Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57046446

Tender For Repair/ Maintenance Of Lt And Ht External Electrical Installations And Connected Works At Rayang Mil Stn.

Issued by Statutory Bodies & Commissions/Committees · East Siang, Arunachal Pradesh
Tender Value
39 Lakhs
Estimated cost
Bid Submission
04 Sep 2026
11 days left
EMD
78000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
East Siang → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Lt And Ht External Electrical Installations And Connected Works At Rayang Mil Stn.

BOQ

Name of Work:- REPAIR/ MAINT OF LT AND HT EXTERNAL ELECTRICAL INSTALLATIONS AND CONNECTED WORKS AT RAYANG MIL STN.
Sl. No. Item Description
1Supply and laying (in replacement) cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 150 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing complete all as specified and directed.Note: Excavation and earth work will be measured and paid separately under respective item.
2Supply and laying (in replacement) cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing complete all as specified and directed.Note: Excavation and earth work will be measured and paid separately under respective item.
3Supply and laying (in replacement) cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing complete all as specified and directed.Note: Excavation and earth work will be measured and paid separately under respective item.
4Supply and laying (in replacement) cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4.0 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing complete all as specified and directed.Note: Excavation and earth work will be measured and paid separately under respective item.
5Supply and laying (in replacement) cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2.0 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing complete all as specified and directed.Note: Excavation and earth work will be measured and paid separately under respective item.
6Excavation in trenches for laying under ground cable, erection of poles and stays in any type of soil, not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed by Engr-in-Charge.
7Description all as per BoQ item No. 6.00 here in above but depth exceeding 1.5m and not exceeding 3.00m.
8M&L for Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified by Engr-in-Charge.
9Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed by Engr-in-Charge.
10Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed by Engr-in-Charge.
11Removing surplus excavated soil to a distance not exceeding 50m and depositing at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information
12Removing surplus excavated soil to a distance not exceeding 50m and depositing at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57046446
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 39 Lakhs
LAST DATE 04-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Lt And Ht External Electrical Installations And Connected Works At Rayang Mil Stn.
Basic Detail
Tender No 83103/E8
Bidding Type Tender
Location
City East Siang
State Arunachal Pradesh
Key Dates
Publish Date 14 Aug 2026
Submission Date 04 Sep 2026
Open Date 07 Sep 2026
Finance
Tender Value 39 Lakhs
Tender Fee 500
EMD 78000
Exemption Available
Document List
1677df54-3215-4711-b17d-5e36c16cceb3.html
BOQ_879060.xls
Tenderdocuments83103.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

1677df54-3215-4711-b17d-5e36c16cceb3.html

xls

BOQ_879060.xls

pdf

Tenderdocuments83103.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders