Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #57046421

Tender For special Repair Or Living Bathrooms At Bldg No P-39,P-40 And P-41 Of 12 Engr Rgt At Dinjan Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Tinsukia, Assam
Tender Value
44.90 Lakhs
Estimated cost
Bid Submission
03 Sep 2026
9 days left
EMD
89800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair Or Living Bathrooms At Bldg No P-39,P-40 And P-41 Of 12 Engr Rgt At Dinjan Mil Stn

BOQ

Name of Work:- SPL REPAIR OR LIVING BATHROOMS AT BLDG NO P-39,P-40 AND P-41 OF 12 ENGR RGT AT DINJAN MIL STN
Sl. No. Item Description
1B/R WORKS :Demolition of cement concrete in ground floor n exc 15 cm thick (un reinforced) complete all as specified and directed.
2M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in chajjas top, laid to a minimum consolidated thickness of 25 mm as leveling course, laid and compacted in min slope 1:30 over top of chajja complete all as specified and directed.
3Taking down chowkats or frame, n. exc 1.5 sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
4S&F solid PVC moulded door frame of size 50mmx47mm made out of 5mm, single side prelam PVC sheet used and edges will be painted to match with printed to match with prelam sheet, reinforced with MS square tube & fixing in opening including hold fast complete all as specified and directed.
5S&F factory made solid PVC Moulded door shutter 28 to 30mm thick (Stiles) with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on front face & 2 mm plain colour PVC sheet on back face, supplying and fixing in frame at site complete all as specified and directed.
6S&F 100 mm size stainless steel butt hinges medium weight cold rolled complete all as specified and directed.
7Supply and fix for 150mm long aluminium handles, cast type, anodised complete all as specified and directed.
8Supply and fix in for 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
9M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 or E-165 complete all as specified and directed.
10S&F powder coated aluminium anodised frame for doors, windows etc with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
11S&F Anodised aluminium powder coated window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including all necessary fittings like hinges joining cleats, glazing clips,moving roller, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
12Supply and fixing of aluminium sliding window with powder coating (minium thickness of powder coating 50 micron) including following components / specification complete all as specified and directed. (i) Thickness and weight per metre length of aluminium frame and section of shutter all as shown on drawing. (ii) All vercal/ horizontal joint shall be of extruded aluminium section so as to avoid any play between jointed members. (iii) all other accessories such as jointing cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, srews, etc. (iv) Stainless steel wire cloth, 036 mm nominal dia of wire and average width of aparture 1.40 mm and fixed with stainless steel wire staples, etc. (v) Sheet glass 4 mm thick selected quality tinted/black glass and glazing with oil putty or fixed with wooden beads in square not exceeding 0.5 Sqm in each pane (vi) Rest all as specified in drawing no CEZ/2015/TD/007 Sheet no 1R/5, 2R/5, 3R/5, 4R/5, 5R/5. Note :- Grill shall be measured and paid separately.
13Supply & fixing Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening,complete all as specified and directed.
14Supply and Fixing only 4mm thick figured glass pin headed type and glazing with oil putty in square n.exc.0.50 Sqm in each pane complete all as specified and directed.
15Material and labour for providing and injecting chemical emulsion for post constructional anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion at the rate of 2.25 litre peri linear metre including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 Cement : 2 Coarse sand) to match the existing floors drilling and plugging holes etc complete all as specified and directed.
16M & L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
17Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
18Dismantling of stone slabs or tiles of any description or thickness as in floors, pavings, aprons, pathway etc laid dry or laid dry and pointed complete all as specified and directed.
19M & L 25 mm thick PCC type B0 1:2:4 (using 12.5 mm graded stone aggregate) as in leveling complete all as specified and directed.
20M&L for Non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm (400X400X7mm) in floor, over 20mm thick screed bed in CM 1:4 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified and directed.
21M&L Non skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm 7mm thick coloured tiles in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over screed bedding 15mm thick in CM 1:4 complete all as specified and directed.
22M&L for glazed ceramic tiles in vertical surface 300x450x7mm thick in dado over 10mm thick screed bed in CM 1:4 on walls set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified and directed.
23M & L 75 mm thick PCC type D-2 1:4:8 ( using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
24M& L for Marble work 18-20 mm thik(table rubbed and polished) (Colour- Green) in steps, jambs, pillars, window cills, cooking platforms and like in vertical surfaces in/over 10 mm thick screed bed of cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble of any shade other than white and black complete all as specified and directed.
25Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
26Material & Labour for Brick work with sub class ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) complete all as specified and directed.
27M&L for half thick brick work with sub class \\"B\\" bricks straight or curved on plan exceeding 6m mean radius with old size bricks locaaly available built in cement mortar 1:4 complete all as specified and directed.
28Taking down cement plaster on brick walls/ concrete surface, etc. including raking out joints, hacking for key, scrubbing down with water, etccomplete all as specified and directed.
29M&L 15 mm thick cement plaster on wall in CM (1:6) on fair faces of brick work incl finished even and smooth without using extra cement complete all as specified and directed.
30M&L 15 mm thick cement plaster in CM (1:4) on wall ( with approved water proofing compound) on fair faces of brick work incl finished even and smooth without using extra cement complete all as specified and directed.Note: 1. WPC @ 200ml for 50 Kg cement, will be paid separately.2. The rate quoted by contractor is deemed to be included necessary scaffolding and formwork as required upto 7.00 Mtr height building.
31M&L 5 mm thick cement plaster in CM (1:3) on ceiling surfaces incl finished the surface even and smooth without using extra cement complete all as specified and directed.
32M&L for applyiing 15mm plaster with polymer modified mortar fortified with SBR(Nito Bond SBR 45) in proportion 1:3 by weight 5 litr Nitobond SBR 45 added to 50kg cement with 13 litr water and finished surfaces to existing adjoining surface of ceiling, columns, beam and like etc complete all as specified and directed
33Supply only Liquid water proofing compound complete all as specified and directed.
34M & L preparing newly plastered surfaces of wall and applying three coats of white wash complete as specified and directed.
35M & L preparation of old decorated surfaces of walls and applying two coat of white wash complete as specified and directed.
36M&L for preparation of new plastered surface of wall Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over 1mm thick plaster of paris putty on new surfaces complete all as specified and directed.
37M&L for complete removal of existing treatment inclpreparation of old surfaces, scrubing down, washing etc from walls by scrapping with mechanical wall sander (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc. and applying two coats of 100% premium Acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistant as per IS-15489:2004 alkali and fungal resistant exterior paint of required shed (company depot tinted) with silicon additives 1.43 litrs/ 10 Sqm over and including primer coat of exterior primer applied 0.90 litre/10 Sqm over new surfacesincl 1mm thick plaster of paris putty, using Airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and will execute the same work by authorised applicator as mentioned in PS and acessories complete all as specified and directed.
38M&L preapring old plastered surfaces incl washing rubbing down and stopping of distempered and painted surface of ceiling and applying two coat of white wash complete all as specified and directed.
39M&L for Preparation of new plastered surfaces and applying three coat of white wash on ceiling complete all as specified and directed.
40M&L for applying two coat of Synthetic enamal paint over a coat of red oxide primer on new steel based surfaces exc.10cm width or girth including preparation complete all as specified and directed.
41M&L for 75 mm thick plain cement concrete (1:3:6) Type C2 using 40 mm graded aggregates as in plinth protection/paving including finishing surface even and fair without using extra cement complete all as specified and directed
42Forming Construction joint 30mm deep x 10mm wide filled with sealing compound, Grade ‘A’ complete all as specified and directed.
43Material and labour rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening etc. confirming to Fe 410-W (gde-E-250) quality-A and fixing complete all as specified and as directed.
44Taking up or down 15mm dia steel tubing & connection including cleaning for refixing or removal to store complete all as specified and directed.
45Taking up or down 20mm dia steel tubing & connection including cleaning for refixing or removal to store complete all as specified and directed.
46Refixing 15mm old steel tubing and connection in new or old position (wall, ceiling, floors, etc.) complete all as specified and directed.
47S & F steel tubing 15mm bore medium grade galvanised with all fittings and fixed complete to wall, ceilings or laid in floors complete all as specified and directed..
48Refixing 20mm old steel tubing and connection in new or old position (wall, ceiling, floors, etc.) complete all as specified and directed.
49S & F steel tubing 20 mm bore medium grade galvanised with all fittings and fixed complete to wall, ceilings or laid in floors complete all as specified and directed.
50Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing and making good , cutting not exc 10cm girth complete all as specified and directed.
51Supplying and laying 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
52S&F in repairs for MS grating CP 75/100mm dia, without hole and with hole for waste pipe of approved make including fixing with CM to floor/nahani traps etc complete all as specified and directed.
53S & F in repairs 15 mm bore Bip taps, Chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
54S&F wall mixer with L bend with provision for over head shower complete all as specified and as directed.
55S & F in repairs, stop valves, 15 mm bore cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
56S & F in repairs, 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed.
57S&F in repair Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
58S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position v
59S&F in repairs stainless steel peg set of 6 peg, 45 cm long, complete all as specified and directed.
60S&F in repair soap dish of stainless steel fixed to wall with chromium plated brass screws complete all as specified and directed.
61S&F in repairs flexible (coil shaped) PVC waste pipe for sink and wash hand basin 32/40mm dia, length not less than 70 cm, connected to PVC waste coupling/fittings complete all as specified and directed.
62S & F in repairs, 10 litres capacity PVC valveless syphonic action type, flushing cistern (ISI marked), low level with inlet, ball valve, float bracket & flush pipe complete all as specified and directed.
63S&F in repairs vitreous china under counter basin size 560 x 450 x 185 mm shape ovel of Somany Cat No SKU: 17111025001101 or equivalent of PARRYWARE / JAQUAR / SOMANY / PRAYAG as approved by GE including 32 mm CP waste coupling & PVC flexible waste pipe of 90 cm long complete all as specified and directed.
64S & F 15 mm bore pillar taps, cast copper alloy, chromium plated, fancy type with capstan heads, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
65S&F for Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) front or back inlet including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, etc and making good to floor complete as in repair complete all as specified and directed.
66S & F in repairs, vitreous China squatting pan, 'Orissa' pattern, size 580mm x 440 mm, white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and directed.
67S&F in repairs plastic water closet seat cover white closed pattern with flat bottom and mild steel CP or aluminium hinging device complete all as specified an directed.
68S&F in repair for Vitreous China urinals, half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing grating and Union for discharge pipe incl CP 40mm waste coupling and PVC 40mm waste pipe 900mm long complete all as specified and directed.
69S&F in repair Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
70Supply 32mm dia high density polyethylene (HDPE) pipes of pressure rating 6Kg/Sq. cm laid in floor or fixed to walls including taking down old pipes complete all as specified and directed.
71Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including taking down existing water tanks complete as specified in SSR Part-I complete all as specified and directed.
72S & F in repair 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 210 gms) complete all as specified and directed.
73S&F as in repairs for Gun metal gate valves with iron wheel headscrewed both ends for iron pipes or for unions for 20 mm bore pipes, complete all as specified and directed.
74S & F in repairs 600 x 450mm beveled edged mirror or selected qualtity glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup and washers complete all as specified and directed.
75S & F in repair looking mirror of selected quality glass, size 2.40 mtr long and 0.70 mtr height, mounted on 6 mm thick AC building board or commercial plywood with fancy wooden beading as per sample and fixed to woodden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
76S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
77M& L for PVC (SWR) floor trap 100 dia, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
78M& L for PVC (SWR) floor trap 75 dia, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
79M&L for water proofing treatment on RCC roof etc. comprising with the following operation complete all as specified and directed herein below:- (a)Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100 m n.exc.250m. (b) M&L 25 thick cement concrete type B0 1:2:4 (12.5 mm graded aggregate) finished even and smooth. (c) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight). (d) M&L for 20 mm thick screed bed in cement mortar 1:4 finished even and smooth.(e) Preparing & cleaning of fully dried cement plastered surface. (f) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384. (g) A layer of APP based polymeric membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (h) One coat of aluminium paint over APP membrane @0.11Kg/Sqm.Note:- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab.
80M&L for special treatment for sunken portion of WCs/Bath & toilet executed in following stage complete all as specified and directed.:- Stage1:- Demolition of wc including lime concrete and cemennt concrete etc and preparing of surfaces of existing sunken portion of wc`s or bath etc with wire brush to removed all loose dirts, oil grease etc including removing debries from site of work etc. Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per manufacturere`s instructions. Stage 3:- Apply Dr. Fixit Premeseal primer or equivelent of STP Ltd (and allow to dry for 8 hrs) all as per manufacturer`s instructions. Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 micron or shilicry 215 of STP (The surfaces after painting one coats shall be allowed to dry for 6 hrs before next coats) Stage 5:- Rendering 10mm thick in CM 1:3 mixed with integral water proofing chemical of Dr Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per manufacturere`s instructions. Stage 6:- All CI joints shall be filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr. Fixit pidicrete URP all as per manufacturer`s instructions. Stage 7:- Making holes in walls and fixing 600mm long 40mm dia medium grade GI spouts for draining of excess water if any. Stage 8:- Carryout ponding testfor 48 hrs to ensure water tighteness of repaired sunken portion and filling of sunken portion for cement concrete Type E2, 1:5:10 using 40mm graded stone aggregate as in lean concrete complete all as specified and directed. Note:- only plan area shall be measured for payment under this items. (b) Depth of suken portion of WC`s/ bath shall be upto 35 CM which is to be taken into account while coating the rate against this item. (c) The rate shall be quoted by contractor shall be deemed to be included for all the horizontal and verticl treated surface of sunken portion of WC`s/baths.
81M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
82Demolition of reinforced cement concrete of any description and in any position (reinforcement cut as required to facilitate demolition) all as specified & as directed.
83Material and labour for RCC (1:2:4) type B-1 (using 20 mm graded broken stone aggregate) as in slab supported on walls, beams and column in floors, roof landings, balconies, canopies, deck slabs and in shelves complete all as specified and as directed. (Note : Reinforcement shall be measured and paid seperately under relevant)
84Material and labour TMT bar 10 mm and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
85Use and waste formwork to soffits of suspended slabs such as roof slab, floor slabs, landing covers, and similar works, for rough finished flat surfaces of concrete, thickness of slab not exc 200 mm, complete all as specified and directed.
86Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
87Demolition and breaking up 150 mm bore drain pipes, salt glazed stone ware set in cement mortar including PCC haunching and bedding, complete all as specified and directed.
88S&F salt glazed stone ware drain pipes of 150mm bore, grade `A’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified and directed.
89M&L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in bedding to SGSW/NP2 drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe complete all as specified and directed.
90M&L for cutting into existing manholes / Septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 150mm bore pipe complete all as specified and directed.
91S&F for 50mm thick steel fibre reinforced (SFRC) man hole cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 5 ton/Sqm in square, rectangular shape of size 300X300, 450X450, 600X600 complete all as specified and directed.
92S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints laid in trenches or in floors complete all as specified including dismantling of PCC & taking out old unserviceable 110mm bore PVC pipe with fittings & making good disturbed area complete all as specified and directed.
93S &F for PVC (SWR) pipes single soketed, in any length with rubber ring joints, fixed to walls, 110mm bore pipes complete all as specified and directed.
94S &F for PVC (SWR) pipes single soketed, in any length with rubber ring joints, fixed to walls, 75mm bore pipes complete all as specified and directed.
95S & F for PVC (SWR) bends any radius with access door, 110mm bore complete all as specified and directed.
96S & F for PVC (SWR) bends any radius, 110mm bore complete all as specified and directed.
97S & F for PVC (SWR) vent cowl, 75mm bore complete all as specified and directed.
98S & F for PVC (SWR) bends any radius, 75mm bore complete all as specified and directed.
99S & F for PVC (SWR) bends any radius with access door, 75mm bore complete all as specified and directed.
100S&F PVC(SWR) Vent cowl 110mm diacomplete all as specified and directed.
101E/M WORKS :Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets,sunken type box etc.and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and directed.
102Taking down carefully MCB DBs any type and size by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed. Please Enable Macros to View BoQ information
103Taking down carefully MCB DBs any type and size by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57046421
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.90 Lakhs
LAST DATE 03-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair Or Living Bathrooms At Bldg No P-39,P-40 And P-41 Of 12 Engr Rgt At Dinjan Mil Stn
Basic Detail
Tender No C/8185/E8
Bidding Type Tender
Location
City Tinsukia
State Assam
Key Dates
Publish Date 14 Aug 2026
Submission Date 03 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 44.90 Lakhs
Tender Fee 500
EMD 89800
Exemption Available
Document List
8edb3a7b-1de9-4af9-86ff-ac0bd94c5a91.html
BOQ_879199.xls
finaltender8185.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

8edb3a7b-1de9-4af9-86ff-ac0bd94c5a91.html

xls

BOQ_879199.xls

pdf

finaltender8185.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders