Banking and Finance Government Departments Closing in 10 days TDR #57043339

Bids Are invited for Sitc Of Hiwall And Cassette Air Condition Systems

Issued by Government Departments · Kolkata, West Bengal
Tender Value
25.36 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
10 days left
EMD
21500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
574

Project Description

Bids Are invited for Sitc Of Hiwall And Cassette Air Condition Systems Sitc Of 1.5 Tr Hi-Wall Split Systems - Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating, Minimum Value Of Iseer 5.6 , Sitc Of 2.0Tr Cassette Type Split Systems - Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(Idu), Out Door Unit (Odu), R-32/R410a/R-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230V, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (Idu To Odu), Copper Power Andcontrol Cable Upto 5.5 Mtr (Idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,Dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/Rotary Compressor With Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is -1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (Nabl) Accredited As Per International Electrotechnical Commission (Iec) 17025 Standards/Central Power Research Institute (Cpri)/ Electrical Research And Development Association (Erda)With Original Equipment Manufacturer (Oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required. Inverter Type Cooling With 5 Star Bee Rating , Minimum Value Of Iseer 5.6 , Copper Refrigerant Piping For 1.5Tr Hi-Wall Split Ac - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, Along With Electrical Flexible Copper 4Core Cable All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 1.5 Tr Hi - Wall Split , Copper Refrigerant Piping For 2.0Tr Cassette Type Split Units - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines,Along With Electrical Flexible Copper 4Core With All Accessoriesas Per Specifications Etc. As Required 9.5 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 2.0 And 15.86 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 2.0 Tr Cassette Type Split Units , Drain Pipe - Supply And Fixing Of Duly Insulated 25Mm Upvc Drain Pipe , Outdoor Stand For 1.5Tr Hi-Wall Split Ac - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1.5 Tr Hi-Wall Split Ac. , Outdoor Stand For 2.0Tr Cassette Type Split Units - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 2.0 Tr Cassette Type Split Units. , Voltage Stabilizer For 1.5 Tr Split Systems - Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 4Kva,Input Voltage Range 130-260 Voltage ,Output Voltgae Range 195-245 Voltage ,Metalic Encloser,100% Copper Winding,Wall Mounting Type,Digital Type Voltmeter,Class B Type Insulation Temperature And Furnish All Test Report And Certificate.The Product With Minimum 2 Yrs Of Warranty,Automatic Line Voltage Correctors(Step Type) As Per Is-8448 1989 , Voltage Stabilizer For 2.0 Tr Cassette Systems - Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 5Kva,Input Voltage Range 130-260 Voltage ,Output Voltgae Range 195-245 Voltage ,Metalic Encloser,100% Copper Winding,Wall Mounting Type,Digital Type Voltmeter,Class B Type Insulation Temperature And Furnish All Test Report And Certificate.The Product With Minimum 2 Yrs Of Warranty,Automatic Line Voltage Correctors(Step Type) As Per Is-8448 1989

AI Tender Summary

OUR REF NO 57043339
AUTHORITY Government Departments
TENDER VALUE 25.36 Lakhs
LAST DATE 27-08-2026
Authority
Authority Name State Bank Of India
Work Description Bids Are invited for Sitc Of Hiwall And Cassette Air Condition Systems Sitc Of 1.5 Tr Hi-Wall Split Systems - Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating, Minimum Value Of Iseer 5.6 , Sitc Of 2.0Tr Cassette Type Split Systems - Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(Idu), Out Door Unit (Odu), R-32/R410a/R-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230V, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (Idu To Odu), Copper Power Andcontrol Cable Upto 5.5 Mtr (Idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,Dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/Rotary Compressor With Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is -1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (Nabl) Accredited As Per International Electrotechnical Commission (Iec) 17025 Standards/Central Power Research Institute (Cpri)/ Electrical Research And Development Association (Erda)With Original Equipment Manufacturer (Oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required. Inverter Type Cooling With 5 Star Bee Rating , Minimum Value Of Iseer 5.6 , Copper Refrigerant Piping For 1.5Tr Hi-Wall Split Ac - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, Along With Electrical Flexible Copper 4Core Cable All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 1.5 Tr Hi - Wall Split , Copper Refrigerant Piping For 2.0Tr Cassette Type Split Units - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines,Along With Electrical Flexible Copper 4Core With All Accessoriesas Per Specifications Etc. As Required 9.5 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 2.0 And 15.86 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 2.0 Tr Cassette Type Split Units , Drain Pipe - Supply And Fixing Of Duly Insulated 25Mm Upvc Drain Pipe , Outdoor Stand For 1.5Tr Hi-Wall Split Ac - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1.5 Tr Hi-Wall Split Ac. , Outdoor Stand For 2.0Tr Cassette Type Split Units - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 2.0 Tr Cassette Type Split Units. , Voltage Stabilizer For 1.5 Tr Split Systems - Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 4Kva,Input Voltage Range 130-260 Voltage ,Output Voltgae Range 195-245 Voltage ,Metalic Encloser,100% Copper Winding,Wall Mounting Type,Digital Type Voltmeter,Class B Type Insulation Temperature And Furnish All Test Report And Certificate.The Product With Minimum 2 Yrs Of Warranty,Automatic Line Voltage Correctors(Step Type) As Per Is-8448 1989 , Voltage Stabilizer For 2.0 Tr Cassette Systems - Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 5Kva,Input Voltage Range 130-260 Voltage ,Output Voltgae Range 195-245 Voltage ,Metalic Encloser,100% Copper Winding,Wall Mounting Type,Digital Type Voltmeter,Class B Type Insulation Temperature And Furnish All Test Report And Certificate.The Product With Minimum 2 Yrs Of Warranty,Automatic Line Voltage Correctors(Step Type) As Per Is-8448 1989
Basic Detail
Tender No GEM/2026/B/7924724
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 17 Aug 2026
Submission Date 27 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 25.36 Lakhs
Tender Fee Ref. Documents
EMD 21500
Exemption Not Available
Document List
90ed4bdf-77f7-449a-a714-704083d73dd1.pdf
9764391_Boq_1.xlsx
nit_for_ac_work_berhampore_2026-08-17-12-30-51_775706a5418137b5a64cb9f19c26f372.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

90ed4bdf-77f7-449a-a714-704083d73dd1.pdf

xlsx

9764391_Boq_1.xlsx

pdf

nit_for_ac_work_berhampore_2026-08-17-12-30-51_775706a5418137b5a64cb9f19c26f372.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders