Tender for Provision Of Construction For Office Building Of Division Labour Commissioner Dhenkanal At Maisianpal Dist Dhenkanal Buildings.

BOQ

Name of Work:- Provision of construction for office building of Division labour commissioner Dhenkanal at maisianpal dist Dhenkanal Buildings.
Sl. No. Item Description
1CIVIL WORKS:-Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned upto a lead of 1000metres including removal and disposal of top organic soil not exceeding 150mm in thickness as per Clause 201 of MoRT&H Specifications for Road & Bridge works Latest Revision & including cost of all labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge.
2Earth work excavation in foundation trenches in all kinds of soil including dressing and levelling the bed up to required depth and depositing the excavated materials at places away from work site within 50 mtr initial lead and 1.5mtr initial lifts T&P shoring shuttering dewatering if required etc. complete as per direction of the Engineer-in-charge.
31st Extra lift (1.5m to 2.0m depth)
4Earth work excavation in foundation trenches in hard soil including dressing and levelling the bed up to required depth and depositing the excavated materials at places away from work site within 50mtr initial lead and 1.5mtr initial lifts T&P shoring shuttering dewatering if required etc. complete as per direction of the Engineer-in-charge.
5Supplying filling in foundation and plinth with sand in layers including watering, ramming, cost of conveyance, royalty and taxes of all materials, all labour T&P required for the work etc. complete as per direction of the Engineer-in-charge. (measurement will be taken on finished compacted section only).
6Filling foundation and plinth with excavated earth ramming etc complete as per approved drawing and technical specifications in all respect & as per direction of the Engineer-in-Charge.
7Cement concrete of propertion (1:3:6) in foundation and floors using 40mm nominal size clean hard black cursher broken granite metal of approved quality from approved quarry including lowering laying concrete in layers not exceeding 15cm thick to the required level ramming watering curing centering & shuttering etc. complete including cost conveyance royalty taxes of all materials and all labour T&P required for the work etc. complete as per direction of the Engineer-in-charge.
8Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge.Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (PREMISE, IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.
9RCC work of M-25 in all floors having a minimum compressive strength ( in work test) 250 kg/cm2 in 15cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 10mm size to 20mm size black hard crusher broken granite stone chips (10mm size 40% & 20mm size 60%) of approved quality & from approved quarry including hoisting lowering laying and compacting concrete with centering & shuttering and finishing the exposed surface smooth providing grooves or beads where necessary and providing required No. of fan hooks as required including cost, conveyance, royalties and taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect but excluding cost of MS rod / Tor steel and binding wire and labour charges for bending binding and tying the grills etc. complete as per direction of the Engineer-in-charge.Foundation
10Plinth Beam
11Columns & Roof beam
12Lift Pit Wall
13Lift Pit Slab
14Staircase
15Lintel
16Chajja
17Roof slab
18First FloorColumns & Roof beam
19Staircase
20Lintel
21Chajja
22Roof slab
23Terrace FloorColumns & Roof beam
24Lintel
25Chajja
26Roof slab
27RCC work of M-20 having a minimum compressive strength ( in work test) 200 kg/cm2 in 15cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 10mm size to 20mm size black hard crusher broken granite stone chips of approved quality & from approved quarry including hoisting lowering laying and compacting concrete with centering & shuttering and finishing the exposed surface smooth providing grooves or beads where necessary and providing required No. of fan hooks as required including cost, conveyance, royalties and taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect but excluding cost of MS rod / Tor steel and binding wire and labour charges for bending binding and tying the grills etc. complete as per direction of the Engineer-in-charge.Drain Bottom slab
28Drain Top slab
29Drain wall
30Labour charges for straightening the coiled or bend up M.S. rod / HYSD bars confirming to Gr. Fe-500, cutting bending binding lapping placing welding etc. (Confirming to ISI specification) and jointing if necessary by lapping and tying the grills and placing in position as required for RCC work as per approved design hoisting lowering and laying in position including cost conveyance & taxes of M.S. rod / tor steel (Primary Producer like- SAIL/RINL/TATA/ JINDALSTEEL/ SHYAM STEEL) make) and binding wire of 18 to 20 gauge (as approved by the deptt.) weight of over lapping, couping, welded joints, spacer bar, chair, stage, hanger and binding wires shall not be considered for payment at all. Standard co-efficient of different size of the steel shall be considered. Welding & lapping should be confirming to relevant clause of IRC 1987 etc. complete as per direction of the Engineer-in-charge.Ground Floor
31First Floor
32Terrace Floor
33Fly Ash brick masonry using fly ash bricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with ordinary portland cement (OPC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-chargeFOUNDATION & PLINTH
34Ground Floor
35First Floor
36Terrace Floor
37Fly Ash brick masonry using fly ash bricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:4) with ordinary portland cement (OPC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge .Ground Floor
38First Floor
39Providing 16mm thick cement plaster in cement mortar (1:6) finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge.Ground Floor
40First Floor
41Terrace Floor
42Providing 12mm thick cement plaster in cement mortar (1:6) finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge.Ground Floor
43First Floor
44Terrace Floor
45Providing 6mm thick cement plaster in cement mortar (1:4) finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge.Ground Floor
46First Floor
47Terrace Floor
48Providing and laying 25mm thick grading Concrete of proportion (1:2:2 ) using 6mm size crusher broken black hard granite chips from approved quarry, scraping and cleaning the surface, fininishing smooth to proper slope and gradient including cost of all materials, cost of labour, conveyance, taxes, loading, unloading, curing,T&P, etc. all complete as per the direction of the Engineer-in-charge.First Floor
49Terrace Floor
50Supplying, fitting and fixing Vitrified Tile in floors, treads, steps and landing slabs of size 600mm x 600mm (Coloured/Printed) of approved make confirming to IS:13755 laid on 20mm thick bed of cement mortar (1:4) joined with neat cement slurry mixed with pigments to match the shades of the tiles including, rubbing and polishing the surface with cost, conveyance, royality and all taxes of all materials etc. complete as per direction of the Engineer-in-charge.Ground Floor
51First Floor
52Supplying, fitting and fixing of vitrified tiles (coloured/printed) in dados, skirting and risers of steps over 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with colouring pigments to match the colour and shade including the cost of washing, polishing, cost of materials, cost of all labour, conveyance, taxes, loading & unloading, T&P, watering and curing etc. complete as per the direction of the Engineer-in-Charge. Ground Floor
53First Floor
54Supplying, fitting and fixing Granite Tile (above 0.10 Sqm & up to 0.4 sqm (10mm. thick) in floors, treads, steps and landing slabs of approved make laid on 20mm thick bed of cement mortar (1:4) joined with neat cement slurry mixed with pigments to match the shades of the tiles including, rubbing and polishing the surface with cost, conveyance, royality and all taxes of all materials etc. complete as per direction of the Engineer-in-charge.Ground Floor
55First Floor
56Supplying, fitting and fixing Granite Tile (above 0.10 Sqm & up to 0.4 sqm (10mm. thick) in dados, skirting and risers of steps over 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with colouring pigments to match the colour and shade including the cost of washing, polishing, cost of materials, cost of all labour, conveyance, taxes, loading & unloading, T&P, watering and curing etc. complete as per the direction of the Engineer-in-Charge. Ground Floor
57First Floor
58Supplying, fitting and fixing Industrial Vitrified Tiles in floors, treads, steps and landing slabs of size 300mm x 300mm of approved make confirming to IS 4457 laid on 20mm thick bed of cement mortar (1:4) joined with neat cement slurry mixed with pigments to match the shades of the tiles including, rubbing and polishing the surface with cost, conveyance, royality and all taxes of all materials etc. complete as per direction of the Engineer-in-charge.
59Providing and fixing ISI marked 35mm flush door shutters, confirming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete as per direction of the Engineer-in-charge.
60Supplying and fitting-fixing of Un-plasticised Poly Viny/ Chloride(UPVC) (FENESTA /NCL VEKA LTD.) Three Track - Three Panel sliding window- 60- Series duly manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5 mm for outer frames and Window Sash of 39mm x 58mm x 2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window frame shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards etc. complete as per direction of the Engineer-in-charge.
61Supplying, fitting and fixing of two track UPVC sliding windows of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fittings and fixtures, etcetc. all complete as per the direction of Engineer-in-Charge.
62Supplying, fitting and fixing of fixed ventilators of approved make to be febricated from roll formed sections made of pre painted steel (base steel as per IS 513 of 0.6 mm thick D quality, galvanized as per IS 277 with zinc of 120 gm/Sqm) with paint specific 18x25 mm. Accessories / gaskets are to be used as per the manufacturers supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. Glass to be used of 5mm reflective with all taxes completeas per the direction of Engineer in Charge.
63Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2 0\\" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0\\" x 2'0\\" with 12mm thick Prelaminated Particle Board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge.Ground Floor
64Supplying fixing and fittings MS window grills, Doors, MS verandha grills and MS grill gate of approved design and drawing made out of MS flat and MS angle at work site with one coat of anticorrosive red oxide zink chrome primer including cutting holes in brick or RCC walls and fixing with CC (1:3:6) including cost conveyance royalty and taxes of all materials all labour T&P required for the work complete (payment will be made on weight basis only)(In all floors) etc. complete as per direction of the Engineer-in-charge.Door/Window
65Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of Engineer-in-Charge.
66Painting two coats with synthetic enamel paints of approved shade on Iron works including cleaning the surface with sand papering and using paints of approved quality and approved shade including cost conveyance taxes of all materials all labour T&P etc. complete as directed by the Engineer in charge.Ground Floor
67First Floor
68Terrace Floor
69Painting two coats with water proofing weather coat over a coat of primer of approved shade by means of brush to outside surface of walls in all floors with cost, carriage and all taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per direction of the Engineer in Charge.Ground Floor
70First Floor
71Terrace Floor
72Priming one coat with water bound cement primer of approved shade by means of brush to inside surface of walls in all floors with cost, carriage and all taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per direction of the Engineer in Charge.Ground Floor
73First Floor
74Terrace Floor
75Finishing wall surface with one coat Acrylic wall putty (water based) of approved quality by means of brush and finished smooth & even surface to receive painting including cost of scaffolding, cost of carriage and all taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per direction of the Engineer in Charge.Ground Floor
76First Floor
77Terrace Floor
78Painting two coats with Plastic emulsion paint of approved shade by means of brush to inside surface of walls in all floors with cost, carriage and all taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per direction of the Engineer in Charge.Ground Floor
79First Floor
80Terrace Floor
81Construction of granular material by providing Granular sub-base Grading-VI material as per table 400-1 ,spreading in unifrom layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC , and compacting with vibratory roller to achieve the desired density as per approved drawing and technical specifications complete in all respect as per Section 900 and Clause 401 of MoRT&H Specifications for road & Bridge works(latest Revision) including cost & conveyance of all materials, labour, T&P, royalty etc. complete and as per direction of Engineer-in-charge.
82Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018 and direction of the Engineer-in-Charge.
83Supplying and fixing of Pre cast kerb stone of size 300mm x300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984 and direction of the Engineer-in-Charge.
84ELECTRICAL WORKS Circuit Cum WiringRecessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked (Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-guard) with 20 mm dia HMS FRLS PVC conduit ISI marked (Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal) 6A modular type (anti bacterial & flame retardant type) switch ISI marked (Make- Schneider(Zencelo)/ legrand( Myrius-Next gen)/ Panasonic (vision)) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bacterial & flame retardant type) Make- Schneider(Zencelo)/ legrand( Myrius-Next gen)/ Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistranded copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group A
85Group B
86Group C
87Recessed wiring to Twin control light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked (Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-guard) with 20 mm dia HMS FRLS PVC conduit ISI marked (Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal) 6A modular type (anti bacterial & flame retardant type) 2way switch ISI marked (Make-Schneider(Zencelo)/ legrand( Myrius-Next gen)/ Panasonic (vision)) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bacterial & flame retardant type) Make- Schneider (Zencelo)/ legrand (Myrius-Next gen)/ Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistranded copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
88S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make- Schneider(Zencelo)/ legrand (Myrius-Next gen)/ Panasonic (vision)
89Supplying, fixing of 6A switch socket on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bacterial & flame retardant type)) & other required accessories of ISI marked as approved as per direction of Eng. -in -Charge. Make- Schneider (Zencelo)/ legrand (Myrius-Next gen)/ Panasonic (vision). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
90Supplying, fixing of 6A switch socket on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bacterial & flame retardant type)) with suitable size modular box & cover(anti bacterial & flame retardant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make- Schneider (Zencelo)/ legrand (Myrius-Next gen)/ Panasonic (vision). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
91Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
92Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
93Supplying,fixing of 2X1 6A Switch Socket on the separate board with complete fitting by 02 nos of 16A switch & socket(modular type) (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider(Zencelo)/ legrand( Myrius-NEXT GEN)/ Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
94Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
95Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover Legrand/Schneider/Siemens/Panasonic .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
96Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make- Akg/ Bec/ Precision/ Norpack/ Anchor/ Kinjal as required as per direction of Eng.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuity conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/ LIGHT CKT) (2X1.5+1X1.5)
972 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/ LIGHT CKT/ 5A PLUG/ UPS POINT) (2X2.5+1X1.5)
982 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuity conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/ AC POINT) (2X4+1X1.5)
992 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuity conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/ UBDB) (2X6+1X2.5)
1004 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuity conductor in 32 mm dia non metallic heavy duty conduit. (LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
101Fan & indoor FixturesSupplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years.
102Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj).The luminaire should be Replacement Warranty will be 2 years
103Supplying and fixing of Energy efficient surface /recess mounted square /round shape 12 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 12 watt and lumen output of 1200 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj).The luminaire should be Replacement Warranty will be 2 years
104Supplying and fixing of Energy efficient surface /recess mounted square /round shape 9 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 9 watt and lumen output of 900 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj).The luminaire should be Replacement Warranty will be 2 years
105SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj). The luminaire should be Replacement Warranty will be 2 years .
106SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser, above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj)The luminaire should be Replacement Warranty will be 2 years
107Providing and fixing IP65 LED Bulk Head Light of 15w with UV-resistant housing, opal diffuser, PF 0.90 driver, CRI 80, complete with necessary mounting accessories, wiring, testing and commissioning as required at site. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj). The luminaire should be Replacement Warranty will be 2 years
108S/F of Street light- 45W,120 lm/w efficacy , new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj) (5Years Warranty)
109Supplying, installation, testing and commissioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3/min Make- Crompton Energion Groove/ Havells Efficiencia Neo/ Usha Technix/ Bajaj Turbo Pro 12DC5) including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Eng.-in-Charge, Replacement Warranty will be 4 years.
110Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
111Providing and fixing Wall Mounted Oscillating Fan of 400mm sweep, metal body with metal blades and guard, copper wound motor with thermal protection, complete with 3-speed wall regulator, suitable for 230V AC supply, including mounting hardware, connections, testing and commissioning as required. (Make- Havells/ Crompton/ Usha/ Orient/ Bajaj)
112Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/ Crompton/ Usha/ Orient/ Bajaj) of exhaust fan in the existing wall, including fixing & connection as required as per direction of Eng.-in-Charge. Replacement Warranty will be 2 years.
113Panels, MDBs, DBs. MCBs Main LT Panel S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for Light & Power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. One (1) Incomer-200 Amp, 4P MCCB with ROM 25kA with Thermal Magnetic release with Ics=100% Icu. (Make-Legrand-DPX3 / Siemens 3VA Model/ Schneider CVS/ ABB Formula) with shunt trip , One(1) set of 100/5A , 15VA , CL 1.0, CT with 3 Nos Phase indicating lamps with control fuse/ MCB Digital Voltmeter and Ammeter with selector switch. (with required other accesories.) One (1) set of 4Pole Onload manual Changeover switch Busbar - 200 Amp Al busbar suitable for operation at 415 Volt, 50 Hz, 3 Phase Supply. Separate Aluminium Earth bus bar should be installed Two(2) Outgoing Feeders for (1 no for Lift and 1no for Fire Downcomer) each Comprising of One (1)-63 Amp, 4P MCCB with ROM 16kA with Thermal Magnetic release with Ics=100% Icu. (Make Legrand DPX3 / Siemens-3VA Model/Schneider-CVS/ ABB Formula) with 3 Nos Phase indicating lamps with control fuse/ MCB. One(1) Outgoing Feeders for (1 no UPS) each Comprising of One (1)-32 Amp, 4P MCCB with ROM 16kA with Thermal Magnetic release with Ics=100% Icu. (Make- Legrand-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) with 3 Nos Phase indicating lamps with control fuse/ MCB. Six(4) Outgoing Feeders for (2 No PDBs, 2 Nos ACDB & Two spare) each Comprising of One (1) 63A FP 10KA MCB, C Series Make-Legrand-DX3 / Siemens Betaguard/ Schneider-Acti 9/ ABB SB 200 with required other accesories. Six (6)-Outgoing Feeders for (2Nos LDB, 1no Water Supply and 3No spare) each Comprising of One (1) 32A DP 10KA MCB, C Series Make-Legrand-DX3 / Siemens-Betaguard/ Schneider Acti 9/ ABB SB 200 with required other accesories. PANEL AS ABOVE
114Solar Inverter OG Panel S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for Light & Power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. One (1) Incomer -32A DP Onload Changover Switch. Busbar - 100 Amp Al busbar suitable for operation at 230 Volt, 50 Hz, 1 Phase Supply. Separate Aluminium Earth bus bar should be installed Three (3) - Outgoing Feeders for (2Nos UDB and 1No spare) each Comprising of One (1) -32A DP 10KA MCB, C Series Make- Legrand-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 with required other accesories. PANEL AS ABOVE
115Lift PanelSITC of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder coated paint is designed as G.A drawing. (FOR LIFT)as per direction of Engg.-in-Charge. Warranty period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. 63amp panel board having 63A Amp 16KA 4P MCCB TMR based release with adjustable overload ,Icu=100%Ics as incommer, 100 amp electrolyte Aluminium bus ba-1 Set, 63A Amp 4P RCCB 30mA- 1 No,25A Amp DP RCCB 30mA- 2 No,6-32A DP MCB 10ka, c series -2 No as Outgoing with ampere meter, voltmeter, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make of mccb :-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA) Make of MCB-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(Lift Panel)
116DBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
1178Way(8+(4x3)+(8x3)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-24 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
118Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
119Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years..
120Supplying and fixing 32 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB complete with connections as per direction of Eng.-in-Charge. Warranty on MCB is 1 years.
121Supplying and fixing 25 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB complete with connections as per direction of Eng.-in-Charge. Warranty on MCB is 1 years.
122Supplying and fixing 40Amps 4P 415 volts MCB Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
123Supplying and fixing 63Amps 4P 415 volts MCB Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
124Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 230 volts, RCCB 30mA . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The RCCB should be Replacement Warranty will be 1 year
125Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year
126Supplying and fixing 32Amps 2P 240 volts AFDD(arc fault detection device) Make- ABB S ARC1 M/ Equivalent model of Schneider/ Legrand/ Siemens ,10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year
127Supplying and fixing 40Amps 2P 240 volts AFDD(arc fault detection device) Make- ABB S ARC1 M/ Equivalent model of Schneider/ Legrand/ Siemens ,10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year
128Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board, Make-LEGRAND/ Siemens/ Schneider/ OBO/ DEHN in the existing MCB DB with connections as per direction of Engg.-in-Charge.The SPD should have Replacement Warranty will be 1 year.
129Cables supplySupplying & Testing of 1.1 KV grade Aluminium XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (Make:- Polycab/ Havells/ KEI/Gloster/Finolex/RR Kabel)4C X 16 sqmm
1303.5C X 50 sqmm
131CABLE LAYINGLaying of One No. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing On Wall Surface(Clamped with saddle/ PVC & UPVC Pipe)/ CableTray as required.Upto 25 sq. mm
132Above 25sqmm upto 120sqmm
133TERMINATION OF CABLESSupply & Making end Termination with brass double compression gland and Cu/aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable) (Make: Raychem/ M-seal/ 3M)4C X 16 sqmm
1343.5C X 50 sq. mm
135TVSupply, delivery, installation & testing of TV outlet boards containing a clip-in type modular TV Socket outlet fixed on metallic concealed box including connections and making good the damages caused complete as required and as per direction of Engineer-in-charge. (Make: Legrand/ Schneider/ Havells/ Panasonic/ ABB)
136Supplying and laying of Coaxial copper conductor TV antenna cable run inside prelaid conduit complete including termination, testing etc complete as required and as per direction of Engineer-in-charge. (Make:- Polycab/ Havells/ KEI)
137ConduitsSupplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge. Make- AKG/ BEC/ Precision/ Norpak/ Kinjal. (Only for data/ telephone/ CCTV)20mm dia
138EarthingSupplying,installation,testing & commissioning of materials and installation of GI earth plate 600mm x 600mm x 6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
139Providing and fixing 25 mm X 5 mm dia G.I strip on wall/surface With required DMC insulator and nut bolt connection etc. as required.
140FIRE FIGHTING -: Supplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame. (Pump Make :KBL/ Grundfos / KSB/ Wilo)
141Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V. Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrinkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action. Make- Legrand/ schneider/ Siemens/ ABB
142SITC of FRLS, PVC outer sheathed, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge 3C x 16 mmsq. Make- Finolex/ Anchor/ KEI/ Polycab/ RR kabel
143Supply & Fixing of 2 core 1.5 sq.mm, multi strand, copper conductor, FRLS (Fire Retardant Low Smoke)-PVC insulated GI Screened Armoured cable with saddle and required accessories.& Power Cable. Make- Finolex/ Anchor/ KEI/ Polycab/ RR kabel
144Supply & Fixing of G.I. earthing strips of 25mm x 6mm thick, strip shall be run for Pumps.
145PIPE & VALVES ETC.Supply, Installation, Testing & Commissioning of 'C' Class heavy duty MS pipe (as per IS 1239 upto 100 mm NB and IS 3589 for above 100 mm 6.33mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size on surface along wall / shaft with MS bracket, suspended from ceiling/ beam with suspenders duly painted with two coats of primer and finished with enamel paint of approved colour laid through pipe or in trench after wrapping with hassen cloth after applying coal tar primer as required as per direction of Engineer-in- charge. Make- Tata/ Sail/ Jindal100mm NB
14680mm NB
14725mm NB
148Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C. Make- Zoloto/ Kirloskar100mm NB
149Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make- Zoloto/ Audco/ Leader100mm NB
150Supply, Installation, Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge. Make- H.Guru/ G.Guru
151Supply, Installation, Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge. Make- Danfoss/ Indfoss/ Grundfoss
152Supply, Installation, Testing & Commissioning of stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia holes with stainless steel flange as required. Make- Zoloto/ Audco/ Leader100mm NB
153DOWN COMER SYSTEMSupply, Installation, Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge. Make- Newage/ Minimax/ Fireshield
154Supply, Installation, Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge. Make- Newage/ Minimax/ Fireshield
155Supply, Installation, Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm instantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge. Make- Newage/ Minimax/ Fireshield
156Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accommodate 2 nos. of 15/ 1 no of 30 mar long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge. Make- Newage/ Minimax/ Fireshield
157Supply, Installation, Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge. Make- Newage/ Minimax/ Fireshield
158Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge.
159Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per approved specification & direction of EIC. Make- Zoloto/ Audco/ Leader
160EXTINGUISHER SYSTEMSupply, Installation, Testing and Commissioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories (Safex/ Ceasefire/ Fire shield/ Flameklog)
161Supply, Installation, Testing and Commissioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Make:- Safex/ Ceasefire/ Fire shield/ Flameklog)
162Manual fire alarm systemManual Fire Alarm System-:Supply, installation, testing and commissioning of Conventional type Main Fire Alarm Control Panel (FACP), the panel shall be conventional type fire detection and alarm system with capacity of 4 zone complete with all accessories and battery back up for 48 hours in standby mode and 15 minutes in alarm condition. The panel shall have minimum of 80 character display complete accessories. Make- System sensor by Honeywell/ Ravel/ Bosch.
163Supplying, installing, testing and commissioning of conventional type Manual call point with all accessories complete. The device Make-System sensor by Honeywell/ Ravel/ Bosch.
164Supplying, installing, testing and commissioning of conventional type Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. Make-System sensor by Honeywell/ Ravel/ Bosch. Please Enable Macros to View BoQ information
165Supplying, installing, testing and commissioning of conventional type Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. Make-System sensor by Honeywell/ Ravel/ Bosch. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57040900
AUTHORITY Government Departments
TENDER VALUE 2.64 Crore
LAST DATE 28-08-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Provision Of Construction For Office Building Of Division Labour Commissioner Dhenkanal At Maisianpal Dist Dhenkanal Buildings.
Basic Detail
Tender No CCE Dkl (R and B) -08 / 2026-27
Bidding Type Tender
Location
City Dhenkanal
State Odisha
Key Dates
Publish Date 14 Aug 2026
Submission Date 28 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value 2.64 Crore
Tender Fee 10000
EMD 2.65 Lakhs
Exemption Available
Document List
BOQ_606124.xls
f42d8a68-f68d-41a1-a6aa-1f99751b475f.html
Tendernotice_1 (11).pdf
Tendernotice_2.pdf
Tendernotice_3 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_606124.xls

html

f42d8a68-f68d-41a1-a6aa-1f99751b475f.html

pdf

Tendernotice_1 (11).pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders