Tender For Supply, Installation, Testing And Commissioning Of Machineries And Accessories For Pack House
Tender Overview
Project Description
Tender for Supply, Installation, Testing And Commissioning Of Machineries And Accessories For Pack House , Supply, Installation, Testing And Commissioning Of Machineries And Accessories For Pack House , Forclips , Box Packing Machine , Plastic Pallet (1100 X 1100 X 120 Mm) Dimensions: 1100 X 1100 X 120 Mm , Floor Washing Machine: , 200 Kg Weighing Balance: • Maximum Capacity: 200 Kg • Readability / Accuracy: Min. 10 G To 20 G • Minimum Weighing Capacity: Min. 60 G To 100 G • Platform Material: Heavy-Duty Mild Steel (Ms) Or Stainless Steel (Ss 304)Platform • Dimensions: 400 × 400 Mm To 600 × 600 Mm (Approx. 16 × 16 To 20 × 20 Inches) • Display Type: Dual-Side (Front And Back; Ultra-Bright Red Led Or Lcd • Power Supply: 220V Ac Main With A Built-In Rechargeable Battery (Typically 6V 4Ah) • Battery Backup: Up To 20 To 40 Hours Of Continuous Usage • Load Cell: High-Precision Single Or Multi-Load Cell Setup • Safe Overload Capacity: Up To 150% Of Rated Load • Operating Temperature: -10°C To 40°C • Calibration / Stamping: Governed By Legal Metrology Department Standards , 20 Kg Weighing Balance: • Maximum Capacity (Max): 20 Kg • Minimum Capacity (Min): Usually 20 G To 100 G • Readability / Resolution: Ranges From 1 G (Standard Commercial/Lab) To 0.2 G Or 0.1 G (High-Precision) • Accuracy Class: Typically Oiml Class Iii Or Class-Iii • Linearity: ± 1 G To ± 2 G • Measurement Time: Fast Response, Usually 1 To 3 Seconds • Platform Size: Ranges From 175 × 225 Mm To 400 × 400 Mm • Overload Protection: Safe Overload Capacity Typically Up To 150% - 200% Of The Rated Weight • Calibration: Fully Automatic Internal Calibration Or Manual Adjustment With Standard Calibration Weights • Power Source: 220V/240V Ac Mains Power • Battery: Built-In Rechargeable Lead-Acid Or Lithium-Ion Battery (Usually 6V/4Ah) • Battery Backup: 10 Hours To Up To 2-3 Days Of Continuous Standby , 304 Ss Table Of Size 2 X 1 X 0.8 M: , 202 Ss Table Size 2 X 1 X 0.8 M , Equipment For Quarantine Room , Plastic Crates 10 Kg , Providing And Fixing Dock Leveler , Supply, Loading-Unloading, Erection, Installation, Testing, Commissioning And Training: Supply, Loading-Unloading, Erection, Installation, Testing, Commissioning And Trial Run Shall Be Included. Training For Operators Shall Be Provided. Operation & Maintenance Manual Should Be Provided.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing and Commissioning of Machineries and Accessories for Pack house |
| 2 | Forclips |
| 3 | Box Packing Machine |
| 4 | Plastic Pallet (1100 x 1100 x 120 mm)Dimensions: 1100 x 1100 x 120 mm |
| 5 | Floor Washing Machine: |
| 6 | 200 kg Weighing Balance:• Maximum Capacity: 200 kg• Readability / Accuracy: Min. 10 g to 20 g• Minimum Weighing Capacity: Min. 60 g to 100 g• Platform Material: Heavy-duty Mild Steel (MS) or Stainless Steel (SS 304)Platform• Dimensions: 400 × 400 mm to 600 × 600 mm (approx. 16 × 16 to 20 × 20 inches)• Display Type: Dual-side (front and back; Ultra-Bright Red LED or LCD • Power Supply: 220V AC main with a built-in rechargeable battery (typically 6V 4Ah)• Battery Backup: Up to 20 to 40 hours of continuous usage• Load Cell: High-precision single or multi-load cell setup• Safe Overload Capacity: Up to 150% of rated load• Operating Temperature: -10°C to 40°C• Calibration / Stamping: Governed by Legal Metrology Department standards |
| 7 | 20 kg Weighing Balance:• Maximum Capacity (Max): 20 kg• Minimum Capacity (Min): Usually 20 g to 100 g• Readability / Resolution: Ranges from 1 g (standard commercial/lab) to 0.2 g or 0.1 g (high-precision)• Accuracy Class: Typically OIML Class III or Class-III• Linearity: ± 1 g to ± 2 g• Measurement Time: Fast response, usually 1 to 3 seconds• Platform Size: Ranges from 175 × 225 mm to 400 × 400 mm • Overload Protection: Safe overload capacity typically up to 150% - 200% of the rated weight• Calibration: Fully automatic internal calibration or manual adjustment with standard calibration weights• Power Source: 220V/240V AC Mains power• Battery: Built-in rechargeable lead-acid or lithium-ion battery (usually 6V/4AH)• Battery Backup: 10 hours to up to 2-3 days of continuous standby |
| 8 | 304 SS Table of Size 2 x 1 x 0.8 m: |
| 9 | 202 SS Table Size 2 x 1 x 0.8 m |
| 10 | Equipment for Quarantine Room |
| 11 | Plastic Crates 10 Kg |
| 12 | Providing and Fixing Dock Leveler |
| 13 | Supply, Loading-Unloading, Erection, Installation, Testing, Commissioning and Training:Supply, Loading-Unloading, Erection, Installation, Testing, Commissioning and Trial Run shall be included. Training for operators shall be provided.Operation & maintenance manual should be provided. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender