Tender for Repair/Replacement To Various Dbs, Internal Light Fixtures And Certain Repairs To Ceiling Fans, Exhaust Fans & Geysers At Md Accn Of Dgqa Org Under Ge (Mh & Rh) Khadki
BOQ
| Sl. No. | Item Description |
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit (credit for above items shall be made as per condition laid down under schedule of credit seprately ) and making good disturbed surfaces of walls, floors etc all as specified. |
| 2 | M&L for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and unsheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade, PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories including surface PVC box of suitable size (thickness not less than 2 mm) to provision of modular switches to house hold switches/regulators etc including modular plate and covers for one light/fan/bell point controlled by one switch/bell push complete including PVC insulated multistranded copper conductor 1.5 SQ mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by engr in charge for the following :- |
| 3 | One fan/light /bell point controlled by one switch/bell push |
| 4 | One switch socket outlet 5 Amps on independent board |
| 5 | One socket outlet 5 Amps on the same board |
| 6 | All as per Item No- 2 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board complete all as specified and directed by Engr- in - Charge. |
| 7 | All as per Item No- 2 here-in-before but with 4.0 Sqmm PVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4 sqmm as earth continuity conductor for power socket on independent board complete all as specified and directed by Engr- in - Charge. |
| 8 | M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC Cassing capping of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge..Note: Two single core cable, earth wire and PVC conduit shall be measured as one length. |
| 9 | Ditto item No- 05 above but of 6 Sqmm . |
| 10 | Supply and fix in repair ceiling rose surface bakelite with three terminals type in all as specified and directed. |
| 11 | Supply and fix in repairs switch piano type one way 6 Amps flush type ,240volt AC all as specified and directed. |
| 12 | Supply and fix in repairs socket outlet 2 in1,3 pin 5 Amps all as specified and directed. |
| 13 | Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3 pin, 5 Amps flush type ,240volt AC all as specified and directed. |
| 14 | Supply and fix in repairs switch piano type 16 Amps flush type ,240volt AC all as specified and directed. |
| 15 | Supply and fix in repairs socket outlet 2 in 1, 3/5 pin 16 Amps flush type all as specified and directed. |
| 16 | Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3/5 pin, 16 Amps flush type ,240volt AC all as specified and directed. |
| 17 | Supply and fix in repairs Bell push, flush type, 6 Amp flush type ,240volt AC all as specified and directed. |
| 18 | Supply and fix in repairs switch piano type two way 6 Amps flush type ,240volt AC all as specified and directed. |
| 19 | Supply and fix in repairs Bell push, Modular type, 6 Amp flush type ,240volt AC all as specified and directed. |
| 20 | Supply and fix in repair modular switch 1 way 6A 1 module complete all as specified and directed. |
| 21 | Supply and fix in repair modular switch 16A 1 module complete all as specified and directed. |
| 22 | Supply and fix in repair modular socket 6A 2/3 pin combined 2 module complete all as specified and directed. |
| 23 | Supply and fix in repair modular socket 6A /16A 2/3 pin combined 2 module complete all as specified and directed. |
| 24 | Supply and fix in repair modular fan regulator,120 watt - 2 module complete all as specified and directed. |
| 25 | S & Fix in repair stepped type electronic fan regulator 120 watt ,240 volt flush type on the existing phenolic laminated sheet |
| 26 | Supply and fix in repair electric bell Ding Dong, AC 230 volts complete all as specified and directed. |
| 27 | Supply and fix in repair Modular white cover plate with frame of following size complete all as specified and directed :- |
| 28 | 1 module |
| 29 | 2 module |
| 30 | 3 module |
| 31 | 4 module |
| 32 | 6 module |
| 33 | 8 module |
| 34 | Supply and fix in repair of industrial wall mounted plug socket suitable fotr IP 44 degree of protection of 32Amps rating 2P+E all as specified and directed. |
| 35 | S & F in repair of sheet metal enclosures for double door distribution board factory made duly painted of following capacity with 200 amps rated bus bar , suitable for fixing MCB /Isolators all as specified :-Make:L & T/legrand/Havells or equivalent. |
| 36 | 12 way SPN , 240V |
| 37 | 8 way SPN 240V |
| 38 | 4 way TPN ,415V |
| 39 | 6 way TPN ,415V |
| 40 | S & F in repair of MCCB 125 Amps, 4 pole, Breaking capacity 25 KA, 415 V adjustable type all as specified of capacity Make: L &T/Legrand/Indoasian. |
| 41 | Ditto item no 28 Above but of capacity 100 Amps. |
| 42 | Ditto item no 28 Above but of capacity 63 Amps. |
| 43 | Supply and fixing in repair of miniature circuit breaker (MCB) of following current carrying capacity, in the MCB DB Complete with connection testing and commissioning.Make L &T /Legrand/Havells |
| 44 | SP 5/6 to 32 AMP,240V, 10 KA 'B' curve |
| 45 | SP 40 AMP,240V, 10 KA 'B' curve |
| 46 | SPN 32 Amps,240V, 10 KA 'B' curve |
| 47 | SPN 40 Amps ,240V, 10 KA 'B' curve |
| 48 | TPN 63Amps,240V, 10 KA 'B' curve |
| 49 | S & F wall mounted extruded aluminium housing high quality indoor batten of 20/22 watts capacity colour temperature 6500 K (4' long), lumen 2000 -3000, PF> 0.9, THD less 15% diffused connecting with suitable size flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge. Make : Havells/wipro/Halonix or eqivalent |
| 50 | Ditto item No-31 but LED tubelight fitting of 10 watt, 2 feet long |
| 51 | S & F in repair of wall mounted high quality indoor wall bracket light cylinderical/oval shape aesthetically designed fitting in PVC housing , glass and B22 holder complete including inverter LED bulb B-22 cap with opal diffuser, IP-20 and inbuilt battery backup (LED INVERTER LIGHT 10W B22 CW IP) 10 watts including necessary eletric connection with PVC insulated multistranded copper cable of 3 core from ceiling rose to fitting terminal complete all as specified and directed. Make : Havells/wipro/Halonix or eqivalent |
| 52 | S & F in repair of lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings all as specified and directed |
| 53 | S & F in repair of Recess/Surface mounting LED flat panel light fitting of wattage 36 watts, size 600mmx600mm and with efficient LEDs lumen 2000 -3000, PF> 0.9, THD less 15% and make all as specified and directed. Make : Havells/wipro/Halonix |
| 54 | S&F in repair of fix high efficent LEDbuilding security light 30 watt , 230 V , lumen 2000 -3000, PF> 0.9, THD less 10%, made of pressutre cast aluminuim housing with high power LEDs, lens and touughned glass IP 66 connecting with three core flexible copper wire from connecto to ceiling rose. Make Halonix ,Bajaj,Havells or equivalent. |
| 55 | S & F in repair bracket for mounting building security light made out of 40 mm dia Light Grade GI pipe bend in angle with holding MS clamps two nos each bracket of size 25x3 mm including screw etc for fixing all as specidfied and directed by Engr in charge |
| 56 | M & L for rewinding of Ceiling Fan, Exhaust Fan and Air circulator of any type/make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection,capacitor base and testing complete all as specified and directed by Engr-in-Charge. Note: (a) Bearing ,fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule. |
| 57 | Ceiling fan of 1200/1400 mm sweep |
| 58 | Exhaust Fan of sweep 275-300 mm |
| 59 | Exhaust Fan of sweep 350-450 mm |
| 60 | Supply only ball bearing (DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC |
| 61 | Supply only ball bearing suitable for 275-450 mm exhaust fan complete all as specified and directed Make : SKF/NBC or equivalent |
| 62 | Supply only fan capacitor of following capacity |
| 63 | capacitor 2.5 mfd |
| 64 | capacitor 4 mfd |
| 65 | Supply only , rubber yoke, MS Clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and as directed by Engr-in-charge. |
| 66 | Supply only gunmetal bush suitable size for ceiling fan 1200 /1400 mm sweep complete all as specifed and directed by Engr-in-Charge. |
| 67 | supply only fan down rod of following length with white enammbeled painted with both side hole for hanging fan of sweep 1200/1400mm sweep all as specifeied and directed by Engr in charge |
| 68 | 1 ft long |
| 69 | 2 ft long |
| 70 | Supply only fan canopy set off white /white coloured as per colour of ceiling fan of sweep1200/1400mm all as specified and directed. |
| 71 | Supply only stator for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting rotor size all as specified and directed |
| 72 | Supply only rotor for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting stator size all as specified and directed |
| 73 | M & L for replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of following size make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge. |
| 74 | 100 x 100 mm and 50 mm deep |
| 75 | 200 x 150 x 50 mm deep |
| 76 | 250 x 200 x 50 mm deep |
| 77 | M & L in replacement of earthing complete in repairs with galvanised steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvanised earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. (Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge. ) |
| 78 | M & L for repairs /re-fixing on exiting or new location to storage type electric water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following works mentioned here under againt Ser Nos (a) to (f) at different locations (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank (b) Examine water tightness of storage tank after cleaning.(c) Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (d) S & F Replacement of the rubber / PVC gasket to ensure water tightness. (e) Checking of safety valve (f) Testing of geysers after repairs. |
| 79 | S & F in repairs thermal cutout ISI marked temp range 50-80/90 degree as required at site for geyser of capacity 25/35/50 Ltr of any make all as directed by Engr-in-charge |
| 80 | S & F in repairs of safety valve/high pressure valve ISI marked as per site requirement or all as per directed by Engineer-in-Charge. |
| 81 | S & F in repairs heating element of following rating as required at site including rubber washers all as specified and directed by Engr-in-charge.. |
| 82 | 1/1.5 KW,240 volt |
| 83 | 2 KW ,240 volt |
| 84 | S & F in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection all as specified and directed by Engr-in-Charge |
| 85 | S & Fixing in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection all as specified and directed by Engineer-in-charge. |
| 86 | S & Fixing in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge. |
| 87 | S & F stop valve , cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore all as specified and directed by Engr-in-Charge |
| 88 | M & L for repairing and replacment of unserviceable copper container of capacity 25/50 Ltrs of solar water heater of any type after completion of work testing the heater all as specified and directed by Engr-in-Charge |
| 89 | Copper container 50/100 ltr |
| 90 | Copper container capacity 25 Ltrs of water heater (gyeser) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓