Tender For Provn Of 05X Toilet Near Jcos Mess And Or Lines, Provn Of Reception Cum Sentry Post At Main Entrance, Provn Of Shed Along Cook House, Provn Of Ligtning Conductor And Provn Of Earthing, Lightning Arrestor At Barrackpore Under Ge Barrackpore
Tender Overview
Project Description
Tender for Provn Of 05X Toilet Near Jcos Mess And Or Lines, Provn Of Reception Cum Sentry Post At Main Entrance, Provn Of Shed Along Cook House, Provn Of Ligtning Conductor And Provn Of Earthing, Lightning Arrestor At Barrackpore Under Ge Barrackpore
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc 30 cm deep and averaging 15cm deep in soft/loose soil and getting out complete all as specified and as directed. |
| 2 | Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in soft / loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, watering, and removing surplus soil to a distance not exceeding 50 M and making good surface complete all as specified and as directed. |
| 3 | Excavation over area, n. exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 4 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 5 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 6 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 7 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 8 | M&L for hard core with broken stone or boulder of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 9 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as directed. |
| 10 | M&L for PCC 1:4:8 Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 11 | M&L for 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 12 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 13 | M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 14 | M&L for PCC 1:2:4 Type B-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 15 | M&L for 75 mm thick PCC 1:2:4 type B2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 16 | M & L for PCC 1:2:4, type B0 (using 12.5 mm graded crushed stone aggregate) as in coping, cills, fixing of post, water trough etc. including necessary formwork (straight or curved) complete all as specified and as directed. |
| 17 | M & L for 25mm thick PCC 1:2:4, type B0 using (12.5 mm graded crushed stone aggregate) as in floors to receive tiles complete all as specified and as directed. |
| 18 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and as directed. |
| 19 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 20 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in beams, cantilever, lintels over 1.5 m span complete all as specified and as directed. |
| 21 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 22 | M & L for precast RCC cover slab, 1:1.5:3 type A-1,(Using 20 mm graded crushed stone aggregate ) as in drain/manhole cover slab etc., and set in cement mortar 1:4 including necessary form work complete all as specified and as directed. |
| 23 | M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 24 | M & L for mild steel TMT bars 6-8 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 25 | M&L for mild steel TMT bars 8 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed. |
| 26 | Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 27 | Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions (Square, Circular rectangular or polygonal) for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 28 | Use and waste formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressumers, lintels over 1.5m clear span, cantilevers, shelves including supports overhangs etc also splays between floors and beams for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 29 | Use and waste formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings sun shade, chajja, floors, roofs, landings, balconies etc., n exc 200 mm thick (horizontal or sloping) for rough finished surface of concrete complete all as specified and as directed. |
| 30 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 31 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 32 | M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 33 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 100Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 34 | M&L for rendering 5 mm thick in cement mortar (1:3) as in ceiling surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 35 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 36 | M & L for preparation of newly plastered surfaces of walls and applying Two or more coats of 100% Premium exterior acrylic emulsion paint of required shade, having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all specified and as directed. |
| 37 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm using Airless Paint Primer Sprayer using smart technique over 1.5 mm thick (average) wall care putty on newly plastered surface of wall including preparation complete all as specified and as directed. |
| 38 | M & L for preparation of newly plastered surfaces of walls and applying one coat of Chalk whiting, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil bound distemper complete all specified and as directed. |
| 39 | M&L for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant cement primar complete all as specified and as directed. |
| 40 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and as directed. |
| 41 | M&L for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to grade Fe-410-W (Gde E 250 quality A) for fixing complete all as specified and as directed. |
| 42 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 43 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 44 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid in floors etc. over and including 15 mm thick screed bed in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, complete all as specified and as directed. |
| 45 | M&L for coloured non skid ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exc 0.18 sqm but not exceeding 0.38 Sqm on vertical surfaces as skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 46 | M&L for glazed light coloured/printed ceramic tiles 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 47 | S & F factory made solid PVC door frame of size 50mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 48 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 49 | S & F Factory made fully glazed (frosted/ground/obscured)/fully gauged PVC window/ventilator shutter 30mm thick(Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC C Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top and bottom rail on either side and as gap inserted for top and bottom rail(rate including glass panes/gauges) complete all as specified and as directed. |
| 50 | S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed. |
| 51 | S & F 75 mm size stainless steel butt hinges, complete all as specified and as directed. |
| 52 | S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed. |
| 53 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 54 | S & F 250 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed. |
| 55 | S&F floor door stopper of aluminium alloy body and tongue, overall length of cover plate 150 mm anodised with hard drawn steel spring, fixed in floors complete all as specified and as directed. |
| 56 | S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frames for door, windows, ventilators, partitions etc. with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. |
| 57 | S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and as directed. |
| 58 | S & F Powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and as directed. |
| 59 | S & F aluminium door closer (extruded section) body hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and complete all as specified and as directed. |
| 60 | S & F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 61 | S & F 3mm thick figured glass, pinhead type in squares n exc 0.5 sq. m each pane complete all as specified and as directed. |
| 62 | S & F 20mm dia anodised aluminium tubular curtain rod including brackets,stops, rollers complete all as specified and as directed. |
| 63 | S & F 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed. |
| 64 | S&F 25mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel head screwed both ends for iron pipe complete all as specified and as directed. |
| 65 | S&F stop valves, 20mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 66 | S&F stop valves, 20mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender