Defence Statutory Bodies & Commissions/Committees Closing in 7 days TDR #57046474

Tender For Repair/ Maintenance To Central Heating System, Indoor And Outdoor Units And Other Connected Works At Alg Tawang Under Ge 859 Ews

Issued by Statutory Bodies & Commissions/Committees · Tawang, Arunachal Pradesh
Tender Value
13 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
7 days left
EMD
26000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tawang → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance To Central Heating System, Indoor And Outdoor Units And Other Connected Works At Alg Tawang Under Ge 859 Ews

BOQ

Name of Work:-
Sl. No. Item Description
1A : MRV (VRF) Outdoors:Service of Variable Refrigerant Flow of Side Discharge Heat Pump Outdoor Unit with 100% DC Inverter based Compressor in each System/modules; connectable to multiple Indoor Units as per specification:(a)The Outdoor unit should be of fully inverter scroll / rotary compressors with special pre-coated fins, panel, corrosion resistant (suitable for seaside installation) coated condenser, inverter based condenser fan M.S. hot dip galvanised stands / supports, electrical & microprocessor panel with internal cabling, isolating valves, Indivisual as well as Central remote Controler, software, follwing indoor units and all the necessary accessories for proper functioning of the units, having following approximate capacities. The System is considered for both Cooling as well as Heating purpose.(b)The Outdoor units shall be factory assembled weather proof casing constructed from heavy gauge mild steel with Inverter Scroll / Rotary Compressor with Liquid injection facility in order to achive no deration in cooling capacity upto -5deg ºC to +50deg ºC Temp.(c)The Outdoor Unit has 2 stage deep sub-cooling circuit and cross oil return technology, should be equipped with double EEV control design & four way air return heat exchanger design.(d)The Outdoor Unit should have Error code LED display for ease of operation & Each compressor should have Oil Separator for safer operation; Automatic Oil Balancing; PCB cooled by refrigerant; Eco friendly refrigerant R-410a, The Heat Pump type & suitable for operation within the ambient temperature range Up to 50º C.(e)The outdoor unit fitted with low noise aero spiral design fan with multiple speed DC motor. EER (Minimum): 3.9 Capacity of Outdoor Unit: 22 HP Servicing
212 to 20 HP Servicing
37.5 to 10 HP Servicing
4B : MRV (VRF) Indoors:(a) Service of MRV (VRF) Indoor of AHU Units equipped with pure copper evaporator coils & will be configurated with the above outdoors. The required power supply will be 3 phase 220V ± 10% at every indoor location. The Indoor Units should be complete with electronic expansion valve with BLDC fan motor, controls and insulated drain pan. The price of indoor unit with Panel Re Commissioning.
5(b) Service of MRV (VRF) Indoor Split & Cassette A/C
6Remote Controllers for LG AHU Unit
7Remote Controllers for Split Indoor Unit
8Supply only LG 20 HP Main PCB
9Supply onlyLG 20 HP Noise Filter PCB
10Supply only L G 20 HP Fan PCB
11Supply only L G 20 HP Inverter PCB
12Supply only L G 20 HP Diod Bridge PCB
13Refrigerant Piping Works:(a)Welded (all type) of refrigerant piping for the air conditioning system, shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including Nitrile Insulation tubes over refrigerant pipes. It also includes supports to hang the copper pipes as required. ( Approx )
14M & L for charging of R140a gas as directed.
15Supply and fixing PCB jack 3 & 2 as directed.
16S & F Contractor (L&T) as per sample as directed.
17S & F communication wire as required at site as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57046474
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13 Lakhs
LAST DATE 29-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance To Central Heating System, Indoor And Outdoor Units And Other Connected Works At Alg Tawang Under Ge 859 Ews
Basic Detail
Tender No 9051/E8
Bidding Type Tender
Location
City Tawang
State Arunachal Pradesh
Key Dates
Publish Date 17 Aug 2026
Submission Date 29 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 13 Lakhs
Tender Fee 500
EMD 26000
Exemption Available
Document List
1591a65c-883c-4031-95aa-c8e0a4970df9.html
BOQ_879254.xls
Tender9051.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

1591a65c-883c-4031-95aa-c8e0a4970df9.html

xls

BOQ_879254.xls

pdf

Tender9051.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders