FLP - WP switch socket and plug combined in LM6 aluminium alloy 16 A 2P + Earth complete all as specified and as per Make-Sudhir/Shyaam or equivalent. .
85S&F in repair of FLP - WP switch flame proof rotary ON-OFF type with termination box in LM6 aluminium alloy, 10/16A, single pole 250V all as per Make-Shyaam, Cat No. - SSPL/2C/1010. or Sudhir or equivalent.
86S & F in repair of Flame proof, weather proof 12 way SPN MCB DB 240 V. 50 Hz in LM 6 construction, consisting of 01 No. incoming MCB SPN- 63 Amps(01 Nos), MCB SP – 6 to 32 Amps (10 Nos), 10KA Breaking capacity as outgoing with clip on type terminals with suitable cable entries certified by CMRI Dhanbad.Make :- Shyaam Cat Part NO-SSPL/MCDB/186 or Sudhir or equivalent.
87S&F in replacement of Flame proof , weather proof 8 way SPN MCB DB 240 volts in LM 6 construction consisting of 01 nos of incomer MCB SPN -40/32 amps (01) Nos MCB SP -06 -32 Amps 06 nos 10 KA breaking capacity as outgoing all as specified. Make :- Shyaam Cat Part NO-SSPL/MCDB/186 or Sudhir or equivalent.
88S&F in replacement for submain wiring alongwith earth wire with FRHR PVC insulated copper conductor, multistranded, on surface of size 2 x 6.0 Sqmm & 1 x 6 Sqmm earth wire in ERW steel conduit all as directed by Engr-in-Charge. Note: Two run of FRHR PVC insulated copper cable, earth wire and Steel conduit shall be measured as one length.
89Servicing and Maintenance of Micro Processer based fire alarm control panel of any make installed at main bldg of CQA (EE) comprising of various loops data card, battery, LCD/LED display panel, buzzers, response indicators, heat and smoke detectors etc, including testing by OEM all as specified and as directed.Notes :-(i) The Rates are inclusive of regular inspection of authorised OEM, once in a month. (ii) The maint and servicing includes clearing the fault in loop wiring , cleaning the heat/smoke detectors with blowers, response indicator, MCP, Sounder cum Strobe with control module etc all as directed by Engineer In Charge.(iii) Major Spares required for maintenance of the above panel shall be measured and paid separately under relevant item.
90Supply only addressable smoke detector complete including dismantling the old unsv SD all as specified and directed.
91Supply only addressable manual Call point including dismantling the old unsv call points complete all as specified and directed.
92Supply only addressable sounder complete including dismantling the old unsv sounders all as specified and directed.
93Supply only 12 volt 7 AH/10AH battery complete including dismantling the old batteries all as specified and directed.
94Supply, draw, connecting, testing and commissioning of 2 core 1.5 sq mm stranded copper conductor, PVC insulated PVC sheathed FRLS, flexible armoured cable laid on ceiling/wall clamped with aluminium clamps/ drawn in ERW pipe including taking down of old unsc one and complete all as specified and directed .Note :- (i) The cables are to be drawn through the false ceilings, laid in floors, fixed to walls as per the site requirements.(ii) The conduits are to be measured and paid seperately under relevent item.
95Supply and laying in replacement of Mild Steel Stove enameled black conduit alongwith the accessories such as tees, bends, elbows, bell mouth ends and all fixing accessories such as couplers, locknuts, saddles, pipe hook etc. on surface/recess including painting, in case of recessed conduit, cutting the wall and making good the same for of recessed conduit of size 25 mm dia.complete all as specified and directed.
96M & L in replacement of earthing complete in repairs with galvanised steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvanised earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. (Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge. )
97M & L for repairs /re-fixing on exiting or new location to storage type electric water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following works mentioned here under againt Ser Nos (a) to (f) at different locations (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank (b) Examine water tightness of storage tank after cleaning.(c) Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (d) S & F Replacement of the rubber / PVC gasket to ensure water tightness. (e) Checking of safety valve (f) Testing of geysers after repairs.
98S & F in repairs thermal cutout ISI marked temp range 50-80/90 degree as required at site for geyser of capacity 25/35/50 Ltr of any make all as directed by Engr-in-charge
99S & F in repairs of safety valve/high pressure valve ISI marked as per site requirement or all as per directed by Engineer-in-Charge.
100S & F in repairs heating element of following rating as required at site including rubber washers all as specified and directed by Engr-in-charge..
1011/1.5 KW,240 volt
1022 KW ,240 volt
103S & F in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection all as specified and directed by Engr-in-Charge
104S & Fixing in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection all as specified and directed by Engineer-in-charge.
105S & Fixing in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
106S & F stop valve , cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore all as specified and directed by Engr-in-Charge
107M & L for repairing and replacment of unserviceable copper container of capacity 25/50 Ltrs of solar water heater of any type after completion of work testing the heater all as specified and directed by Engr-in-Charge
108Copper container 50/100 ltr
109Copper container capacity 25 Ltrs of water heater (gyeser)
110Taking down of unserviceable copper/GI/Aluminium earthing strip any size complete all as directed.
111S&F in replacement copper strip of size 20mmx3mm thick for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing/down conductor strip etc, complete all as specified and as directed by Engineer-in-charge.
112S&F GI steel strip of size 32mmx6mm thick for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as in repair complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information
113S&F GI steel strip of size 32mmx6mm thick for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as in repair complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57046498
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 07-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement And Maintenance To Internal Wiring & Flame Proof Wiring Including Repairs To Ceiling/Exhaust/Air Circulator Fan, Ceiling Lights, Misc Repairs Of Lightning & Conductors & Its Related Works Including Certain Repairs To Fire Alarm System Of Various Offices Of Cqa (Ee), Cqa (Me), Cqa (Ffe) & Di Cell Of Dgqa Area Under Ge (Mh & Rh) Khadki
Basic Detail
Tender No 8834/E8
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 17 Aug 2026
Submission Date 07 Sep 2026
Open Date 09 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD Ref. Documents
Exemption Not Available
Document List
393f80e6-b365-4a54-a658-16f40a3c15e4.html
BOQ_879305.xls
T8834.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

393f80e6-b365-4a54-a658-16f40a3c15e4.html

xls

BOQ_879305.xls

pdf

T8834.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders