Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #57046469

Tender For Completion Of Balance Work Of Improvement To Bldg No P-48 (Bls) , P-22 (Ration Store ) & P-23 (Tech Hq) At 25 Ed Under Ge (Af) Ojhar

Issued by Statutory Bodies & Commissions/Committees · Nashik, Maharashtra
Tender Value
26.60 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
14 days left
EMD
53200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Completion Of Balance Work Of Improvement To Bldg No P-48 (Bls) , P-22 (Ration Store ) & P-23 (Tech Hq) At 25 Ed Under Ge (Af) Ojhar

BOQ

Name of Work:- COMPLETION OF BALANCE WORK OF IMPROVEMENT TO BLDG No P-48 (BLS) , P-22 (RATION STORE ) & P-23 (TECH HQ) AT 25 ED UNDER GE (AF) OJHAR
Sl. No. Item Description
1Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each.
2All as item 1 herein before but exc 1.5 sqm but not 4 Sqm each
3Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each.
4S&F second class hard wood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats
5S&F 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003(Part I), kiln seasoned and chemically pressure treated
6S & F factory made solid panel PVC door frame of size 50mmx47mm out of 5mm wood grain printed PVC sheet & edges will be printed to match with printed sheet reinforced with M.S. square tube, all as per specification and drawing.
7S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strips of 20 mm width stuck inside with solvent cement for stiles and single sides prelam PVC sheet and stile & rails having one side feathered edge and on other side 10mm (90°) bent edges & as gap insert for top rail & bottom rail; Panelling to be fitted in the M.S. frame welded/ sealed to the styles & rail with suitable PVC sheet beading, and joint together with solvent cement, all as specification and drawing.
8S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as completed
9S & F 4mm thick sheet glass ordinary quality and glazing not exe 0.5 sqm in each pane.
10M&L 2nd class HW plain solid straight chowkhats and frames worught framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete
11S&F 100 mm long Butt hinges, extruded aluminium ally with galvanished mild steel hinge pin anodised and fixed type B-21
12S&F mild steel butt hinges medium weight cold rolled 100 mm size
13S & F 150 mm size aluminium anodised barrel tower bolt of extruded section .
14S&F 300 mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) & fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
15S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised.
16S & F in repair ordinary rat tails150 mm size pattern door springs including roller and roller plate complete.
17S&F in repair 75 mm length floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring Fixed in floor
18S & F stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.4 mm and fixed with stainless steel wire staples including necessary wooden bedding.
19S & F in repair stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.4 mm and fixed with stainless steel wire staples including necessary wooden bedding.
20M&L 2 coat of synthetic enamel painting to wood and wood based material surfaces exc 10cm width or girth over a one coat of pink primer incl preparation.
21M&L preparation of old painted surfaces applying 2 coat of synthetic enamel painting to wood and wood based material surfaces exc 10cm width or girth.
22S&F powder coating anodised aluminium section for shutter/frame for door, window and ventilator complete all as specified.
23S & F powder coated aluminium window and ventilator shutters, sliding type 3 track without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
24S & F plain sheet glass 5 mm thick tinted, fixed to aluminium doors/ windows / ventilators complete all as directed by Engr-in-Charge (Note:- Beading/rubber packing is included in the rates for aluminium sections above.)
25Demolition of cement concrete (unreinforced) in ground floors (below or above ground level) not exceeding 15cm thickness all as directed by Engr-in-Charge.
26M & L 75mm thick PCC 1:3:6 mix type C2 as in plinth protection and surface to be finished fair without using extra cement .
27M & L for 75 mm thick sub base in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregates) all as specified.
28M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in near cement slurry in floors with grey cement and pigment over 15 mm thick screed bed in CM 1:6
29M & L for sand filling under floors or in foundations including watering and consolidation as in levelling coarse for fixing of interlocking tiles all as specified and directed by Engineer-in-Charge.
30M & L for machine pressed coloured rubber moulded precast concrete interlocking paver block with pigment any shape and size confirming to IS-15658-2006 of 60 mm thickness, M-35 grade all as specified and directed by Engineer-in-Charge.
31M & L for Cement concrete 1: 2:4 type B-1 (20 mm graded stone aggregate) as in edges for Coping.
32M & L cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate ) as in 25 mm thick flooring finished even and rough.
33Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
34M&L non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm,(400x400) in floors etc over and including 15 mm thick screed bedding in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
35M&L non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm,in floors etc over and including 15 mm thick screed bedding in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
36M&L mat finish ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm,in skirting etc over and including 10 mm thick bedding layer in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
37M&L for Glazed ceramic tiles in vertical surface 450x 300x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including 15mm thick bedding layer/ backing coat in CM 1:4 complete all as specified and directed.
38M&L granite (of any type) work ( table rubbed & polished), 18 to 20mm thick, in steps, jambs, pillars, window-cill, cooking platforms & like in cement mortar (1:4) including polishing of chamfered edges and pointing in white cement using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in CM (1:6).
39Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars, walls etc.
40M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:4 all as specified and directed.
41Taking down cement plaster of any description, on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete.
42M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:4 finished even and fair.
43M & L for rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brick-work surfaces of walls in cement mortar 1:6 finished even and fair without using extra cement.
44M & L for rendering 5 mm thick on fair faces of brick work or concrete surfaces of Ceiling in cement mortar 1:3 finished even and fair.
45M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. as specified.
46M & L for prepariation of New plastered surfaces and applying two coats of distemper oil emulsion over a coat of chalk whiting for preparatory to distempering on surfaces of walls.
47M & L for prepariation of New plastered surfaces and applying three coats of white wash on surfaces of ceiling.
48M & L for prepariation and complete removal of old plastered surfaces and applying two coats of distemper oil emulsion over a coat of chalk whiting for preparatory to distempering on surfaces of walls.
49Taking up or down steel water tubing and connecting incl cleaning for refixing or removal to stores for 20mm bore. complete all as specified and as directed
50M&L GI tubes medium grade 20mm bore fixed complete to wall or laid in floor. complete all as specified and as directed.
51Taking up or down steel water tubing and connecting incl cleaning for refixing or removal to stores for 15mm bore.
52S & F GI tubing 15 mm bore medium grade with all fittings & fixed complete to walls or laid in floors.
53Dismantling PVC/RCC water storage tank 500 ltrs & n.exc. 1000 ltrs all as specified
54M&L Rotational moulded polyethylene water storage tanks of 1000 ltr capacity (cylinderical verticla with closed top ) hoised and fixed in position all as specified in SSR part I
55S & F in repairs ball brass valves with brass rod, high pressure with polythelene float and fly nut complete, screwed for iron pipe or for brass ferrule of 20mm dia.
56S & F in repairs 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed.
57S&F in repair Bib taps for 15 mm bore pipe, cast copper alloy fancy type chromium plated fixed in repairs of complete all as spd and directed.
58S & F in repairs 15 mm bore fancy type chromium plated pillar taps cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
59S & F in repairs stop cocks 15 mm bore, chromium plated , fancy type screwed down , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions .
60S & F in repairs wash hand basins, vitreous china( flat back) white of size 550mm X 400mm including cutting for and pinning in ends of brackets or erecting stand including waste coupling fitting, brass chromium plated 32 mm size with long screwed shucks and fly nuts and including PVC discharge pipe as specified.
61S & F PVC connection 15 mm bore size with PTMT nuts and PVC washers of length 450 mm.
62S & F in repair vitreous china wash down water closet (Pedestal) including white PVC seat cover closed pattern with flat bottem and cover and mild steel chromium plated hinge device,connection to drain or outgoing pipe and to flushing pipe, antisyphonage pipe joint to socket or stoper etc, white (EWC).
63S & F in repair single towel rall 450mm long fancy type chromium plated fixed with PVC plug and steel screw complete all as specified and directed.
64S & F in repair towel ring round with round flange fancy type cromium plated fixed with PVC plug and steel screw complete all as specified and directed.
65S & F in repair ap dish, vitreous China white, approximate size 160x 160x90mm complete all as specified and directed.
66S & F in repair Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms ) complete all as specified and directed.
67M & L in repair for hand shower (health faucet) with 8mm dia 1.20 mm lonf flexible tube and wall hook complete all as specified and directed.
68S& F in repair stain less steel decorative cutrain rod of 25 mm bore inluding 2 nos steel finale and bracket 02 nos etc and fixed to wall with plastic rowl plug and steel screw complete all as specified and directed.
69S & F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup wasers with fancy acrylic beading 20 mm wide all around as in repair complete all as specified and directed.
70Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed and removing the material from the site in any mortar all as specified & directed.
7118-20 mm thick Kota stone tiles (Pre-mirror polished), in riser of steps, skirting,dado etc, set and jointed in neat cement slurry and pointed in coloured cement to match tiles including rounding the edges of kota stone over and including 10mm thick backing coat in cement mortar (1:4), surfaces finished even and rough to receive tiles, all as specified and directed.
72S&F in repair 100mm bore sand cast iron soil waste and vent pipes ISI marked in any length with or without ears fixed to walls with clamps and cement joints all as specified.
73S&F in repair 100mm dia CI bends (any radius) diminishing pieces or tapers (larger bore measured) with ovel asses door complete all as specified and directed
74S&F in repair 75mm bore sand cast iron soil waste and vent pipes ISI marked in any length with or without ears fixed to walls with clamps and cement joints all as specified.
75S&F in repair 75 mm dia CI bends (any radius) diminishing pieces or tapers (larger bore measured)
76S&F in repair CI floor trap 100 mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with ot without hole for waste pipe complete all as specified.
77S&F in repair CI floor trap 75 mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with ot without hole for waste pipe complete all as specified.
78S&F in repair cast iron cowl for100 mm dia all as directed by Engr-in-charge.
79S&F in repair cast iron cowl for 75 mm dia all as directed by Engr-in-charge.
80S& F Grating doom 100mm dia of PTMT (Minimum weight 25gms)
81Dismantling wrought iron or mild steel work of any description not otherwise provided for
82Dismantling timber scantlings 40 sq. cm and over in section, in any position
83M&L second class hardwood timber scantling framed and fixed in trusses, rafter, perlin etc.
84S&F Rolled sections as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates etc. complete conforming to Fe-410-W(Gde E-250) quality B.
85S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. .Fe-410- W(Gde E-250)quality-B
86S&F MS Machine made screw bolts with hexagonal or square head at one end and screwed the other each screwed end to be fitted with washers and one hexagonal nut exc 16 and not exc 20 cm long
87S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes,with riveted, bolted or welded attachment Fe-410-W(Gde E-250) quality B.
88Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets
89M & L for false ceiling work of aluminium snap grid system size 605x605mm for false ceiling with aluminium angles of size 23.5 mmx23.5,,x1.5mm fixed to wall with GI screws and aluminium tee of size 37.5x37.5x1.5mm in main and cross runners fixed 60 cm c/c and tied to existing roof/truss/rafters complete
90M & L for hanging of aluminium false ceiling grid with 3 mm dia GI wire(upto necessary required length & 1.2 Mtr c/c) fixed to slopping roof (rafter/purlin/trusses) complete all as specified.
91M & L Non asbestos fibre cement building boards 4 mm thick (one side embosed design), fixed or laid/ inserted to Aluminium grid frame work in ceiling with clips all as specified and directed.
92Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, includingNainital or similar pattern roof coverings.
93S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
94S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.6 mm thick of an colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws as specified.
95S & F 0.63 mm thick galvanised sheet with grade of zince coating 275 in ridges,hips,valley gutters,drip and straight flashings (length and girth as fixed) including cutting, bending to required shape & welding all as specified and as directed.
96M & L preperation of new steel surfaces of any desciption over 10 cm in width or girth not other wise descibed and applying two coats of synthetic enamell paint over a coat of red oxide
97M & L preperation of Old steel surfaces of any desciption over 10 cm in width or girth not other wise descibed and applying two coats of synthetic enamell paint .
98S&F in repairs vitreous china squatting pan 'ORISSA PATTERN ' size 580mm x 440mm 'white with integral foot rest (excluding flushing cistern and flush pipe ) with 'P' or 'S' trap, front or back inlet including connection to trap and to flushing pipe anti syphonage pipe etc complete all as specified and as directed
99Demolition of reinforced cement concrete to Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, parapet and similar suspended work.
100M&L reinforced cement concrete design mix M-20 (using 20mm graded stone aggregate) as in slab, chajja, fins, fascias, louvres,parapets, , newels, balustrade, and the like.
101M&L reinforcement 10mm and over using TMT bars cut to length bent to shape as required including cranking bending spirally for hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia or securig with clips etc complete.
102Use and waste of Formwork to flat faces of slab, chjja, walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter.
103Taking down carefully aluminium/copper point wiring (light,fan,socket power etc) on TW batten/PVC casing capping, surface steel/PVC conduit including all fitting/fixtures and making good disturbed surfaces of wall/floor/ceiling etc to match the adjoining surfaces.
104Overhauling, painting, greasing & refixing of existing ceiling fans & exhaust fans obtained from item no 1 complete all as specified & as directed by Engineer-in-Charge.
105Hanging/ Fixing only ceiling fans of any make & sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed from ceilimg rose to fan connecting & testing, complete all as specified & as directed by Engineer-in-Charge.
106Hanging/ Fixing only Exhaust/cabin/wall fans of any make & sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed from ceilimg rose to fan connecting & testing, complete all as specified & as directed by Engineer-in-Charge.(fan shall be fitted with new set of washers, nuts, rubber reels, shackle etc..,)
107M&L for point wiring complete with two single core, PVC insulated, unsheathed, multi stranded bright annealed copper conductor cable, 1.5 Sq.mm 1100 Volts, FRLS grade drawn through and including heavy duty PVC casing and capping not less than 20 mm width and accessories surface mounted on walls, ceilings etc. on & including PVC board with earth dolly arrangement with surface plate for mounting switches, sockets, regulators etc and one run of 1.5 Sq.mm PVC insulated, unsheathed, multistranded, copper conductor cable FRLS grade as earth wire and connected to common earth dully complete for the following :-(a) One light/fan point controlled by one switch.
108One 3 pin socket out let 5 Amps on independent board.
109One 3 pin socket out let 5 Amps on Same board.
110One bell point controlled by one push button.
111Ditto- all as per Sl item No 107 above but with two runs of 2.5 Sq.mm cable and one run of 2.5 Sq.mm cable as earth wire for one 3 pin socket outlet/power point 15 Amps controlled by one switch.
112Supply & fix switch piano flush type single pole one way 5 Amp.
113Supply & fix switch piano flush type single pole one way 15 Amp
114Supply & fix Socket out let 2 in 1, 5 pin 5 Amps flush type.
115Supply & fix Socket out let 2in1,3 pin 5 and 15 Amps flush type.
116S&F lamp holder PVC/ Poly carbonate type with back plate suitable for batten fitting SP 230 Volts
117S&F ceiling rose,3 phase/ PVC /polycarbonate isolated body,65x50 mm two to three terminals.
118S&F Bell push 5 Amps SP one way suitable for 230 Volts flush type 2 module.
119S&F electric bell Ding Dong AC 230 volts single pole.
120S&F in repairs Fan regulator electronic solid state with various steps variable speed suitable for ceilling fan of size 900 to 1500mm sweep working on 230 V AC supply with all necessary connections.
121Supply & fix in repair decorative ultra slim square profile LED Light fitting of min 20 W rating aluminium housing along with integrated driver, environmental friendly, energy efficient ready to use pack 20W LED 6000K, complete all as specified and as directed by Engineer-in-Charge. Make: Havells or equivalent in Bajaj/CG.
122Supply & fix in repair decorative ultra slim square profile LED Light fitting of min 10 W rating aluminium housing along with integrated driver, environmental friendly, energy efficient ready to use pack 10W LED 6000K, complete all as specified and as directed by Engineer-in-Charge. Make-Havells cat part No Lumiline+BS10WLED865SPCSS or equivalent in Bajaj/CG.
123S&F and connecting up surface mounting decorative bulk head 10 W LED ,energy saving, environmental friendly, long life, corrosion resistant complete with LED and connecting up with and including size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete.Make-Surya (CAT No SLEBH10 W ) or equivalent in Havells/ Philips/Bajaj/Cromton Greaves.
124S&F sheet metal enclosure distribution board 415V, Vertical TPN 4 way with provision for DHx100 series MCCB of Legrand make as incomer & SP/TP MCBs as outgoing as per IS including compact insulated bus bar & rounded neutral bar, door earthing complete double door surface /recess mounting IP-43 protection of L & T Cat NO. DBVTL004GD or equivalent in legrand/siemens, complete all as specified and directed by Engineer-in-Charge.
125S & F Sheet Metal enclosure double door for mounting MCBs with 200 A rated bus bar 8 way AC 240 Volt with IP-43 protection including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge . Make Indoasian/L&T/HPL
126S&F in repairs MCB SP 6-32 Amp.
127S&F in repairs MCB TPN 63Amp.
128S&F in repairs MCB SPN 40 Amp.
129S&F in repairs wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulating copper stranded conductor single core cable in surface/ recesed as required earth wire in and including PVC Casing Caping of suitable standard size of :-Two run of copper conductor of size 6.0 sq. mm + One run of 6.0sq. mm as earth wire.
130Supply and lay in trenches/floor/on wall/ on surface with necessary fixing accesseries LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty)1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 Core including necessary connection with provision of lugs & cable gland fixing arrangements all as specified and directed.
131M&L & fixing of DWC pipes it should be flexible & should allow deformation in diameter as well as In joints under external load & soil natural movement, socket & spigot joint with electrometric sealing ring , it should be highly corrosive resistant & it should be impact resistant, chemiacal resistant, flexible & light weight of size 63 mm dia complete with coupler, elbows, joints,& necessary space parts complete all as specified.
132S&F MCB protected socket including 25 A MCB SP , plug top and MCB SP for AC/Gyser connection all per directed by Engineer in charge. Havells cat part No DBOXX MCB Protected socket 25 A or equvlt in Anchor/Standard..
133S & F Recess mounted LED luminaire with complete diffuser 36 W , 2'x2', Panel Ultra modren recess mounting lumiare high brightness SMD LED as light source 2' x 2 'powder coated CRCA housing, heat sink complete all as specified. Make- havells or equivalent in Bajaj/ Crompton greaves.
134Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI Strip 25 x 4 mm fixing on wall by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-2 and CI cover with frame all as shown in electrical plate No. 5 of SSR part-I all as specified and directed
135Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out soft/loose type soil.
136Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in hard soil.
137Returning Filling in including spreading, leveling, watering & well ramming in layers n. exc 25 Cm.
138Removing excavated/Surplus soil n exc 50 Mtr & depositing where directed at a level n. exc 1.5 Mtr above the starting point.
139M&L & fixing of DWC pipes it should be flexible & should allow deformation in diameter as well as In joints under external load & soil natural movement, socket & spigot joint with electrometric sealing ring , it should be highly corrosive resistant & it should be impact resistant, chemiacal resistant, flexible & light weight of size 103 mm dia complete with coupler, elbows, joints,& necessary space parts complete all as specified.
140Supply and lay in trenches/floor/on wall/ on surface with necessary fixing accesseries LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty)1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core including necessary connection with provision of lugs & cable gland fixing arrangements all as specified and directed.
141Supply & fix in repair ventilating fan made out of high quality engineering plastic, resistant to colour change with anti static properties, 250mm sweep suitable to work on 230 Volts 50 Hz AC supply of Havells: model no VENTILAIR DX or equivalent of CG/Bajaj including connecting to ceiling rose all as required or directed.
142Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all specified and directed,Make- havells or equivalent in Bajaj/ Crompton greaves. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57046469
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 26.60 Lakhs
LAST DATE 07-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Completion Of Balance Work Of Improvement To Bldg No P-48 (Bls) , P-22 (Ration Store ) & P-23 (Tech Hq) At 25 Ed Under Ge (Af) Ojhar
Basic Detail
Tender No 8452/E8
Bidding Type Tender
Location
City Nashik
State Maharashtra
Key Dates
Publish Date 17 Aug 2026
Submission Date 07 Sep 2026
Open Date 09 Sep 2026
Finance
Tender Value 26.60 Lakhs
Tender Fee 500
EMD 53200
Exemption Available
Document List
0e8452c7-d51f-42cb-868f-d039584fb5db.html
BOQ_879222.xls
TENDER8452N.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

0e8452c7-d51f-42cb-868f-d039584fb5db.html

xls

BOQ_879222.xls

pdf

TENDER8452N.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender