Tender For Work Of Repairing Of Electric Panel / Starter Of Various Uwss In Jurisdiction Of Phed Dn. Nagaur
Tender Overview
Project Description
Tender for Work Of Repairing Of Electric Panel / Starter Of Various Uwss In Jurisdiction Of Phed Dn. Nagaur
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Aug-2026 | Date and Time 42/26-27 EE Nagaur | Date | 24-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Labour charges for removing electric fault in wiring / making connection through lugs (with the help of cramping tools) of motor pump set with starter at headworks of water supply scheme / tubewell / openwell including cost of insulation taps etc. |
| 2 | Labour charges for replacement of defective ampere meter / volt meter with new one on existing panel board in pump house./Tubewell /openwell (new voltmeter/ampere meter will be provided by department |
| 3 | Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) |
| 4 | 5 to 15 HP. |
| 5 | 16 to 30 HP. |
| 6 | 31 to 60 HP. |
| 7 | 61 to 100 HP. |
| 8 | 101 to 150 HP. |
| 9 | Supply & filling starter oil in oil immersed starters at site. |
| 10 | SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . With Thermal Magnetic release |
| 11 | 200 Amp, 35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu |
| 12 | 250 Amp, 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu |
| 13 | 400 Amp,50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu |
| 14 | Providing & Fixing of (up to 500) V range Volt meter moving iron AC voltmeter of class 1.5 accuracy as per IS : 1248 on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 15 | Below 500 A |
| 16 | Above 500A |
| 17 | Providing & Fixing of (up to 500) V range Volt meter moving iron AC voltmeter of class 1.5 accuracy as per IS : 1248 on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 18 | Analog type ( 96 mm x 96 mm ) flush mounting |
| 19 | Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 20 | 24 to 40 Amp |
| 21 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 22 | 25.0 Sq.mm, 3.5 core |
| 23 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, RUIDP 459 SOR 2022 Code No Description Unit Rate Rs. auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3 pole Power contactors with following AC 3 Rating |
| 24 | 40 Amp. |
| 25 | 50 Amp. |
| 26 | 70 Amp. |
| 27 | 250 Amp. |
| 28 | Providing & Fixing of ISO certified company made 240/415 V porcelain kitkat fuse (/HBC type) as per PWD specification for electrical Works conforming to IS:2086,1983 on existing board/ sheet including making connections with lugs, testing etc. as required . Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with |
| 29 | 100 A ,415 |
| 30 | 200 A , 415 V Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 26 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender