Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #57046422

Tender For External Repairs Including Roof Treatment And Periodical Services To The Buildings At Bairagarh Under Ge Bhopal

Issued by Statutory Bodies & Commissions/Committees · Bhopal, Madhya Pradesh
Tender Value
45 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
6 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for External Repairs Including Roof Treatment And Periodical Services To The Buildings At Bairagarh Under Ge Bhopal

BOQ

Name of Work:- EXTERNAL REPAIRS INCLUDING ROOF TREATMENT AND PERIODICAL SERVICES TO THE BUILDINGS AT BAIRAGARH UNDER GE BHOPAL
Sl. No. Item Description
1Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline
2S&F in repairs PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints laid in trenches , floors or fixed in walls complete all as specified and directed.
3S&F PVC (SWR) 110mm bore bends any radious complete.
4S&F PVC (SWR) 110mm bore single T any radious complete.
5Dismantling of timber scantling in fillets, rails, posts, rafters, purlins etc 40 sqcm and over in section, in any posotion for unframed works complete all as specified.
6S&F steel work in tubular/angle trusses including special shaped washers, purlins, rafters, posts etc complete all as specified and directed.
7M&L Pre Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick AZ-150 of an colour having tensil strength of 550/MPA as in roof covering/cladding to wall/ ridge,fixed with self tapping screw/L type or J type cranked hook bolts including dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering. complete all as specified and directed.
8M&L Pre Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick AZ-150 of an colour having tensil strength of 550/MPA as in roof covering/cladding to wall/ ridge,fixed with self tapping screw/L type or J type cranked hook bolts including dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering, complete all as specified and directed.
9M&L for preparation of old existing roof surface by washing rubbing down removing oil grease and vegitation etc. and applying ready made branded chemical treatment of approved OEM to roof/ exterior wall/ parapet wall/ chajjas and any other position as per site requirement complete all as specified and as directed in following steps:- Step-1 Opening of sealed container and dilute the chemical with water @ 1:3 using mechanical mixer to prepare primer and apply one coat of primer using roller and allow 4-6 hrs to dry for primer.Step-2 Apply two coats of approved chemical roof treatment with roller to primed surface as per manufacturer's instruction anda allow 4-6 hrs to dry treatment. Note :- (1) Removal of old roof treatment work is deemed to be included in rates(2) work shall be got executed only from approved OEM.Make:- Asian Smart Care Damp Proof / Berger Weather Coat Roof Guard / Nerolac Perma No Damp
10M & L for complete removal of existing treatment on wall and applying 1mm thick water proof putty over prepared surface. Complete all as specified and as directed.
11M&L for preparing and applying Dr. Fixit rain coat in following steps as appended below:-(1) Existing substrates cleaned and removed all scale dirt, algea moss, fungal growth with high pressure water using high pressure jet washer. All loose plaster will be repaired with polymer modified mortar using Dr. Fixit pidicrete URP and norrow cracks upto 5mm shall be repaired with crack X-paste and the larger cracks upto 10mm with Dr fixit crack-X shrink free. The surface shall be made dry completely for upto 4-6 days for application of primer.(2)Applying one coat primer Dr. Fixit prime seal diluted with 2:1 with water (prime seal:water) maintaining spreading rate @ 8 to 10 sqm / ltr complete all as specified and directed. (3) Applying two coats of Dr Fixit raincoat without any dilution for coverage 3.5 sqm/ltr and second coat of Dr. fixit rain coat without any dilution for coverage 7 sqm/ltr complete all as specified and directed.Note :- (i) Second coat must be applied after lapse of 6 to 8 hours application of first coat.(ii) The application of Dr Fixit raincoat must be avoided at temperature below 10˚C more than 35˚C and in direct sunlight.
12M&L for provn of water proofing roof treatment to non accessible /accesible RCC roof with APP modified membrane with non woven polyster reinforced wt not less than 3 Kg/Sqm of thickness not less than 3 mm having thermal; insulation with white or plain finish on upper side of membrane uniformely embedded during manufacturing process including taking down existing treatment all as per following specifications:-(a) 10 mm thick plaster in CM 1:4 mixed with and including water proofing compound @3% by weight of cement applied over roof slab. After the plaster is cured the roof will be tested for water tightening by ponding with water for 72 Hrs for any seepage / leakages etc. if any seepage is oberved the rectification will be carried out by pressure grouting under the pressure of 5 Kg/Sqcm using cement based cement grout. After the surface is repired the slab will be tested for watertightness against before processing further treatments. (b) The surface of the roof, parapet and gutters, drain mouths etc. over which water proofing treatment is to be applied shall be cleaned of all foreign matters such as fungus, mass, dust etc. by wire brushing and dusting. For cast iron drain outlets the groove shall be cut around to tuck in the treatment as pipes, chimney stacs etc. and other similar situations to ease up about corners.(c) Hot blown bitumen VG-10 as in primer conforming to IS : 3384-1965 @ 0.30 Kg/Sqm to be applied on prepared surface till the surface is properly impregnated.(d) APP modified water proofing membrene as specified shall be laid by torch application method laid on hot bitumen 85/25 grade(bonding material) at the rate of 1.2 kg/sqm primer surface as per manufacturers instructions, The overlaps while torching shall be 100 mm in both directions(longititudinal and transverse directions). All overlap joints shall be sealed throughly by thermofusing both the membrene layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer. (e) All joints & changes in direction should be curved with cement morar 1:3 mixed with SBR latex @ 200 ml per beg of cement and cured well before laying the membrane.(f) A fillet of PCC (1:2:4) type B-0 of 100 mm x 100 mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of direction. The membrane should not be taken over at any steep turns and hence all corners /junctions should be rounded.
13M&L for 15mm thick rendering in cm 1:4 faces of brick or concrete surfaces(External surfaces) mixed with water proofing compound @ 3% by wt of cement , finished fair, even and smooth without using any extra cement including taking down cement plaster on brick or stone wall etc including raking out joints, hacking for key, scrubbing down with water or cement lime plaster any description.complete all as specified and directed. (Note :- Water Proofing compound shall be measured and paid seperately)Note :- Rate is inclusive of scaffolding upto height of 12 m.
14M&L for repair of damaged RCC columns, beams etc incl chipping of loose concrete, cleaning of exposed reinforced, fixing of GI wire mesh using binding wires/nails, and recasting in cement concrete 1:2:4 type B-0 and finished the concrete surface with 10mm thick rendering in cm 1:3 and apply two coats of OBD/Exterior emulsion which ever is applicable.complete all as specified and as directed. Note :- (a) Rates are deemed to be included with necessary formwork. (b) GI netting and wire will be measured and paid separately.
15Supply only GI wire netting made of 0.9mm dia galvanised iron wire with 12mm x12mm square mesh. Complete all as specified.
16Integral water profing compound mixed with cement mortar complete all as specified and directed.
17Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over new surfaces incl prep of new surface. complete all as specified and as directed.
18M & L for Complete removal of existing treatment on wall (Internal/External) /chajja/roof projections including facias, cornices etc by scrapping with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc) & (External surface by washing/cleaning down with water) by skilled labour including filling holes, cracks, depressions of scraped surfaces with putty and preparation of surfaces for further treatment. Necessary scaffolding suitable for height upto 10.00 mtr from average ground level, complete all as specified and directed.
19M&L for applying one coat of white wall putty 1mm thick on walls complete all as specified and directed.
20M & L for applying Two coats Exterior weather proof emulsion paint of 100% Premium acrylic emulsion paint on old prepared wall surfaces incl chajja, patta etc. having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Water, Alkali & Fungal resistance, dirt resistance of required shade with silicon additives @ 1.43 litre/ 10 sqm over and over a coat of priming coat of exterior primer applied . Necessary scaffolding suitable for height upto 10.00 mtr from average ground level complete all as specified and directed.
21M&L for one coat of acrylic water based interior/exterior grade primer @ 0.90 litre/ 10 sqm or as per manufacturer instruction applied with fully automatic airless spray machine and allow to dry the surface 6-8 hrs all as specified and directed.
22M&L for applying one coat of oil bound distemper emulsion on old prepared wall surfaces including window & door jambs, cills, cornices etc. having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete all as specified and directed.
23All as per item No. 27.00 herein before but Two coats of oil bound distemper emulsion on old prepared wall surfaces incl window & door jambs, cills, cornices etc. complete all as specified and directed.
24M&L for one coat of acrylic water based interior/exterior grade primer @ 0.90 litre/ 10 sqm or as per manufacturer instruction applied with fully automatic airless spray machine and allow to dry the surface 6-8hrs complete all as specified and directed.
25Deduct Schedule of credit (calculation will be done off line) Rs. 16850.00 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57046422
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 28-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for External Repairs Including Roof Treatment And Periodical Services To The Buildings At Bairagarh Under Ge Bhopal
Basic Detail
Tender No 8638/E8
Bidding Type Tender
Location
City Bhopal
State Madhya Pradesh
Key Dates
Publish Date 14 Aug 2026
Submission Date 28 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
7f4bfc95-5238-4708-884e-acb1aae5be2c.html
BOQ_879196.xls
credit8638.pdf
Tendernotice_1.pdf
TENDER_DOCU_8638.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

7f4bfc95-5238-4708-884e-acb1aae5be2c.html

xls

BOQ_879196.xls

pdf

credit8638.pdf

pdf

Tendernotice_1.pdf

pdf

TENDER_DOCU_8638.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders